M and L for Point wiring with FRRLS copper conductor cables,All as item No 1 above but point wiring
Indian Army
VADODARA, GUJARAT
Progress
Quantity
162
Category
M and L for Removal and Reinstalltion of Elevated Taxiway
Bid Type
Two Packet Bid
Public procurement opportunity for Indian Army M and L for Removal and Reinstalltion of Elevated Taxiway, M and L for Removal and Reinstalltion of Transformer Housing Box, M and L for Removal and Reinstalltion of 45W 6 point 6 oblique 6 point 6A isolating Transformer complete, S and F Dummy plate with Gasket and Bolts complete all as specified and as directed, S and F cable jointing kit for 5 KV Eathed grade cable straight through heat shrink type joint complete with jointing material, M and L for high denisty polyethylene HDPE pipes for pressure rating 6 kg sq cm of size 40mm complete all as specified, M and L for 4 mm dia SWGGI wire suitable lugs for termination inside tranformer housing complete all as specified, M and L for earthing complete with galvanside steel earth plate electrode 600 into 600 into 6 point 0 mm thick burried directly in ground earth pit not less that 2 point 25m deep below normal, Excavation in trenches not exceeding 1 point 5 mtr wide and n exc 1 point 5 mtr in depth in any type of soil and gettting out for taking up laying of GI PPR CI pipes all as specified, Returning filling in inculding spreading leveling watering and well rammimg in layers not exc 25 cm thick all as directed, Removal of surplus soil to a distance n exc 50 mtr and deposited where directed at a level n exc 1 point 5 mtr above the starting point, Labour only for removing of mud from trenches removal and re laying of cable and GI HDPE pipe complete all as specified in VADODARA, GUJARAT. Quantity: 162 issued by. Submission Deadline: 13-10-2025 13: 00: 00. View full details and respond.
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Army
VADODARA, GUJARAT
Indian Army
Indian Army
NORTH 24 PARGANAS, WEST BENGAL
Indian Army
VADODARA, GUJARAT
Indian Army
HOOGHLY, WEST BENGAL
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | M and L for Removal and Reinstalltion of Elevated Taxiway | M and L for Removal and Reinstalltion of Elevated Taxiway Lights complete all as specified and as directed | 2 | each | agetbaroda | 30 |
| 2 | M and L for Removal and Reinstalltion of Transformer Housing Box | M and L for Removal and Reinstalltion of Transformer Housing Box complete all as specified and as directed | 2 | each | agetbaroda | 30 |
| 3 | M and L for Removal and Reinstalltion of 45W 6 point 6 oblique 6 point 6A isolating Transformer complete | M and L for Removal and Reinstalltion of 45W 6 point 6 oblique 6 point 6A isolating Transformer complete all as specified and as directed | 2 | each | agetbaroda | 30 |
| 4 | S and F Dummy plate with Gasket and Bolts complete all as specified and as directed | S and F Dummy plate with Gasket and Bolts complete all as specified and as directed | 2 | each | agetbaroda | 30 |
| 5 | S and F cable jointing kit for 5 KV Eathed grade cable straight through heat shrink type joint complete with jointing material | S and F cable jointing kit for 5 KV Earthed grade cable straight through heat shrink type joint complete with jointing material | 2 | each | agetbaroda | 30 |
| 6 | M and L for high denisty polyethylene HDPE pipes for pressure rating 6 kg sq cm of size 40mm complete all as specified | and accessories suitable for AFLS primary cable connectors of cable size upto 16 sqmm into 1C complete all as specified as directed | 40 | rm | agetbaroda | 30 |
| 7 | M and L for 4 mm dia SWGGI wire suitable lugs for termination inside tranformer housing complete all as specified | M and L for high denisty polyethylene HDPE pipes for pressure rating 6 kg sq cm of size 40mm complete all as specified and directed | 40 | rm | agetbaroda | 30 |
| 8 | M and L for earthing complete with galvanside steel earth plate electrode 600 into 600 into 6 point 0 mm thick burried directly in ground earth pit not less that 2 point 25m deep below normal | M and L for 4 mm dia SWGGI wire suitable lugs for termination inside transformer housing complete all as specified and as directed | 2 | each | agetbaroda | 30 |
| 9 | Excavation in trenches not exceeding 1 point 5 mtr wide and n exc 1 point 5 mtr in depth in any type of soil and gettting out for taking up laying of GI PPR CI pipes all as specified | M and L for earthing complete with galvanised steel earth plate electrode 600 into 600 into 6 point 0 mm thick buried directly in ground earth pit not less that 2 point 25m deep below normal ground level connected to galvanised earth lead wire 4 point 0 mm dia by means of nuts bolts and and washers of GI as shown in electrical plate No 3 of SI Part I connected to earthling test point all as specified and including necessary earth pit PCC 1 3 6 chamber be 50mm thick PCC 1 2 4 chamber cover with 6mm dia mild steel reinforcement of 10 cm cc spacing both ways in lieu of CI cover watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 20 mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia upto 7 point 5 from the earth plate electrode and refilling of soil etc including necessary excavating and earth work in any strata and PCC chamber complete as specified and directed including demolition of old and unserviceable existing earth pit and removing from site | 9 | cum | agetbaroda | 30 |
| 10 | Returning filling in inculding spreading leveling watering and well rammimg in layers not exc 25 cm thick all as directed | Excavation in trenches not exceeding 1 point 5 mtr wide and n exc 1 point 5 mtr in depth in any type of soil and getting out for taking up laying of GI PPR CI pipes all as specified and directed | 8 | cum | agetbaroda | 30 |
| 11 | Removal of surplus soil to a distance n exc 50 mtr and deposited where directed at a level n exc 1 point 5 mtr above the starting point | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm thick all as directed | 1 | cum | agetbaroda | 30 |
| 12 | Labour only for removing of mud from trenches removal and re laying of cable and GI HDPE pipe complete all as specified | Removal of surplus soil to a distance n exc 50 mtr and deposited where directed at a level n exc 1 point 5 mtr above the starting point | 52 | rm | agetbaroda | 30 |
Discover companies most likely to bid on this tender
Experience Criteria
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS