Disconnecting and taking out defective under ground LT cable from trenches,Supply Laying testing an
Indian Army
HOOGHLY, WEST BENGAL
Bid Publish Date
06-May-2025, 4:41 pm
Bid End Date
30-May-2025, 11:00 am
Location
Progress
Quantity
14072
Indian Army announces a tender for Disconnecting and taking out defective under ground LT cable from trenches pole pipe floor wall etc in HOOGHLY, WEST BENGAL. Quantity: 14072. Submission Deadline: 30-05-2025 11: 00: 00. Last date to apply is approaching fast!
Main Document
BOQ
BOQ
GEM_CATEGORY_SPECIFICATION
GEM_CATEGORY_SPECIFICATION
GEM_CATEGORY_SPECIFICATION
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Army
HOOGHLY, WEST BENGAL
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Disconnecting and taking out defective under ground LT cable from trenches pole pipe floor wall etc | Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material all as specified and directed. (Excavation/earth work shall be measured & paid separately under relevant item of this schedule) | 5,320 | rm | [email protected] | 90 |
| 2 | Supply Laying testing XLPE sheathed size 4.0 core 10 sqmm. laid in trenches | Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 4.0 core 10 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified | 800 | rm | [email protected] | 90 |
| 3 | All as per BOQ Item No 2.00 here in before but of size 4.0 core 16 sqmm. complete all as specified | All as per BOQ Item No 2.00 here in before but of size 4.0 core 16 sqmm. ,complete all as specified | 1,250 | rm | [email protected] | 90 |
| 4 | All as per BOQ Item No 2.00 here in before but of size 3.5 core 25 sqmm. complete all as specified | All as per BOQ Item No 2.00 here in before but of size 3.5 core 25 sqmm. ,complete all as specified | 1,450 | rm | [email protected] | 90 |
| 5 | All as per BOQ Item No 2.00 here in before but of size 3.5 core 50 sqmm. complete all as specified | All as per BOQ Item No 2.00 here in before but of size 3.5 core 50 sqmm. ,complete all as specified | 500 | rm | [email protected] | 90 |
| 6 | All as per BOQ Item No 2.00 here in before but of size 3.5 core 70 sqmm. complete all as specified | All as per BOQ Item No 2.00 here in before but of size 3.5 core 70 sqmm. ,complete all as specified | 410 | rm | [email protected] | 90 |
| 7 | All as per BOQ Item No 2.00 here in before but of size 3.5 core 95 sqmm. complete all as specified | All as per BOQ Item No 2.00 here in before but of size 3.5 core 95 sqmm. ,complete all as specified | 250 | rm | [email protected] | 90 |
| 8 | Laying only and connecting XLPE sheathed PVC insulated screened steel strip of wire armoured electric power cable | Laying only and connecting XLPE sheathed,PVC insulated screened steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 4 core 10 sqmm . , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified | 120 | rm | [email protected] | 90 |
| 9 | All as per BOQ Item No 8.00 here in before but of size 4.0 core 16 sqmm. complete all as specified | All as per BOQ Item No 8.00 here in before but of size 4.0 core 16 sqmm. ,complete all as specified | 200 | rm | [email protected] | 90 |
| 10 | All as per BOQ Item No 8.00 here in before but of size 3.5 core 25 sqmm. complete all as specified | All as per BOQ Item No 8.00 here in before but of size 3.5 core 25 sqmm. ,complete all as specified | 250 | rm | [email protected] | 90 |
| 11 | All as per BOQ Item No 8.00 here in before but of size 3.5 core 50 sqmm. complete all as specified | All as per BOQ Item No 8.00 here in before but of size 3.5 core 50 sqmm. ,complete all as specified | 50 | rm | [email protected] | 90 |
| 12 | All as per BOQ Item No 8.00 here in before but of size 3.5 core 70 sqmm. complete all as specified | All as per BOQ Item No 8.00 here in before but of size 3.5 core 70 sqmm. ,complete all as specified | 40 | rm | [email protected] | 90 |
| 13 | Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, taking out and laying of cable etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil Note Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty Rs 500/ will be charged to contractor. In this GE decision will be final, conclusive and binding. | 1,053 | cum | [email protected] | 90 |
| 14 | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. | 578 | cum | [email protected] | 90 |
| 15 | Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. | 475 | cum | [email protected] | 90 |
| 16 | M and L Sand Cushioning dry in Trenches for protec tion of UG Cables below above and around the UG Cable | M&L Sand Cushioning (dry) in Trenches for protec tion of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE For the purpose of Payment, Punned thick ness of Sand Cushioning only shall be Measured and Paid ). | 345 | cum | [email protected] | 90 |
| 17 | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. | M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and as directed. | 34 | per 1000 nos | [email protected] | 90 |
| 18 | Supplying and fixing Galvanised mild steel pipe tubing light grade complete with all fittings of 80 mm bore dia | Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 80 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. | 30 | rm | [email protected] | 90 |
| 19 | Supplying and fixing Galvanised mild steel pipe tubing light grade complete with all fittings of 50 mm bore dia laid in trenches | Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. | 42 | rm | [email protected] | 90 |
| 20 | Supplying and fixing Galvanised mild steel pipe tubing light grade complete with all fittings of 100 mm bore dia | Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 100 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. | 12 | rm | [email protected] | 90 |
| 21 | M and L for Boring of horizontal hole under road pavement hardstanding suitable for passing through up to 80 mm bore | M & L for Boring of horizontal hole under road, pavement, hardstanding suitable for passing through up to 80 mm bore, complete all as specified. Note (i) One run of boring of horizontal hole will be measured as one unit length. (ii) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (iii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor. No extra cost will be paid on this account. (iv) Contractor has to get the survey of route, length and depth for boring before quoting the rate. | 84 | rm | [email protected] | 90 |
| 22 | M and L for straight through joint heat shrinkable complete suitable for LT 1100 Volt aluminium conductor cable of size3.5 4 x 10 16 sqmm and testing after jointing | M&L for straight through joint (heat shrinkable) complete suitable for LT 1100 Volt aluminium conductor cable of size3.5/4 x 10 16 sqmm and testing after jointing of following sizes of cables. Note Payment will be released only after submission of PV anf test certificate | 6 | each joint | [email protected] | 90 |
| 23 | M and L for straight through joint heat shrinkable complete suitable for LT 1100 Volt aluminium conductor cable of size3.5 4 x 25 50 sqmm | M&L for straight through joint (heat shrinkable) complete suitable for LT 1100 Volt aluminium conductor cable of size3.5/4 x 25 50 sqmm and testing after jointing of following sizes of cables, Note Payment will be released only after submission of PV anf test certificate | 6 | each joint | [email protected] | 90 |
| 24 | M and L for straight through joint heat shrinkable complete suitable for LT 1100 Volt aluminium conductor cable of size3.5 x 70 150 sqmm | M&L for straight through joint (heat shrinkable) complete suitable for LT 1100 Volt aluminium conductor cable of size3.5 x 70 150 sqmm and testing after jointing of following sizes of cables. Note Payment will be released only after submission of PV anf test certificate | 2 | each joint | [email protected] | 90 |
| 25 | Supplying and fixing High density polyethylene pipes HDPE of pressure rating 6 kgf cm2 complete with all fittings of 25 mm bore dia | Supplying and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 complete with all fittings of 25 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable/earth strip protection complete all as specified and directed. | 60 | rm | [email protected] | 90 |
| 26 | Supplying and fixing High density polyethylene pipes HDPE of pressure rating 6 kgf cm2 complete with all fittings of 40 mm bore dia | Supplying and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable/earth strip protection complete all as specified and directed. | 60 | rm | [email protected] | 90 |
| 27 | Supplying and fixing High density polyethylene pipes HDPE of pressure rating 6 kgf cm2 complete with all fittings of 50 mm bore dia | Supplying and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable/earth strip protection complete all as specified and directed. | 80 | rm | [email protected] | 90 |
| 28 | Supplying and fixing High density polyethylene pipes HDPE of pressure rating 6 kgf cm2 complete with all fittings of 100 mm bore dia | Supplying and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 complete with all fittings of 100 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable/earth strip protection complete all as specified and directed. | 12 | rm | [email protected] | 90 |
| 29 | Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground | Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI strip 32x6 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 40 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1 3 6) type C1 , Precast RCC (1 2 4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part I. NOTE 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI strip of 32x6mm including protection pipe, from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate | 34 | each set | [email protected] | 90 |
| 30 | Dismantling existing LT panels of any type any size carefully for reuse including necessary excavation demolition of concrete | Dismantling existing LT panels of any type, any size carefully for reuse including necessary excavation demolition of concrete,disconnecting of earthing,cable, taking out burn out lugs,MCCBs,bus bars,insulators and other connected works ,surface levelling etc. and reinstall the LT panels after repair/replacement of burn out lugs,MCCBs,bus bars,insulators, wiring etc including re connection of earthing,cables with new foundation of panels, brick works,PCC works etc complete including testing all as specified and as directed by Engr in charge.(NOTE Earth Work,brick works, foundation work, PCC, lugs, switch gear, metering devices, bus bar,insulators, cable for wiring etc will be Measured and Paid separately under relevant Items as supply only). | 8 | each job | [email protected] | 90 |
| 31 | Labour only for disconnecting isolating and taking out burned unserviceable lugs switchgear metering devices wiring bus bar etc from any type of panne | Labour only for disconnecting, isolating and taking out burned/unserviceable lugs, switchgear, metering devices, wiring, bus bar etc from any type of pannel/board and replacing the same with new ones including testing completee al as directed by Engr in Charge. Note (i) New parts will be measured and paid separately under respective items as supply only. (ii). The item will not be operated simultaniously alongwith the item No 30.00 | 20 | each parts | [email protected] | 90 |
| 32 | 06 sqmm to 16 sqmm | Supply only the followings ( to be incorporated against Item No 30.00 and 31.00 only) 06 sqmm to 16 sqmm | 18 | each | [email protected] | 90 |
| 33 | 25 sqmm to 50 sqmm | 25 sqmm to 50 sqmm | 18 | each | [email protected] | 90 |
| 34 | 70 sqmm to 95 sqmm | 70 sqmm to 95 sqmm | 21 | each | [email protected] | 90 |
| 35 | 120 sqmm to 240 sqmm | 120 sqmm to 240 sqmm | 12 | each | [email protected] | 90 |
| 36 | Epoxy type insulator upto 1100Volt for LT panel bus bar including nut bolts etc. complete all as specified and as directed. | Epoxy type insulator upto 1100Volt for LT panel bus bar including nut bolts etc. complete all as specified and as directed. | 20 | each | [email protected] | 90 |
| 37 | Single core stranded Copper conductor FRLS of size 16 sqmm including copper lugs at both ends | Single core stranded Copper conductor FRLS of size 16 sqmm including copper lugs at both ends | 40 | rm | [email protected] | 90 |
| 38 | Single core stranded Copper conductor FRLS of size 10 sqmm including copper lugs at both ends | Single core stranded Copper conductor FRLS of size 10 sqmm including copper lugs at both ends | 50 | rm | [email protected] | 90 |
| 39 | Aluminium Busbars electrolytic grade of as per site required Amps and KA rating bus bars with RYB and black colour coding including drilling | Aluminium Busbars electrolytic grade of as per site required Amps and KA rating, bus bars with RYB & black colour coding including drilling , cutting and suitable size of galvanised or codmium plated high tensile nuts, bolts and washers etc complete all as specified and directed. | 15 | kg | [email protected] | 90 |
| 40 | S and F of Framed work as in doors or gates of angle or other section with gusset plates rails braces etc. | S&F of Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete including takig out the existing. | 35 | kg | [email protected] | 90 |
| 41 | M and L for cross arms bracings supports clamps and back plates fabricated from structural steel sections includings nuts bolts washers | M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections includings nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts, in any shape of size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint including preparation of surfaces complete all as specified and directed | 1 | qtl | [email protected] | 90 |
| 42 | M and L for cement concrete 1 3 6 type C 2 using 40mm graded crushed stone aggregate as in pole foundation filling and mass concrete complete all as specified | M&L for cement concrete ( 1 3 6) type C 2 using 40mm graded crushed stone aggregate as in pole foundation, filling and mass concrete complete all as specified | 12 | cum | [email protected] | 90 |
| 43 | M and L for cement concrete 1 2 4 type B 1 using 20mm graded crushed stone aggregate as in coping of pole including weathering slightly rounded or chamfered | M&L for cement concrete ( 1 2 4) type B 1 using 20mm graded crushed stone aggregate as in coping of pole including weathering, slightly rounded or chamfered angles and throating, necessary formwork as directed complete all as specified | 5 | cum | [email protected] | 90 |
| 44 | M L brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius build | M/L brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM 1 6 complete all as specified and directed. | 15 | cum | [email protected] | 90 |
| 45 | M and L for 15mm thick in CM 1 4 rendering on brick or concrete surfaces finished fair and even on wall complete all as specified and directed. | M&L for 15mm thick in CM 1 4 rendering on brick or concrete surfaces finished fair and even on wall complete all as specified and directed. | 35 | per sqm | [email protected] | 90 |
| 46 | M and L for Hardcore of gauge n exc. 63 mm deposited spread and levelled in layers n exc. 15 cm thick watered and rammed to a true surface as specified and directed. | M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface as specified and directed. | 20 | cum | [email protected] | 90 |
| 47 | M and L SS pasivated Screw Bolts Machine Made with Hexagonal Head at one End and screwed the other Ends each screwed End to be fitted with Washers | M&L SS pasivated Screw Bolts (Machine Made) with Hexagonal Head at one End and screwed the other Ends, each screwed End to be fitted with Washers and One Hexagonal Nut, diameter of Shank 5 to 10mm Length of Bolt exc. 50mm complete all as specified and as directed. | 6 | kg | [email protected] | 90 |
| 48 | M and L for preparation of existing surface of LT Panel by srapping down peeled off old paint cleaning etc | M&L for preparation of existing surface of LT Panel by srapping down peeled off old paint, cleaning etc and applying Two coat of Siemens Grey Paint by using spray machine and Black paint on Angle Iron over a coat of red oxide primer complete all as specified and directed by Engr in Charge. | 50 | sqm | [email protected] | 90 |
| 49 | Supply and Fix Metal cable route indicator of height 750 mm MS Flat of 40 mm x 4 mm with Circular 100 mm | Supply and Fix Metal cable route indicator of height 750 mm MS Flat of 40 mm x 4 mm with Circular 100 mm diameter MS Sheet of minimun thickness 3 mm duly engraved LT CABLE including Aluminium paint over it and to be fixed 150 mm below ground level with PCC (1 3 6) (40 mm aggregate) of size 250x250x300 mm all as directed by Engr in Charge. | 85 | each | [email protected] | 90 |
| 50 | Taking down dismantling of unserviceable LT panels complete all as specified and directed by Engineer in Charge. | Taking down/dismantling of unserviceable LT panels complete all as specified and directed by Engineer in Charge. | 10 | each | [email protected] | 90 |
| 51 | S and F LED flood light 60 watt Min 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection | Supply & fixing LED flood light 60 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, BIS approved silicon zel fitted potted driver with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing witg toughened glass secondary lenses High efficiency long life LED package in integral module with lumen efficacy of 120 lm/W (Min) , electronic LED driver (SMPS based constant current supply) with Output Short circuit protection, Surge protection & other reliability test as per latest IS. LED operational voltage of 170 volts to 270 volts, frequency of 50 Hz, protection grade IP 66, IK 08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked Date of installation and Date of Procurement with marker pen. | 10 | each | [email protected] | 90 |
| 52 | Supply designing install testing commission 3 phase and neutral 415 volts outdoor type CPRI type tested having certification | Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC 61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.20m x 0.45m x 1.20m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL 7032 shade, protection class IP 66 fully compartmentalize design with 4 Nos of bus bar made The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding. The bus bars shall be supported on unbreakable, non hygroscopic SMC insulated pre wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB s, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1 3 6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1 6, rendering 1 6 on exposed surface and 100 mm thick PCC 1 3 6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories including taking out the existing one (A) Incoming MCCB 200 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics 100 prcnt Icu , service breaking capacity 36 KA 01 Nos. etc. | 2 | each | [email protected] | 90 |
| 53 | All as per BOQ Item No 57.00 here in before but of size 1.00m x 0.45m x 1.00m with the following incoming and outgoing accessories BUS BAR 4 Nos of bus bar | All as per BOQ Item No 57.00 here in before but of size 1.00m x 0.45m x 1.00m with the following incoming and outgoing accessories BUS BAR 4 Nos of bus bar made of aluminium, 250 Amps rated (electrical grade aluminium complying with the requirements of latest BIS, colour coded), busbar extensions for cable connections of electrolytic grade (A) Incoming MCCB 125 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics 100 % Icu , service breaking capacity 16 KA 01 Nos. (B) Outgoing (b) MCB 25 Amps rating, TPN ,C series 10 KA , 04 Nos. (c) Digital voltmeter 0 500 volt with selector switch 01 No (d) Digital amp meter 0 100 Amp with set of current transformer of suitable rating and selector switch 01 No (e) Indicator lamp (RYB) LED type 01 set (f) Control MCB 2.0 Amps SP 03. Nos | 7 | each | [email protected] | 90 |
| 54 | All as per BOQ Item No 57.00 here in before but but of size 1.20m x 0.45m x 1.20m with the following incoming and outgoing accessories | All as per BOQ Item No 57.00 here in before but but of size 1.20m x 0.45m x 1.20m with the following incoming and outgoing accessories BUS BAR 4 Nos of bus bar made of aluminium, 500 Amps rated (electrical grade aluminium complying with the requirements of latest BIS, colour coded), busbar extensions for cable connections of electrolytic grade (A) Incoming MCCB 250 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics 100 % Icu , service breaking capacity 36 KA 01 Nos. (B) Outgoing (b) MCCB 63 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics 100 % Icu , service breaking capacity 16 KA 02 Nos. (c) MCCB 40 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics 100 % Icu , service breaking capacity 16 KA 05 Nos (d) Astronomical Timer Switch 1 outlet 16 A 250V,vertical dial N/O contact,power supply 230V,50/60Hz,three position override switch ON AUTO OFF on front panel 01 Nos, 25A ,2 NO Contactor 3 phase, with 230V coil 01 Nos, 32 A MCB TPN 01Nos with suitable relay and other accessoris . (e) Digital voltmeter 0 500 volt with selector switch 01 No (f) Digital amp meter 0 100 Amp with set of current transformer of suitable rating and selector switch 01 No (g) Indicator lamp (RYB) LED type 01 set (h) Control MCB 2.0 Amps SP 03. Nos | 1 | each | [email protected] | 90 |
Extended Deadline
30-May-2025, 11:00 am
Opening Date
30-May-2025, 11:30 am
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | BAINS ENTERPRISES Under PMA | - | 28-05-2025 15:55:29 | Qualified |
| 2 | JAI ENGINEERS Under PMA | - | 29-05-2025 22:04:19 | Qualified |
| 3 | MR GURBACHAN SINGH Under PMA | - | 28-05-2025 16:26:37 | Qualified |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | JAI ENGINEERS(MII) Under PMA | ₹43,86,805 | Item Categories : Disconnecting and taking out defective under ground LT cable from trenches pole pipe floor wall etc |
| L2 | MR GURBACHAN SINGH (MII) Under PMA | ₹45,59,299 | Item Categories : Disconnecting and taking out defective under ground LT cable from trenches pole pipe floor wall etc |
| L3 | BAINS ENTERPRISES (MSE,MII)( MSE Social Category:General ) Under PMA | ₹46,27,799 | Item Categories : Disconnecting and taking out defective under ground LT cable from trenches pole pipe floor wall etc |
Key insights about WEST BENGAL tender market
The eligibility requirements include being a registered entity, having relevant experience in electrical work, and demonstrating compliance with quality governance standards in the industry. Bidders must also provide documentation verifying their capability to undertake the specified tasks efficiently.
Bidders need to provide various required certificates, such as:
To begin the registration process, interested bidders must ensure they are registered entities in the required field. They then need to submit an online application, along with necessary qualification documents and financial statements, before the specified deadline.
The payment terms will typically involve a percentage of the total contract value being paid upfront. Successful bidders will receive subsequent payments based on project milestones, which will be clearly defined in the contract agreement following the tender award.
The tender offers specific benefits for Micro, Small, and Medium Enterprises (MSEs), including potential financial support, relaxed eligibility criteria, and encouragement for participation, ensuring an inclusive bidding environment. This aligns with broader governmental strategies to promote growth among local small businesses.
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_CATEGORY_SPECIFICATION
GEM_CATEGORY_SPECIFICATION
GEM_CATEGORY_SPECIFICATION
GEM_GENERAL_TERMS_AND_CONDITIONS