National Institute Of Criminology And Forensic Science (nicfs) announces a tender for Gas Chromatography Mass Spectrometry (GC - MS) (Q3) in WEST DELHI, DELHI. Quantity: 2. Submission Deadline: 18-11-2025 13: 00: 00. Last date to apply is approaching fast!

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GAS CHROMATOGRAPH (GC) CONFIGURATION "GC Detectors inclusive in the scope of supply Flame Ionization Detector (FID)
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of FID in the System - inclusive in the scope of Supply 1
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of TCD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of ECD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of NPD/FTD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of FPD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of PID in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of PFPD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Inlets GC can Simultaneously Support 3
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Detectors (Ports) GC can Simultaneously Support 4
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Capillary Columns provided in GC - inclusive in the scope of Supply 2
GAS CHROMATOGRAPH (GC) CONFIGURATION Type of Capillary Column Non-Polar
GAS CHROMATOGRAPH (GC) CONFIGURATION "GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" 30.0
GAS CHROMATOGRAPH (GC) CONFIGURATION GC Packed Column Length 0.0
PERFORMANCE GC Detector Minimum Detection Level (MDL) < 1.4 pg C/s for FID
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Maximum Operating Temperature (GC Oven) upto 450 deg. C (2) Or higher
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Number of Oven Ramps / Plateaus for Temperature programming 20/21 or more
PNEUMATIC CONTROL Number of Injection Ports 1
PNEUMATIC CONTROL Maximum Injection Port heating Temperature upto 450 deg. C (2) Or higher
PNEUMATIC CONTROL Pressure Range upto 120 psi (2) Or higher
PNEUMATIC CONTROL Pressure set point Resolution (±)(psi) 0.001 Or lower
PNEUMATIC CONTROL Type of Sample Injection Port split / Splitless
PNEUMATIC CONTROL Split Ratio 7500:1
AUTO INJECTOR / AUTO SAMPLER Compatible Liquid Auto Sampler - inclusive in the scope of supply Yes
AUTO INJECTOR / AUTO SAMPLER Capacity of the Liquid Auto Sampler (Number of Vials) 150 Or higher
AUTO INJECTOR / AUTO SAMPLER Number of Injection Ports in the Liquid Auto Sampler 1
AUTO INJECTOR / AUTO SAMPLER Number of Channels in the Liquid Auto Sampler 0
AUTO INJECTOR / AUTO SAMPLER Liquid Auto Sampler Features Fully automated Liquid Auto Sampler, Injects with variable speed & varying syringe sizes, Operates through Software (Software inclusive in the scope of supply)
HEAD SPACE SAMPLER Compatible Head Space Sampler- inclusive in the scope of supply Yes
HEAD SPACE SAMPLER Capacity of the Head Space Sampler Carousel (number of Vials) 12 or better
HEAD SPACE SAMPLER Head Space Sampler Temperature Range Upto 200 deg. C or better
PYROLYZER SYSTEM Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply No
MASS SPECTROPHOTOMETER (MS) SYSTEM Ionization modes Electron Ionization (EI)
MASS SPECTROPHOTOMETER (MS) SYSTEM Detector Type Electron Multiplier
MASS SPECTROPHOTOMETER (MS) SYSTEM Operating modes Both Full Scan & SIM Modes
PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS) SYSTEM Sensitivity (S/N Ratio) in full scan 1500:1 with 1 pg/microliter OFN
SALIENT FEATURES OF GC-MS "Salient Featutes of GC-MS (Select applicable features Only)" Automatic leak testing/detection of Pneumatics, Direct setting of split flow rates and ratios, Flow sensor for control & storage of split ratio, Split and Septum Purge gases, Able to direct inject onto packed and wide-bore capillary columns, Oven power turns-off automatically when the lid/door is opened, Over Heat Protection, Display Unit with built-in Key Board, Controlled by External PC System, Programmable ion source temperature, System includes variety of auto tune algorithms to tune the instrument for maximum sensitivity or for specific target compounds, EI source is inert to active compounds and programmable, EI Source have a dual filament design with automatic selection of other filament if one fails during analysis;
LIBERARIES Libraries for GC-MS NIST Library for MS - Licensed version - 2017 or latest
SOFTWARE "Software Features (Select Applicable Features only)" Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters, Interface with Multiple GCs through the comprehensive real-time monitoring and diagnostic software, Real time notification via advisories and indicators, Counters, Chromatographic attributes, Instrument diagnostics, Access to maintenance information, Access to maintenance, run and event logs, Retention Time - Locking module for analyzing target compounds in complex matrices
DESKTOP WORKSTATION Desktop workstation Suitable to GC-MS - inclusive in the scope of supply Yes
DESKTOP WORKSTATION Graphics Card Memory Size 4.0
ONLINE UPS UPS Provided in the Scope of Supply Yes
ONLINE UPS Rating of online UPS(KVA) 7.5 KVA
ONLINE UPS Backup time of online UPS 60.0
GENERIC Built-in Display Yes
GENERIC Connectivity interface USB
GENERIC Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously No
GENERIC Back Flash - inclusive in the scope of supply NA
ACESSORIES Gas Supply inclusive in the scope of supply Nitrogen, Hydrogen, Helium, Zero Air
ACESSORIES Number of Cyliners of each type supplied - inclusive in the scope of supply 1
ACESSORIES Gas cylinders certified by PESO Yes
ACESSORIES Regulator - inclusive in the scope of supply Dual Stage Regulator
ACESSORIES "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" Gas purification panel for all Gases with moisture trap, Hydrocarbon trap & Oxygen trap, Syringe for manual injection x 05 nos, Auto Sampler Vials x 1000 vials with screw cap, Graphite ferrules x 10 nos, Vessel ferrules x 10 nos, Septa for injector x 100 nos, Inlet liner for splitles x 4 nos, Inlet liner for split x 4 nos, O-rings x 10 nos. of each type, Column Cutter x 2 nos, Gas tube Cutter x 2 nos, Tool Kit x 1 no., Syringe for Auto Sampler injection x 10 nos, EI filaments x 5 nos
ENVIRONMENTAL Operating Humidity (RH) (%) at 40 degree C 85.0 - 95.0 Or higher
INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING Warranty on equipment 2.0
INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING Number of days onsite training provided 5.0
CERTIFICATION / TEST REPORT "Availability of UL/CE Certificate as per EN 61010- 1:2010 Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" Yes
CERTIFICATION / TEST REPORT Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use Yes
CERTIFICATION / TEST REPORT Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification No

AI-Powered Bidder Prediction

Companies most likely to bid

Unlock Bidder Insights

AI predictions on likely bidders

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer