TenderDekho Logo
GEM

Open Tender for Visit charges to attend fault of DEA Set,General Servicing of the Up to 20 KVA DEA sets,General Ser in JAIPUR, RAJASTHAN

Bid Publish Date

06-Aug-2025, 5:00 pm

Bid End Date

29-Aug-2025, 3:00 pm

EMD

₹57,275

Value

₹28,63,773

Progress

RA
Issue06-Aug-2025, 5:00 pm
Reverse AuctionCompleted
AwardCompleted
Explore all 4 tabs to view complete tender details

Quantity

5339

Category

General Servicing of More Than 32.5 KVA and up to 55 KVA DEA Sets

Bid Type

Two Packet Bid

Categories 193

PLATFORM SCALE PUSH BUTTON SWITCHES AXLE ALTERNATOR RING POWER CABLE CABBING EQUIPMENTS AIR CYLINDERS VEHICLE CONTROL WIRE PIPE PROJECT TUBE AND FITTING DECORATION AIR COOLED ENGINE BUS CABLE WIRING ASSEMBLY HEATING EQUIPMENTS SPRAYER DIRECT TRANSFORMER RADIO FREQUENCY ANALYSER GEYSER COUNTER WELDING BRAZING AND SOLDERING SERVICES BATTERY CHARGERS STEEL WIRE LIGHTENING PROTECTION DEVICE WATTMETERS PETROLEUM PRODUCT SOIL EARTH AMC OF ELECTRONIC GENERATOR SPARE COOLANT ARTICULATING LAZY ARMS SYNCHRONOUS MOTORS ULTRACENTRIFUGES MICRO CONTROLLER ENGINE OIL MATERIAL UNLOADING TRANSPORTATION ENGINE POWER CONTROL CABLE BUS TERMINAL COILED CABLE LFH CABLE MACHINING AND PROCESSING SERVICES PVC CABLE MACHINE BELT PNEUMATIC PRESSURE GAUGE LUBRICANT PRODUCT ROTARY CAM PUMPS VALVES WEIGH BRIDGE THERMOWELLS DRAINAGE WATER GENERATOR CHAIN PULLEY TRANSPORTATION OF DIESEL EXCITATION SYSTEM SANITARY FITTING WIRE FILTER RETAINERS BRONZE PIPE WORM GEAR ROUTINE MAINTENANCE SMART POSITIONER FILLING RAIN CUT SLIDER VALVES DIAPHRAGM PUMPS PYROMETERS HYDRAULIC CYLINDER LUBE OIL MS PIPE LINE SANITIZER BATTERY VALVE PARTS AND ACCESSORIES CANOPY INSULATED CABLE ARM CHAIR PEB PULLEY UPVC PIPE MINERAL WEIGHTS SLEEVE BEARING BP INSTRUMENT WIND MILL ENERGY PROJECT DECIBEL METER APFC PANEL ARCHERY BOW STRINGS CENTRIFUGE BRUSHES FUSES PARAMETER TEST ISDN BICYCLE CONING OIL TESTING INSTRUMENT PERISTALTIC PUMPS ARNO STARTING CONTACTOR MOBIL OIL DISTRIBUTION?BOX WHEAT FLOUR BEARINGS BUSHINGS AND GEARS AMPS LUBRICATING OILS SWITCHING APPARATUS ARC VALVE HARDWARE AND FASTENERS JOINTING OF PIPE SILVER TIP ELECTRICAL WIRE XLPE CABLE RUBBER GASKET SNG WOODEN FLOORING ALTERNATOR FAN SPARE PARTS INSTRUMENTATION CABLE COATING SERVICES MI TANK STATIC CONVERTERS MUSICAL INSTRUMENT PARTS AND ACCESSORIES WATER DRAINAGE THICKNESS GAUGE MINING ENGINEERING ENGINE PARTS WINDING MACHINE MAINTENANCE CONTRACT OF ELECTRONIC CONDUCTOR PRESSURE WASHER CABLING SEALING RING BUCKET CONVEYORS MACHINE OIL AC PIPES PNEUMATIC POSITIONER PETROLEUM FUELS V-BELT AUDIOMETERS EMG MACHINE METER READING WORK SWITCH GEAR VOLTMETER EARTH AND STONE HOOK UP WIRES BRAZE RINGS DIODE GLUCOMETER ALTERNATING CURRENT MOTOR ELECTRON TUBE GL WIRE CHANGE OVER SWITCH GASKETS AND SEALS PLAIN BEARING POWER WIRE AC MOTORS TECHNICAL SERVICES VALVE WATER LEVEL RECORDER WATER SUPPLY MATERIAL FUME HOODS BODYWEIGHT MEASURING SCALE FLUE GAS BUSHING FLUORESCENT LAMP LFH WIRE PIPE LAYING INDUCTION MOTORS BARE CABLE PROGRESSIVE CAVITY PUMPS SUPPLY OF ENGINE BACKHOE TRANSITION METALS ANGLE BRACKETS TRANSPORT CABLE STARTER HOSE PIPE RECTIFIERS GAS PIPELINE FILTERS EXCAVATION WATER COOLED ENGINE BUNDI ERECTION OF PIPE CABLE SUPPLY ELECTROMAGNET EARTH MOVING LUBRICANT CONSTRUCTION MEDICAL DIAGNOSTIC GAMMA CAMERAS SMPS AC AND DC POWER SUPPLY LABOUR

A tender has been published for Bharat Sanchar Nigam Limited Portal(bsnl) Visit charges to attend fault of DEA Set, General Servicing of the Up to 20 KVA DEA sets, General Ser in JAIPUR, RAJASTHAN. Quantity: 5339 by. Submission Deadline: 29-08-2025 15: 00: 00. Check eligibility and apply.

Documents 5

GeM-Bidding-8185518.pdf

Main Document

BOQ Document

BOQ

BOQ Document

BOQ

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Bill of Quantities (BOQ) 88 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 Visit charges to attend fault of DEA Set Visit charges to attend fault of DEA Set on call basis / complaint basis on behalf of written Job order from SDE(E) concerned for different TE / BTS sites under jurisidication including attending the minor faults involving no material and submit detailed report for major fault to the Engineering -In-charge i/c fare charges to visit the site from HQ etc complete as reqd. 25 job satcj75@bsnl 365
2 General Servicing of the Up to 20 KVA DEA sets Pdg & Making of General Servicing of the Up to 20 KVA DEA sets of different make and model installed at TE/BTS Sites comprising of following jobs i/c Fare and labour charge i/c complete checking of E/A Set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd. 60 job satcj75@bsnl 365
3 General Servicing of More Than 20 KVA and Upto 32.5 KVA DEA Sets Pdg & Making of General Servicing of the More Than 20 KVA & Upto 32.5 KVA DEA Sets of different make and model installed at TE/BTS Sites comprising of following jobs i/c Fare and labour charge i/c complete checking of E/A Set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd. 30 job satcj75@bsnl 365
4 General Servicing of More Than 32.5 KVA and up to 55 KVA DEA Sets Pdg & Making of General Servicing of the More Than 32.5 KVA & up to 55 KVA DEA Sets of different make and model installed at TE/BTS Sites comprising of following jobs i/c Fare and labour charge i/c complete checking of E/A Set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd. 10 job satcj75@bsnl 365
5 Replacement of Diesel Filter Element Set 1 Ltr Replacement of Diesel Filter Element Set ( 1 Ltr ) in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 23 set satcj75@bsnl 365
6 Replacement of Oil Filter Element 1 by 2 Ltr Replacement of Oil Filter Element ( 1/2 Ltr ) in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 78 number satcj75@bsnl 365
7 Replacement of Oil Filter Element 1 Ltr Replacement of Oil Filter Element ( 1 Ltr ) in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 18 number satcj75@bsnl 365
8 Replacement of Diesel Filter Element Set 1 by 2 Ltr Replacement of Oil Filter Element ( 1 Ltr ) in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 78 set satcj75@bsnl 365
9 Replacement of Oil Filter Set suitable for EA Set of 50 to 55 KVA Replacement of Oil Filter Set suitable for E/A Set of 50/55 KVA in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 8 number satcj75@bsnl 365
10 Replacement of Lubricating Oil Multi Grade 20W40 Replacement of Lubricating Oil Multi Grade ( 20W40) in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 990 liter satcj75@bsnl 365
11 Replacement of Steel Wire Braided Fuel Pipe Line Replacement of Steel Wire Braided Fuel Pipe Line in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 215 meter satcj75@bsnl 365
12 Replacement of Stop Solenoid 12 Volt Replacement of Stop Solenoid 12 Volt in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 2 number satcj75@bsnl 365
13 Replacement of Starting Key with Switch Replacement of Starting Key with Switch in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 11 number satcj75@bsnl 365
14 Replacement of Mechanical Type RPM Cum Hr Meter Replacement of Mechanical Type RPM Cum Hr Meter in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 2 number satcj75@bsnl 365
15 Replacement of Mechanical Type RPM Cum HR Meter Chain Replacement of Mechanical Type RPM Cum HR Meter Chain in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 2 number satcj75@bsnl 365
16 Replacement of Battery Leads Red and Black Replacement of Battery Leads Red & Black Standard Length & Size i/c terminals in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 38 set satcj75@bsnl 365
17 Replacement of Coolant for Radiator of superior quality Replacement of Coolant for Radiator of superior quality or as recommended by manufacturer in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 70 liter satcj75@bsnl 365
18 Replacement of V belt Replacement of V-belt in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 12 number satcj75@bsnl 365
19 Replacement of Hose pipe set with clips Replacement of Hose pipe set with clips in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 6 set satcj75@bsnl 365
20 Replacement of Techo Drive Unit Replacement of Techo Drive Unit in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 2 number satcj75@bsnl 365
21 Replacement of Fuel Feed Pump assembly Replacement of Fuel Feed Pump assembly in existing Different capacity and make of Engines I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 16 number satcj75@bsnl 365
22 Replacement of Solid state SMPS or SCR based battery chargers Replacement of Solid state SMPS or SCR based battery chargers in existing Different capacity and make E/A Set AMF / Manual Control Panels I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 40 number satcj75@bsnl 365
23 Replacement of Push Button Switch for Start or Stop or Reset Replacement of Push Button Switch for Start/ Stop/Reset in existing Different capacity and make E/A Set AMF / Manual Control Panels I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 5 number satcj75@bsnl 365
24 Replacement of 12 V DC or 220 V AC HR Meter Counter Type Replacement of 12 V DC / 220 V AC HR Meter Counter Type in existing Different capacity and make E/A Set AMF / Manual Control Panels I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Note- Make and Model as per manufacturer recommendation ) 25 number satcj75@bsnl 365
25 Supply and Fixing of 12 volt battery operated self starter Supplying & fixing of 12 Volt Battery Operated Self Starter suitable for Starting of Engine i/c fixing the same on the DG set making connections testing etc. complete as reqd. ( Make- Autolek or Similar Superior Make) 8 number satcj75@bsnl 365
26 Supplying and fixing of 12 Volt Battery Charging Alternator Supplying & fixing of 12 Volt Battery Charging Alternator on the existing DG set i/c making connections testing etc. complete as reqd. ( Make -Autolek or Similar Superior Make) 4 number satcj75@bsnl 365
27 Repairing of 12 volt battery charging alternator Repairing and servicing of the 12 volt battery charging alternator for DG set i/c greasing, oiling, making connections testing etc. complete as reqd. 8 job satcj75@bsnl 365
28 Repairing and General Servicing of the existing faulty radiator up to 55 KVA Repairing & General Servicing of the existing faulty radiator up to 55 KVA Diesel Engine alternator set by repairing of leakage and cleaning of copper tubes with help of cleaning agents, dismentling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd. 8 job satcj75@bsnl 365
29 Pdg General servicing and Repairing of 12 Volts Engine Starting Self Pdg General servicing and Repairing of 12 Volts Engine Starting Self that I/c dismentalling of equipments, greasing and oiling of bearing and other parts , cleaning of self with petrol , replacement of Carbon Brush , Housing etc. complete checking of self and testing and fixing with proper alignment with gears etc complete as reqd. 12 job satcj75@bsnl 365
30 Dismentalling of existing Up to 20 KVA DEA sets Dismentalling of existing Up to 20 KVA DEA sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of TE / BTS site under ED Jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd. 25 job satcj75@bsnl 365
31 Dismentalling of existing More Than 20 KVA and Upto 55 KVA DEA Sets Dismentalling of existing More Than 20 KVA & Upto 55 KVA DEA Sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of TE / BTS site under ED Jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd. 24 job satcj75@bsnl 365
32 Extra for shifting of existing DEA set up to 20 KVA Extra for shifting of existing DEA set up to 20 KVA Capacity from Rooftop of the building to Ground Floor / Loading Vehicle with the help of Chain Pulley / Crane by ensuring safety to the existing construction at site and reparing of any damage during Shifting / Dismentling by making good the same etc. complete as reqd. 8 job satcj75@bsnl 365
33 Loading of existing Up to 20 KVA DEA sets Loading of existing Up to 20 KVA DEA sets from Ground Floor to Loading vehicle with the help of chain pulley / Crane / Man power etc. complete as reqd. 25 job satcj75@bsnl 365
34 Loading of existing More Than 20 KVA and Upto 55 KVA DEA Sets Loading of existing More Than 20 KVA & Upto 55 KVA DEA Sets from Ground Floor to Loading vehicle with the help of chain pulley / Crane / Man power etc. complete as reqd. 24 job satcj75@bsnl 365
35 Transportation of Up to 20 KVA DEA sets Transportation of Up to 20 KVA DEA sets along with all accessories etc from TE / BTS Site of SSA under ED Jaipur to Store / Any Place in same SSA as directed by Engg. in Charge by transport by truck / Loading Vehicle etc. complete as reqd. 35 job satcj75@bsnl 365
36 Transportation of More Than 20 KVA and Upto 55 KVA DEA Sets Transportation of More Than 20 KVA & Upto 55 KVA DEA Sets along with all accessories etc from TE / BTS Site of SSA under ED Jaipur to Store / Any Place in same SSA as directed by Engg. in Charge by transport by truck / Loading Vehicle etc. complete as reqd. 24 job satcj75@bsnl 365
37 Unloading Up to 20 KVA DEA sets Unloading of existing DEA sets of Up to 20 KVA DEA sets from Loading Vehicle to Place of Shifting / Store along with all accessories etc as directed by Engg. in Charge with the help of chain pulley / Crane / Man power etc. complete as reqd. 25 job satcj75@bsnl 365
38 Unloading More Than 20 KVA and Upto 55 KVA DEA Unloading of existing DEA sets of More Than 20 KVA & Upto 55 KVA DEA from Loading Vehicle to Place of Shifting / Store along with all accessories etc as directed by Engg. in Charge with the help of chain pulley / Crane / Man power etc. complete as reqd. 24 job satcj75@bsnl 365
39 ITC of Up to 20 KVA DEA sets on existing foundation Installation, Testing and Commissioning of existing DEA sets of Up to 20 KVA DEA sets on existing foundation / floor at site along with Canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at Site. 12 job satcj75@bsnl 365
40 ITC of More Than 20 KVA and Upto 55 KVA DEA Installation, Testing and Commissioning of existing DEA sets of More Than 20 KVA & Upto 55 KVA DEA on existing foundation / floor at site along with Canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at Site. 11 job satcj75@bsnl 365
41 Labour Charges for Top Overhauling of existing DEA Sets up to 20 KVA Labour Charges for Top Overhauling of existing DEA Sets up to 20 KVA Capacity i/c dismentalling of all parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safties, meters if reqd and calibration of engine as per manufaturer reccommendations. 9 job satcj75@bsnl 365
42 Replacement of the Liner assembly with rubber ring DEA sets up to 20 KVA Replacement of the Liner assembly with rubber ring in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts, testing etc as reqd. 26 number satcj75@bsnl 365
43 Replacement of the Piston Set without Piston Ring Set DEA sets up to 20 KVA Replacement of the Piston Set without Piston Ring Set in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 26 number satcj75@bsnl 365
44 Replacement of the Piston Ring Set DEA sets up to 20 KVA Replacement of thePiston Ring Set in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 26 number satcj75@bsnl 365
45 Replacement of the Set of Gasket including Head Gasket DEA sets up to 20 KVA Replacement of the Set of Gasket i/c Head Gasket in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 9 set satcj75@bsnl 365
46 Replacement of the O Ring Set DEA sets up to 20 KVA Replacement of the O Ring Set in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 17 set satcj75@bsnl 365
47 Replacement of the CR Bearing DEA sets up to 20 KVA Replacement of theCR Bearing in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 25 number satcj75@bsnl 365
48 Replacement of the Main Bearing DEA sets up to 20 KVA Replacement of the Main Bearing in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 11 number satcj75@bsnl 365
49 Replacement of the Oil Pressure Guage DEA sets up to 20 KVA Replacement of the Oil Pressure Guage in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 3 number satcj75@bsnl 365
50 Replacement of the Front oil Seal of Crank Shaft DEA sets up to 20 KVA Replacement of the Front oil Seal ( Crank Shaft ) in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 7 set satcj75@bsnl 365
51 Replacement of the Back oil Seal of Crank Shaft DEA sets up to 20 KVA Replacement of the Back oil Seal ( Crank Shaft ) in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 7 set satcj75@bsnl 365
52 Labour Charges for Top Overhauling of more than 20 KVA and upto 55 KVA Labour Charges for Top Overhauling of existing DEA Setsmore than 20 KVA and upto 55 KVA Capacity i/c dismentalling of all parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safties, meters if reqd and calibration of engine as per manufaturer reccommendations. 7 job satcj75@bsnl 365
53 Replacement of the Liner assembly with rubber ring DEA sets more than 20 KVA and upto 55 KVA Replacement of the Liner assembly with rubber ring in existing DEA sets more than 20 KVA & upto 55 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 28 number satcj75@bsnl 365
54 Replacement of the Piston Set without Piston Ring Set DEA sets more than 20 KVA and upto 55 KVA Replacement of the Piston Set without Piston Ring Set in existing DEA sets more than 20 KVA & upto 55 KVA of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 28 number satcj75@bsnl 365
55 Replacement of the Piston Ring Set DEA sets more than 20 KVA and upto 55 KVA Replacement of thePiston Ring Set in existing DEA sets more than 20 KVA & upto 55 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 28 number satcj75@bsnl 365
56 Replacement of the Set of Gasket and Head Gasket DEA sets more than 20 KVA and upto 55 KVA Replacement of the Set of Gasket i/c Head Gasket in existing DEA sets more than 20 KVA & upto 55 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 7 set satcj75@bsnl 365
57 Replacement of the O Ring Set DEA sets more than 20 KVA and upto 55 KVA Replacement of the O Ring Set in existing DEA sets more than 20 KVA & upto 55 KVACapacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 19 set satcj75@bsnl 365
58 Replacement of the CR Bearing DEA sets more than 20 KVA and upto 55 KVA Replacement of theCR Bearing in existing DEA sets more than 20 KVA & upto 55 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 25 number satcj75@bsnl 365
59 Replacement of the Main Bearing DEA setsmore than 20 KVA and upto 55 KVA Replacement of the Main Bearing in existing DEA sets more than 20 KVA & upto 55 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 7 number satcj75@bsnl 365
60 Replacement of the Oil Pressure Guage DEA sets more than 20 KVA and upto 55 KVA Replacement of the Oil Pressure Guage in existing DEA sets more than 20 KVA & upto 55 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 4 number satcj75@bsnl 365
61 Replacement of the Front oil Seal of Crank Shaft DEA sets more than 20 KVA and upto 55 KVA Replacement of the Front oil Seal ( Crank Shaft ) in existing DEA sets more than 20 KVA & upto 55 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 5 set satcj75@bsnl 365
62 Replacement of the Back oil Seal of Crank Shaft DEA sets more than 20 KVA and upto 55 KVA Replacement of the Back oil Seal ( Crank Shaft ) in existing DEA sets more than 20 KVA & upto 55 KVA Capacity of various Make and Model as per manufacturer recommendations I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 5 set satcj75@bsnl 365
63 Repairing of Cylinder Head Repairing of Cylinder Head ( One Job for Each Head ) with replacement of valve seat, Valve guide, Valves and stamp seal i/c grinding , lapping of valves I/c turning, grinding of head etc complete as reqd. 11 job satcj75@bsnl 365
64 Repairing of Up to 20 KVA DEA sets Crank Shaft Repairing of Up to 20 KVA DEA sets Crank Shaft i/c Grinding, lapping, bushing, allignement etc complete as reqd. 3 job satcj75@bsnl 365
65 Repairing of more than 20 KVA and upto 55 KVA DEA sets Crank Shaft Repairing of more than 20 KVA & upto 55 KVA DEA sets Crank Shaft i/c Grinding, lapping, bushing, allignement etc complete as reqd. 4 job satcj75@bsnl 365
66 Transportation Charges up to 50 Km for Alternator up to 55 KVA Transportation Charges up to 50 Km for Alternator of various capacity up to 55 KVA from Site to the nearest Workshop & back after repairing i/c Dismentling, loading, unloading, transportation, safe Handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the Alternator etc. complete as reqd. 4 job satcj75@bsnl 365
67 Transportation Charges More than 51 to 100 Km for Alternator up to 55 KVA Transportation Charges More than 51 to 100 Km for Alternator of various capacity up to 55 KVA from Site to the nearest Workshop & back after repairing i/c Dismentling, loading, unloading, transportation, safe Handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the Alternator etc. complete as reqd. 7 job satcj75@bsnl 365
68 Rewinding of Main Stator winding of Alternator up to 20 KVA Rewinding of Main Stator winding of Alternator Capacity up to 20 KVA of existing faulty Alternator of various Makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required. 8 job satcj75@bsnl 365
69 Rewinding of Main Rotor winding of Alternator up to 20 KVA Rewinding of Main Rotor winding of Alternator Capacity up to 20 KVA of existing faulty Alternator of various Makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required. 7 job satcj75@bsnl 365
70 Rewinding of Main Stator winding of Alternator more than 20 KVA and upto 55 KVA Rewinding of Main Stator winding of Alternator Capacity more than 20 KVA & upto 55 KVA of existing faulty Alternator of various Makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required. 4 job satcj75@bsnl 365
71 Rewinding of Main Rotor winding of Alternator more than 20 KVA and upto 55 KVA Rewinding of Main Rotor winding of Alternator Capacity more than 20 KVA & upto 55 KVA of existing faulty Alternator of various Makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required. 4 job satcj75@bsnl 365
72 Exciter Stator winding of Alternator up to 55 KVA Rewinding of Exciter Stator winding of Alternator Capacity up to 55 KVA of existing faulty Alternator of various Makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required. 6 job satcj75@bsnl 365
73 Exciter Rotor winding of Alternator up to 55 KVA Rewinding of Exciter Rotor winding of Alternator Capacity up to 55 KVA of existing faulty Alternator of various Makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required. 6 job satcj75@bsnl 365
74 Replacement or Repairing of AVR Replacement / Repairing of AVR Make National or S.S. for existing faulty Alteranator upto 55 KVA Capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd. 23 job satcj75@bsnl 365
75 Replacement or Repairing of Power Diode for Rotating Rectifier Assembly Replacement / Repairing of Power Diode for Rotating Rectifier Assembly for existing faulty Alteranator upto 55 KVA Capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd. 9 job satcj75@bsnl 365
76 Replacement or Repairing of Bearing Suitable for above 20 KVA Alternator Replacement / Repairing of Bearing Suitable for above 20 KVA Alternator for existing faulty Alteranator upto 55 KVA Capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd. 7 job satcj75@bsnl 365
77 Providing of 2 Core 16 Sqmm Providing of 2 Core 16 Sqmm PVC insulated and PVC sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to relevent IS-Specification complete as reqd. ( Note - Cable shall be provided at Site / Handed over to SSA Authority as per direction of Engg. in Charge ) 400 meter satcj75@bsnl 365
78 Providing of 4 Core 16 Sqmm Providing of 4 Core 16 Sqmm PVC insulated and PVC sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to relevent IS-Specification complete as reqd. ( Note - Cable shall be provided at Site / Handed over to SSA Authority as per direction of Engg. in Charge ) 900 meter satcj75@bsnl 365
79 Laying of one number Upto 35 sq. mm on wall surface Laying and fixing of one number Upto 35 sq. mm (clamped with 1mm thick saddle) PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. 550 meter satcj75@bsnl 365
80 Laying of one number Upto 35 sq. mm direct in ground Laying of one number Upto 35 sq. mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 125 meter satcj75@bsnl 365
81 Laying of one number Upto 35 sq. mmin the existing RCC or HUME or METAL pipe Laying of one number Upto 35 sq. mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 370 meter satcj75@bsnl 365
82 Supply and making end termination for 2 X 10 sq. mm 19 mm Supplying and making end termination with brass compression gland and aluminium lugs for 2 X 10 sq. mm (19 mm) for PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required. 20 set satcj75@bsnl 365
83 Supply and making end termination for 4 X 16 sq. mm 28 mm Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 16 sq. mm ( 28 mm) for PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required. 36 set satcj75@bsnl 365
84 Providing and fixing 6 SWG dia G.I. wire Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. 400 meter satcj75@bsnl 365
85 SITC of 32 amps four pole ON Load Side Handle operated change over switch SITC of 32 amps four pole ON Load Side Handle operated change over switch in steel enclosure capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd. 12 number satcj75@bsnl 365
86 SITC of 63 amps 2 Pole ON Load Side Handle operated change over switch SITC of 63 amps 2 Pole ON Load Side Handle operated change over switch in steel enclosure capable of working 240 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd. 12 number satcj75@bsnl 365
87 SITC of 63 amps four pole ON Load Side Handle operated change over switch SITC of 63 amps four pole ON Load Side Handle operated change over switch in steel enclosure capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd. 27 number satcj75@bsnl 365
88 Providing and Fixing 63 Amp TPN Disconnector Fuse Switch Unit Providing and Fixing 63 A TPN Disconnector Fuse Switch Unit in sheet steel enclosure a/w HRC fuses capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd. 12 number satcj75@bsnl 365

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Reverse Auction Schedule

Completed

Start

11-Sep-2025, 5:00 pm

End

13-Sep-2025, 10:00 am

Duration: 41 hours

Reverse Auction Document

✅ RA concluded. Check financial results for final rankings.

Reverse Auction Results Final Prices

These are the final prices after the reverse auction event. Prices may be lower than initial bids.

Rank Seller Final Price Item
L1H.N. ENGINEERING(MSE,MII)   Under PMA Winner ₹22,26,886Item Categories : Visit charges to attend fault of DEA Set,General Servicing of the Up to 20 KVA DEA sets,General Ser
L2MANOHAR ELECTRICALS (MSE,MII)   Under PMA₹22,33,486Item Categories : Visit charges to attend fault of DEA Set,General Servicing of the Up to 20 KVA DEA sets,General Ser

🎉 L1 Winner

H.N. ENGINEERING(MSE,MII)   Under PMA

Final Price: ₹22,26,886