TenderDekho Logo
GEM

Invitation to Bid - C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type in GHAZIABAD, UTTAR PRADESH

Bid Publish Date

02-Jan-2025, 9:38 am

Bid End Date

13-Jan-2025, 11:00 am

Latest Corrigendum Available

Progress

Issue02-Jan-2025, 9:38 am
Corrigendum17-Jan-2025
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

7857

Categories 87

Bharat Electronics Limited (bel) has released a public tender for C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type in GHAZIABAD, UTTAR PRADESH. Quantity: 7857. Submission Deadline: 13-01-2025 11: 00: 00. Download documents and apply online.

Documents 5

GeM-Bidding-7320007.pdf

Main Document

BOQ Document

BOQ

BOQ Document

BOQ

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

1.0 TR Capacity Hi Wall mounting 5-star rated Inverter Split AC,2.0 TR Capacity Cassette type 5-sta

State Bank Of India (sbi)

AIZAWL, MIZORAM

Posted: 12 December 2025
Closed: 2 January 2026
GEM

28 HP heat pump outdoor VRV OR VRF,26 HP heat pump outdoor VRV OR VRF,4 Way 3.0 Tr VRF Cassette Ind

State Bank Of India (sbi)

LUCKNOW, UTTAR PRADESH

Posted: 15 December 2025
Closed: 31 December 2025
GEM

PVC Reducer Socket,ONE WAY CASSETTE 1.5 TON,ONE WAY CASSETTE AC,SPLIT AC WALL MOUNT,COPPER PIPING,W

Canara Bank

MUMBAI, MAHARASHTRA

Posted: 20 December 2025
Closed: 30 December 2025
GEM

GEM Portal Security Equipment Tender Gangangar Rajasthan 2025 – 3 Years Experience, GST/EMD, ISI/BIS Standards

N/A

Sri Ganganagar, RAJASTHAN

Posted: 20 December 2025
Closed: 30 December 2025
GEM

State Bank of India Deoria SBI procurement: Hi-Wall Split AC 2.0/1.5/1.0 TR, Copper Piping, Stabiliser & Installation 2025

State Bank Of India (sbi)

DEORIA, UTTAR PRADESH

Posted: 18 December 2025
Closed: 29 December 2025
GEM

Bill of Quantities (BOQ) 61 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 C73340001918Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexureIII-A Supply of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexureIII-A 5 nos con5.bel.gzb 45
2 C73340001724 Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure III-A Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure III-A 5 nos con5.bel.gzb 45
3 C73340001821 Supply of Cassette AC four way capacity 4 TR rating Inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure III-A Supply of Cassette AC four way capacity 4 TR rating Inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure III-A 12 nos con5.bel.gzb 45
4 100000000001Supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4TR Cassette ACorSplit AC unit Refer annexureIII-A Supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4TR Cassette ACorSplit AC unit Refer annexureIII-A 550 rmt con5.bel.gzb 45
5 100000000002Providing flexible PVC Duct hose Covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte AC units refer aneexure III-A Providing flexible PVC Duct hose Covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte AC units refer aneexure III-A 200 rmt con5.bel.gzb 45
6 100000000003 ProvidingcPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureIII-A ProvidingcPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureIII-A 100 rmt con5.bel.gzb 45
7 100000000004 Providing cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexureIII-A Providing cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexureIII-A 120 rmt con5.bel.gzb 45
8 100000000005 Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter digital ammeter indication lamps refer annexureIII-A Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter digital ammeter indication lamps refer annexureIII-A 4 nos con5.bel.gzb 45
9 100000000006 Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 4 sqmm refer annexureIII-A Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 4 sqmm refer annexureIII-A 200 rmt con5.bel.gzb 45
10 100000000007 Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 6 sqmm refer annexureIII-A Supply of following size LT power cable with Copper conductor XLPEorPVC as directed by EIC 4 core - 6 sqmm refer annexureIII-A 200 rmt con5.bel.gzb 45
11 100000000008 Supply of following size LT power cable with Copper conductor laying of the same in by EIC 4core - 25 sqmm refer annexure-III-A Supply of following size LT power cable with Copper conductor laying of the same in by EIC 4core - 25 sqmm refer annexure-III-A 60 rmt con5.bel.gzb 45
12 100000000019Supply of following size LT power cable with Copper conductor as directed by EIC 4core - 16 sqmm refer annexure-III-A Supply of following size LT power cable with Copper conductor as directed by EIC 4core - 16 sqmm refer annexure-III-A 60 rmt con5.bel.gzb 45
13 100000000010 Supply of Copper cable of size 4core - 2point5 sqmm for communication Supply of Copper cable of size 4core - 2point5 sqmm for communication 500 rmt con5.bel.gzb 45
14 100000000011 Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness 120 rmt con5.bel.gzb 45
15 100000000012Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness 75 rmt con5.bel.gzb 45
16 100000000013Installation testing and commissioning of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotaryorscroll compressor aircooled refer annexure-III-B Installation testing and commissioning of Cassette AC four way capacity 2point5 TR minimum 3 star rating Inverter type rotaryorscroll compressor aircooled refer annexure-III-B 5 nos con5.bel.gzb 45
17 100000000014Installationtesting and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type refer annexure-III-B Installationtesting and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type refer annexure-III-B 5 nos con5.bel.gzb 45
18 100000000015 Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor units refer annexure-III-B Installation testing and commissioning of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor units refer annexure-III-B 12 nos con5.bel.gzb 45
19 100000000016 Erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-III-B Erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-III-B 550 rmt con5.bel.gzb 45
20 100000000017Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable refer annexure-III-B Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable refer annexure-III-B 200 rmt con5.bel.gzb 45
21 100000000018 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexure-III-B Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units refer annexure-III-B 100 rmt con5.bel.gzb 45
22 100000000019 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-III-B Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-III-B 120 rmt con5.bel.gzb 45
23 100000000020 Erection testing and commissioning of rain proof outdoor duty as per IP-66 Electrical control panel annexure-III-B Erection testing and commissioning of rain proof outdoor duty as per IP-66 Electrical control panel annexure-III-B 4 nos con5.bel.gzb 45
24 100000000021 Laying of following size LT power cable with Copper conductor XLPEPVC insulation PVC inner sheathed armoured extruded PVC oas directed by EIC 4 core - 4 sqmm refer annexure-III-B Laying of following size LT power cable with Copper conductor XLPEPVC insulation PVC inner sheathed armoured extruded PVC oas directed by EIC 4 core - 4 sqmm refer annexure-III-B 200 rmt con5.bel.gzb 45
25 100000000022 Laying of following size LT power cable with Copper conductor XLPEorPVC insulation as directed by EIC 4 core - 6 sqmm refer annexure-III-B Laying of following size LT power cable with Copper conductor XLPEorPVC insulation as directed by EIC 4 core - 6 sqmm refer annexure-III-B 200 rmt con5.bel.gzb 45
26 100000000023Laying of following size LT power cable with Copper conducto as directed by EIC 4 core - 25 sqmm refer annexure-III-B Laying of following size LT power cable with Copper conducto as directed by EIC 4 core - 25 sqmm refer annexure-III-B 60 rmt con5.bel.gzb 45
27 100000000024Laying of following size LT power cable with Copper conductor XLPEorPVCas directed by EIC 4 core - 16 sqmm refer annexure-III-B Laying of following size LT power cable with Copper conductor XLPEorPVCas directed by EIC 4 core - 16 sqmm refer annexure-III-B 60 rmt con5.bel.gzb 45
28 100000000025Laying of Copper cable of size 4 core - 2point5 sqmm for communication Laying of Copper cable of size 4 core - 2point5 sqmm for communication 500 rmt con5.bel.gzb 45
29 100000000026Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness 120 rmt con5.bel.gzb 45
30 100000000027Installing of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness Installing of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness 75 rmt con5.bel.gzb 45
31 100000000028Dismantling and shifting of existing Cassette AC 46 nos and VRV outdoor units of capacity 198 Hp refer annexure III-B Dismantling and shifting of existing Cassette AC 46 nos and VRV outdoor units of capacity 198 Hp refer annexure III-B 1 lot con5.bel.gzb 45
32 C73340100470Supply of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-Iv-A Supply of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-Iv-A 4 nos con5.bel.gzb 45
33 C73340001724Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-Iv-A Supply of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-Iv-A 3 nos con5.bel.gzb 45
34 C73340001821Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor refer annexure-Iv-A Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor refer annexure-Iv-A 21 nos con5.bel.gzb 45
35 100000000029Supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-Iv-A Supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2or2point5or3or4TR Cassette ACorSplit AC unit refer annexure-Iv-A 400 rmt con5.bel.gzb 45
36 100000000030Providing of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling cassttte AC units refer annexure-Iv-A Providing of flexible PVC Duct hose Covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling cassttte AC units refer annexure-Iv-A 100 rmt con5.bel.gzb 45
37 100000000031Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units to refer annexure-Iv-A Providing of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units to refer annexure-Iv-A 80 rmt con5.bel.gzb 45
38 100000000032Providingof cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units complete refer annexure-Iv-A Providingof cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor units complete refer annexure-Iv-A 80 rmt con5.bel.gzb 45
39 100000000033Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter refer annexure-Iv-A Supply of rain proof outdoor duty as per IP-66 Electrical control panel with incommer 4 pole MCCB 100 Amp digital voltmeter refer annexure-Iv-A 4 nos con5.bel.gzb 45
40 100000000034Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY cable confirming EIC 4 core - 4 sqmmrefer annexure-Iv-A Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY cable confirming EIC 4 core - 4 sqmmrefer annexure-Iv-A 175 rmt con5.bel.gzb 45
41 100000000035Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY as directed by EIC 4 core - 6 sqmm refer annexure-Iv-A Supply of following size LT power cable with Copper conductor XLPEorPVC insulation PVC inner sheathed 1point1KV grade 2XFY as directed by EIC 4 core - 6 sqmm refer annexure-Iv-A 175 rmt con5.bel.gzb 45
42 100000000036Supply of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFYirming as directed by EIC 4 core - 25 sqmm refer annexure-Iv-A Supply of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFYirming as directed by EIC 4 core - 25 sqmm refer annexure-Iv-A 60 rmt con5.bel.gzb 45
43 100000000037Supply of following size LT power cable with Copper conductor XLPEorPVC sheathed 1point1KV by EIC 4 core - 16 sqmm refer annexure-Iv-A Supply of following size LT power cable with Copper conductor XLPEorPVC sheathed 1point1KV by EIC 4 core - 16 sqmm refer annexure-Iv-A 60 rmt con5.bel.gzb 45
44 100000000038Supply of Copper cable of size 4 core - 2point5 sqmm for communication Supply of Copper cable of size 4 core - 2point5 sqmm for communication 450 rmt con5.bel.gzb 45
45 100000000039Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness 80 rmt con5.bel.gzb 45
46 100000000040Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness Supply of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness 25 rmt con5.bel.gzb 45
47 100000000041Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-Iv-B Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 3 star rating Inverter type rotary or scroll compressor refer annexure-Iv-B 4 nos con5.bel.gzb 45
48 100000000042Installation testing and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-Iv-B Installation testing and commissioning of Cassette AC four way capacity 3 TR minimum 3 star rating Inverter type rotary or scroll compressor aircooled condensing unit refer annexure-Iv-B 3 nos con5.bel.gzb 45
49 100000000043Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor and indoor unit refer annexure-Iv-B Supply of Cassette AC four way capacity 4 TR Inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil fan motor and indoor unit refer annexure-Iv-B 21 nos con5.bel.gzb 45
50 100000000044Installation testing and commissioning of suitable size refrigerant grade for 2or2.5or3or4TR Cassette ACorSplit AC unit for suction liquid refer annexure-Iv-B Installation testing and commissioning of suitable size refrigerant grade for 2or2.5or3or4TR Cassette ACorSplit AC unit for suction liquid refer annexure-Iv-B 400 rmt con5.bel.gzb 45
51 100000000045Laying of flexible PVC Duct hose Covering pipe of size 60 mm suitable for exposed refrigerant refer annexure-IV-B Laying of flexible PVC Duct hose Covering pipe of size 60 mm suitable for exposed refrigerant refer annexure-IV-B 100 rmt con5.bel.gzb 45
52 100000000046Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexurecIV-B Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure IV-B 80 rmt con5.bel.gzb 45
53 100000000047Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure IV-B Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure IV-B 80 rmt con5.bel.gzb 45
54 100000000048Installation testing and commissioning of rain proof outdoor duty as per IP-66 refer annexure-Iv-B Installation testing and commissioning of rain proof outdoor duty as per IP-66 refer annexure-Iv-B 4 nos con5.bel.gzb 45
55 100000000049Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV gradeEIC 4 core - 6 sqmm refer annexure-Iv-B Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV gradeEIC 4 core - 6 sqmm refer annexure-Iv-B 175 rmt con5.bel.gzb 45
56 100000000050Laying of following size LT power cable with Copper conductor XLPEorPVC 1point1KV grade by EIC 4 core - 4 sqmm refer annexure-Iv-B Laying of following size LT power cable with Copper conductor XLPEorPVC 1point1KV grade by EIC 4 core - 4 sqmm refer annexure-Iv-B 175 rmt con5.bel.gzb 45
57 100000000051Laying of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY cableas directed by EIC 4 core - 16 sqmm refer annexure-Iv-B Laying of following size LT power cable with Copper conductor XLPEorPVC insulation1point1KV grade 2XFY cableas directed by EIC 4 core - 16 sqmm refer annexure-Iv-B 60 rmt con5.bel.gzb 45
58 100000000052Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV grade as directed by EIC 4 core - 25 sqmm refer annexure-Iv-B Laying of following size LT power cable with Copper conductor XLPEorPVC insulation 1point1KV grade as directed by EIC 4 core - 25 sqmm refer annexure-Iv-B 60 rmt con5.bel.gzb 45
59 100000000053Laying of Copper cable of size 4 core - 2point5 sqmm for communication Laying of Copper cable of size 4 core - 2point5 sqmm for communication 450 rmt con5.bel.gzb 45
60 100000000054Laying of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness Laying of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness 80 rmt con5.bel.gzb 45
61 100000000055Laying of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness Laying of perforated Hot Dipped Galvanised Iron cable tray of size 300 mm width X 50 mm depth X 1point6 mm thickness 25 rmt con5.bel.gzb 45

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Corrigendum Updates

3 Updates
#1

Update

17-Jan-2025

Extended Deadline

20-Jan-2025, 12:00 pm

Opening Date

20-Jan-2025, 12:30 pm

#2

Update

09-Jan-2025
#3

Update

09-Jan-2025

Extended Deadline

17-Jan-2025, 11:00 am

Opening Date

17-Jan-2025, 11:30 am

Frequently Asked Questions

Key insights about UTTAR PRADESH tender market

## FAQs
What are the **eligibility requirements** for this tender?

The eligibility requirements include being a registered entity with all necessary licenses as per Indian law. Bidders must demonstrate experience in supplying similar products to ensure compliance and service quality.

What **certificates** are required to participate in this tender?

Participants need to submit certificates that validate compliance with quality standards as specified in the tender documents. These might include ISO certifications or specific IS compliance documents relevant to Cassette AC units.

How do I complete the **registration process** for this tender?

To complete the registration process, bidders must visit the E-procurement portal, create an account, and submit any necessary documents as required under the tender registration guidelines.

What are the **accepted document formats** for submissions?

Bidders must provide all submissions in PDF format or any other formats specified in the tender documentation to ensure they are accepted for consideration during the evaluation process.

What are the **technical specifications** mandated for the AC units?

The technical specifications mandate inverter technology with a minimum capacity of 2.5 TR, a 3-star minimum rating, and use of copper cooling coils. All specifications should refer to the detailed guidelines in the annexures provided.

What **quality standards** must be met by the products supplied?

The supplied products must comply with relevant IS standards and meet industry-specific quality assurances. A detailed list can be found in the referenced documents.

What are the **compliance requirements** for materials used?

Materials must adhere to specifications listed in the tender documents, including environmental standards and safety regulations as applicable in the defense sector.

What are the **testing criteria** for the devices supplied?

Devices may need to pass specific performance and safety tests as part of the procurement process, with the criteria outlined in the tender documentation.

What are the **Earnest Money Deposit (EMD)** details for bidders?

Bidders must furnish an Earnest Money Deposit (EMD) as specified within the tender to guarantee serious offers. The amount and payment method will be outlined clearly in the official documents.

What are the **performance security requirements**?

A performance security might be mandated to ensure compliance with the contractual terms post-award. This typically includes a bank guarantee or similar financial instrument as defined in the tender terms.

What are the **payment terms** outlined in the tender?

The payment terms generally include milestone payments contingent on delivery and satisfactory performance of the supplied goods. Specific terms will be detailed in the contractual agreements.

How will **price evaluation considerations** affect bid assessment?

Price evaluation considerations will closely examine the proposed financials ensuring bids are competitive while maintaining quality and compliance with technical specifications.

What are the **submission methods** for bids?

Bids must be submitted through the designated E-procurement portal, following all guidelines laid out within the tender documentation for a streamlined evaluation process.

What are the key **timelines and deadlines** for this tender?

Key timelines and deadlines for submissions will be indicated clearly in the tender documentation. Bidders must adhere strictly to these timelines to avoid disqualification.

What does the **evaluation and selection process** entail?

The evaluation and selection process will involve multiple stages, including technical evaluations where compliance will be assessed, followed by financial evaluations. Bidders must meet both criteria for successful selection.

How will **notification of results** be communicated?

Notifications of results will be communicated through the designated E-procurement portal, with further details typically provided in the notification documents.

What are the **benefits for Micro, Small, and Medium Enterprises (MSEs)** participating in this tender?

MSEs may enjoy benefits such as relaxed eligibility criteria, additional consideration during evaluations, and possible price and technical concessions aimed at promoting inclusivity in government procurement.

Are there specific **provisions for startups** within this tender?

Specific provisions allow startups to participate under relaxed requirements, ensuring opportunities for emerging businesses to engage with government procurement processes.

How does this tender comply with **'Make in India' policies**?

The tender supports the 'Make in India' policies by prioritizing products manufactured domestically, promoting local industries, and adhering to procurement rules that favor indigenous suppliers.

What are the local content and **procurement rules** applicable?

The tender must adhere to local content requirements that aim to ensure a minimum percentage of domestic input in all supplied goods, reflecting the governmental push for local manufacturing and procurement initiatives.

Similar Tenders

5 found

81231/E8 SPECIAL REPAIR FOR REPLACEMENT OF BER PACKAGE TYPE AC PLANT OF CAPACITY (3 X 5TR 02 NOs) AND CONNECTED ACCESSORIES WITH 3 X 16.5 TR CAPACITY PACKAGE TYPE AC PLANT AT AED COMPLEX, INS UTKROSH UNDER AGE E/M-I OF GE MINNIEBAY, SRI VIJAYA PURAM

E-IN-C BRANCH - MILITARY ENGINEER SERVICES

📍 SOUTH ANDAMANS, ANDAMAN AND NICOBAR ISLANDS

EMD: ₹1.3 L
Est: ₹69.2 L
⏰ Deadline: 4 weeks left
🛒 Type: Works
View EPROCURE

3 add 8 way 415 volt VTPN MCB distribution box,25 Amp 4 Pole rating and 16 ka breaking capacity and

Border Security Force (bsf)

⏰ Deadline: 4 weeks left
🛒 Type: Goods
View GEM

Split AC, 1.5 Ton 4750-5800 Kcal/hr, wall mount type, Inverter type, 5 star rating, qty-30 Nos.

Armoured Vehicles Nigam Limited

EMD: ₹33,000
⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Supply, installation, testing, commissioning of 4TR inverter type cassette AC

Centre For Development Of Advanced Computing (c-dac)

📍 THIRUVANANTHAPURAM, KERALA

⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Split Air Conditioner,Installation and Commissoining of for Split AC,Cassette type Air Conditioner,

⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM