GEM

Open Tender for Automated HPLC System for Separation of complex mixtures in PUNE, MAHARASHTRA

Bid Publish Date

22-Dec-2025, 11:55 am

Bid End Date

12-Jan-2026, 12:00 pm

EMD

₹1,20,000

Progress

Issue22-Dec-2025, 11:55 am
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 14

A tender has been published for National Centre For Cell Sciences (nccs) Automated HPLC System for Separation of complex mixtures (Q3) in PUNE, MAHARASHTRA. Quantity: 1 by. Submission Deadline: 12-01-2026 12: 00: 00. Check eligibility and apply.

Past Similar Tenders (Historical Results)

5 found

Automated HPLC System for Separation of complex mixtures

N/a

DURG, CHHATTISGARH

Posted: 23 January 2025
Closed: 7 February 2025
GEM

Automated HPLC System for Separation of complex mixtures

N/a

BANDA, UTTAR PRADESH

Posted: 11 February 2025
Closed: 25 February 2025
GEM

Automated HPLC System for Separation of complex mixtures

Indian Council Of Agricultural Research (icar)

Posted: 11 October 2024
Closed: 28 November 2024
GEM

Automated HPLC System for Separation of complex mixtures

Gujarat Technological University Ahmedabad

GANDHI NAGAR, GUJARAT

Posted: 6 January 2025
Closed: 13 February 2025
GEM

Automated HPLC System for Separation of complex mixtures

N/a

GANDHI NAGAR, GUJARAT

Posted: 7 October 2025
Closed: 12 November 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Standard parameter Instrument calibration standards NA
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Components of unit Quaternary Low Pressure Gradient pump & Serial Double Plunger
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Number of solvents delivery 4
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Flow rate setting range in ml/min 0.001 to 10
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Flow rate accuracy ± 0.1%
UV-Vis Detector UV-Vis Detector provided Yes, No Or higher
UV-Vis Detector Light source NA if not provided
UV-Vis Detector Spectrum Band width in nm NA if not provided
UV-Vis Detector Wavelength range in nm NA if not provided
UV-Vis Detector Sampling Rate in Hz NA if not provided
UV-Vis Detector The flow cell must be temperature Controlled NA if not provided
UV-Vis Detector Wavelength accuracy in nm NA if not provided
UV-Vis Detector Wavelength reproducibility in nm NA if not provided
UV-Vis Detector Drift in AU/Hour NA if not provided
UV-Vis Detector Noise level in AU NA if not provided
UV-Vis Detector Ability to monitor and quantitative 2 wavelengths simultaneously NA if not provided
UV-Vis Detector Linearity in AU NA if not provided
UV-Vis Detector Temperature control provided for Flow cell NA if not provided
UV-Vis Detector Temperature control range for flow cell in Degree Celsius NA if not provided
UV-Vis Detector flow cell path length in mm NA if not provided
UV-Vis Detector Flow cell volume in ?l NA if not provided
Auto Sample Injector with cooler Injection Method Total volume sample injection
Auto Sample Injector with cooler Carry over of sample 0.005% or lower
Auto Sample Injector with cooler Injection precision in RSD less than 0.50 % RSD
Software Operating Windows Win 10 or latest
Photo Diode Array (PDA) Detector Provision of Photo diode array Yes Or higher
Photo Diode Array (PDA) Detector PDA detector Wavelength range in nm 190- 800 or better
Photo Diode Array (PDA) Detector Number of Diodes 1024
Photo Diode Array (PDA) Detector PDA detector light source Deuterium lamp and Tungsten lamp
Photo Diode Array (PDA) Detector PDA detector Wavelength accuracy in nm ± 1
Photo Diode Array (PDA) Detector Data Rate in Hz 100, <100
Photo Diode Array (PDA) Detector Noise in AU less than ± 0.6 x 10-5 or lower
Photo Diode Array (PDA) Detector PDA detector Drift in AU/Hour less than 1 x 10-3
Photo Diode Array (PDA) Detector Temperature controlled flow cell in C NA if not provided
Photo Diode Array (PDA) Detector Flow cell Flow cell
Warranty & Reports Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 2, 3, 4, 5 Or higher
Warranty & Reports Number of installations in Central /State/PSU Govt Hospitals <3, >3
Warranty & Reports Availability of toll free facility for technical support maintained by OEM or authorized agencies Yes Or higher

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer