Bid Publish Date
24-Jul-2026, 10:58 am
Bid End Date
24-Aug-2026, 11:00 am
EMD
₹20,000
Location
Progress
Quantity
2440
Category
HT galvanized Wire 2.5 mm
Bid Type
Two Packet Bid
Public procurement opportunity for Indian Army HT galvanized Wire 2. 5 mm, Spring poles 50 mm dia 3. 2 thickness and 3 mtr, Supporting poles 50 mm dia 3. 2 mm thickness and 3 mtr, Fixed poles 50mm dia 3. 2 mm thickness and 3 mtr, CP Insulator, PP Insulator, Wire Tightener, Tension Spring, Secondary battery 12V, 100 AHC solar charging type, Solar Energizer Machine 10 KVA, Solar Panel 100W 12V with charge controller 10A 12V, Gate handle with spring, GI Binding wire, Earthing rod 6. 5 Feet GI 200 mm OD, HDPE electrical concealed pipe, Power cable 2 Core 2. 5 Sq mm, Warning boards, Casting Material, Installation Labour and TN Cost in DARJEELING, WEST BENGAL. Quantity: 2440 issued by. Submission Deadline: 24-08-2026 11: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
HT galvanized Wire 2.5 mm , Spring poles 50 mm dia 3.2 thickness and 3 mtr , Supporting poles 50 mm dia 3.2 mm thickness and 3 mtr , Fixed poles 50mm dia 3.2 mm thickness and 3 mtr , CP Insulator , PP Insulator , Wire Tightener , Tension Spring , Secondary battery 12V, 100 AHC solar charging type , Solar Energizer Machine 10 KVA , Solar Panel 100W 12V with charge controller 10A 12V , Gate handle with spring , GI Binding wire , Earthing rod 6.5 Feet GI 200 mm OD , HDPE electrical concealed pipe , Power cable 2 Core 2.5 Sq mm , Warning boards , Casting Material , Installation Labour and TN Cost
Advisory Bank
PUNJAB NATIONAL BANK
ePBG Percentage
5%
ePBG Duration (Months)
30
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Darjeeling
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| - | Darjeeling | Darjeeling | - | - | 650 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
HT galvanized Wire 2.5 mm
Hot Dip galvanized High tensile Corrosion resistant Continuous length preferred
Spring poles 50 mm dia 3.2 thickness and 3 mtr
ERW Steel tube OD-50 mm Thickness 3.2 mm Length-3 mtr provision for foundation grouting
Supporting poles 50 mm dia 3.2 mm thickness and 3 mtr
Minimum 150 Kg lateral load, Pre drilled for insulator fixing salt spray resistance 5000 hours, length 3 mtrs
Fixed poles 50mm dia 3.2 mm thickness and 3 mtr
GI steel 50 mm OD Thickness 3.2 mm Length 3 mtrs anti corrosion treatment bitumen coating for under ground portion wind resistance suitable for 120 km/h wind.
CP Insulator
HDPE/Porcelain, Tracking resistance 600v, Dielectric strength 20Kv
PP Insulator
Mechanical strength 50 Kg pull load, Electrical insulation 10KV Suitable for line wire Crack resistant outdoor grade
Wire Tightener
Hot dip galvanized steel Ratchet/ rotary type Load capacity Min 700Kg Rust proof coating Minimum 1.5 for fine adjustment anti slip locking mechanism
Tension Spring
Oil tempered spring steel extension range 150 mm load capacity 100 kg outdoor grade
Secondary battery 12V, 100 AHC solar charging type
Tubular/VRLA/GEL solar compatible, 100 Ah at C10, Depth of discharge less 80 percentage, self discharge more than 3 percentage per month, backup 48 hours operation, IS 1651or IEC 61427
Solar Energizer Machine 10 KVA
Output voltage 10KVA output energy 10 joules pulse interval 1 to 1.5 seconds, coverage minimum 2 Km multi strand fencing Input voltage 12V DC Short circuit protection, Lighting protection and reverse IP 65 weatherproof
Solar Panel 100W 12V with charge controller 10A 12V
Mono Crystalline preferred open circuit voltage 21V, short circuit current 6A, Tempered anti reflective, Charge controller 10A PWM MPPT, Protections overcharge, Deep discharge and reverse current.
Gate handle with spring
Insulation rating 10KV, Mechanical strength 100Kg, Hook type Stainless steel Handle Material UV Stabilized ABS
GI Binding wire
No cracking on bending, 2 mm dia, rust resistant, binding and fastening
Earthing rod 6.5 Feet GI 200 mm OD
Earthing Resistance 5 Ohms, Rod Material GI/Copper bonded, Diameter 20 mm, Installation minimum 2 rods interconnected, Backfill charcoal and salt mixture
HDPE electrical concealed pipe
Material HDPE, Diameter-As per cable size,
Power cable 2 Core 2.5 Sq mm
conductor resistance, As per IS 8130, Conductor Copper, Protection flame retardant
Warning boards
MS ACP Polymer, Minimum 300 x 200 mm, Marking Danger Electric Fence, Reflective paint, Type IV reflective sheet
Casting Material
Cement concreter M20 grade minimum Mix Ration 1 or 1 ratio 5 or 3 Cement OPC 53 grade, pole foundation, clean reiver sand, Zone II preferred, 20 mm nominal size, crushed angular aggregate
Installation Labour and TN Cost
Wire Height Multi Strand 6 to10 Lines Spacing between wires 150 to 200 mm Voltate test 7 kv across fence, Earthing test Mandatory before commisioning Complete erection and commissioning Testing Voltage and functionality testing, Transport Inclusive of all lofistics, Warrenty Minimum 24 months.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | HT galvanized Wire 2.5 mm | Hot Dip galvanized High tensile Corrosion resistant Continuous length preferred | 650 | kg | purchaseoffr16 | 15 | |
| 2 | Spring poles 50 mm dia 3.2 thickness and 3 mtr | ERW Steel tube OD-50 mm Thickness 3.2 mm Length-3 mtr provision for foundation grouting | 120 | nos | purchaseoffr16 | 15 | |
| 3 | Supporting poles 50 mm dia 3.2 mm thickness and 3 mtr | Minimum 150 Kg lateral load, Pre drilled for insulator fixing salt spray resistance 5000 hours, length 3 mtrs | 70 | nos | purchaseoffr16 | 15 | |
| 4 | Fixed poles 50mm dia 3.2 mm thickness and 3 mtr | GI steel 50 mm OD Thickness 3.2 mm Length 3 mtrs anti corrosion treatment bitumen coating for under ground portion wind resistance suitable for 120 km/h wind. | 70 | nos | purchaseoffr16 | 15 | |
| 5 | CP Insulator | HDPE/Porcelain, Tracking resistance 600v, Dielectric strength 20Kv | 350 | nos | purchaseoffr16 | 15 | |
| 6 | PP Insulator | Mechanical strength 50 Kg pull load, Electrical insulation 10KV Suitable for line wire Crack resistant outdoor grade | 750 | nos | purchaseoffr16 | 15 | |
| 7 | Wire Tightener | Hot dip galvanized steel Ratchet/ rotary type Load capacity Min 700Kg Rust proof coating Minimum 1.5 for fine adjustment anti slip locking mechanism | 140 | nos | purchaseoffr16 | 15 | |
| 8 | Tension Spring | Oil tempered spring steel extension range 150 mm load capacity 100 kg outdoor grade | 200 | nos | purchaseoffr16 | 15 | |
| 9 | Secondary battery 12V, 100 AHC solar charging type | Tubular/VRLA/GEL solar compatible, 100 Ah at C10, Depth of discharge less 80 percentage, self discharge more than 3 percentage per month, backup 48 hours operation, IS 1651or IEC 61427 | 2 | nos | purchaseoffr16 | 15 | |
| 10 | Solar Energizer Machine 10 KVA | Output voltage 10KVA output energy 10 joules pulse interval 1 to 1.5 seconds, coverage minimum 2 Km multi strand fencing Input voltage 12V DC Short circuit protection, Lighting protection and reverse IP 65 weatherproof | 2 | nos | purchaseoffr16 | 15 | |
| 11 | Solar Panel 100W 12V with charge controller 10A 12V | Mono Crystalline preferred open circuit voltage 21V, short circuit current 6A, Tempered anti reflective, Charge controller 10A PWM MPPT, Protections overcharge, Deep discharge and reverse current. | 4 | nos | purchaseoffr16 | 15 | |
| 12 | Gate handle with spring | Insulation rating 10KV, Mechanical strength 100Kg, Hook type Stainless steel Handle Material UV Stabilized ABS | 6 | nos | purchaseoffr16 | 15 | |
| 13 | GI Binding wire | No cracking on bending, 2 mm dia, rust resistant, binding and fastening | 15 | kg | purchaseoffr16 | 15 | |
| 14 | Earthing rod 6.5 Feet GI 200 mm OD | Earthing Resistance 5 Ohms, Rod Material GI/Copper bonded, Diameter 20 mm, Installation minimum 2 rods interconnected, Backfill charcoal and salt mixture | 6 | nos | purchaseoffr16 | 15 | |
| 15 | HDPE electrical concealed pipe | Material HDPE, Diameter-As per cable size, | 3 | bdl | purchaseoffr16 | 15 | |
| 16 | Power cable 2 Core 2.5 Sq mm | conductor resistance, As per IS 8130, Conductor Copper, Protection flame retardant | 10 | roll | purchaseoffr16 | 15 | |
| 17 | Warning boards | MS ACP Polymer, Minimum 300 x 200 mm, Marking Danger Electric Fence, Reflective paint, Type IV reflective sheet | 40 | nos | purchaseoffr16 | 15 | |
| 18 | Casting Material | Cement concreter M20 grade minimum Mix Ration 1 or 1 ratio 5 or 3 Cement OPC 53 grade, pole foundation, clean reiver sand, Zone II preferred, 20 mm nominal size, crushed angular aggregate | 1 | job | purchaseoffr16 | 15 | |
| 19 | Installation Labour and TN Cost | Wire Height Multi Strand 6 to10 Lines Spacing between wires 150 to 200 mm Voltate test 7 kv across fence, Earthing test Mandatory before commisioning Complete erection and commissioning Testing Voltage and functionality testing, Transport Inclusive of all lofistics, Warrenty Minimum 24 months. | 1 | job | purchaseoffr16 | 15 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS