Nitrogen, Compressed Gas and Liquid conforming to IS 1747
Indian Army
SENAPATI, MANIPUR
Bid Publish Date
27-Jan-2026, 12:46 pm
Bid End Date
17-Feb-2026, 1:00 pm
EMD
₹1,50,000
Value
₹75,00,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
N/a has released a public tender for Gas Chromatography Mass Spectrometry (GC - MS) (Q3) in SOUTH ANDAMAN, ANDAMAN & NICOBAR. Quantity: 1. Submission Deadline: 17-02-2026 13: 00: 00. Download documents and apply online.
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Army
SENAPATI, MANIPUR
Health Services
AIZAWL, MIZORAM
Metro Railway Kolkata
KOLKATA, WEST BENGAL
Board Of Radiation And Isotope Technology
THANE, MAHARASHTRA
Indian Air Force
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Detectors inclusive in the scope of supply | Flame Ionization Detector (FID) |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FID in the System - inclusive in the scope of Supply | 1 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of TCD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of ECD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of NPD/FTD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FPD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PID in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PFPD in the System - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Inlets GC can Simultaneously Support | 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Detectors (Ports) GC can Simultaneously Support | 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Capillary Columns provided in GC - inclusive in the scope of Supply | 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Type of Capillary Column | Non-Polar |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" | 30.0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Internal Diameter (Hint:-Select '0' if Not Applicable)" | 0.25 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Film Thickness (Hint:-Select '0' if Not Applicable)" | 0.25 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | GC Packed Column Length | 0.0 |
| PERFORMANCE | GC Detector Minimum Detection Level (MDL) | < 1.4 pg C/s for FID |
| PERFORMANCE | GC Detector Linear Dynamic Range (± 10%) | >= 10e7 for FID |
| PERFORMANCE | GC Detector Data acquisition rate | 50 Hz or more |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Maximum Operating Temperature (GC Oven) | upto 450 deg. C (2) Or higher |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Oven cool down time from Max operating temperature to 50 Deg c | 3.5, 4 Or lower |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Number of Oven Ramps / Plateaus for Temperature programming | 20/21 or more |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Temperature set point resolution (±) | 0.1 |
| PNEUMATIC CONTROL | "Type of Inlet Pneumatics (Select applicable parameters only)" | Electronic Pneumatic Control (EPC), Programmed Pneumatic Control (PPC), Advanced Flow Controller (AFC), Advanced Pressure Controller (APC) |
| PNEUMATIC CONTROL | Number of Injection Ports | 2 |
| PNEUMATIC CONTROL | Maximum Injection Port heating Temperature | upto 450 deg. C (2) Or higher |
| PNEUMATIC CONTROL | Pressure Range | upto 120 psi (2) Or higher |
| PNEUMATIC CONTROL | Pressure set point Resolution (±)(psi) | 0.001 Or lower |
| PNEUMATIC CONTROL | Type of Sample Injection Port | split / Splitless |
| PNEUMATIC CONTROL | Split Ratio | 7500:1 |
| PNEUMATIC CONTROL | Modes of Operation | Constant flow, Constant Pressure, Programmable Flow, Programmable Pressure, Large volume - 200 microliters or more for capillary column |
| AUTO INJECTOR / AUTO SAMPLER | Compatible Liquid Auto Sampler - inclusive in the scope of supply | Yes |
| AUTO INJECTOR / AUTO SAMPLER | Capacity of the Liquid Auto Sampler (Number of Vials) | 100, 150 Or higher |
| AUTO INJECTOR / AUTO SAMPLER | Number of Injection Ports in the Liquid Auto Sampler | 1 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Channels in the Liquid Auto Sampler | 2 |
| AUTO INJECTOR / AUTO SAMPLER | Operating Voltage of the Liquid Auto Sampler | 230 V ± 10% |
| AUTO INJECTOR / AUTO SAMPLER | Liquid Auto Sampler Features | Fully automated Liquid Auto Sampler |
| HEAD SPACE SAMPLER | Compatible Head Space Sampler- inclusive in the scope of supply | Yes |
| HEAD SPACE SAMPLER | Capacity of the Head Space Sampler Carousel (number of Vials) | 12 or better |
| HEAD SPACE SAMPLER | Head Space Sampler Temperature Range | Upto 200 deg. C or better |
| PYROLYZER SYSTEM | Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply | No |
| MASS SPECTROPHOTOMETER (MS) SYSTEM | Ionization modes | Electron Ionization (EI) |
| MASS SPECTROPHOTOMETER (MS) SYSTEM | Detector Type | Electron Multiplier |
| MASS SPECTROPHOTOMETER (MS) SYSTEM | Operating modes | Both Full Scan & SIM Modes |
| PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS) SYSTEM | Sensitivity (S/N Ratio) in full scan | 1500:1 with 1 pg/microliter OFN |
| PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS) SYSTEM | Ionization Energy / Electron Energy | upto 200 eV |
| SALIENT FEATURES OF GC-MS | "Salient Featutes of GC-MS (Select applicable features Only)" | Automatic leak testing/detection of Pneumatics |
| LIBERARIES | Libraries for GC-MS | NIST Library for MS - Licensed version - 2017 or latest |
| SOFTWARE | "Software Features (Select Applicable Features only)" | Compatible with Windows 7 or higher version operating system |
| DESKTOP WORKSTATION | Desktop workstation Suitable to GC-MS - inclusive in the scope of supply | Yes |
| DESKTOP WORKSTATION | Graphics Card Memory Size | 0.0 |
| ONLINE UPS | UPS Provided in the Scope of Supply | Yes |
| ONLINE UPS | Rating of online UPS(KVA) | 10 KVA |
| ONLINE UPS | Backup time of online UPS | 60.0 |
| GENERIC | Power Supply | 230 V ± 10% |
| GENERIC | Built-in Display | Yes |
| GENERIC | Connectivity interface | RS 232 |
| GENERIC | Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously | No |
| GENERIC | Back Flash - inclusive in the scope of supply | NA |
| ACESSORIES | Gas Supply inclusive in the scope of supply | Nitrogen, Hydrogen, Helium, Zero Air |
| ACESSORIES | Capacity of Gas cylinder | 47 liters water capacity for Nitrogen, Hydrogen, Argon,Helium & Zero Air |
| ACESSORIES | Number of Cyliners of each type supplied - inclusive in the scope of supply | 1 |
| ACESSORIES | Gas cylinders certified by PESO | Yes |
| ACESSORIES | Regulator - inclusive in the scope of supply | Dual Stage Regulator |
| ACESSORIES | "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" | Gas purification panel for all Gases with moisture trap |
| ENVIRONMENTAL | Maximum Operating Temperature | 40.0 - 65.0 Or higher |
| ENVIRONMENTAL | Operating Humidity (RH) (%) at 40 degree C | 95.0 - 95.0 Or higher |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Warranty on equipment | 1.0 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of days onsite training provided | 3.0 |
| CERTIFICATION / TEST REPORT | "Availability of UL/CE Certificate as per EN 61010- 1:2010 Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" | No |
| CERTIFICATION / TEST REPORT | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | No |
| CERTIFICATION / TEST REPORT | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | No |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Institutes Of Science Education And Research (iiser)
WEST BENGAL POLLUTION CONTROL BOARD
📍 24 PARAGANAS NORTH, WEST BENGAL
All India Institute of Medical Science-New Delhi
📍 SOUTH, DELHI
All India Institute of Medical Science-New Delhi
📍 SOUTH, DELHI
Directorate Of Purchase And Stores
📍 JAIPUR, RAJASTHAN
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS