Non Refrigerated Centrifuge for General Purpose and research
Central Railway
Progress
Quantity
3
Bid Type
Two Packet Bid
Employees State Insurance Corporation has released a public tender for Non Refrigerated Centrifuge for General Purpose and research (Q3) in PATNA, BIHAR. Quantity: 3. Submission Deadline: 27-07-2026 13: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Non Refrigerated Centrifuge for General Purpose and research (Q3)
End-to-end support โ bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation ยท 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Central Railway
N/a
N/a
PUNE, MAHARASHTRA
N/a
GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Directorate Of Purchase And Stores
HYDERABAD, TELANGANA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Performance Parameters | Purpose | To Centrifuge different kinds of samples in different Labs and research Labs at room Temperature |
| Performance Parameters | Centrifuge design | Bench Top |
| Performance Parameters | Weight including Rotor in kgs | 40, 150 |
| Performance Parameters | Maximum RPM with no load | 20000, < 20000 |
| Performance Parameters | "Number of steps of RPM Variation available in the settings (correspondingly RCF also varies) " | 10, 100 |
| Performance Parameters | RPM setting accuracy | plus minus 5% |
| Performance Parameters | Type of Motor | Brushless(without carbons) |
| Performance Parameters | Type of lid lock | Both Manual and Electronic |
| Performance Parameters | Maximum Noise level when working at 1 meter distance in db | 56, 80 |
| Performance Parameters | Ambient operating Temperature range in Degree centigrade Celsius and Humidity Range | 0 to 50 and Relative humidity 15 to 90%, 0 to 40 and relative humidity is 15 to 80% |
| Performance Parameters | Rotor imbalance diagnostics and automatic stop if required | Yes |
| Performance Parameters | No of accelaration and decelarion profiles in built for rotor speed while automatic braking | "Programmable from 50 to 200 Seconds in Interval of 5 Seconds" |
| Performance Parameters | Maximum timer set point | 60 minutes |
| Performance Parameters | Configuration of Rotor supplied with centrifuge machine | Angle rotor |
| Performance Parameters | Rotor Feature With Reference to Autoclavability | Autoclavable Rotor @121 Degree Celsus |
| Performance Parameters | Type of Tubes which can be used with centrifuge machine | Polypropylene Centrifuge tubes and Glass centrifuge tubes |
| Performance Parameters | Size of rotor supplied with centrifuge | "24x15ml(for angle rotor) RPM 6000" |
| Performance Parameters | Maximum RCF | 4650, 1400 |
| Performance Parameters | Power supply | 230 Volts 50 Hz AC ยฑ 10%, 220V-240V 50Hz |
| Performance Parameters | Power consumption in watts | 220, 600, 350 |
| Performance Parameters | Accessories | Power supply cable, Instruction Manual |
| Performance Parameters | Warranty period in years | 5 |
| Material Parameters | Assembly Material for manufacture of Centrifuge | Die cast Aluminum, Aluminum sheet, Stainless Steel, CRC Steel,Plastic and Rubber, Steel armor plate with high-impact PC-ABS plastic cover |
| Material Parameters | "Lid Material of Centrifuge " | CRC Steel finish with powder coating or stove painting or ABS Plastic of injection moulding, Steel armor plate with high-impact PC-ABS plastic cover |
| Material Parameters | Body material of Centrifuge | C.R.C Steel Finish with Powder Coating/ Stove Painting |
| Material Parameters | Front Panel of centrifuge | CRC Steel finish with powder coating or stove painting or ABS Plastic of injection moulding, high-impact PC-ABS plastic |
| Material Parameters | Centrifuge Bowl material in Centrifuge | 304 Quality Stainless Steel Moulded |
| Additional Parameters | The Equipment shall be installed and demonstrated before Acceptance | Yes |
| Additional Parameters | Servo Controller Voltage Stabilizer supplied with Item | No |
| Additional Parameters | Servo stabilizer ratings in KVA | Not Supplied |
| Additional Parameters | Warranty of stabilizer in years | Not supplied |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
All India Institute Of Medical Sciences (aiims)
๐ JODHPUR, RAJASTHAN
Regional Centre For Biotechnology (rcb) Gurgaon
๐ FARIDABAD, HARYANA
N/a
๐ KAMRUP, ASSAM
State Forensic Science Laboratory Chhattisgarh
๐ RAIPUR, CHHATTISGARH
Government Medical College Bhavnagar
๐ BHAVNAGAR, GUJARAT
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS