Bid Publish Date
08-May-2026, 6:16 pm
Bid End Date
30-Jun-2026, 3:00 pm
EMD
₹18,48,000
Value
₹9,23,99,990
Location
Progress
Quantity
9980
Category
Supply of Prefabricated E-House Container
Bid Type
Two Packet Bid
Mumbai Port Trust invites bids for Supply of Prefabricated E-House Container, Installation of E-House Container, Supply of 6. 6kV HT VCB in MUMBAI, MAHARASHTRA. Quantity: 9980. Submission Deadline: 30-06-2026 15: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Supply of Prefabricated E-House Container
Supply of Prefabricated Containerized Substation E-House having IP54 enclosure with 2 hr fire rated thermal insulation sandwich panel suitable for accommodating HT LT switchgear panel transformers battery bank battery charger and APFC panels as per technical specification
Installation of E-House Container
Installation of the prefabricated containerized substation E-House at site including all necessary activities for proper placement and fixing as per OEM drawings and instructions of Engineer in charge
Supply of 6.6kV HT VCB GIS Switchgear Panel
Supply of 6.6kV Eco-Friendly Indoor type green GIS VCB Switchgear Panel with maximum system voltage 12kV 500MVA rupturing capacity comprising 2 incomer 1 buscoupler 2 outgoing feeders 2 transformer feeders and 2 set bus PT as per technical specification
Installation Testing Commissioning of HT Switchgear Panel
Installation testing and commissioning of the 6.6kV HT GIS VCB Switchgear Panel inside the E-House as per technical specification and in the presence of MbPA representative
Supply of 24V DC SMF VRLA Battery Bank
Supply of 24V DC SMF-VRLA Battery Bank of suitable load rating for HT and LT switchgear panels with minimum 1 hour backup including battery stand inter-battery wiring terminal connectors accessories and BHMS as per technical specification
Installation Testing Commissioning of Battery Bank
Installation testing and commissioning of 24V DC SMF-VRLA Battery Bank inside the E-House as per technical specification and in the presence of MbPA representative
Supply of Float and Float Cum Boost Charger
Supply of Float and Float-Cum Boost Charger suitable for battery bank including incoming and outgoing cables wires connection in HT switchgear and control panels with full wave rectification for 440V 3 phase 4 wire 50Hz AC input supply as per technical specification
Installation Testing Commissioning of Float Cum Boost Charger
Installation testing and commissioning of Float and Float cum Boost Charger inside the E-House as per technical specification and in the presence of MbPA representative
Supply of Indoor LT Switchgear Panel
Supply of IEC 61439 compliant OEM LT panel with TPN 2000A copper busbar 50KA 1 sec STC comprising 2 incomer ACB 1 buscoupler ACB 10 outgoing ACB 5 MCCB 400A 2 MCCB 250A 2 MCCB for APFC and 5 MCB outgoings as per technical specification
Installation Testing Commissioning of LT Switchgear Panel
Installation testing and commissioning of LT Switchgear Panel inside the E-House as per technical specification and in the presence of MbPA representative
Supply of 1000KVA Dry Type Transformer 2 Sets
Supply of 1000 KVA 6.6KV to 0.433KV DYN-11 copper wound AN cooling cast resin dry type indoor transformer IP00 with off load tap links WTI scanner class F insulation HT and LT cable boxes and standard accessories as per ECBC 2021 2 sets
Installation Testing Commissioning of Dry Type Transformer
Installation testing and commissioning of 1000KVA dry type transformer at site inside the E-House as per technical specification and in the presence of MbPA representative 2 numbers
Supply of Smart Local Monitoring HMI System
Supply of wall mounted Smart Local Monitoring HMI Box with Windows 10 IOT Intel Core i5 processor 8GB RAM 64GB memory 15.6 inch touch screen IEC 61850 Client Master application software for complete substation monitoring as per technical specification
Installation Testing Commissioning of Smart Monitoring System
Installation testing and commissioning of Smart Local Monitoring HMI System including integration with protection relays via IEC 61850 Ed 2 LAN as per technical specification and in the presence of MbPA representative
Supply of APFC Panel 200 KVAr 2 Sets
Supply of cubicle type free standing floor mounted APFC Panels of 200 KVAr capacity conforming to IEC 61439 with MCCB incomer capacitor banks detuned reactors APFC relay and all accessories as per technical specification 2 sets
Installation Testing Commissioning of APFC Panel
Installation testing and commissioning of APFC panels inside the E-House as per technical specification and in the presence of MbPA representative 2 numbers
Supply of Fire Alarm Detection System
Supply of fire detection and alarm system comprising fire alarm control panel multi-area detection module multi sensor heat and smoke detectors break glass manual call points indoor and outdoor alarm hooters with AC shutdown interlock as per technical specification
Installation Testing Commissioning of Fire Alarm System
Installation testing and commissioning of fire detection and alarm system as per technical specification and in the presence of MbPA representative
Supply of Fire Extinguishers
Supply of fire extinguishers as per IS 3034-1993 of suitable capacity and type for the E-House substation application complete with all accessories and mountings
Installation of Fire Extinguisher
Installation of fire extinguishers at designated locations inside the E-House as per directions of Engineer in charge
Supply of Split Air Conditioners with Controller
Supply of minimum 2 nos 2 Ton copper coil inverter split air conditioners of heavy duty industrial type along with AC controller for E-House control room as per technical specification similar to O General Hitachi Samsung or equivalent
Installation Testing Commissioning of Air Conditioners
Installation testing and commissioning of split air conditioners and AC controller inside the E-House as per technical specification and in the presence of MbPA representative
Supply of HT LT Touch Proof Termination Kits
Supply of suitable type touch proof termination kits as required for HT and LT power and control cables to and within the container equipment as per technical specification
Installation Testing Commissioning of Termination Kits
Installation testing and commissioning of HT and LT touch proof termination kits inside the E-House as per technical specification and in the presence of MbPA representative
Supply of UPS with Battery
Supply of 600VA UPS system along with SMF-VRLA battery conforming to JISC-8702 Pt 1 2 and 3 with single phase 230V AC 50Hz output for E-House emergency illumination complete with all accessories
Installation Testing Commissioning of UPS
Installation testing and commissioning of UPS system with battery inside the E-House as per technical specification and in the presence of MbPA representative
Supply and Making of Chemical Earthing Pits
Supply and making of chemical earthing pit using chemical earth electrode with minimum 25 Kg chemical powder cement concrete chamber 500x500x200mm CI RCC cover earthing rod 17.2mm dia 3 mtr long copper bonded 250 microns as per IS 3043-2018 and IEC 62561 16 numbers
GI Earthing Flat 50mm x 6mm for Substation Equipment
Supply and laying of galvanized MS earthing flat 50mm x 6mm for HT LT APFC battery charger and transformer body earthing of substation equipment as per technical specification
Copper Earthing Flat 50mm x 6mm for Transformer Neutral
Supply and laying of copper earthing flat 50mm x 6mm for transformer neutral earthing of the substation as per technical specification
Supply of HT XLPE Cable 3Cx240sqmm to Tank Bunder SS
Supply and delivery of XLPE insulated PVC sheathed armoured screened cable 3C x 240 sqmm 6.6kV UE 11kV E grade aluminium conductor as per IS 7098 Part 2 for 6.6kV feeder from Workshop Substation to Tank Bunder Substation
Supply of HT XLPE Cable 3Cx240sqmm to PV Dock SS
Supply and delivery of XLPE insulated PVC sheathed armoured screened cable 3C x 240 sqmm 6.6kV UE 11kV E grade aluminium conductor as per IS 7098 Part 2 for 6.6kV feeder from Workshop Substation to PandV Dock Substation
Supply of HT XLPE Cable 3Cx240sqmm to Central SS
Supply and delivery of XLPE insulated PVC sheathed armoured screened cable 3C x 240 sqmm 6.6kV UE 11kV E grade aluminium conductor as per IS 7098 Part 2 for 6.6kV feeder from Workshop Substation to Central Substation CSS
Supply of HT XLPE Cable 3Cx240sqmm to RO-RO PAX SS
Supply and delivery of XLPE insulated PVC sheathed armoured screened cable 3C x 240 sqmm 6.6kV UE 11kV E grade aluminium conductor as per IS 7098 Part 2 for 6.6kV feeder from Workshop Substation to RO-RO PAX Terminal Substation
Tracing and Cutting of Existing Buried HT Cable Feeder
Tracing out existing buried 6.6kV HT cable laid feeder identification of existing feeder cable puncture and cutting in presence of MbPA representative contractor to arrange all necessary testing kits required for the same
Supply of Straight Through HT Cable Joint Kit
Supply of straight through joint for HT cable 3C x 240 sqmm XLPE insulated armoured aluminium conductor 11kV E 6.6kV UE grade using heat shrinkable Raychem make jointing kit with ferrules tape etc complete in all respect
Making of HT Cable Straight Through Joint
Making of HT cable 6.6kV UE 11kV E grade straight through jointing work for cable 3C x 240 sqmm XLPE to XLPE in the presence of MbPA representative
High Potential Testing of HT Cable Joints
Carrying out necessary High Potential Test before and after making joints using calibrated testing equipment with complete test reports in the presence of MbPA representative
Phase Sequence Testing and Commissioning of HT Cable
Carrying out necessary Phase Sequence test using calibrated testing equipment with complete test reports and commissioning the cable in all respect in the presence of MbPA representative
Supply of Straight Through Transition HT Cable Joint Optional
Supply of straight through transition joint for HT cable 3C x 240 sqmm XLPE insulated armoured aluminium conductor 11kV E grade using heat shrinkable Raychem make jointing kit with ferrules tape etc complete in all respect Optional
Making of HT Cable Transition Joint PILC to XLPE Optional
Making of HT cable 6.6kV UE 11kV E grade straight through transition jointing work for cable 3C x 240 sqmm PILC to XLPE in the presence of MbPA representative Optional
Excavation of HT Cable Trench in Soft Soil or Asphalt
Excavating suitable trench for HT cable in any type of soft soil or asphalt including cleaning cable trenches tentative size 1.0 mtr W x 1.2 mtr D x 300 mtr L
HT Cable Trench Excavation in Concrete Road Optional
Excavating suitable trench for HT cable in concrete or stone road including cleaning cable trenches tentative size 1.0 mtr W x 1.2 mtr D x 85 mtr L Optional
Laying of HT XLPE Cable 3Cx240sqmm in Excavated Trench
Laying of incoming and outgoing 3C x 240 sqmm XLPE aluminium armoured cable in excavated cable trench at depth 1200mm including cleaning dressing providing screened sand and RCC tiles engraved MbPA 6600 Volts as per drawing
Laying of HT Cable in RCC Pipe or Existing Duct
Laying of HT cable in RCC pipe HDPE pipe existing duct or CC trench including all necessary activities as per specification
Supply of 200mm Dia RCC Pipe NP2 Class with Collars
Supply of RCC pipe 200mm dia NP2 class of standard length with collars including cement concreting closing ends of pipes after passing cable across road culverts drains etc
Laying of RCC Pipe and Fixing of Collars
Laying of RCC pipe 200mm dia NP2 class and fixing of collars at site including all necessary activities as per specification
Supply of LT XLPE Cable 3.5Cx400sqmm to FP 6A
Supply and delivery of 3.5C x 400 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 6A
Supply of LT XLPE Cable 3.5Cx400sqmm to FP 11
Supply and delivery of 3.5C x 400 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 11
Supply of LT XLPE Cable 3.5Cx300sqmm to FP 1A
Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 1A
Supply of LT XLPE Cable 3.5Cx300sqmm to FP 3
Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 3
Supply of LT XLPE Cable 3.5Cx300sqmm to FP 4
Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 4
Supply of LT XLPE Cable 3.5Cx300sqmm to FP 5
Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 5
Supply of LT XLPE Cable 3.5Cx300sqmm to FP 6B
Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 6B
Supply of LT XLPE Cable 3.5Cx300sqmm to FP 6C
Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 6C
LT Cable Trench Excavation in Asphalt Paver Area
Excavating suitable trench for LT cable in asphalt soil or paver block footpath with curb stone including cleaning cable trenches tentative size 0.8 mtr W x 0.9 mtr D x 700 mtr L
Laying of LT Cable 3.5Cx300 or 400sqmm in Excavated Trench
Laying of incoming and outgoing 3.5C x 300 or 400 sqmm LT XLPE armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification
Laying LT Cable 3.5Cx300 or 400sqmm in Pipe or Duct
Laying of incoming and outgoing 3.5C x 300 or 400 sqmm LT XLPE armoured cables in RCC pipe HDPE pipe existing duct CC trench or saddling on wall as per specification
Supply of LT XLPE Cable 3.5Cx70sqmm to Old CME Building
Supply and delivery of 3.5C x 70 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable for outgoing to old CME building SBI from FP No 4 Nirman Bhavan
Excavation of LT Cable Trench for 70sqmm Cable
Excavating suitable trench for LT cable in asphalt soil or paver block footpath with cup stone including cleaning cable trenches tentative size 0.8 mtr W x 0.9 mtr D x 150 mtr L
Laying of LT Cable 3.5Cx70sqmm in Excavated Trench
Laying of incoming and outgoing 3.5C x 70 sqmm LT XLPE armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification
Laying of LT Cable 3.5Cx70sqmm in RCC Pipe or Duct
Laying of incoming and outgoing 3.5C x 70 sqmm LT XLPE armoured cables in RCC pipe HDPE pipe existing duct CC trench or saddling on wall as per specification
Cable Termination Material for 3.5Cx70sqmm LT Cable
Supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 70 sqmm XLPE PVC cable 1100 volts grade 2 ends
Cable Termination Installation for 3.5Cx70sqmm LT Cable
Installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 70 sqmm XLPE PVC cable 1100 volts grade 2 ends
Cable Termination Material for 3.5Cx300sqmm LT Cable
Supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 300 sqmm XLPE PVC cable 1100 volts grade 6 ends
Cable Termination Installation for 3.5Cx300sqmm LT Cable
Installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 300 sqmm XLPE PVC cable 1100 volts grade 6 ends
Cable Termination Material for 3.5Cx400sqmm LT Cable
Supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 400 sqmm XLPE PVC cable 1100 volts grade 2 ends
Cable Termination Installation for 3.5Cx400sqmm LT Cable
Installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 400 sqmm XLPE PVC cable 1100 volts grade 2 ends
E-House Foundation Civil Work
Suitable quantity dimensions and grade of concrete for E-House foundation columns including soil excavation as per OEM design drawings and structural design approved by BMC registered structural engineer
E-House Shed Supply and Installation
Supply and installation of E-House shed including foundation columns I-beams angles and covering sheets as per design drawings approved by BMC registered structural engineer
Rubble Packing 250mm Thick for Cable Trench Reinstatement
Providing and laying approved quality rubble packing 250mm thick hand set including filling interstices with stone chips grit stone dust watering and consolidation as specified and as directed
Stone Metal 40-90mm Layer for Trench Reinstatement
Providing and laying 40mm to 90mm size stone metal of approved quality to required thickness in layers not exceeding 120mm consolidated with roller including filling interstices with grit stone dust sand as directed
Water Bound Macadam WBM Layer for Trench Reinstatement
Providing and laying water bound macadam WBM layer 100mm consolidated thickness with 40 to 63mm metal consolidated with roller including watering blending with sand stone dust grit brick powder as specified
M10 Grade RMC Concrete Levelling Course
Providing and laying M10 grade ready mix cement concrete from approved RMC plant in levelling course of required thickness including transit mixer form work plate vibrator curing etc as specified
M40 Grade RMC Concrete Road Pavement
Providing and laying M40 grade ready mix cement concrete from approved RMC plant in road pavement bays including form work power driven screed plate and needle vibrators brooming vatas bitumen curing as specified
Interlocking Paver Blocks 100mm Thick
Providing and laying approved coloured cement concrete interlocking paver blocks 100mm thick with sand bedding minimum 50mm and filling joints with fine sand as directed
Asphaltic Macadam Bitumen Grade 60 70 Regulating Course
Providing and laying hot pre-mixed asphaltic macadam Bitumen grade 60 70 with anti-stripping agent 0.5 percent by weight in regulating course and rolling with 8 to 10 tonne road roller as specified payment by weight
Asphaltic Concrete Wearing Course Bitumen Grade 60 70
Providing and laying hot pre-mixed asphaltic concrete wearing course Bitumen grade 60 70 with anti-stripping agent 0.50 percent by weight of required thickness and rolling with 8 to 10 tonne road roller as specified payment by weight
Transporting Surplus Excavated Material Outside MbPA Estate
Transporting surplus excavated material stones debris kutchra from MbPA estate including loading and taking away materials anywhere outside MbPA estate as directed
Dismantling of Existing Workshop Substation Equipment
Dismantling of existing HT LT panel transformers APFC panel battery charger and bank cables and cable terminations of existing workshop substation and shifting removed electrical equipment to MbPA store as per instructions of Engineer
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Supply of Prefabricated E-House Container | Supply of Prefabricated Containerized Substation E-House having IP54 enclosure with 2 hr fire rated thermal insulation sandwich panel suitable for accommodating HT LT switchgear panel transformers battery bank battery charger and APFC panels as per technical specification | 1 | job | [email protected] | 270 | |
| 2 | Installation of E-House Container | Installation of the prefabricated containerized substation E-House at site including all necessary activities for proper placement and fixing as per OEM drawings and instructions of Engineer in charge | 1 | job | [email protected] | 270 | |
| 3 | Supply of 6.6kV HT VCB GIS Switchgear Panel | Supply of 6.6kV Eco-Friendly Indoor type green GIS VCB Switchgear Panel with maximum system voltage 12kV 500MVA rupturing capacity comprising 2 incomer 1 buscoupler 2 outgoing feeders 2 transformer feeders and 2 set bus PT as per technical specification | 1 | job | [email protected] | 270 | |
| 4 | Installation Testing Commissioning of HT Switchgear Panel | Installation testing and commissioning of the 6.6kV HT GIS VCB Switchgear Panel inside the E-House as per technical specification and in the presence of MbPA representative | 1 | job | [email protected] | 270 | |
| 5 | Supply of 24V DC SMF VRLA Battery Bank | Supply of 24V DC SMF-VRLA Battery Bank of suitable load rating for HT and LT switchgear panels with minimum 1 hour backup including battery stand inter-battery wiring terminal connectors accessories and BHMS as per technical specification | 1 | set | [email protected] | 270 | |
| 6 | Installation Testing Commissioning of Battery Bank | Installation testing and commissioning of 24V DC SMF-VRLA Battery Bank inside the E-House as per technical specification and in the presence of MbPA representative | 1 | job | [email protected] | 270 | |
| 7 | Supply of Float and Float Cum Boost Charger | Supply of Float and Float-Cum Boost Charger suitable for battery bank including incoming and outgoing cables wires connection in HT switchgear and control panels with full wave rectification for 440V 3 phase 4 wire 50Hz AC input supply as per technical specification | 1 | set | [email protected] | 270 | |
| 8 | Installation Testing Commissioning of Float Cum Boost Charger | Installation testing and commissioning of Float and Float cum Boost Charger inside the E-House as per technical specification and in the presence of MbPA representative | 1 | job | [email protected] | 270 | |
| 9 | Supply of Indoor LT Switchgear Panel | Supply of IEC 61439 compliant OEM LT panel with TPN 2000A copper busbar 50KA 1 sec STC comprising 2 incomer ACB 1 buscoupler ACB 10 outgoing ACB 5 MCCB 400A 2 MCCB 250A 2 MCCB for APFC and 5 MCB outgoings as per technical specification | 1 | set | [email protected] | 270 | |
| 10 | Installation Testing Commissioning of LT Switchgear Panel | Installation testing and commissioning of LT Switchgear Panel inside the E-House as per technical specification and in the presence of MbPA representative | 1 | job | [email protected] | 270 | |
| 11 | Supply of 1000KVA Dry Type Transformer 2 Sets | Supply of 1000 KVA 6.6KV to 0.433KV DYN-11 copper wound AN cooling cast resin dry type indoor transformer IP00 with off load tap links WTI scanner class F insulation HT and LT cable boxes and standard accessories as per ECBC 2021 2 sets | 2 | sets | [email protected] | 270 | |
| 12 | Installation Testing Commissioning of Dry Type Transformer | Installation testing and commissioning of 1000KVA dry type transformer at site inside the E-House as per technical specification and in the presence of MbPA representative 2 numbers | 2 | jobs | [email protected] | 270 | |
| 13 | Supply of Smart Local Monitoring HMI System | Supply of wall mounted Smart Local Monitoring HMI Box with Windows 10 IOT Intel Core i5 processor 8GB RAM 64GB memory 15.6 inch touch screen IEC 61850 Client Master application software for complete substation monitoring as per technical specification | 1 | set | [email protected] | 270 | |
| 14 | Installation Testing Commissioning of Smart Monitoring System | Installation testing and commissioning of Smart Local Monitoring HMI System including integration with protection relays via IEC 61850 Ed 2 LAN as per technical specification and in the presence of MbPA representative | 1 | job | [email protected] | 270 | |
| 15 | Supply of APFC Panel 200 KVAr 2 Sets | Supply of cubicle type free standing floor mounted APFC Panels of 200 KVAr capacity conforming to IEC 61439 with MCCB incomer capacitor banks detuned reactors APFC relay and all accessories as per technical specification 2 sets | 2 | sets | [email protected] | 270 | |
| 16 | Installation Testing Commissioning of APFC Panel | Installation testing and commissioning of APFC panels inside the E-House as per technical specification and in the presence of MbPA representative 2 numbers | 2 | jobs | [email protected] | 270 | |
| 17 | Supply of Fire Alarm Detection System | Supply of fire detection and alarm system comprising fire alarm control panel multi-area detection module multi sensor heat and smoke detectors break glass manual call points indoor and outdoor alarm hooters with AC shutdown interlock as per technical specification | 1 | set | [email protected] | 270 | |
| 18 | Installation Testing Commissioning of Fire Alarm System | Installation testing and commissioning of fire detection and alarm system as per technical specification and in the presence of MbPA representative | 1 | job | [email protected] | 270 | |
| 19 | Supply of Fire Extinguishers | Supply of fire extinguishers as per IS 3034-1993 of suitable capacity and type for the E-House substation application complete with all accessories and mountings | 1 | set | [email protected] | 270 | |
| 20 | Installation of Fire Extinguisher | Installation of fire extinguishers at designated locations inside the E-House as per directions of Engineer in charge | 1 | job | [email protected] | 270 | |
| 21 | Supply of Split Air Conditioners with Controller | Supply of minimum 2 nos 2 Ton copper coil inverter split air conditioners of heavy duty industrial type along with AC controller for E-House control room as per technical specification similar to O General Hitachi Samsung or equivalent | 1 | set | [email protected] | 270 | |
| 22 | Installation Testing Commissioning of Air Conditioners | Installation testing and commissioning of split air conditioners and AC controller inside the E-House as per technical specification and in the presence of MbPA representative | 1 | job | [email protected] | 270 | |
| 23 | Supply of HT LT Touch Proof Termination Kits | Supply of suitable type touch proof termination kits as required for HT and LT power and control cables to and within the container equipment as per technical specification | 1 | set | [email protected] | 270 | |
| 24 | Installation Testing Commissioning of Termination Kits | Installation testing and commissioning of HT and LT touch proof termination kits inside the E-House as per technical specification and in the presence of MbPA representative | 1 | job | [email protected] | 270 | |
| 25 | Supply of UPS with Battery | Supply of 600VA UPS system along with SMF-VRLA battery conforming to JISC-8702 Pt 1 2 and 3 with single phase 230V AC 50Hz output for E-House emergency illumination complete with all accessories | 1 | set | [email protected] | 270 | |
| 26 | Installation Testing Commissioning of UPS | Installation testing and commissioning of UPS system with battery inside the E-House as per technical specification and in the presence of MbPA representative | 1 | job | [email protected] | 270 | |
| 27 | Supply and Making of Chemical Earthing Pits | Supply and making of chemical earthing pit using chemical earth electrode with minimum 25 Kg chemical powder cement concrete chamber 500x500x200mm CI RCC cover earthing rod 17.2mm dia 3 mtr long copper bonded 250 microns as per IS 3043-2018 and IEC 62561 16 numbers | 16 | set | [email protected] | 270 | |
| 28 | GI Earthing Flat 50mm x 6mm for Substation Equipment | Supply and laying of galvanized MS earthing flat 50mm x 6mm for HT LT APFC battery charger and transformer body earthing of substation equipment as per technical specification | 350 | mtrs | [email protected] | 270 | |
| 29 | Copper Earthing Flat 50mm x 6mm for Transformer Neutral | Supply and laying of copper earthing flat 50mm x 6mm for transformer neutral earthing of the substation as per technical specification | 100 | mtrs | [email protected] | 270 | |
| 30 | Supply of HT XLPE Cable 3Cx240sqmm to Tank Bunder SS | Supply and delivery of XLPE insulated PVC sheathed armoured screened cable 3C x 240 sqmm 6.6kV UE 11kV E grade aluminium conductor as per IS 7098 Part 2 for 6.6kV feeder from Workshop Substation to Tank Bunder Substation | 300 | mtrs | [email protected] | 270 | |
| 31 | Supply of HT XLPE Cable 3Cx240sqmm to PV Dock SS | Supply and delivery of XLPE insulated PVC sheathed armoured screened cable 3C x 240 sqmm 6.6kV UE 11kV E grade aluminium conductor as per IS 7098 Part 2 for 6.6kV feeder from Workshop Substation to PandV Dock Substation | 300 | mtrs | [email protected] | 270 | |
| 32 | Supply of HT XLPE Cable 3Cx240sqmm to Central SS | Supply and delivery of XLPE insulated PVC sheathed armoured screened cable 3C x 240 sqmm 6.6kV UE 11kV E grade aluminium conductor as per IS 7098 Part 2 for 6.6kV feeder from Workshop Substation to Central Substation CSS | 300 | mtrs | [email protected] | 270 | |
| 33 | Supply of HT XLPE Cable 3Cx240sqmm to RO-RO PAX SS | Supply and delivery of XLPE insulated PVC sheathed armoured screened cable 3C x 240 sqmm 6.6kV UE 11kV E grade aluminium conductor as per IS 7098 Part 2 for 6.6kV feeder from Workshop Substation to RO-RO PAX Terminal Substation | 125 | mtrs | [email protected] | 270 | |
| 34 | Tracing and Cutting of Existing Buried HT Cable Feeder | Tracing out existing buried 6.6kV HT cable laid feeder identification of existing feeder cable puncture and cutting in presence of MbPA representative contractor to arrange all necessary testing kits required for the same | 4 | nos | [email protected] | 270 | |
| 35 | Supply of Straight Through HT Cable Joint Kit | Supply of straight through joint for HT cable 3C x 240 sqmm XLPE insulated armoured aluminium conductor 11kV E 6.6kV UE grade using heat shrinkable Raychem make jointing kit with ferrules tape etc complete in all respect | 4 | nos | [email protected] | 270 | |
| 36 | Making of HT Cable Straight Through Joint | Making of HT cable 6.6kV UE 11kV E grade straight through jointing work for cable 3C x 240 sqmm XLPE to XLPE in the presence of MbPA representative | 4 | nos | [email protected] | 270 | |
| 37 | High Potential Testing of HT Cable Joints | Carrying out necessary High Potential Test before and after making joints using calibrated testing equipment with complete test reports in the presence of MbPA representative | 4 | jobs | [email protected] | 270 | |
| 38 | Phase Sequence Testing and Commissioning of HT Cable | Carrying out necessary Phase Sequence test using calibrated testing equipment with complete test reports and commissioning the cable in all respect in the presence of MbPA representative | 4 | jobs | [email protected] | 270 | |
| 39 | Supply of Straight Through Transition HT Cable Joint Optional | Supply of straight through transition joint for HT cable 3C x 240 sqmm XLPE insulated armoured aluminium conductor 11kV E grade using heat shrinkable Raychem make jointing kit with ferrules tape etc complete in all respect Optional | 2 | nos | [email protected] | 270 | |
| 40 | Making of HT Cable Transition Joint PILC to XLPE Optional | Making of HT cable 6.6kV UE 11kV E grade straight through transition jointing work for cable 3C x 240 sqmm PILC to XLPE in the presence of MbPA representative Optional | 2 | nos | [email protected] | 270 | |
| 41 | Excavation of HT Cable Trench in Soft Soil or Asphalt | Excavating suitable trench for HT cable in any type of soft soil or asphalt including cleaning cable trenches tentative size 1.0 mtr W x 1.2 mtr D x 300 mtr L | 360 | cum | [email protected] | 270 | |
| 42 | HT Cable Trench Excavation in Concrete Road Optional | Excavating suitable trench for HT cable in concrete or stone road including cleaning cable trenches tentative size 1.0 mtr W x 1.2 mtr D x 85 mtr L Optional | 102 | cum | [email protected] | 270 | |
| 43 | Laying of HT XLPE Cable 3Cx240sqmm in Excavated Trench | Laying of incoming and outgoing 3C x 240 sqmm XLPE aluminium armoured cable in excavated cable trench at depth 1200mm including cleaning dressing providing screened sand and RCC tiles engraved MbPA 6600 Volts as per drawing | 925 | mtrs | [email protected] | 270 | |
| 44 | Laying of HT Cable in RCC Pipe or Existing Duct | Laying of HT cable in RCC pipe HDPE pipe existing duct or CC trench including all necessary activities as per specification | 270 | mtrs | [email protected] | 270 | |
| 45 | Supply of 200mm Dia RCC Pipe NP2 Class with Collars | Supply of RCC pipe 200mm dia NP2 class of standard length with collars including cement concreting closing ends of pipes after passing cable across road culverts drains etc | 300 | mtrs | [email protected] | 270 | |
| 46 | Laying of RCC Pipe and Fixing of Collars | Laying of RCC pipe 200mm dia NP2 class and fixing of collars at site including all necessary activities as per specification | 300 | mtrs | [email protected] | 270 | |
| 47 | Supply of LT XLPE Cable 3.5Cx400sqmm to FP 6A | Supply and delivery of 3.5C x 400 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 6A | 150 | mtrs | [email protected] | 270 | |
| 48 | Supply of LT XLPE Cable 3.5Cx400sqmm to FP 11 | Supply and delivery of 3.5C x 400 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 11 | 400 | mtrs | [email protected] | 270 | |
| 49 | Supply of LT XLPE Cable 3.5Cx300sqmm to FP 1A | Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 1A | 125 | mtrs | [email protected] | 270 | |
| 50 | Supply of LT XLPE Cable 3.5Cx300sqmm to FP 3 | Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 3 | 400 | mtrs | [email protected] | 270 | |
| 51 | Supply of LT XLPE Cable 3.5Cx300sqmm to FP 4 | Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 4 | 325 | mtrs | [email protected] | 270 | |
| 52 | Supply of LT XLPE Cable 3.5Cx300sqmm to FP 5 | Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 5 | 125 | mtrs | [email protected] | 270 | |
| 53 | Supply of LT XLPE Cable 3.5Cx300sqmm to FP 6B | Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 6B | 125 | mtrs | [email protected] | 270 | |
| 54 | Supply of LT XLPE Cable 3.5Cx300sqmm to FP 6C | Supply and delivery of 3.5C x 300 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable heavy duty conforming to IS 1554 7098 Part-I for outgoing to Feeder Pillar 6C | 125 | mtrs | [email protected] | 270 | |
| 55 | LT Cable Trench Excavation in Asphalt Paver Area | Excavating suitable trench for LT cable in asphalt soil or paver block footpath with curb stone including cleaning cable trenches tentative size 0.8 mtr W x 0.9 mtr D x 700 mtr L | 504 | cum | [email protected] | 270 | |
| 56 | Laying of LT Cable 3.5Cx300 or 400sqmm in Excavated Trench | Laying of incoming and outgoing 3.5C x 300 or 400 sqmm LT XLPE armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification | 1,575 | mtrs | [email protected] | 270 | |
| 57 | Laying LT Cable 3.5Cx300 or 400sqmm in Pipe or Duct | Laying of incoming and outgoing 3.5C x 300 or 400 sqmm LT XLPE armoured cables in RCC pipe HDPE pipe existing duct CC trench or saddling on wall as per specification | 200 | mtrs | [email protected] | 270 | |
| 58 | Supply of LT XLPE Cable 3.5Cx70sqmm to Old CME Building | Supply and delivery of 3.5C x 70 sqmm aluminium conductor XLPE insulated PVC sheathed 1100 volts grade armoured cable for outgoing to old CME building SBI from FP No 4 Nirman Bhavan | 250 | mtrs | [email protected] | 270 | |
| 59 | Excavation of LT Cable Trench for 70sqmm Cable | Excavating suitable trench for LT cable in asphalt soil or paver block footpath with cup stone including cleaning cable trenches tentative size 0.8 mtr W x 0.9 mtr D x 150 mtr L | 108 | cum | [email protected] | 270 | |
| 60 | Laying of LT Cable 3.5Cx70sqmm in Excavated Trench | Laying of incoming and outgoing 3.5C x 70 sqmm LT XLPE armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification | 160 | mtrs | [email protected] | 270 | |
| 61 | Laying of LT Cable 3.5Cx70sqmm in RCC Pipe or Duct | Laying of incoming and outgoing 3.5C x 70 sqmm LT XLPE armoured cables in RCC pipe HDPE pipe existing duct CC trench or saddling on wall as per specification | 90 | mtrs | [email protected] | 270 | |
| 62 | Cable Termination Material for 3.5Cx70sqmm LT Cable | Supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 70 sqmm XLPE PVC cable 1100 volts grade 2 ends | 2 | nos | [email protected] | 270 | |
| 63 | Cable Termination Installation for 3.5Cx70sqmm LT Cable | Installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 70 sqmm XLPE PVC cable 1100 volts grade 2 ends | 2 | nos | [email protected] | 270 | |
| 64 | Cable Termination Material for 3.5Cx300sqmm LT Cable | Supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 300 sqmm XLPE PVC cable 1100 volts grade 6 ends | 6 | nos | [email protected] | 270 | |
| 65 | Cable Termination Installation for 3.5Cx300sqmm LT Cable | Installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 300 sqmm XLPE PVC cable 1100 volts grade 6 ends | 6 | nos | [email protected] | 270 | |
| 66 | Cable Termination Material for 3.5Cx400sqmm LT Cable | Supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 400 sqmm XLPE PVC cable 1100 volts grade 2 ends | 2 | nos | [email protected] | 270 | |
| 67 | Cable Termination Installation for 3.5Cx400sqmm LT Cable | Installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5C x 400 sqmm XLPE PVC cable 1100 volts grade 2 ends | 2 | nos | [email protected] | 270 | |
| 68 | E-House Foundation Civil Work | Suitable quantity dimensions and grade of concrete for E-House foundation columns including soil excavation as per OEM design drawings and structural design approved by BMC registered structural engineer | 1 | job | [email protected] | 270 | |
| 69 | E-House Shed Supply and Installation | Supply and installation of E-House shed including foundation columns I-beams angles and covering sheets as per design drawings approved by BMC registered structural engineer | 1 | job | [email protected] | 270 | |
| 70 | Rubble Packing 250mm Thick for Cable Trench Reinstatement | Providing and laying approved quality rubble packing 250mm thick hand set including filling interstices with stone chips grit stone dust watering and consolidation as specified and as directed | 690 | sqr mtr | [email protected] | 270 | |
| 71 | Stone Metal 40-90mm Layer for Trench Reinstatement | Providing and laying 40mm to 90mm size stone metal of approved quality to required thickness in layers not exceeding 120mm consolidated with roller including filling interstices with grit stone dust sand as directed | 71 | cum | [email protected] | 270 | |
| 72 | Water Bound Macadam WBM Layer for Trench Reinstatement | Providing and laying water bound macadam WBM layer 100mm consolidated thickness with 40 to 63mm metal consolidated with roller including watering blending with sand stone dust grit brick powder as specified | 185 | sqr mtr | [email protected] | 270 | |
| 73 | M10 Grade RMC Concrete Levelling Course | Providing and laying M10 grade ready mix cement concrete from approved RMC plant in levelling course of required thickness including transit mixer form work plate vibrator curing etc as specified | 38 | cum | [email protected] | 270 | |
| 74 | M40 Grade RMC Concrete Road Pavement | Providing and laying M40 grade ready mix cement concrete from approved RMC plant in road pavement bays including form work power driven screed plate and needle vibrators brooming vatas bitumen curing as specified | 29 | cum | [email protected] | 270 | |
| 75 | Interlocking Paver Blocks 100mm Thick | Providing and laying approved coloured cement concrete interlocking paver blocks 100mm thick with sand bedding minimum 50mm and filling joints with fine sand as directed | 95 | sq mtr | [email protected] | 270 | |
| 76 | Asphaltic Macadam Bitumen Grade 60 70 Regulating Course | Providing and laying hot pre-mixed asphaltic macadam Bitumen grade 60 70 with anti-stripping agent 0.5 percent by weight in regulating course and rolling with 8 to 10 tonne road roller as specified payment by weight | 135 | mt | [email protected] | 270 | |
| 77 | Asphaltic Concrete Wearing Course Bitumen Grade 60 70 | Providing and laying hot pre-mixed asphaltic concrete wearing course Bitumen grade 60 70 with anti-stripping agent 0.50 percent by weight of required thickness and rolling with 8 to 10 tonne road roller as specified payment by weight | 150 | mt | [email protected] | 270 | |
| 78 | Transporting Surplus Excavated Material Outside MbPA Estate | Transporting surplus excavated material stones debris kutchra from MbPA estate including loading and taking away materials anywhere outside MbPA estate as directed | 100 | cum | [email protected] | 270 | |
| 79 | Dismantling of Existing Workshop Substation Equipment | Dismantling of existing HT LT panel transformers APFC panel battery charger and bank cables and cable terminations of existing workshop substation and shifting removed electrical equipment to MbPA store as per instructions of Engineer | 1 | job | [email protected] | 270 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
30-Jun-2026, 3:00 pm
Opening Date
30-Jun-2026, 3:30 pm
Extended Deadline
23-Jun-2026, 3:00 pm
Opening Date
23-Jun-2026, 3:30 pm
Sign up now to access all documents
Main Document
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS