Bid Publish Date
18-Jul-2026, 3:30 pm
Bid End Date
28-Jul-2026, 4:00 pm
Location
Progress
Quantity
26
Category
Dismantling and shifting of 33KV VCB
Bid Type
Two Packet Bid
Organization: Uttar Pradesh Power Corporation Limited (UPPCL) • Product/Service: Dismantling, shifting, erection of 33 KV VCBs, foundation modification, jumper between equipments, earthing, cable termination, transportation of VCBs, CT handling, and loading/unloading of cable drums. Location: Sultanpur, Uttar Pradesh 222301. Scope includes dismantling and re-erection of VCBs up to 33/36 KV, CT dismantling, LA erection, and cable drum carriage. Delivery window: completion within 30 days from LOI/Agreement, subject to shutdown availability. Payment terms: 90% on site completion; BTS portal bill submission for processing. Penalties: 0.5% per week up to a maximum of 10% of late completion. Unique clause allows quantity variation up to 25% with contracted rates.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Dismantling and shifting of 33KV VCB , Modification of 33 KV VCB Foundation , Erection of new 33 KV VCB , Jumpering between equipments , Re Earthing of VCB , Cable Termination , Shifting Loading of 36 KV VCB , Transportation of VCB on hired private Vehicle , Safe unloading and shifting of VCB , Loading Unloadinfg and carriage of CT , Dismantling of CT , Erection work of CT , Erection of LA , Carriage of Cable drums of different sizes
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Sultanpur
Delivery Pincodes
228001
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Ritesh Kumar | 228001,ELECTRICITY TRANSMISSION SUB DIVISION-II 400 KV CAMPUS PAYAGIPUR SULTANPUR | Sultanpur | Uttar Pradesh | 228001 | 1 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Dismantling and shifting of 33KV VCB
Dismantling of 33 KV damaged and defective VCB including shifting of dismantled VCB form switch yard to storage place or store room
Modification of 33 KV VCB Foundation
Modification of 33 KV VCB foundation as per site requirement as per manufacturing drawing or as per direction of supervising Engineer and shifting of earthing and both side jumper
Erection of new 33 KV VCB
Erection of new 33 KV VCB in proper alignment and cable termination of circuit breaker as per logic for tripping and closing spring charging indication supervision circuit with proper ferruling and checking out of breaker operation from local and remote including earthing and connection of both side jumpers and works related to complete the erection work
Jumpering between equipments
Making of new jumpering between CB toTC CB to BI with twin ACSR panther conductor with the help of PG or CB clamp
Re Earthing of VCB
ReEarthing of 36 KV Circuit breaker by cutting bending and welding of 50x6 mm MS Flat to existing riser work includes checking of existing near connectivity to earth mat painting of existing riser earth flat earth flat with one cost of red oxide and two coat of black or bus green enamel paint of standard make after cleaning of strip angle for rust and dust
Cable Termination
Opening of termintion wiring from damaged breaker after writing the ferrule and tallying the ferrule with electrical drawing The work include complete identification of wiring then opening of wiring from panel and breaker end Then after reelection of new breaker the old wiring ferrule will be replaced the as per new drawing terminated for proper electrical working
Shifting Loading of 36 KV VCB
Safe loading of new 36 KV VCB at 132 KV Sub Station Kadipur on hired private vehicle with the help of Hydra The work includes shifting of VCB from storage place to loading point by manpower
Transportation of VCB on hired private Vehicle
Safe Transportation of new 36 KV VCB by hired private vehicle from 132 KV Sub Station Kadipur to 132 KV Sub Station Lambhua Distance approx 20 Kms
Safe unloading and shifting of VCB
Safe unloading the new 36 KV VCB brought from 132 KV SubStation Kadipur from vehicle with the help of hydra at 132 KV Sub Station Lambhua and shifting it by manpower to 1 the designated place as per instructions of JE incharge
Loading Unloadinfg and carriage of CT
Loading unloading and safe Carriage of 33 KV CT 03 Nos From 132 KV Substation Gauriganj to 132 KV SS Lambhua and unloading the same
Dismantling of CT
Dismantling of 36 KV CT 400 200 1A
Erection work of CT
Erection of new 33 KV CT Including all associated Work
Erection of LA
Erection of 30 KV LA
Carriage of Cable drums of different sizes
Safe carriage of cable drums of various size from 440kV Cental store sultanpur to 132kV SS Gosahsinghpur
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Dismantling and shifting of 33KV VCB | Dismantling of 33 KV damaged and defective VCB including shifting of dismantled VCB form switch yard to storage place or store room | 1 | job | ae@slt2 | 30 | |
| 2 | Modification of 33 KV VCB Foundation | Modification of 33 KV VCB foundation as per site requirement as per manufacturing drawing or as per direction of supervising Engineer and shifting of earthing and both side jumper | 1 | job | ae@slt2 | 30 | |
| 3 | Erection of new 33 KV VCB | Erection of new 33 KV VCB in proper alignment and cable termination of circuit breaker as per logic for tripping and closing spring charging indication supervision circuit with proper ferruling and checking out of breaker operation from local and remote including earthing and connection of both side jumpers and works related to complete the erection work | 1 | job | ae@slt2 | 30 | |
| 4 | Jumpering between equipments | Making of new jumpering between CB toTC CB to BI with twin ACSR panther conductor with the help of PG or CB clamp | 1 | job | ae@slt2 | 30 | |
| 5 | Re Earthing of VCB | ReEarthing of 36 KV Circuit breaker by cutting bending and welding of 50x6 mm MS Flat to existing riser work includes checking of existing near connectivity to earth mat painting of existing riser earth flat earth flat with one cost of red oxide and two coat of black or bus green enamel paint of standard make after cleaning of strip angle for rust and dust | 1 | job | ae@slt2 | 30 | |
| 6 | Cable Termination | Opening of termintion wiring from damaged breaker after writing the ferrule and tallying the ferrule with electrical drawing The work include complete identification of wiring then opening of wiring from panel and breaker end Then after reelection of new breaker the old wiring ferrule will be replaced the as per new drawing terminated for proper electrical working | 1 | job | ae@slt2 | 30 | |
| 7 | Shifting Loading of 36 KV VCB | Safe loading of new 36 KV VCB at 132 KV Sub Station Kadipur on hired private vehicle with the help of Hydra The work includes shifting of VCB from storage place to loading point by manpower | 1 | no | ae@slt2 | 30 | |
| 8 | Transportation of VCB on hired private Vehicle | Safe Transportation of new 36 KV VCB by hired private vehicle from 132 KV Sub Station Kadipur to 132 KV Sub Station Lambhua Distance approx 20 Kms | 1 | no | ae@slt2 | 30 | |
| 9 | Safe unloading and shifting of VCB | Safe unloading the new 36 KV VCB brought from 132 KV SubStation Kadipur from vehicle with the help of hydra at 132 KV Sub Station Lambhua and shifting it by manpower to 1 the designated place as per instructions of JE incharge | 1 | no | ae@slt2 | 30 | |
| 10 | Loading Unloadinfg and carriage of CT | Loading unloading and safe Carriage of 33 KV CT 03 Nos From 132 KV Substation Gauriganj to 132 KV SS Lambhua and unloading the same | 3 | no | ae@slt2 | 30 | |
| 11 | Dismantling of CT | Dismantling of 36 KV CT 400 200 1A | 3 | no | ae@slt2 | 30 | |
| 12 | Erection work of CT | Erection of new 33 KV CT Including all associated Work | 3 | no | ae@slt2 | 30 | |
| 13 | Erection of LA | Erection of 30 KV LA | 3 | no | ae@slt2 | 30 | |
| 14 | Carriage of Cable drums of different sizes | Safe carriage of cable drums of various size from 440kV Cental store sultanpur to 132kV SS Gosahsinghpur | 5 | no | ae@slt2 | 30 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS