Precision Air Conditioner PAC, 20 TR
Bid Type
Two Packet Bid
Indian Institute Of Technology (iit) invites bids for Precision Air Conditioner PAC, 20 TR, Factory accessories, Refrigerant copper piping with insulation, brazing, testing, Qty. as reqd. , in R. m. , Condensate drain piping, Qty. as reqd. , in R. m. , Double skin GI supply ducting with 25 mm insulation, Qty as reqd. , in sq. m. , Aluminum diffusers 900 CFM with dampers, Return air grille assembly, Electrical cabling power, control, earthing, Cu armoured, Civil foundation and outdoor plinth, Installation and alignment of PAC units, Testing, commissioning, and performance verification, Documentation, as-built drawings, and training in KAMRUP, ASSAM. Quantity: 24. Submission Deadline: 30-12-2025 16: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Precision Air Conditioner PAC, 20 TR , Factory accessories , Refrigerant copper piping with insulation, brazing, testing, Qty. as reqd., in R.m. , Condensate drain piping, Qty. as reqd., in R.m. , Double skin GI supply ducting with 25 mm insulation, Qty as reqd., in sq. m. , Aluminum diffusers 900 CFM with dampers , Return air grille assembly , Electrical cabling power, control, earthing, Cu armoured , Civil foundation and outdoor plinth , Installation and alignment of PAC units , Testing, commissioning, and performance verification , Documentation, as-built drawings, and training
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Precision Air Conditioner PAC, 20 TR
As per NIQ
Factory accessories
As per NIQ
Refrigerant copper piping with insulation, brazing, testing, Qty. as reqd., in R.m.
As per NIQ
Condensate drain piping, Qty. as reqd., in R.m.
As per NIQ
Double skin GI supply ducting with 25 mm insulation, Qty as reqd., in sq. m.
As per NIQ
Aluminum diffusers 900 CFM with dampers
As per NIQ
Return air grille assembly
As per NIQ
Electrical cabling power, control, earthing, Cu armoured
As per NIQ
Civil foundation and outdoor plinth
As per NIQ
Installation and alignment of PAC units
As per NIQ
Testing, commissioning, and performance verification
As per NIQ
Documentation, as-built drawings, and training
As per NIQ
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Precision Air Conditioner PAC, 20 TR | As per NIQ | 2 | nos | dpsinha | 45 | |
| 2 | Factory accessories | As per NIQ | 1 | lot | dpsinha | 45 | |
| 3 | Refrigerant copper piping with insulation, brazing, testing, Qty. as reqd., in R.m. | As per NIQ | 1 | lot | dpsinha | 45 | |
| 4 | Condensate drain piping, Qty. as reqd., in R.m. | As per NIQ | 1 | lot | dpsinha | 45 | |
| 5 | Double skin GI supply ducting with 25 mm insulation, Qty as reqd., in sq. m. | As per NIQ | 1 | lot | dpsinha | 45 | |
| 6 | Aluminum diffusers 900 CFM with dampers | As per NIQ | 8 | nos | dpsinha | 45 | |
| 7 | Return air grille assembly | As per NIQ | 2 | nos | dpsinha | 45 | |
| 8 | Electrical cabling power, control, earthing, Cu armoured | As per NIQ | 1 | lot | dpsinha | 45 | |
| 9 | Civil foundation and outdoor plinth | As per NIQ | 4 | nos | dpsinha | 45 | |
| 10 | Installation and alignment of PAC units | As per NIQ | 1 | job | dpsinha | 45 | |
| 11 | Testing, commissioning, and performance verification | As per NIQ | 1 | job | dpsinha | 45 | |
| 12 | Documentation, as-built drawings, and training | As per NIQ | 1 | lot | dpsinha | 45 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | AIR VIEW Under PMA | - | 12-12-2025 13:54:40 | |
| 2 | DS SYSTEMS PRIVATE LIMITED Under PMA | - | 30-12-2025 15:52:53 | |
| 3 | OMEGA E&A PRIVATE LIMITED Under PMA | - | 30-12-2025 15:57:38 |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | DS SYSTEMS PRIVATE LIMITED(MII) Under PMA | Item Categories : Precision Air Conditioner PAC, 20 TR,Factory accessories,Refrigerant copper piping with insulation, |
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS