TenderDekho Logo
Closed GEM

Contract Bidding Open For Radiofrequency Generator with Vessel Sealing and Bipolar Resection in BATHINDA, PUNJAB

Bid Publish Date

23-Jul-2026, 12:51 pm

Bid End Date

24-Aug-2026, 1:00 pm

Generate Docs

Progress

Issue23-Jul-2026, 12:51 pm
Corrigendum14-Aug-2026
AwardPending

All India Institute Of Medical Sciences (aiims) invites bids for Radiofrequency Generator with Vessel Sealing and Bipolar Resection (Q3) in BATHINDA, PUNJAB. Quantity: 1. Submission Deadline: 24-08-2026 13: 00: 00. Submit your proposal before the deadline.

Advertisement

Tender Data

Bid Details

Quantity

1

Bid Type

Two Packet Bid

Bid Validity

180 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

RA Qualification Rule

H1-Highest Priced Bid Elimination

Tech Clarification Time

3 Days

Preference & Exemptions

EMD Required

Yes

MII Purchase Preference

Yes

MII Preference Band

L1+20%

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

Yes

Startup Exemption/Relaxation

No

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

50

OEM Avg. Turnover

400

Past Performance

50 %

Warranty Period

5 years

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Radiofrequency Generator with Vessel Sealing and Bipolar Resection (Q3)

Advisory Bank

State Bank of India

ePBG Percentage

5%

ePBG Duration (Months)

62

Pre-Bid & Qualification

Pre-Bid Date

29-07-2026 12:00:00

Pre-Bid Venue

Meeting Hall, Department of CFM, 3rd Floor, B Block, Medical College, AIIMS Bathinda.

Delivery Details

Max Delivery Days

45

Delivery Locations

1

Delivery Cities

Bathinda

Delivery Pincodes

151001

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Vivek Sharma151001,Mandi Dabwali roadBathindaPunjab151001145-

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9637377.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Categories 5

Advertisement

Corrigendum Updates

1 Update
#1

Update

14-Aug-2026

Extended Deadline

19-Aug-2026, 7:30 am

Opening Date

19-Aug-2026, 8:00 am

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Radio Frequency Identification Mode of Operation Simplex, Duplex
Generic Mounting OEM Trolley with lockable castor wheels
Generic Storage Capacity 4
Wireless Fidelity (Wifi) Data Rate, Mbps 11b: 1/2/5.5/11 Mbps, 11g: 6/9/12/24/36/48/54 Mbps, 11n: (20 MHz): MCSO-7 (Up to 72 Mbps), 11n: (40 MHz): MCSO-7 (Up to 150 Mbps)
Wireless Fidelity (Wifi) Output Power of Wireless Fidelity (Wifi) 11b: 17 +/- 1.5 dBm, 11g: 15 +/- 1.5 dBm, 11n: 14 +/- 1.5 dBm
Leakage Patient Leakage Current < 10 micro Ampere NC, < 50 micro Ampere SFC
Leakage Patient Auxiliary Current (less than 1kHz) < 10 micro Ampere NC, < 50 micro Ampere SFC
Leakage Touch Current < 100 mirco Ampere Normal Current, < 500 micro Ampere Single Fault Condition
Leakage Earth Leakage Current < 500 micro Ampere NC, < 1000 micro Ampere SFC
Leakage Total Patient Leakage Current < 50 micro Ampere Normal Current, < 100 micro Ampere Single Fault Condition
Output Characteristics Impedance Sense Range 5 - 135
Output Characteristics Crest Factor 1 - 7
Output Characteristics Peak Voltage 50 - 3575
Output Characteristics Rated Output Power 15 - 375
Output Characteristics Current RMS, Maximum 1 - 6
Output Characteristics Bipolar Modes Precise, Standard, Macro
Output Waveform, Vessel Sealer and Driver, Monopolar Output Interrogation frequency of Output Waveform 423 - 445
Output Waveform, Vessel Sealer and Driver, Monopolar Output Independent Vessel Sealing and Cutting of Vessel sealer and Divider Curved Jaw, Small Curved Jaw, Large Curved Jaw, Straight Jaw
Output Waveform, Vessel Sealer and Driver, Monopolar Output Monopolar Output 3 button pencil with power output control from sterile field
OEM Accessories Accessories 2 Button ESU Pencils (10), 3 Button ESU pencil (5), Patient Return Electrode with Cable -Adult (10), Curved Jaw Vessel Sealer with integrated cutting blade - 37 cm shaft, 5 mm diameter (2), Straight Jaw Vessel Sealer with Integrated Cutting Blade - 37 cm shaft, 5 mm diameter (2), Curved, Large Jaw, vessel sealer with integrated cutting blade (2), Curved, Small Jaw, Vessel Sealer with Integrated Cutting blade (2), Non stick vessel sealer with integrated cutting blade (2), Monopolar Footswitch (1), Bipolar Footswitch (1), Vessel sealing Footswitch (1), Universal Monopolar Adapter (1), Bipolar Resection Footswitch (1) with Bipolar resection cord compatible with type of resectoscopes (1), Bipolar Forcep with cable - Bayonet (1), Bipolar Forcep with Cable - Cushing (1), Needle electrode (2)|Ball electrode (2), Extended electrode (5)
Advertisement