Karnataka Milk Federation Ltd Bulk Milk Cooler Unit Tender Kolar Karnataka 2026

Bid Publish Date

25-Feb-2026, 6:24 pm

Bid End Date

07-Mar-2026, 7:00 pm

EMD

₹1,62,000

Progress

RA
Issue25-Feb-2026, 6:24 pm
Reverse Auction10-Mar-2026, 5:00 pm
Award25-Mar-2026, 12:53 am
Explore all 4 tabs to view complete tender details

Quantity

6

Bid Type

Two Packet Bid

Key Highlights

  • Isolated item list includes Bulk Milk Cooler Tank with CIP facilities, auto CIP, milk inlet, and top cover limit switch.
  • DG Set integration, UPS, GRID/Sensor/Volume/Temperature sensors, and data logging for full plant automation.
  • Option clause allowing up to 25% quantity increase/decrease with corresponding delivery adjustments.
  • RTGS/online EMD payment accepted; DD payable at CHIMUL CHIKKABALLAPURA; hard copy submission within 5-15 days post bid.
  • Fire extinguisher requirement: ABC stored pressure type 1kg; ISI/IS standards not explicitly stated in data.
  • BoQ shows zero items; project scope emphasizes complete BMCU installation and interconnection.

Categories 5

Tender Overview

Karnataka Milk Federation Ltd (Animal Husbandry And Fisheries Department, Karnataka) invites bids for a Bulk Milk Cooler Unit (BMCU) to be installed at KOLAR, KARNATAKA 563101. Scope covers bulk milk cooler tank with CIP piping, Auto CIP system, milk inlet system, and associated components like DG set, data logging system, and control panels. The project requires comprehensive installation, commissioning, trial runs, and interconnecting piping for the entire plant. Estimated value is not disclosed; however, an EMD of ₹162,000 applies. The contract includes option to adjust quantity by up to 25% during or after award, with delivery timing calculated via the stated formula. This tender emphasizes integrated BMCU with fuel, electrical, and automation sub-systems, plus safety equipment & ISI-mark standards if specified in ATC. Unique aspects include a broad equipment stack (DG, fire extinguisher, water handling, and sensors) tied to a single installation scope.

Technical Specifications & Requirements

  • Bulk Milk Cooler Tank with CIP Facility and Auto CIP System; includes Milk Inlet System, Top cover opening limit switch for open type tanks, and Tank Type details.
  • Tank Capacity & Build: Gross capacity and Rated capacity of the milk cooler; inner/outer shell thickness and SS 304 hooks for hose piping.
  • Power, Control & Data: Main Control Panel with Servo Voltage Stabilizer; Display Type; Phase; Voltage range; Data Logging System with UPS, GRID Sensor, Volume Sensor, Temperature Sensor and DG Sensor; Panel Board.
  • Refrigeration & Pumping: Refrigerant type, Number of compressors, Pump inlet/outlet and Flow rate; IS-marked water piping; Hot Water Generator/Heat Recovery; Fire extinguisher (ABC 1kg); DG Set specifications: capacity, phase, IP ratings.
  • Installation & Commissioning: comprehensive installation, commissioning, trial runs, and interconnecting piping for the entire plant.
  • The BoQ is not populated; delivery scope is project-based and requires cohesive integration of all components.

Terms, Conditions & Eligibility

  • EMD: ₹162,000; options for payment via DD in favour of MD, CHIMUL or RTGS/online transfer to the specified Axis Bank account with proper bid reference.
  • Payment terms: RTGS/online payment possible; after award, Performance Security may be submitted as DD or PBG; delivery timelines follow the option clause and extended periods as defined.
  • Delivery & Execution: Full installation, commissioning, and trial runs; option to increase quantity by up to 25% during contract period with proportionate delivery time.
  • Documentation: Submission requirements include proof of EMD, scanned online transfer, and hard copy delivery within defined windows; necessary GST/PAN and OEM authorizations as applicable per ATC.
  • ATC & Special Clauses: AtC documents uploaded; adherence to activities during extended delivery period; supplier must comply with buyer’s terms and conditions.
  • Penalties & Compliance: Performance standards aligned to delivery and commissioning milestones; penalties/LDs applied per contract terms.

Key Specifications

  • Bulk Milk Cooler Tank with CIP facility and Auto CIP

  • Milk Inlet System and top cover limit switch for open type tank

  • Tank inner/outer shell thickness and SS 304 hooks

  • Main Control Panel with Servo Voltage Stabilizer and display

  • Data Logging System with UPS, GRID/Volume/Temperature sensors

  • Refrigeration unit with specified refrigerant and number of compressors

  • DG Set capacity and IP ratings for control panel

  • Piping material ISI marked for water handling

  • Fire extinguisher and safety equipment

Terms & Conditions

  • EMD amount ₹162,000; payment options via DD or RTGS/online

  • Quantity flexibility up to 25% with corresponding delivery timing

  • Installation, commissioning, and interconnecting piping are mandatory

Important Clauses

Payment Terms

EMD to be submitted; online RTGS payments accepted; DD payments payable to MD, CHIMUL; post-award performance security via DD or PBG

Delivery Schedule

Delivery period calculated using (Increased quantity ÷ Original quantity) × Original delivery period with minimum 30 days; extended delivery permissible as per option clause

Penalties/Liquidated Damages

LDs applicable for delays as per contract terms; specific penalty rates not disclosed in the ATC

Bidder Eligibility

  • Experience in supplying bulk milk cooling systems and associated control panels

  • Financial stability demonstrated by annual turnover and available credit

  • Ability to install, commission, and trial run complex BMCU with integrated sub-systems

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Bulk Milk Cooler Unit (Q2)

Authority Records

ANIMAL HUSBANDRY AND FISHERIES DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9045974.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Bulk Milk Cooler Tank CIP Piping For Closed type tank facilities for cleaning in place shall be provided which include CIP spray balls & SS piping from balance tank through milk pump to BMC and back to balance tank
Bulk Milk Cooler Tank Number of Agitators 1
Bulk Milk Cooler Tank Thickness of Inner shell of tank 2.0
Bulk Milk Cooler Tank Certificaton As Per ISO 5708 Type 2A II (Latest Version) Stndard
Bulk Milk Cooler Tank Thickness of Outer shell of tank 1.6
Bulk Milk Cooler Tank Bulk Milk Cooler Tank Rated Capacity 3000, 4000, 5000, 10000 Or higher
Bulk Milk Cooler Tank Number of SS 304 Hooks for Hose Pipe 4
Bulk Milk Cooler Tank Tank Type Closed Type
Bulk Milk Cooler Tank CIP Facility CIP Cleaning by spray balls using pump and balance tank for closed type tanks
Bulk Milk Cooler Tank Milk Inlet System Pump Feed System
Bulk Milk Cooler Tank Bulk Milk Cooler Tank Gross Capacity 3300, 4400, 5500, 11000 Or higher
Bulk Milk Cooler Tank Auto CIP System for Bulk Milk Cooling Tank Pre-Programed Automatic CIP system for claening of Milk Cooling Tank
Bulk Milk Cooler Tank Top cover opening limit switch for open type tank NA
Milk Tank Control Panel Display Type LCD, LED
Main Contol Panel with Servo Voltage Stabilizer Phase Three Phase
Main Contol Panel with Servo Voltage Stabilizer Voltage range 300 to 500 V
Refrigeration Unit Type of Refrigerant R22 or CFC free refrigerant
Refrigeration Unit Number of Compressor 2
Milk Pump Pump inlet/outlet 38 x 38mm with SMS unions
Milk Pump Flow Rate 10000 LPH
Food grade tanker loading/unloading hose pipe Size 38.0
Water Handling System for Bulk Milk Cooler Piping Material (ISI Marked) UPVC, CPVC
Hot Water Generator - Heat Recovery Unit Quantity 1, 2 Or higher
Fire Extinguisher ABC stored pressure type fire extinguisher 1kg each 3
Diesel Generator (DG) Set DG Set Capacity, kVA 20
Diesel Generator (DG) Set No of Phase Three Phase
Diesel Generator (DG) Set Alternator IP Rating IP 23
Diesel Generator (DG) Set IP Rating of Control Panel IP 53, IP 55
Data Logging System UPS NA
Data Logging System GRID Sensor LDR based and isolated to protect the reverse current flow., NA
Data Logging System Volume Sensor Pressure Based, EHEDG compliant, Food Grade, NA
Data Logging System Display 7 Segment LED, NA
Data Logging System DG Sensor LDR based, NA
Data Logging System Temperature Sensor 0-70 Degree Celciuos, Housing SS 304, NA
Data Logging System Compressor Sensor Current transmitting sensors, NA
Data Logging System Panel Board Metal Powder Coated/Height 50CM and Width 50 CM and Inner width 12.5 CM, NA
Installation, commissioning, trial runs and putting the BMCU in operation Interconnecting piping for the entire plant SS 304 piping 38 mm diameter, 1.6 mm thick

Required Documents

1

GST certificate

2

PAN card

3

Experience certificates (similar bulk milk cooler projects)

4

Financial statements (turnover proof)

5

EMD submission proof (DD or RTGS transfer receipts)

6

Technical bid documents

7

OEM authorizations (if required)

Corrigendum Updates

1 Update
#1

Update

26-Feb-2026

Reverse Auction Schedule

Completed

Start

10-Mar-2026, 5:00 pm

End

11-Mar-2026, 5:00 pm

Duration: 24 hours

Reverse Auction Document

✅ RA concluded. Check financial results for final rankings.

Technical Results

S.No Seller Item Date Status
1
CHADHA SALES PRIVATE LIMITED   Under PMA
Make : Chadha Delta Model : CDX3KETDC3P05-03-2026 16:44:12
2
Gemak Engineering Solutions   Under PMA
Make : GEMAK--Gemak Engineering Solutions Model : GES/BMC 3KL/ET/DC/3P07-03-2026 14:03:55
3
VENTURE STEELS PRIVATE LIMITED   Under PMA
Make : Venture Model : Venture 7 Segment LCD type Bulk Milk Cooler without datalogger cap. 3300Ltr07-03-2026 16:06:19

Financial Results

Rank Seller Price Item
L1
Gemak Engineering Solutions   Under PMA
Item Categories : Bulk Milk Cooler Unit
L2
CHADHA SALES PRIVATE LIMITED( MSE Social Category:General )    Under PMA
Item Categories : Bulk Milk Cooler Unit
L3
VENTURE STEELS PRIVATE LIMITED   Under PMA
Item Categories : Bulk Milk Cooler Unit

Contract / Result Documents 1

Please sign in or create an account to view contract details and download result documents.

Frequently Asked Questions

Key insights about KARNATAKA tender market

How to bid for the bulk milk cooler tender in Kolar

Bidders must submit EMD ₹162,000 via DD or RTGS to CHIMUL; include GST/PAN and experience certificates; upload scanned proof of online transfer; ensure hard copy delivery within 5 days of bid end date; follow ATC and option clauses.

What documents are required for the BMCU tender in Karnataka

Required documents include GST certificate, PAN, experience certificates for similar projects, financial statements, EMD proof, technical bid, and OEM authorizations if applicable; ensure submission aligns with buyer terms and T&C.

What are the key technical specs for the Bulk Milk Cooler

Specs include CIP facility with Auto CIP, Milk Inlet System, top cover limit switch, tank inner/outer shell thickness, SS 304 hooks, refrigeration with refrigerant type and multiple compressors, and data logging sensors (DG, grid, volume, temp).

When is the delivery deadline and option for quantity changes

Delivery timing follows a 25% quantity option; additional time is calculated as (Increase/Original) × Original period with minimum 30 days; extended delivery allowed per contract terms; delivery starts after order date.

What are the EMD payment options for this tender

EMD can be paid via Demand Draft in favour of MD, CHIMUL, payable at CHIMUL, Chikkaballapura, or via RTGS/online transfer to Axis Bank; provide transaction proof and bid number in payment details.

What safety and auxiliary equipment are included in the scope

Scope includes ABC 1kg fire extinguishers, water handling piping ISI marked, DG set, UPS, and various sensors for data logging; installation includes interconnecting piping and safety features for full plant operation.

What documents are needed to demonstrate eligibility for the bid

Submit GST and PAN, experience certificates for similar projects, financial statements, EMD proof, technical bid, and OEM authorizations; ensure compliance with ATC terms and provide hard copies within the specified window.

What is the role of the Data Logging System in the tender

Data Logging System features UPS, GRID Sensor, Volume and Temperature Sensors, DG Sensor, Display, and Panel Board; ensures real-time monitoring and recording of milk cooling operations and environmental parameters.