Progress
Bharat Sanchar Nigam Limited Portal(bsnl) announces a tender for Supplying of 1. 5TR inverter type split AC unit as per BEE star rating 5star, Installation of 1. 5 TR split AC unit including fixing of indoor unit on wall outdoor on existing bracket, Supplying and fixing of readymade stand for Out door unit, Dismantling the existing 1. 5 TR split AC unit both indoor and outdoor, Supplying and fixing of additional refrigerant copper pipe beyond standard length, Supplying and fixing of 4core 2. 5sq. mm. Copper conductor cable, Supplying and fixing of 25mm PVC drain pipe, Supplying and Fixing of wall mountable stabilizer, Supplying and fixing of sequential cum thermostat AC Unit controller for 2Nos AC Units in DIMAPUR, NAGALAND. Quantity: 206. Submission Deadline: 26-10-2026 16: 00: 00. Last date to apply is approaching fast!
Quantity
206
Category
Supplying of 1.5TR inverter type split AC unit as per BEE star rating 5star
Bid Type
Two Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
4
OEM Avg. Turnover
37
Past Performance
80 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Supplying of 1.5TR inverter type split AC unit as per BEE star rating 5star , Installation of 1.5 TR split AC unit including fixing of indoor unit on wall outdoor on existing bracket , Supplying and fixing of readymade stand for Out door unit , Dismantling the existing 1.5 TR split AC unit both indoor and outdoor , Supplying and fixing of additional refrigerant copper pipe beyond standard length , Supplying and fixing of 4core 2.5sq.mm. Copper conductor cable , Supplying and fixing of 25mm PVC drain pipe , Supplying and Fixing of wall mountable stabilizer , Supplying and fixing of sequential cum thermostat AC Unit controller for 2Nos AC Units
Advisory Bank
State Bank of India
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
90
Delivery Locations
1
Delivery Cities
Peren
Delivery Pincodes
797112
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Kashi Yadaiah | 797112,O/o the GMTD BSNL Dimapur-797112 Nagaland | Peren | Nagaland | 797112 | 15 | 90 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Supplying of 1.5TR inverter type split AC unit as per BEE star rating 5star
Supplying of 1.5TR inverter type split AC unit as per BEE star rating with copper refrigerant piping operating on 230V 50Hz AC supply having nominal cooling capacity of 4500 Kcal per hr or 5200 W minimum room air flow of 700 cubic mtrper hr and minimum Indian Seasonal Energy Efficiency Ratio ISEER of 5.6 minimum 5 Star rated including standard lengths of copper refrigerant pipes with insulation pipe and PVC drain pipe and suitable size round PVC insulated pvc sheathed copper flexible control cable 3mtrs length for indoor and out door connection etc as per scope specifications including delivery at site etc as required
Installation of 1.5 TR split AC unit including fixing of indoor unit on wall outdoor on existing bracket
Installation of 1.5 TR split AC units including fixing of indoor unit on wall and fixing of outdoor on existing bracket or Floor minor civil work complete with laying and connection of copper refregerent pipes leak testing Electrical connections Testing Commissioning etc complete as required
Supplying and fixing of readymade stand for Out door unit
Supplying and fixing of readymade stand for Out door unit at required location as per the site condition including fixing with anchor bolts and making good etc as required
Dismantling the existing 1.5 TR split AC unit both indoor and outdoor
Dismantling the existing 1.5 TR split AC unit both indoor and outdoor unit with copper pipe and cable flexible pipe and its accessories including pumpdown of gas etc as required
Supplying and fixing of additional refrigerant copper pipe beyond standard length
Supplying and fixing of additional refrigerant copper pipe beyond standard length of refrigerant pipe supplied with unit of sizes 1/4 inch and 1/2 inch Liquid line and suction line with canifoam insulation cover for existing 1.5TR Split AC unit complete with etc as required
Supplying and fixing of 4core 2.5sq.mm. Copper conductor cable
Supplying and fixing of 4core 2.5sq.mm. Copper conductor PVC insulated round flexible cable including making connections etc As required
Supplying and fixing of 25mm PVC drain pipe
Supplying and fixing of 25mm PVC drain pipe along with suitable accessories such as Bends Elbows Tees etc on surface of wall including connections and making holes on wall partition to make passage of pipe and finishing opening etc as required
Supplying and Fixing of wall mountable stabilizer
Supplying and Fixing of wall mountable stabilizer suitable for 1.5Ton AC unit with Intelligent Time Delay System Low and High Voltage Cut Off Protection Latest Ic Technology suitable for operation on single phase AC supply etc as required
Supplying and fixing of sequential cum thermostat AC Unit controller for 2Nos AC Units
Supplying and fixing of sequential cum thermostat AC Unit controller for 2Nos 1.5TR Split AC Units including necessary interconnections between AC Units and timer unit testing and commissioning etc as required
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Supplying of 1.5TR inverter type split AC unit as per BEE star rating 5star | Supplying of 1.5TR inverter type split AC unit as per BEE star rating with copper refrigerant piping operating on 230V 50Hz AC supply having nominal cooling capacity of 4500 Kcal per hr or 5200 W minimum room air flow of 700 cubic mtrper hr and minimum Indian Seasonal Energy Efficiency Ratio ISEER of 5.6 minimum 5 Star rated including standard lengths of copper refrigerant pipes with insulation pipe and PVC drain pipe and suitable size round PVC insulated pvc sheathed copper flexible control cable 3mtrs length for indoor and out door connection etc as per scope specifications including delivery at site etc as required | 15 | nos | ee_e_ne2 | 90 | |
| 2 | Installation of 1.5 TR split AC unit including fixing of indoor unit on wall outdoor on existing bracket | Installation of 1.5 TR split AC units including fixing of indoor unit on wall and fixing of outdoor on existing bracket or Floor minor civil work complete with laying and connection of copper refregerent pipes leak testing Electrical connections Testing Commissioning etc complete as required | 15 | jobs | ee_e_ne2 | 90 | |
| 3 | Supplying and fixing of readymade stand for Out door unit | Supplying and fixing of readymade stand for Out door unit at required location as per the site condition including fixing with anchor bolts and making good etc as required | 15 | jobs | ee_e_ne2 | 90 | |
| 4 | Dismantling the existing 1.5 TR split AC unit both indoor and outdoor | Dismantling the existing 1.5 TR split AC unit both indoor and outdoor unit with copper pipe and cable flexible pipe and its accessories including pumpdown of gas etc as required | 10 | job | ee_e_ne2 | 90 | |
| 5 | Supplying and fixing of additional refrigerant copper pipe beyond standard length | Supplying and fixing of additional refrigerant copper pipe beyond standard length of refrigerant pipe supplied with unit of sizes 1/4 inch and 1/2 inch Liquid line and suction line with canifoam insulation cover for existing 1.5TR Split AC unit complete with etc as required | 45 | mtrs | ee_e_ne2 | 90 | |
| 6 | Supplying and fixing of 4core 2.5sq.mm. Copper conductor cable | Supplying and fixing of 4core 2.5sq.mm. Copper conductor PVC insulated round flexible cable including making connections etc As required | 45 | mtrs | ee_e_ne2 | 90 | |
| 7 | Supplying and fixing of 25mm PVC drain pipe | Supplying and fixing of 25mm PVC drain pipe along with suitable accessories such as Bends Elbows Tees etc on surface of wall including connections and making holes on wall partition to make passage of pipe and finishing opening etc as required | 40 | mtrs | ee_e_ne2 | 90 | |
| 8 | Supplying and Fixing of wall mountable stabilizer | Supplying and Fixing of wall mountable stabilizer suitable for 1.5Ton AC unit with Intelligent Time Delay System Low and High Voltage Cut Off Protection Latest Ic Technology suitable for operation on single phase AC supply etc as required | 15 | nos | ee_e_ne2 | 90 | |
| 9 | Supplying and fixing of sequential cum thermostat AC Unit controller for 2Nos AC Units | Supplying and fixing of sequential cum thermostat AC Unit controller for 2Nos 1.5TR Split AC Units including necessary interconnections between AC Units and timer unit testing and commissioning etc as required | 6 | nos | ee_e_ne2 | 90 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer