Indian Army Stacker (V2) Tender SAGAR Madhya Pradesh 470001 – Loading Capacity, Battery, Warranty and Training 2026
Indian Army
SAGAR, MADHYA PRADESH
Bid Publish Date
31-Jan-2026, 10:29 am
Bid End Date
20-Feb-2026, 9:00 pm
EMD
₹72,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer) has released a public tender for Mobile Digital Radiography System (V2) (Q2) in PONDICHERRY, PUDUCHERRY. Quantity: 1. Submission Deadline: 20-02-2026 21: 00: 00. Download documents and apply online.
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Army
SAGAR, MADHYA PRADESH
E-municipalities - Eservices To Citizens And Employees Of Urban Local Bodies Of Uttar Pradesh
Hamirpur, UTTAR PRADESH
District Judge, Nayagarh, Nayagarh
NAYAGARH, ODISHA
Co-operative Department
SITAMARHI, BIHAR
Civil Defence Department Up
VARANASI, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| General | Product Description | Mobile Digital Radiography System |
| General | Scope of supply | Compact, easily transportable, digital mobile radiographic unit with articulated/telescopic arm |
| Digital Detector | Radiography Mode | Digital |
| Digital Detector | Number of detector | 1 |
| Digital Detector | Detector Material | Cesium Iodide |
| Digital Detector | Detector Size | 14 inches x 17 inches(wireless ) |
| Digital Detector | Matrix size | 2kx2k |
| Digital Detector | Pixel size in µm | <=150 |
| Digital Detector | Grey Scale resolution, bits/pixel | 14 or better |
| Digital Detector | DQE at 0 LP/mm | 65% or more |
| Digital Detector | Machine should have a detector storage compartment | Yes |
| Digital Detector | Weight of detector in kg | <=5 |
| Digital Detector | Detector should be designed and calibrated for General Radiography Purposes and must be fully integrated with the mobile unit including the controls | Yes |
| Digital Detector | Detector storage capacity | 100 images or more |
| Control panel for image acquisition | Image preview time in seconds | <=6 |
| Control panel for image acquisition | Control panel | Microprocessor controlled |
| Control panel for image acquisition | Automatic parameter selection | Yes |
| Control panel for image acquisition | Control panel entry | Touch screen |
| Control panel for image acquisition | Anatomic specific post processing | Yes |
| Control panel for image acquisition | Display | Digital display of mAs and KV and an electronic timer |
| Control panel for image acquisition | Inbuilt console should have touch TFT screen and control | Yes |
| Control panel for image acquisition | Console should enable to view the image, and provide post processing features, using touch screen | Yes |
| Control panel for image acquisition | Post processing features | Zoom, contrast and brightness, adjustment, panning annotate, mark and reporting |
| X Ray Generator and Tubes | High Frequency X-ray Generator Power in KW | 6 KW, 3.5 KW |
| X Ray Generator and Tubes | KV range | 40-110 |
| X Ray Generator and Tubes | Maximum mA | 100 @ 40 KVP |
| X Ray Generator and Tubes | Focal spot, mm | 0.8 - 2 |
| X Ray Generator and Tubes | Heat Capacity, KHU | 40-100 |
| X Ray Generator and Tubes | Anode Type | Stationary |
| X Ray Generator and Tubes | Anode RPM | NA for stationary |
| X Ray Generator and Tubes | Control Panel and X-Ray Tube | Yes |
| Tube Suspension | X Ray tube output should match with generator | Yes |
| Tube Suspension | Type of suspension | Articulated arm |
| Tube Suspension | Collimator Type | Manual |
| Tube Suspension | Collimator rotation | ± 90 degree with on off timer |
| Ergonomics | Unit should have small foot print | Yes |
| Ergonomics | Height of the column in cm (Should facilitate easy transportation in the lift and areas with small height doors etc) | <=150 |
| Ergonomics | Weight of mobile X Ray unit in kg | <=600 |
| Ergonomics | Cables should be concealed in the arm system | Yes |
| Ergonomics | Exposure release switch | Detachable with a cord of at least 5 meters. |
| Workstation | Dicom compatibility of work station | Yes |
| Workstation | Inbuilt console should have touch screen control | Yes |
| Workstation | Number of images which can be stored | 5000 or more |
| Workstation | Machine should be fully network ready and it should be possible to transfer images and patient data from and to hospital network using LAN connectivity or wireless LAN | Yes |
| Accessories | Stitching hardware and software | No |
| Accessories | Integration | DICOM 3.0 storage SOP Classes |
| Accessories | Lead Apron | Yes |
| Accessories | Thyroid shields provided | Yes |
| Accessories | Gonadsheet Male provided | Yes |
| Accessories | Gonad sheet Female provided | Yes |
| Accessories | Extractable measurable tape should be available | Yes |
| Accessories | Motorized movement for complete machine | No |
| Accessories | Castor wheel | Yes |
| Accessories | Unit should have effective breaking system for parking | Yes |
| Accessories | Power Requirements | 230 V 50 HZ Single phase -16 Ampls socket |
| Accessories | Machine should run on mains as well as battery supply | Yes |
| Accessories | Number of exposures which can be run on battery | 10 or more |
| Accessories | Battery should be able to provide power to the motor to move machine | No |
| Accessories | Battery charging time in hours | <=6 |
| Certifications | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| Certifications | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| Certifications | Certification for manufacturing unit | ISO:13485 (Latest) |
| Certifications | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| Certifications | Conformity to Safety Standards | IEC 60601-2-54 or equivalent BIS |
| Certifications | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| Certifications | AERB Type Approved Equipment | Yes |
| Certifications | Conformity to Indian Standard IS 7620- Part 1, Part 2, Part 3 | Yes |
| Miscellaneous Parameters | OEM/Reseller (if supplied to reseller shall ensure uninterputed availabilty of all spares for 10 years) | Yes |
| Miscellaneous Parameters | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| Miscellaneous Parameters | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| Miscellaneous Parameters | Demonstration of equipment and training to be provided after completing supplies before acceptance | Yes |
| Miscellaneous Parameters | Copies of reports and certifications to be furnished to buyer on demand at time of supplies | Yes |
| Miscellaneous Parameters | QA, QC and other tests as per NABH shall be carried out by OEM or authorized agency of OEM | Yes |
| Miscellaneous Parameters | Copies of all calibration and test reports to be submitted at the time of Supply of Machine | Yes |
| Warranty | Warranty in Years | 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Army
📍 UDHAMPUR, JAMMU & KASHMIR
Directorate Of Technical Education And Training
Indian Army
📍 INDORE, MADHYA PRADESH
Department Of Manipur Police
📍 IMPHAL WEST, MANIPUR
N/a
📍 SURENDRA NAGAR, GUJARAT
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS