National Institute Of Criminology And Forensic Science (nicfs) announces a tender for Gas Chromatography Mass Spectrometry (GC - MS) (Q3) in WEST DELHI, DELHI. Quantity: 2. Submission Deadline: 18-11-2025 13: 00: 00. Last date to apply is approaching fast!
Tender Notice for Gas Chromatography Mass Spectrometry (GC - MS) in WEST DELHI, DELHI
Posted
28 Oct 2025, 11:24 am
Deadline
18 Nov 2025, 01:00 pm
EMD
₹5,40,000
Location
Progress
Quantity
2
Bid Type
Two Packet Bid
Technical Specifications
1 Item
Item #1 Details
View Catalog| Category | Specification | Requirement |
|---|---|---|
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Detectors inclusive in the scope of supply | Flame Ionization Detector (FID) |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FID in the System - inclusive in the scope of Supply | 1 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of TCD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of ECD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of NPD/FTD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FPD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PID in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PFPD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Inlets GC can Simultaneously Support | 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Detectors (Ports) GC can Simultaneously Support | 4 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Capillary Columns provided in GC - inclusive in the scope of Supply | 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Type of Capillary Column | Non-Polar |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" | 30.0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | GC Packed Column Length | 0.0 |
| PERFORMANCE | GC Detector Minimum Detection Level (MDL) | < 1.4 pg C/s for FID |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Maximum Operating Temperature (GC Oven) | upto 450 deg. C (2) Or higher |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Number of Oven Ramps / Plateaus for Temperature programming | 20/21 or more |
| PNEUMATIC CONTROL | Number of Injection Ports | 1 |
| PNEUMATIC CONTROL | Maximum Injection Port heating Temperature | upto 450 deg. C (2) Or higher |
| PNEUMATIC CONTROL | Pressure Range | upto 120 psi (2) Or higher |
| PNEUMATIC CONTROL | Pressure set point Resolution (±)(psi) | 0.001 Or lower |
| PNEUMATIC CONTROL | Type of Sample Injection Port | split / Splitless |
| PNEUMATIC CONTROL | Split Ratio | 7500:1 |
| AUTO INJECTOR / AUTO SAMPLER | Compatible Liquid Auto Sampler - inclusive in the scope of supply | Yes |
| AUTO INJECTOR / AUTO SAMPLER | Capacity of the Liquid Auto Sampler (Number of Vials) | 150 Or higher |
| AUTO INJECTOR / AUTO SAMPLER | Number of Injection Ports in the Liquid Auto Sampler | 1 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Channels in the Liquid Auto Sampler | 0 |
| AUTO INJECTOR / AUTO SAMPLER | Liquid Auto Sampler Features | Fully automated Liquid Auto Sampler, Injects with variable speed & varying syringe sizes, Operates through Software (Software inclusive in the scope of supply) |
| HEAD SPACE SAMPLER | Compatible Head Space Sampler- inclusive in the scope of supply | Yes |
| HEAD SPACE SAMPLER | Capacity of the Head Space Sampler Carousel (number of Vials) | 12 or better |
| HEAD SPACE SAMPLER | Head Space Sampler Temperature Range | Upto 200 deg. C or better |
| PYROLYZER SYSTEM | Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply | No |
| MASS SPECTROPHOTOMETER (MS) SYSTEM | Ionization modes | Electron Ionization (EI) |
| MASS SPECTROPHOTOMETER (MS) SYSTEM | Detector Type | Electron Multiplier |
| MASS SPECTROPHOTOMETER (MS) SYSTEM | Operating modes | Both Full Scan & SIM Modes |
| PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS) SYSTEM | Sensitivity (S/N Ratio) in full scan | 1500:1 with 1 pg/microliter OFN |
| SALIENT FEATURES OF GC-MS | "Salient Featutes of GC-MS (Select applicable features Only)" | Automatic leak testing/detection of Pneumatics, Direct setting of split flow rates and ratios, Flow sensor for control & storage of split ratio, Split and Septum Purge gases, Able to direct inject onto packed and wide-bore capillary columns, Oven power turns-off automatically when the lid/door is opened, Over Heat Protection, Display Unit with built-in Key Board, Controlled by External PC System, Programmable ion source temperature, System includes variety of auto tune algorithms to tune the instrument for maximum sensitivity or for specific target compounds, EI source is inert to active compounds and programmable, EI Source have a dual filament design with automatic selection of other filament if one fails during analysis; |
| LIBERARIES | Libraries for GC-MS | NIST Library for MS - Licensed version - 2017 or latest |
| SOFTWARE | "Software Features (Select Applicable Features only)" | Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters, Interface with Multiple GCs through the comprehensive real-time monitoring and diagnostic software, Real time notification via advisories and indicators, Counters, Chromatographic attributes, Instrument diagnostics, Access to maintenance information, Access to maintenance, run and event logs, Retention Time - Locking module for analyzing target compounds in complex matrices |
| DESKTOP WORKSTATION | Desktop workstation Suitable to GC-MS - inclusive in the scope of supply | Yes |
| DESKTOP WORKSTATION | Graphics Card Memory Size | 4.0 |
| ONLINE UPS | UPS Provided in the Scope of Supply | Yes |
| ONLINE UPS | Rating of online UPS(KVA) | 7.5 KVA |
| ONLINE UPS | Backup time of online UPS | 60.0 |
| GENERIC | Built-in Display | Yes |
| GENERIC | Connectivity interface | USB |
| GENERIC | Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously | No |
| GENERIC | Back Flash - inclusive in the scope of supply | NA |
| ACESSORIES | Gas Supply inclusive in the scope of supply | Nitrogen, Hydrogen, Helium, Zero Air |
| ACESSORIES | Number of Cyliners of each type supplied - inclusive in the scope of supply | 1 |
| ACESSORIES | Gas cylinders certified by PESO | Yes |
| ACESSORIES | Regulator - inclusive in the scope of supply | Dual Stage Regulator |
| ACESSORIES | "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" | Gas purification panel for all Gases with moisture trap, Hydrocarbon trap & Oxygen trap, Syringe for manual injection x 05 nos, Auto Sampler Vials x 1000 vials with screw cap, Graphite ferrules x 10 nos, Vessel ferrules x 10 nos, Septa for injector x 100 nos, Inlet liner for splitles x 4 nos, Inlet liner for split x 4 nos, O-rings x 10 nos. of each type, Column Cutter x 2 nos, Gas tube Cutter x 2 nos, Tool Kit x 1 no., Syringe for Auto Sampler injection x 10 nos, EI filaments x 5 nos |
| ENVIRONMENTAL | Operating Humidity (RH) (%) at 40 degree C | 85.0 - 95.0 Or higher |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Warranty on equipment | 2.0 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of days onsite training provided | 5.0 |
| CERTIFICATION / TEST REPORT | "Availability of UL/CE Certificate as per EN 61010- 1:2010 Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" | Yes |
| CERTIFICATION / TEST REPORT | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes |
| CERTIFICATION / TEST REPORT | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | No |
AI-Powered Bidder Prediction
Companies most likely to bid
Unlock Bidder Insights
AI predictions on likely bidders
Required Documents
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Download FREE!
Access all tender documents at no cost
Documents 7
GeM-Bidding-8518814.pdf
Main Document
Other Documents
OTHER
CATALOG-Specification-1
CATALOG Specification
Other Documents
OTHER
Other Documents
OTHER
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS
GeM-Bidding-8518814.pdf
Main Document
Other Documents
OTHER
CATALOG-Specification-1
CATALOG Specification
Other Documents
OTHER
Other Documents
OTHER
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS