Bid Publish Date
20-Aug-2026, 9:51 am
Bid End Date
04-Sep-2026, 10:00 am
EMD
₹11,920
Progress
Public procurement opportunity for Cement Corporation Of India Limited (cci) Vibrometer - Induced Ground Vibration Monitoring Instrument (Q3). Quantity: 1 issued by. Submission Deadline: 04-09-2026 10: 00: 00. View full details and respond.
Quantity
1
Bid Type
Two Packet Bid
Bid Validity
120 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
3 Days
EMD Required
Yes
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Min. Avg. Annual Turnover
178
Past Performance
10 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Vibrometer - Induced Ground Vibration Monitoring Instrument (Q3)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
5
Payment Timelines
Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
45
Delivery Locations
1
Delivery Cities
Vikarabad
Delivery Pincodes
501158
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Maddala Suresh | 501158,Tandur Cement factory CCI Tandur Post Karankote PIN- 501158 | Vikarabad | Telangana | 501158 | 1 | 45 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| Certification | Compliance to Standard for Microphone | ISEE 2011, IEC 61672 Class 1, ISEE2017 |
| Certification | Compliance to Standard for Geophone | DIN, ISEE |
| Certification | Warranty | 1, 2, 3 Or higher |
| Construction | Width of Data Monitoring & Control Unit(mm) | 90-110 |
| Construction | Height of Data Monitoring & Control Unit(mm) | 30-50, 70-90 |
| Construction | Length of wire for geophone assembly(meter) | 5-6 |
| Construction | Type of Geophone (Application based) | Surface Fixed |
| Construction | Length of Data Monitoring & Control Unit(mm) | 110-130, 130-150, 150-170 |
| Construction | Length of wire for microphone assembly(meter) | 2-3 |
| Seismic Vibration Monitoring | Resolution of Seismic Velocity(mm/sec) | 0.003-0.006, 0.006-0.009 |
| Seismic Vibration Monitoring | Minimum accuracy of Seismic velocity measurement | 3%, 5% |
| Seismic Vibration Monitoring | Minimum linear frequency response Geophone | 2.0 |
| Seismic Vibration Monitoring | Maximum linear freqency response of Geophone | 250.0 |
| Sound Overpressure Monitoring | Maximum Linear sound overpressure monitored (dB) | 144-148 |
| Sound Overpressure Monitoring | Maximum Linear response of microphone | 250.0 |
| Sound Overpressure Monitoring | Minimum linear frequency response microphone | 2.0 |
| Sound Overpressure Monitoring | Minimum Linear sound overpressure monitored (dB) | 82-88 |
| Waveform recording & data collection | Sample Rate per channel(samples/sec) | 4096 |
| Waveform recording & data collection | Maximum Seismic trigger range(mm/sec) | 250-255 |
| Waveform recording & data collection | Fixed Record time option available(Auto record off) | Yes |
| Waveform recording & data collection | Storage Capacity (Fullwave form events)at selected sample rate | 3000-4000, 4000-5000, 30000-40000 |
| Waveform recording & data collection | Waveform recording modes | Fullwave form, Combined, Manual |
| Waveform recording & data collection | Maximum Linear sound trigger range(dB) | 140-144, 144-148 |
| Waveform recording & data collection | Minimum Linear sound trigger range(dB) | 90-95, 95-100 |
| Waveform recording & data collection | Minimum Seismic trigger range(mm/sec) | 0.05-0.10, 0.10-0.15 |
| Histogram/Bar Graph Recording | Bar code recording summary interval(Minutes) | 5, 30 |
| Histogram/Bar Graph Recording | Display facility feature available | Peak particle velocity, Frequency, Displacement, Air over pressure level, Acceleration, Peak Vector Sum, RMS/Peak Velocity, Acceleration & Displacement |
| Histogram/Bar Graph Recording | Bar recording interval options | 1.0, 30.0 |
| Generic Parameters | Water Proof(Submerged 20+ cm in water logged mines) | Yes |
| Generic Parameters | PC Interface | USB |
| Generic Parameters | Maximum operating temperature of device | 50.0, 55.0 |
| Generic Parameters | Handheld & portable data monitor | Yes |
| Generic Parameters | Virtual Keypad available | Yes |
| Generic Parameters | Thumb drive available for copying data field | Yes |
| Generic Parameters | Facility for manual entry of GPS Way points | Yes |
| Generic Parameters | Touch screen display available | No, Yes |
| Generic Parameters | Minimum operating temperature of device | -20-(-)10, (-)10-(-5) |
| Generic Parameters | Maximum Battery backup duration (Days) | 8-10 |
| Generic Parameters | Modular Software for Vibration Data Analysis Provided | Yes |
| Generic Parameters | Facility of selection & deletion of false event | Yes |
| Generic Parameters | Facility for remote commuications | Yes |
| Generic Parameters | Number of function keys on Integrated keypad | 8-10, 10-12 |
| Generic Parameters | Integrated Keypad | Yes |
| Accessories | Carrying Case | Yes |
| Accessories | PC/Laptopn Connection Cable | Yes |
| Accessories | External data printer | Yes, No |