1.5 T MRI Machine
Dr Bhubanesar Borooah Cancer Institute Bbci
KAMRUP, ASSAM
Progress
Quantity
1
Bid Type
Two Packet Bid
A tender has been published for Directorate Of Medical Education Magnetic Resonance Imaging (MRI) Machine (Q2) in KAMRUP, ASSAM. Quantity: 1 by. Submission Deadline: 17-06-2026 17: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Magnetic Resonance Imaging (MRI) Machine (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Dr Bhubanesar Borooah Cancer Institute Bbci
KAMRUP, ASSAM
Chittaranjan Locomotive Works
BARDHAMAN, WEST BENGAL
North Eastern Railway
BAREILLY, UTTAR PRADESH
N/a
Government Medical College And Hospital
CHANDIGARH, CHANDIGARH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Generic | Helium refill time should not be less than 2 years | Yes, |
| Magnet | Magnet Strength | 1.5 T |
| Magnet | Homogeneity of magnet | 0.2 to 1.4 ppm at 40 cm DSV[diameter spherical volume] |
| Gantry | Bore diameter (cm) | >= 60 cm |
| Shim | Type of shimming | Auto/Active +Passive |
| PATIENT TABLE | Patient table movement control | Motorized ( Longitudinal and vertical) |
| PATIENT TABLE | Minimum patient table load capacity | 130 kg |
| ACOUSTIC NOISE | Maximum sound pressure level | < 120 dB(A) |
| ACOUSTIC NOISE | Acoustic noise reduction | < 85 dB(A) with hardware/software solutions |
| GRADIENT SYSTEM | Actively shielded Gradient system | Yes |
| GRADIENT SYSTEM | Actual Peak Amplitude with each axis independently ( mT/m) [millitesla per meter] | ≥ 30 (1.5 T) |
| GRADIENT SYSTEM | Type of Coils [Hint: Buyer may specify the details of coil in the Bid Document, as required] | Head coil /Head and Neck Coil , Spine coil, Body / Torso Coils / Cardiac Coils, Extremity Coils + Breast Coil |
| GRADIENT SYSTEM | Actual Standard slew rate , with each axis independently (T/m/sec) | ≥100(1.5 T) |
| RF SYSTEM | RF Receiver Channels (Minimum) | 16 (1.5 T) |
| RF SYSTEM | Minimum RF transmitter and receiver power output | 10-30 kW (1.5T) |
| RF SYSTEM | Receiver Bandwidth per channel (KHz) | 500 - 1000 kHz |
| Software | Application Software [Hint: Buyer may specify the details of each application software in the Bid Document, as required] | Application software – CSF flow and T1, T2and T2*, Dynamic liver sequences, Fast dynamic 3D breast imaging, Cartilage Imaging including quantitative T1, T2 and T2* mapping ( relaxometry), The system should have facility to do headto toe imaging without shifting the patient, Flow quantification in vessels/hepatobiliary system, Flow Artifacts reduction technique, Image addition, subtraction, division facility, Breath hold and free breathing acquisition, Dynamic breast sequences, 3D high resolution T2WI – possibility to format data in all sequences, Double Echo steady state like DESS /Proset or equivalent, MR angio: 2D / 3D TOF, 2D / 3D phasecontrast (with and without gating)magnetization transfer saturation, black angiography for cerebral,pulmonary, abdominal and peripheral vessels, MR cholangiography and Pancreatogram, MR ventriculography and cisternography , Myelography, Motion artifacts reduction for head and abdomen acquisition, Cardiac Imaging software- Myocardial tagging,myocardial perfusion, 4D flow MRI, T1, T2 and T2* mapping, myocardial fibrosis quantification, MR elastography, Neuro Perfusion imaging, Arterial spin labelling, myelin quantification, Brain atrophy quantification, Functional MRI |
| WORKSTATION | Medical Grade Monitor Required | Single Monitor |
| WORKSTATION | Data transfer | CD / DVD, PACS Compatibility, USB |
| WORKSTATION | IHE profiles supported | Yes |
| WORKSTATION | Workstation | Yes |
| Certification | Compliance to Drugs and Cosmetic Act 1940 and Medical Device Rules (MDR) 2017 as amended till date | Yes |
| Certification | Availability of valid Medical Device license for the product issued from the competent authority | Yes |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Years |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
17-Jun-2026, 5:00 pm
Opening Date
17-Jun-2026, 5:30 pm
Extended Deadline
15-Jun-2026, 5:00 pm
Opening Date
15-Jun-2026, 5:30 pm
Hll Lifecare Limited
📍 THIRUVANANTHAPURAM, KERALA
Hll Infra Tech Services Limited
Hll Lifecare Limited
📍 THRISSUR, KERALA
Dg Armed Forces Medical Service
N/a
📍 RANCHI, JHARKHAND
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS