Bharat Sanchar Nigam Limited Portal(bsnl) invites bids for DG servicing 15 KVA, DG servicing 20-25 KVA, DG servicing 30-40 KVA, DG servicing 50-82. 5 KVA, DG servicing 100-125 KVA, Providing fixing of 12 volt 100 Ah maintenance free Battery, Providing fixing of 12 volt 130 Ah maintenance free Battery, Providing fixing of 12 volt 150 Ah maintenance free Battery, Providing fixing of 12 volt 180 Ah maintenance free Battery, Replacement of Stop Solinoid 12 volt, Mechanical Type RPM Cum Hour Meter, RPM Cum Hour Meter Chain, 12 V 10 amp Battery Charger SMPS ic Transformer, Oil pressure gauge, Oil temperature meter, Oil temperature safety, Water temperature meter, Starting key switch, 100 amps THREE POLE MCCB 18 KA, VAF meter, 32 Amp 4 pole MCB, 63 Amp 4 Pole MCB, DC voltmeter, DC Ammeter, Auto manual Rotary switch, Overspeed safety, Battery leads flexible ic terminals, Coolant, Flexible wire braided fuel pipe. , Benzo Bolts. , Engine start relay, V Belt, LED Type Indication Lights, Repairing and General Servicing of the existing faulty radiator Upto 20KVA DEA set, Repairing and General Servicing of the existing faulty radiator above 20KVA Upto 50KVA DEA set, Servicing of the self starter of DEA set, Repairing of following faulty items in the self starter Carbon bush set, Repairing of following faulty items in the self starter Solenoid coil, Repairing of following faulty items in the self starter Bendex Gear, Supplying and installation of 12 volt battery operated self starter, Calibration of the fuel injection pump up to 20 KVA DEA set, Calibration of the fuel injection pump More than 20 KVA and up to 50 KVA, Extra charges for associated items of fuel pump Delivery valve, Extra charges for associated items of fuel pump Delivery element, Extra charges for associated items of fuel pump Nozzle, Repairing of cylinder head, Replacement Repairing of faulty AVR Make National or SS, Replacement Repairing of faulty Power Diode for Rotating Rectifier Assembly, Rewinding of existing parts upto 50 KVA Main Stator winding, Rewinding of existing parts upto 50 KVA Main rotor winding, Rewinding of existing parts upto 50 KVA Exciter Stator winding, Rewinding of existing parts upto 50 KVA Exciter rotor winding, Repairing of existing canopy of 15 KVA DG set, Rewinding of existing exhaust fan in 15 KVA DG silent enclosure, Supplying and fixing of 450 mm sweep, Replacement of on load Changeover switches Four Pole 32A with side handle with SS enclosure, Replacement of on load Changeover switches Four Pole 63A with side handle with SS enclosure, Repairing of control wiring of existing, Replacement of faulty coupling 10 15 KVA, Replacement of faulty coupling 20 30 32 KVA, Dismentling the Fuel tank from canopy and Cleaning the tank, Dismentling the Fuel tank from canopy and trasporting the same in SHIMLA, HIMACHAL PRADESH. Quantity: 609. Submission Deadline: 21-08-2025 15: 00: 00. Submit your proposal before the deadline.
    GEM   
 Invitation to Bid – DG servicing 15 KVA,DG servicing 20-25 KVA,DG servicing 30-40 KVA,DG servicing 50-82.5 KVA,DG servi in SHIMLA, HIMACHAL PRADESH
Posted
11 Aug 2025, 11:42 am
Deadline
21 Aug 2025, 03:00 pm
EMD
₹48,375
Value
₹24,18,726
Location
Progress
Issue11 Aug 2025, 11:42 am
AwardPending
Quantity
609
Category
DG servicing 15 KVA
Bid Type
Two Packet Bid
   
Categories
 57  
    VOLTMETER   DECIBEL METER   HOOK UP WIRES   DIODE   FUEL INJECTION   BOLTS   PRESSURE GAUGE   WEIGH BRIDGE   THERMOWELLS   PRESSURE REGULATOR   ELECTRICAL PRODUCTS   VALVE   WIRE   GEAR   AMPS   FLEXIBLE WIRE   FUEL PUMP   SOLENOID VALVES   WELL TESTING EQUIPMENTS   INDUCTION MOTORS   INSULATED WIRE   TELECOM EQUIPMENT   WATTMETERS   ROTARY SWITCHES   MCCB   FAN SPARE PARTS   COOLANT   PYROMETERS   ELECTRICAL SUBSTATION   STATIC CONVERTERS   SYNCHRONOUS MOTORS   FIRE BREATHING APPARATUS   STARTER   ELECTRONIC COUNTERS   DRY CELL BATTERIES   GAUGE   RECTIFIERS   BATTERY   SOLID ROCKET MOTORS   CANOPY   NOZZLE   ENGINE   POWER   PRESSURE INDICATORS   HOUR METER   OTHER COIL   ELECTRICAL COIL   FAN   AIR EXHAUSTER   BUSH   MEDICAL DIAGNOSTIC GAMMA CAMERAS   BLASTING MACHINE   WEIGHTS   OIL GAUGES   BATTERY ADAPTER AND ACCESSORIES   SMPS   AC AND DC POWER SUPPLY  
    
Bill of Quantities (BOQ)
 62 Items  
 | Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | 
|---|---|---|---|---|---|---|
| 1 | DG servicing 15 KVA | As per ATC | 20 | jobs | eeesml | 15 | 
| 2 | DG servicing 20-25 KVA | As per ATC | 10 | jobs | eeesml | 15 | 
| 3 | DG servicing 30-40 KVA | As per ATC | 10 | jobs | eeesml | 15 | 
| 4 | DG servicing 50-82.5 KVA | As per ATC | 8 | jobs | eeesml | 15 | 
| 5 | DG servicing 100-125 KVA | As per ATC | 1 | jobs | eeesml | 15 | 
| 7 | Providing fixing of 12 volt 100 Ah maintenance free Battery | As per ATC | 30 | nos | eeesml | 15 | 
| 8 | Providing fixing of 12 volt 130 Ah maintenance free Battery | As per ATC | 12 | no | eeesml | 15 | 
| 9 | Providing fixing of 12 volt 150 Ah maintenance free Battery | As per ATC | 5 | no | eeesml | 15 | 
| 10 | Providing fixing of 12 volt 180 Ah maintenance free Battery | As per ATC | 5 | no | eeesml | 15 | 
| 11 | Replacement of Stop Solinoid 12 volt | As per ATC | 30 | no | eeesml | 15 | 
| 12 | Mechanical Type RPM Cum Hour Meter | As per ATC | 12 | no | eeesml | 15 | 
| 13 | RPM Cum Hour Meter Chain | As per ATC | 4 | jobs | eeesml | 15 | 
| 14 | 12 V 10 amp Battery Charger SMPS ic Transformer | As per ATC | 35 | job | eeesml | 15 | 
| 15 | Oil pressure gauge | As per ATC | 5 | job | eeesml | 15 | 
| 16 | Oil temperature meter | As per ATC | 5 | nos | eeesml | 15 | 
| 17 | Oil temperature safety | As per ATC | 5 | nos | eeesml | 15 | 
| 18 | Water temperature meter | As per ATC | 5 | nos | eeesml | 15 | 
| 19 | Starting key switch | As per ATC | 12 | nos | eeesml | 15 | 
| 20 | 100 amps THREE POLE MCCB 18 KA | As per ATC | 12 | nos | eeesml | 15 | 
| 21 | VAF meter | As per ATC | 4 | nos | eeesml | 15 | 
| 22 | 32 Amp 4 pole MCB | As per ATC | 6 | nos | eeesml | 15 | 
| 23 | 63 Amp 4 Pole MCB | As per ATC | 5 | nos | eeesml | 15 | 
| 24 | DC voltmeter | As per ATC | 5 | nos | eeesml | 15 | 
| 25 | DC Ammeter | As per ATC | 5 | nos | eeesml | 15 | 
| 26 | Auto manual Rotary switch | As per ATC | 4 | nos | eeesml | 15 | 
| 27 | Overspeed safety | As per ATC | 5 | nos | eeesml | 15 | 
| 28 | Battery leads flexible ic terminals | As per ATC | 15 | jobs | eeesml | 15 | 
| 29 | Coolant | As per ATC | 40 | ltr | eeesml | 15 | 
| 30 | Flexible wire braided fuel pipe. | As per ATC | 30 | mtr | eeesml | 15 | 
| 31 | Benzo Bolts. | As per ATC | 20 | nos | eeesml | 15 | 
| 32 | Engine start relay | As per ATC | 8 | nos | eeesml | 15 | 
| 33 | V Belt | As per ATC | 8 | nos | eeesml | 15 | 
| 34 | LED Type Indication Lights | As per ATC | 10 | nos | eeesml | 15 | 
| 35 | Repairing and General Servicing of the existing faulty radiator Upto 20KVA DEA set | As per ATC | 5 | nos | eeesml | 15 | 
| 36 | Repairing and General Servicing of the existing faulty radiator above 20KVA Upto 50KVA DEA set | As per ATC | 5 | nos | eeesml | 15 | 
| 37 | Servicing of the self starter of DEA set | As per ATC | 20 | nos | eeesml | 15 | 
| 38 | Repairing of following faulty items in the self starter Carbon bush set | As per ATC | 10 | nos | eeesml | 15 | 
| 39 | Repairing of following faulty items in the self starter Solenoid coil | As per ATC | 5 | nos | eeesml | 15 | 
| 40 | Repairing of following faulty items in the self starter Bendex Gear | As per ATC | 5 | nos | eeesml | 15 | 
| 41 | Supplying and installation of 12 volt battery operated self starter | As per ATC | 10 | nos | eeesml | 15 | 
| 42 | Calibration of the fuel injection pump up to 20 KVA DEA set | As per ATC | 12 | nos | eeesml | 15 | 
| 43 | Calibration of the fuel injection pump More than 20 KVA and up to 50 KVA | As per ATC | 10 | nos | eeesml | 15 | 
| 44 | Extra charges for associated items of fuel pump Delivery valve | As per ATC | 8 | nos | eeesml | 15 | 
| 45 | Extra charges for associated items of fuel pump Delivery element | As per ATC | 8 | nos | eeesml | 15 | 
| 46 | Extra charges for associated items of fuel pump Nozzle | As per ATC | 8 | nos | eeesml | 15 | 
| 47 | Repairing of cylinder head | As per ATC | 4 | jobs | eeesml | 15 | 
| 48 | Replacement Repairing of faulty AVR Make National or SS | As per ATC | 20 | nos | eeesml | 15 | 
| 49 | Replacement Repairing of faulty Power Diode for Rotating Rectifier Assembly | As per ATC | 15 | nos | eeesml | 15 | 
| 50 | Rewinding of existing parts upto 50 KVA Main Stator winding | As per ATC | 5 | nos | eeesml | 15 | 
| 51 | Rewinding of existing parts upto 50 KVA Main rotor winding | As per ATC | 5 | nos | eeesml | 15 | 
| 52 | Rewinding of existing parts upto 50 KVA Exciter Stator winding | As per ATC | 5 | nos | eeesml | 15 | 
| 53 | Rewinding of existing parts upto 50 KVA Exciter rotor winding | As per ATC | 5 | nos | eeesml | 15 | 
| 54 | Repairing of existing canopy of 15 KVA DG set | As per ATC | 4 | job | eeesml | 15 | 
| 55 | Rewinding of existing exhaust fan in 15 KVA DG silent enclosure | As per ATC | 5 | job | eeesml | 15 | 
| 56 | Supplying and fixing of 450 mm sweep | As per ATC | 4 | job | eeesml | 15 | 
| 57 | Replacement of on load Changeover switches Four Pole 32A with side handle with SS enclosure | As per ATC | 10 | nos | eeesml | 15 | 
| 58 | Replacement of on load Changeover switches Four Pole 63A with side handle with SS enclosure | As per ATC | 10 | nos | eeesml | 15 | 
| 59 | Repairing of control wiring of existing | As per ATC | 5 | job | eeesml | 15 | 
| 60 | Replacement of faulty coupling 10 15 KVA | As per ATC | 3 | jobs | eeesml | 15 | 
| 61 | Replacement of faulty coupling 20 30 32 KVA | As per ATC | 2 | jobs | eeesml | 15 | 
| 62 | Dismentling the Fuel tank from canopy and Cleaning the tank | As per ATC | 5 | job | eeesml | 15 | 
| 63 | Dismentling the Fuel tank from canopy and trasporting the same | As per ATC | 5 | jobs | eeesml | 15 | 
AI-Powered Bidder Prediction
Companies most likely to bid
Unlock Bidder Insights
AI predictions on likely bidders
Required Documents
1
Experience Criteria
2
Bidder Turnover
3
Certificate (Requested in ATC)
4
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
5
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Download FREE!
Access all tender documents at no cost
    Documents  5  
 GeM-Bidding-8207715.pdf
Main Document
BOQ Document
BOQ
BOQ Document
BOQ
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS
GeM-Bidding-8207715.pdf
Main Document
BOQ Document
BOQ
BOQ Document
BOQ
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS