Neonatal Ventilators
Aligarh Muslim University (amu)
ALIGARH, UTTAR PRADESH
Bid Publish Date
30-Jun-2026, 11:08 am
Bid End Date
21-Jul-2026, 2:00 pm
EMD
₹60,000
Value
₹30,00,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
A tender has been published for Chacha Nehru Bal Chikitsalaya Neonatal Ventilators (Q2) in EAST DELHI, DELHI. Quantity: 1 by. Submission Deadline: 21-07-2026 14: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Neonatal Ventilators (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Aligarh Muslim University (amu)
ALIGARH, UTTAR PRADESH
Gujarat Medical Education And Research Society (gmers)
AHMEDABAD, GUJARAT
Gujarat Medical Education And Research Society (gmers)
GANDHI NAGAR, GUJARAT
Directorate Of Medical Education And Training
AGRA, UTTAR PRADESH
Directorate Of Medical Education And Training
AGRA, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| PERFORMANCE PARAMETERS | Patient Type | Neonatal |
| PERFORMANCE PARAMETERS | Tidal Volume Range In ml | 2 to 300 |
| PERFORMANCE PARAMETERS | Trigger Sensitivity Mechanism | Pressure and Flow |
| PERFORMANCE PARAMETERS | Flow Pattern/Waveform Adjustment | Yes |
| PERFORMANCE PARAMETERS | Sigh Breath Function | Yes |
| PERFORMANCE PARAMETERS | Leak Compensation Available | Yes |
| PERFORMANCE PARAMETERS | Auto 100% increase O2 Button | Yes |
| PERFORMANCE PARAMETERS | Inspiratory Pause Available | Yes |
| PERFORMANCE PARAMETERS | Expiratory Hold Available | Yes |
| PERFORMANCE PARAMETERS | Suction Control Option Available | Yes |
| PERFORMANCE PARAMETERS | Nasal CPAP Option Available | Yes |
| PERFORMANCE PARAMETERS | Auto PEEP Manoeuvre | Yes |
| PERFORMANCE PARAMETERS | Control Panel Lock | Yes |
| PERFORMANCE PARAMETERS | Facility for double lung ventilation | Yes |
| PERFORMANCE PARAMETERS | Integrated Air Compressor | Yes |
| VENTILATION MODES | PSV(Pressure supported ventilation) | Yes |
| VENTILATION MODES | P-CMV(Inspiration pressure control) | Yes |
| VENTILATION MODES | PC-AC With Expiratory Minimal volume | Yes |
| VENTILATION MODES | SIMV(Synchronized intermittent Mandatory Ventilation) with PCMV | Yes |
| VENTILATION MODES | ITT - Inspiratory Time Termination | Yes |
| VENTILATION MODES | CPAP:Continuos Positive Airway pressure Ventilation CPAP With backup Ventilation | Yes |
| VENTILATION MODES | High Frequency Oscillation Ventilator(HFOV) | Yes |
| PATIENT ASSESSMENT TOOLS | Capnography/Co2 Monitoring | Yes, No |
| PATIENT ASSESSMENT TOOLS | Volume Guarantee | Yes |
| PATIENT ASSESSMENT TOOLS | APRV | Yes |
| PATIENT ASSESSMENT TOOLS | Oxygen Therapy | Yes |
| ADDITIONAL CAPABILITIES | ETCO2 Inbuilt available | Yes |
| HUMIDIFIER | Disposable Neonatal breathing circuit (dual heated wire) | 20 |
| HUMIDIFIER | Auto Feed Humidification chamber Available | Yes |
| HUMIDIFIER | Disposable Neonatal breathing circuit with single heated wire provided for inspiratory Limb with Water trap in expiratory limb available | NA |
| ADDITIONAL PARAMETERS | Output Ports Type | USB |
| ADDITIONAL PARAMETERS | Remote Alarm Display Port | Yes, No |
| ADDITIONAL PARAMETERS | Reporting (Vent alarms and Patient Status) | Yes |
| ADDITIONAL PARAMETERS | View Reports on Display | Yes |
| ADDITIONAL PARAMETERS | Save Data to USB | Yes |
| ADDITIONAL PARAMETERS | Send Data Via Network | Yes |
| ADDITIONAL PARAMETERS | Display Type | LCD/LED/TFT |
| ADDITIONAL PARAMETERS | Display Size in Inches | ≥ 10, ≥ 12, ≥ 15 Or higher |
| ADDITIONAL PARAMETERS | Can be used For Patient Transport | No |
| ACCESSORIES | Nasal CPAP Kit | 10 |
| ACCESSORIES | Number of Disposable flow sensor | 20 |
| ACCESSORIES | Number of Reusable flow sensor | 3, 6, NA if Disposable |
| ACCESSORIES | Trolley with ventillator with supporting arm from same manufacturer | Yes |
| ACCESSORIES | Autoclavable exhalation valve/expiratory cassette | 2 |
| ACCESSORIES | Test Lung Available | Yes |
| POWER REQUIREMENTS | Operating time of battery in min | 60 |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5.0 |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
All India Institute Of Medical Sciences (aiims)
📍 NADIA, WEST BENGAL
Health Services
📍 AIZAWL, MIZORAM
N/a
📍 GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Sher-i-kashmir Institute Of Medical Sciences Srinagar
📍 SRINAGAR, JAMMU & KASHMIR
All India Institute Of Medical Sciences (aiims)
📍 NADIA, WEST BENGAL
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS