Progress
A tender has been published for Nuclear Power Corporation Of India Limited Gamma ionization chamber Detectors Model G12_NPCIL specification_PC_E_433_for High Range Area Radia in SURAT, GUJARAT. Quantity: 969 by. Submission Deadline: 15-10-2026 11: 00: 00. Check eligibility and apply.
Quantity
969
Category
Gamma ionization chamber Detectors Model G12_NPCIL specification_PC_E_433_for High Range Area Radiation Monitors_Make ECIL
Bid Type
Single Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
7 Days
EMD Required
Yes
MII Purchase Preference
No
MSE Purchase Preference
No
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Advisory Bank
State Bank of India
Payment Timelines
Payments shall be made to the Seller within 10 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
600
Delivery Locations
1
Delivery Cities
Tapi
Delivery Pincodes
394651
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Trivedi Jayshreeben Ranchhodlal | 394651,KAPS PLANT SITE PO ANUMALA,DIS - TAPI,SURAT,GUJARAT-394651 | Tapi | Gujarat | 394651 | 5 | 600 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
OTHER
BOQ
BOQ
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
15-Oct-2026, 5:30 am
Opening Date
16-Oct-2026, 5:30 am
Gamma ionization chamber Detectors Model G12_NPCIL specification_PC_E_433_for High Range Area Radiation Monitors_Make ECIL
As per BOQ
Ionization Chamber Detector_G12A_. NPCIL specification_PC_E_434_for Wide Range Area Radiation Monitors. Make ECIL
As per BOQ
Detectors. NPCIL specification_PC_E_446_for Process Water Discharge Activity Monitors. Make ECIL
As per BOQ
Pulse amplifier.NPCIL specification_PC_E_446_for Process Water Discharge Activity Monitors. Make ECIL
As per BOQ
Signal Processing Unit_SPU_module. NPCIL specification_PC_E_439_ for Stack Gamma Monitors. Make ECIL
As per BOQ
Analog to Digital converter_ADC_module. NPCIL specification_PC_E_437_for Stack Iodine Monitors. Make ECIL
As per BOQ
Display module. NPCIL specification_PC_E_437_for Stack Iodine Monitors. Make ECIL
As per BOQ
Control Processing Unit_CPU. NPCIL specification_PC_E_438_for Stack Particulate Activity Monitors. Make ECIL
As per BOQ
Analog to Digital converter_ADC_module. NPCIL specification PC_E_438 for Stack Particulate Activity Monitors. Make ECIL
As per BOQ
High Voltage_HV_ Module. NPCIL specification_PC_E_568_for Tritium In Water Monitoring_TIWM_system.Make ECIL
As per BOQ
Detectors. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL
As per BOQ
MultiChannel Analyser spare set incl TypeA for FPNG Iodine Nal Detector Data Acquisition Card for InputOutput Signal Processing Unit.Rotameter 0_100LPM with 1_2 inch end conection.spec PCE796.MakeECIL
As per BOQ
Signal processing printed circuit board_PCB. NPCIL specification PC_E_442 for PORTAL Monitor. Make_ECIL
As per BOQ
Detectors. NPCIL specification PC_E_695 for Area Particulate Monitor. Make ECIL
As per BOQ
Preamplifier. NPCIL specification PC_E_573 for Ion chamber system. Make ECIL
As per BOQ
Battery Backup Control Unit. NPCIL specification PC_E_435 for Environment radiation Monitoring system_ERM. Make ECIL
As per BOQ
Detector_NaI detector coupled with Photomultiplier tube_Make_Scinoix_2_2inch_integrated with Photo multiplier tube_51BR51_2M and Voltage divider assembly_VD14_E1.spec PC_E_435. Make ECIL
As per BOQ
HighVoltage Power Supply HVPS_Module Range 0_1250 V DC_1mA_adjustable helipot. Accuracy 2.5 v of set value.Ripple Less than 50mVpp. Output setting_10 turn helipot.spec PC_E_435.Make ECIL.
As per BOQ
Low Voltage Supply Module. NPCIL specification PC_E_435 for Environment Radiation Monitor. Make ECIL
As per BOQ
Preamplifier.NPCIL specification PC_E_435 for Environment Radiation Monitor. Make ECIL
As per BOQ
Linear Pulse Amplifier Module and Discriminator Module. NPCIL specification PC_E_435 for Environment Radiation Monitor. Make ECIL
As per BOQ
Integrator Module. NPCIL specification_PC_E_435_for Environment Radiation Monitor. Make ECIL
As per BOQ
Solar panel along with mounting stand and accessories. NPCIL specification PC_E_435 for Environment Radiation Monitor. Make ECIL
As per BOQ
Pancake Detector for portal monitoring system. NPCIL specification PC-E-442 for Portal Monitor. Make ECIL
As per BOQ
High Voltage Power Supply_HVPS_Module. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL
As per BOQ
Low Voltage Supply Module. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL
As per BOQ
Microcontroller IC 64 pin NXP_P80C552EFA. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL
As per BOQ
Industrial Embedded PC along with the Portal Monitor Application Software. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL
As per BOQ
Isolation transformer. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL
As per BOQ
Photo Electric Sensor RX TX along with the bias resistors and mounting PCB. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL
As per BOQ
Low Voltage Supply Module. Input 220VDC_Output 5VDC at 2A_15VDC at 1A_15VDC at 0.5A_24VDC_0.5A_NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make ECIL
As per BOQ
High Voltage Power Supply_HVPS_Module. Input 15VDC_24VDC_Output 0_1250VDC.Set at 900VDC for HFCM. NPCIL spec PC_E_440 for Hand and Foot contamination monitor. Make ECIL
As per BOQ
Control Processing Unit Printed Circuit board_CPU PCB. NPCIL specification PC_E_440 for Hand and Foot_contamination monitor. Make ECIL
As per BOQ
Back panel PCB. NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make ECIL
As per BOQ
Backplane _ICs and inductor. NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make ECIL
As per BOQ
Hand PCB. NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make ECIL
As per BOQ
Foot PCB. NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make_ECIL
As per BOQ
Low Voltage Supply Module. Input 220V DC_Output 5V_2A_15V_1A_negative 15V_0.5A and 24V_0.5A. NPCIL specification PC_E_441 for Frisker contamination monitor. Make_ECIL
As per BOQ
High Voltage Power Supply_HVPS_Module. Input 24VDC Output_0 to 1250 VDC output. NPCIL specification_PC_E_441 for Frisker contamination monitor. Make ECIL
As per BOQ
Amplifier Module. NPCIL specification_PC_E_441 for Frisker contamination monitor. Make ECIL
As per BOQ
Signal processing Unit. NPCIL specification PC_E_441 for Frisker contamination monitor. Make ECIL
As per BOQ
Mother Board PCB. NPCIL specification PC_E_441 for Frisker contamination monitor. Make ECIL
As per BOQ
Low Voltage Power Supply_LVPS_Module. Input 220V DC_Output_12V DC_1A neg12V DC_0.5A_24V DC_1A_NPCIL specification PC_E_433 for High Range area radiation monitor. Make ECIL
As per BOQ
High Voltage Power Supply HVPS Module.Input 12V_neg12V_24V DC.Output 0_1250V variable by Helipot with locking dial. Max current 1mA.NPCIL spec PC_E_433 for High Range area radiation monitor.Make ECIL
As per BOQ
Pre Amplifier. NPCIL specification_PC_E_433 for High Range area radiation monitor. Make ECIL
As per BOQ
Signal Processing Unit. NPCIL specification PC_E_433 for High Range area radiation monitor. Make ECIL
As per BOQ
Detectors Low range LND 7121. NPCIL specification PC_E_432 for Low range area radiation monitors. Make ECIL
As per BOQ
Detectors High range LND 723. NPCIL specification PC_E_432 for Low range area radiation monitors. Make ECIL
As per BOQ
Low Voltage Power Supply_LVPS_Module. Input 220V DC_ Output 12V_negative 12V and 24V DC_NPCIL specification PC_E_432 for Low range area radiation monitors. Make ECIL
As per BOQ
HighVoltage Power Supply HVPSModule.Input 12V_neg12V_24VDC.Output 0_1250VDC variable by HELIPOT With locking dial max current1mA_NPCILspec PC_E_432 for Low range area radiation monitors.MakeECIL
As per BOQ
Signal Processing Unit. NPCIL specification PC_E_432 for Low range area radiation monitors. Make ECIL
As per BOQ
L.V Power Supply 15V DC_1A_15V DC_1A_24V DC_0.5A_5VDC_2A. NPCIL specification PC_E_436 for Ventilation Duct Radiation Monitors. Make ECIL
As per BOQ
H.V Power Supply_0 to 1250V variable by Helipot with locking dial. Max current 1mA.NPCIL specification_PC_E_436 for Ventilation Duct Radiation Monitors. Make ECIL
As per BOQ
Signal and Alarm Module. NPCIL specification PC_E_436 for Ventilation Duct Radiation Monitors. Make ECIL
As per BOQ
Analog Indicating Meter, NPCIL specification PC_E_436 for Ventilation Duct Radiation Monitors. Make ECIL
As per BOQ
Low Voltage Power Supply 15V DC_1A_negative 15V DC_1A_24V DC_0.5A_5VDC_2A_NPCIL specification_PC_E_434 for Wide Range Area Radiation Monitors. Make ECIL
As per BOQ
High Voltage Power Supply_0 to 1250V variable by Helipot with locking dial. Max current 1mA. NPCIL specification_PC_E_434 for Wide Range Area Radiation Monitors. Make ECIL
As per BOQ
Signal Processing Unit. NPCIL specification PC_E_434 for Wide Range Area Radiation Monitors. Make ECIL
As per BOQ
Analog Indicating Meter. NPCIL specification PC_E_434 for Wide Range Area Radiation Monitors. Make ECIL
As per BOQ
Vacuum pump. NPCIL specification PC_E_695 and PC_E_734 for Area Iodine_Particulate Radiation Monitors. Make ECIL
As per BOQ
Pump maintenance kit set. NPCIL specification PC_E_695 for Area Iodine_Particulate Radiation Monitors. Make ECIL
As per BOQ
High Voltage Power Supply_HVPS_Module. NPCIL specification PC_E_446 for Process Water Discharge Activity Monitors. Make ECIL
As per BOQ
Low Voltage Supply Module. NPCIL specification PC_E_446 for Process Water Discharge Activity Monitors. Make_ECIL
As per BOQ
Temperature protecting module. NPCIL specification PC_E_446 for Process Water Discharge Activity Monitors. Make ECIL
As per BOQ
Detector. NPCIL specification PC_E_439 for Stack Gamma Monitor. Make ECIL
As per BOQ
Detector. NPCIL specification PC_E_437 for Stack Iodine Monitor. Make ECIL
As per BOQ
Detector. NPCIL specification_PC_E_438 for Stack Particulate Monitor. Make ECIL
As per BOQ
High Voltage Power Supply_HVPS_Module for Ion chamber. Make ECIL
As per BOQ
Control PCB for Flasher hooter. Make ECIL
As per BOQ
Power supply PCB for Flasher hooter. Make ECIL
As per BOQ
Speaker assembly for Flasher hooter. Make ECIL
As per BOQ
Red LED light assembly for Flasher hooter. Make ECIL
As per BOQ
Rotameter. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL
As per BOQ
Differential Pressure Indicating Alarm. NPCIL specification_PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL
As per BOQ
AMPLIFIER Module. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL
As per BOQ
Count rate meter Module. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL
As per BOQ
Low Voltage POWER SUPPLY Module. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System Make ECIL.
As per BOQ
ANALYSER Module. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL
As per BOQ
Printed circuit board_PCBs consisting Pre_Amplifier_SCM 1 and SCM 2 and Detector_NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make_ECIL
As per BOQ
IR Detector. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL
As per BOQ
Filter Wheel. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL
As per BOQ
Filter Wheel Position Sensors. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL
As per BOQ
Brushless DC Motor. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL
As per BOQ
Convex Lens. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL
As per BOQ
Circular Connectors_J1_ J2 and J3 Connectors. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL
As per BOQ
Exhaust Fan. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL
As per BOQ
Low Voltage Supply Module. NPCIL specification PC_E_567 for Tritium in Air Monitoring System. Make ECIL
As per BOQ
High Voltage Power Supply_HVPS_Module. NPCIL specification PC_E_567 for Tritium in Air Monitoring System. Make ECIL
As per BOQ
Flow meter. NPCIL specification PC_E_567 for Tritium in Air Monitoring System. Make ECIL
As per BOQ
High Voltage Power Supply_HVPS Module. NPCIL specification PC_E_819 for Intelligent Accessible Area Radiation Monitor. Make ECIL
As per BOQ
Low Voltage Supply Module. NPCIL specification PC_E_819 for Intelligent Accessible Area Radiation Monitor. Make ECIL
As per BOQ
Signal processing module. NPCIL specification PC_E_819 for Intelligent Accessible Area Radiation Monitor. Make ECIL
As per BOQ
Preamplifier. NPCIL specification PC_E_819 for Intelligent Accessible Area Radiation Monitor. Make ECIL
As per BOQ
High Voltage Power Supply_HVPS Module. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL
As per BOQ
Low Voltage Supply Module. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL
As per BOQ
Signal processing module. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL
As per BOQ
Preamplifier. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL
As per BOQ
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Gamma ionization chamber Detectors Model G12_NPCIL specification_PC_E_433_for High Range Area Radiation Monitors_Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 2 | Ionization Chamber Detector_G12A_. NPCIL specification_PC_E_434_for Wide Range Area Radiation Monitors. Make ECIL | As per BOQ | 6 | pieces | con2.kaps | 600 | |
| 3 | Detectors. NPCIL specification_PC_E_446_for Process Water Discharge Activity Monitors. Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 4 | Pulse amplifier.NPCIL specification_PC_E_446_for Process Water Discharge Activity Monitors. Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 5 | Signal Processing Unit_SPU_module. NPCIL specification_PC_E_439_ for Stack Gamma Monitors. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 6 | Analog to Digital converter_ADC_module. NPCIL specification_PC_E_437_for Stack Iodine Monitors. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 7 | Display module. NPCIL specification_PC_E_437_for Stack Iodine Monitors. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 8 | Control Processing Unit_CPU. NPCIL specification_PC_E_438_for Stack Particulate Activity Monitors. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 9 | Analog to Digital converter_ADC_module. NPCIL specification PC_E_438 for Stack Particulate Activity Monitors. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 10 | High Voltage_HV_ Module. NPCIL specification_PC_E_568_for Tritium In Water Monitoring_TIWM_system.Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 11 | Detectors. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 12 | MultiChannel Analyser spare set incl TypeA for FPNG Iodine Nal Detector Data Acquisition Card for InputOutput Signal Processing Unit.Rotameter 0_100LPM with 1_2 inch end conection.spec PCE796.MakeECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 13 | Signal processing printed circuit board_PCB. NPCIL specification PC_E_442 for PORTAL Monitor. Make_ECIL | As per BOQ | 20 | pieces | con2.kaps | 600 | |
| 14 | Detectors. NPCIL specification PC_E_695 for Area Particulate Monitor. Make ECIL | As per BOQ | 3 | pieces | con2.kaps | 600 | |
| 15 | Preamplifier. NPCIL specification PC_E_573 for Ion chamber system. Make ECIL | As per BOQ | 3 | pieces | con2.kaps | 600 | |
| 16 | Battery Backup Control Unit. NPCIL specification PC_E_435 for Environment radiation Monitoring system_ERM. Make ECIL | As per BOQ | 6 | pieces | con2.kaps | 600 | |
| 17 | Detector_NaI detector coupled with Photomultiplier tube_Make_Scinoix_2_2inch_integrated with Photo multiplier tube_51BR51_2M and Voltage divider assembly_VD14_E1.spec PC_E_435. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 18 | HighVoltage Power Supply HVPS_Module Range 0_1250 V DC_1mA_adjustable helipot. Accuracy 2.5 v of set value.Ripple Less than 50mVpp. Output setting_10 turn helipot.spec PC_E_435.Make ECIL. | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 19 | Low Voltage Supply Module. NPCIL specification PC_E_435 for Environment Radiation Monitor. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 20 | Preamplifier.NPCIL specification PC_E_435 for Environment Radiation Monitor. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 21 | Linear Pulse Amplifier Module and Discriminator Module. NPCIL specification PC_E_435 for Environment Radiation Monitor. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 22 | Integrator Module. NPCIL specification_PC_E_435_for Environment Radiation Monitor. Make ECIL | As per BOQ | 3 | pieces | con2.kaps | 600 | |
| 23 | Solar panel along with mounting stand and accessories. NPCIL specification PC_E_435 for Environment Radiation Monitor. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 24 | Pancake Detector for portal monitoring system. NPCIL specification PC-E-442 for Portal Monitor. Make ECIL | As per BOQ | 500 | pieces | con2.kaps | 600 | |
| 25 | High Voltage Power Supply_HVPS_Module. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 26 | Low Voltage Supply Module. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 27 | Microcontroller IC 64 pin NXP_P80C552EFA. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL | As per BOQ | 15 | pieces | con2.kaps | 600 | |
| 28 | Industrial Embedded PC along with the Portal Monitor Application Software. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 29 | Isolation transformer. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 30 | Photo Electric Sensor RX TX along with the bias resistors and mounting PCB. NPCIL specification PC_E_442 for Portal Monitor. Make ECIL | As per BOQ | 6 | pieces | con2.kaps | 600 | |
| 31 | Low Voltage Supply Module. Input 220VDC_Output 5VDC at 2A_15VDC at 1A_15VDC at 0.5A_24VDC_0.5A_NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make ECIL | As per BOQ | 6 | pieces | con2.kaps | 600 | |
| 32 | High Voltage Power Supply_HVPS_Module. Input 15VDC_24VDC_Output 0_1250VDC.Set at 900VDC for HFCM. NPCIL spec PC_E_440 for Hand and Foot contamination monitor. Make ECIL | As per BOQ | 6 | pieces | con2.kaps | 600 | |
| 33 | Control Processing Unit Printed Circuit board_CPU PCB. NPCIL specification PC_E_440 for Hand and Foot_contamination monitor. Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 34 | Back panel PCB. NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make ECIL | As per BOQ | 8 | pieces | con2.kaps | 600 | |
| 35 | Backplane _ICs and inductor. NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make ECIL | As per BOQ | 10 | pieces | con2.kaps | 600 | |
| 36 | Hand PCB. NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 37 | Foot PCB. NPCIL specification PC_E_440 for Hand and Foot contamination monitor. Make_ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 38 | Low Voltage Supply Module. Input 220V DC_Output 5V_2A_15V_1A_negative 15V_0.5A and 24V_0.5A. NPCIL specification PC_E_441 for Frisker contamination monitor. Make_ECIL | As per BOQ | 10 | pieces | con2.kaps | 600 | |
| 39 | High Voltage Power Supply_HVPS_Module. Input 24VDC Output_0 to 1250 VDC output. NPCIL specification_PC_E_441 for Frisker contamination monitor. Make ECIL | As per BOQ | 8 | pieces | con2.kaps | 600 | |
| 40 | Amplifier Module. NPCIL specification_PC_E_441 for Frisker contamination monitor. Make ECIL | As per BOQ | 8 | pieces | con2.kaps | 600 | |
| 41 | Signal processing Unit. NPCIL specification PC_E_441 for Frisker contamination monitor. Make ECIL | As per BOQ | 10 | pieces | con2.kaps | 600 | |
| 42 | Mother Board PCB. NPCIL specification PC_E_441 for Frisker contamination monitor. Make ECIL | As per BOQ | 10 | pieces | con2.kaps | 600 | |
| 43 | Low Voltage Power Supply_LVPS_Module. Input 220V DC_Output_12V DC_1A neg12V DC_0.5A_24V DC_1A_NPCIL specification PC_E_433 for High Range area radiation monitor. Make ECIL | As per BOQ | 6 | pieces | con2.kaps | 600 | |
| 44 | High Voltage Power Supply HVPS Module.Input 12V_neg12V_24V DC.Output 0_1250V variable by Helipot with locking dial. Max current 1mA.NPCIL spec PC_E_433 for High Range area radiation monitor.Make ECIL | As per BOQ | 6 | pieces | con2.kaps | 600 | |
| 45 | Pre Amplifier. NPCIL specification_PC_E_433 for High Range area radiation monitor. Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 46 | Signal Processing Unit. NPCIL specification PC_E_433 for High Range area radiation monitor. Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 47 | Detectors Low range LND 7121. NPCIL specification PC_E_432 for Low range area radiation monitors. Make ECIL | As per BOQ | 25 | pieces | con2.kaps | 600 | |
| 48 | Detectors High range LND 723. NPCIL specification PC_E_432 for Low range area radiation monitors. Make ECIL | As per BOQ | 40 | pieces | con2.kaps | 600 | |
| 49 | Low Voltage Power Supply_LVPS_Module. Input 220V DC_ Output 12V_negative 12V and 24V DC_NPCIL specification PC_E_432 for Low range area radiation monitors. Make ECIL | As per BOQ | 10 | pieces | con2.kaps | 600 | |
| 50 | HighVoltage Power Supply HVPSModule.Input 12V_neg12V_24VDC.Output 0_1250VDC variable by HELIPOT With locking dial max current1mA_NPCILspec PC_E_432 for Low range area radiation monitors.MakeECIL | As per BOQ | 10 | pieces | con2.kaps | 600 | |
| 51 | Signal Processing Unit. NPCIL specification PC_E_432 for Low range area radiation monitors. Make ECIL | As per BOQ | 12 | pieces | con2.kaps | 600 | |
| 52 | L.V Power Supply 15V DC_1A_15V DC_1A_24V DC_0.5A_5VDC_2A. NPCIL specification PC_E_436 for Ventilation Duct Radiation Monitors. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 53 | H.V Power Supply_0 to 1250V variable by Helipot with locking dial. Max current 1mA.NPCIL specification_PC_E_436 for Ventilation Duct Radiation Monitors. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 54 | Signal and Alarm Module. NPCIL specification PC_E_436 for Ventilation Duct Radiation Monitors. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 55 | Analog Indicating Meter, NPCIL specification PC_E_436 for Ventilation Duct Radiation Monitors. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 56 | Low Voltage Power Supply 15V DC_1A_negative 15V DC_1A_24V DC_0.5A_5VDC_2A_NPCIL specification_PC_E_434 for Wide Range Area Radiation Monitors. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 57 | High Voltage Power Supply_0 to 1250V variable by Helipot with locking dial. Max current 1mA. NPCIL specification_PC_E_434 for Wide Range Area Radiation Monitors. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 58 | Signal Processing Unit. NPCIL specification PC_E_434 for Wide Range Area Radiation Monitors. Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 59 | Analog Indicating Meter. NPCIL specification PC_E_434 for Wide Range Area Radiation Monitors. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 60 | Vacuum pump. NPCIL specification PC_E_695 and PC_E_734 for Area Iodine_Particulate Radiation Monitors. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 61 | Pump maintenance kit set. NPCIL specification PC_E_695 for Area Iodine_Particulate Radiation Monitors. Make ECIL | As per BOQ | 3 | pieces | con2.kaps | 600 | |
| 62 | High Voltage Power Supply_HVPS_Module. NPCIL specification PC_E_446 for Process Water Discharge Activity Monitors. Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 63 | Low Voltage Supply Module. NPCIL specification PC_E_446 for Process Water Discharge Activity Monitors. Make_ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 64 | Temperature protecting module. NPCIL specification PC_E_446 for Process Water Discharge Activity Monitors. Make ECIL | As per BOQ | 5 | pieces | con2.kaps | 600 | |
| 65 | Detector. NPCIL specification PC_E_439 for Stack Gamma Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 66 | Detector. NPCIL specification PC_E_437 for Stack Iodine Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 67 | Detector. NPCIL specification_PC_E_438 for Stack Particulate Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 68 | High Voltage Power Supply_HVPS_Module for Ion chamber. Make ECIL | As per BOQ | 3 | pieces | con2.kaps | 600 | |
| 69 | Control PCB for Flasher hooter. Make ECIL | As per BOQ | 20 | pieces | con2.kaps | 600 | |
| 70 | Power supply PCB for Flasher hooter. Make ECIL | As per BOQ | 20 | pieces | con2.kaps | 600 | |
| 71 | Speaker assembly for Flasher hooter. Make ECIL | As per BOQ | 20 | pieces | con2.kaps | 600 | |
| 72 | Red LED light assembly for Flasher hooter. Make ECIL | As per BOQ | 20 | pieces | con2.kaps | 600 | |
| 73 | Rotameter. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL | As per BOQ | 6 | pieces | con2.kaps | 600 | |
| 74 | Differential Pressure Indicating Alarm. NPCIL specification_PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL | As per BOQ | 2 | pieces | con2.kaps | 600 | |
| 75 | AMPLIFIER Module. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 76 | Count rate meter Module. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 77 | Low Voltage POWER SUPPLY Module. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System Make ECIL. | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 78 | ANALYSER Module. NPCIL specification PC_E_568 for Tritium In Water Monitoring_TIWM_System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 79 | Printed circuit board_PCBs consisting Pre_Amplifier_SCM 1 and SCM 2 and Detector_NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make_ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 80 | IR Detector. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 81 | Filter Wheel. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 82 | Filter Wheel Position Sensors. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 83 | Brushless DC Motor. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 84 | Convex Lens. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 85 | Circular Connectors_J1_ J2 and J3 Connectors. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 86 | Exhaust Fan. NPCIL specification PC_E_566 for Vapour Based Online Heavy Water Loss Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 87 | Low Voltage Supply Module. NPCIL specification PC_E_567 for Tritium in Air Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 88 | High Voltage Power Supply_HVPS_Module. NPCIL specification PC_E_567 for Tritium in Air Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 89 | Flow meter. NPCIL specification PC_E_567 for Tritium in Air Monitoring System. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 90 | High Voltage Power Supply_HVPS Module. NPCIL specification PC_E_819 for Intelligent Accessible Area Radiation Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 91 | Low Voltage Supply Module. NPCIL specification PC_E_819 for Intelligent Accessible Area Radiation Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 92 | Signal processing module. NPCIL specification PC_E_819 for Intelligent Accessible Area Radiation Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 93 | Preamplifier. NPCIL specification PC_E_819 for Intelligent Accessible Area Radiation Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 94 | High Voltage Power Supply_HVPS Module. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 95 | Low Voltage Supply Module. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 96 | Signal processing module. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 | |
| 97 | Preamplifier. NPCIL specification PC_E_820 for Intelligent High Range Area Radiation Monitor. Make ECIL | As per BOQ | 1 | pieces | con2.kaps | 600 |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer