TenderDekho Logo
Active GEM

Invitation to Bid - ICU Ventilators (V2) in CENTRAL DELHI, DELHI

Bid Publish Date

11-Aug-2026, 10:46 am

Bid End Date

24-Sep-2026, 1:00 pm

Progress

Issue11-Aug-2026, 10:46 am
AwardPending

Public procurement opportunity for N/a ICU Ventilators (V2) (Q2) in CENTRAL DELHI, DELHI. Quantity: 30 issued by. Submission Deadline: 24-09-2026 13: 00: 00. View full details and respond.

Tender Data

Bid Details

Quantity

30

Bid Type

Two Packet Bid

Bid Validity

180 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

RA Qualification Rule

H1-Highest Priced Bid Elimination

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

Yes

MII Purchase Preference

No

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

Yes

Startup Exemption/Relaxation

Yes

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

600

OEM Avg. Turnover

1350

Past Performance

50 %

Warranty Period

7 days

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

ICU Ventilators (V2) (Q2)

Advisory Bank

Bank Of Baroda

ePBG Percentage

5%

ePBG Duration (Months)

30

Pre-Bid & Qualification

Pre-Bid Date

20-08-2026 12:00:00

Pre-Bid Venue

Room No. 202, 2nd floor, Trauma Building, Department of Critical Care Medicine, Dr. Ram Manohar Lohia Hospital, New Delhi

Delivery Details

Max Delivery Days

90

Delivery Locations

1

Delivery Cities

New Delhi

Delivery Pincodes

110001

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Harikesh Meena110001,dr. ram manohar lohia hospital baba kharak singh marg new delhiNew DelhiDelhi1100013090-

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 6

GeM-Bidding-9725191.pdf

Main Document

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Authority & Contact

Organization

N/a

Office Name

Dr. Ram Manohar Lohia Hospital, New Delhi

Grievance Contact

[email protected]

Categories 1

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
PRODUCT INFORMATION Patient Type Adult & pediatric
PRODUCT INFORMATION Type of technology Turbine, Compressor
PRODUCT INFORMATION Tidal volume in ml (2 ml or less) to (1500 ml or more)
PRODUCT INFORMATION Respiration rate, breaths/min up to 80 or more
PRODUCT INFORMATION Trigger mechanism Both pressure and flow
PRODUCT INFORMATION Inspiratory flow rate, L/min upto 120 or more
PRODUCT INFORMATION Inspiratory pressure, cm H2O upto 50 or more
PRODUCT INFORMATION IE ratio 1:10 to 4:1
PRODUCT INFORMATION Sigh breath function Yes
PRODUCT INFORMATION Control panel lock Yes
PRODUCT INFORMATION Facility for double lung ventilation Yes
PATIENT ASSESSMENT TOOLS Number of loops 2 loops (P-V, F-V) with facility of saving of 1 Loops for reference
PATIENT ASSESSMENT TOOLS Lung recruitment tools (PV loops) / OLT (Open lung tools) Yes
PATIENT ASSESSMENT TOOLS Lung mechanics visualization tool Yes
PATIENT ASSESSMENT TOOLS Capnography/CO2 monitoring Yes
PATIENT ASSESSMENT TOOLS Esophageal / transpulmonary pressure monitoring Yes
PATIENT ASSESSMENT TOOLS APRV(Airway Pressure Release Ventilation) /Bivent/Bi level Yes
PATIENT ASSESSMENT TOOLS MMV(Mandatory Minute Ventilation) + PSV (Pressure Support Ventilation) /ASV( Adaptive Support Ventilation ) or ALPV(Adaptive Lung Protection Ventilation) or Automode Yes
PATIENT ASSESSMENT TOOLS PRVC(Pressure-Regulated Volume Control ventilation)/Auto flow Yes
PATIENT ASSESSMENT TOOLS High flow oxygen therapy Yes
PATIENT ASSESSMENT TOOLS Automatic weaning system provided Yes
PATIENT ASSESSMENT TOOLS Volume Support Yes
PATIENT ASSESSMENT TOOLS RSBI (Rapid Shallow Breathing Index) Yes
PATIENT ASSESSMENT TOOLS Expiratory Time constant ( Tcexp) Yes
PATIENT ASSESSMENT TOOLS Compliance static and/or dynamic Yes
PATIENT ASSESSMENT TOOLS Inspired and/or expired resistance Yes
PATIENT ASSESSMENT TOOLS Occlusion pressure Yes
PATIENT ASSESSMENT TOOLS Inspiratory and expiratory hold Yes
PATIENT ASSESSMENT TOOLS Spontaneous frequency Yes
PATIENT ASSESSMENT TOOLS Total peep, intrinsic peep, extrinsic peep Yes
PATIENT ASSESSMENT TOOLS Expiratory block is autoclavable and no routine calibration required Yes
PATIENT ASSESSMENT TOOLS Auto compensation for ET Tube Yes
PATIENT ASSESSMENT TOOLS Facility for automatic compliance & Leakage compensation for circuit available Yes
PATIENT ASSESSMENT TOOLS RS 232 out put port Yes
PATIENT ASSESSMENT TOOLS USB/Memory card Yes
PATIENT ASSESSMENT TOOLS Availability of Remote alarm/display port Yes
PATIENT ASSESSMENT TOOLS Facility to Report (vent alarms and patient status) Yes
PATIENT ASSESSMENT TOOLS HL/7 Compliant out put Yes
PATIENT ASSESSMENT TOOLS Type of coloured display LED/LCD/TFT
PATIENT ASSESSMENT TOOLS Display should be touch screen Yes
PATIENT ASSESSMENT TOOLS NIV (Non Invasive Ventilation) to be possible in all modes of ventilation available Yes
PATIENT ASSESSMENT TOOLS Minimum Size of display (±2%) 17.0
PATIENT ASSESSMENT TOOLS Graphic display have automatic scaling facility for waves Yes
HARDWARE AND ELECTRICAL REQUIREMENTS Provision of UPS Yes
HARDWARE AND ELECTRICAL REQUIREMENTS Backup time in hrs 2
HARDWARE AND ELECTRICAL REQUIREMENTS Built in air source Turbine (In built)
HARDWARE AND ELECTRICAL REQUIREMENTS Availability of stand alone compressor Yes, No
HARDWARE AND ELECTRICAL REQUIREMENTS Compressor shall provide an oil free Medical air, with Peak output flow should be minimum 150 LPM and Air quality complying with ISO compressed air purity class Yes, NA (for turbine)
HARDWARE AND ELECTRICAL REQUIREMENTS Seller shall ensure compatibility of compressor with ventilator Yes, NA (for Turbine)
HARDWARE AND ELECTRICAL REQUIREMENTS Nebulizer with particle size less than 3 micron Yes
ADDITIONAL ACCESSORIES Number of reusable silicon breathing circuits 2
ADDITIONAL ACCESSORIES Number of flow sensor 20 Disposable
ADDITIONAL ACCESSORIES Humidifier: Servo controlled with digital monitoring of inspired gas temperature with heating wire 1
WARRANTY Warranty (years) 3, 5 Or higher