Bid Publish Date
11-Apr-2025, 6:54 pm
Bid End Date
21-Apr-2025, 7:00 pm
Location
Progress
Quantity
228
Damodar Valley Corporation announces a tender for MTPSSWAS1, MTPSSWAS2, MTPSSWAS3, MTPSSWAS4, MTPSSWAS5, MTPSSWAS6, MTPSSWAS7, MTPSSWAS8, MTPSSWAS9, MTPSSWAS10, MTPSSWAS11, MTPSSWAS12, MTPSSWAS13, MTPSSWAS14, MTPSSWAS15, MTPSSWAS16, MTPSSWAS17, MTPSSWAS18, MTPSSWAS19, MTPSSWAS20, MTPSSWAS21, MTPSSWAS22, MTPSSWAS23, MTPSSWAS24, MTPSSWAS25, MTPSSWAS26, MTPSSWAS27, MTPSSWAS28, MTPSSWAS29, MTPSSWAS30, MTPSSWAS31, MTPSSWAS32, MTPSSWAS33 in BANKURA, WEST BENGAL. Quantity: 228. Submission Deadline: 21-04-2025 19: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Item Category
MTPSSWAS1 , MTPSSWAS2 , MTPSSWAS3 , MTPSSWAS4 , MTPSSWAS5 , MTPSSWAS6 , MTPSSWAS7 , MTPSSWAS8 , MTPSSWAS9 , MTPSSWAS10 , MTPSSWAS11 , MTPSSWAS12 , MTPSSWAS13 , MTPSSWAS14 , MTPSSWAS15 , MTPSSWAS16 , MTPSSWAS17 , MTPSSWAS18 , MTPSSWAS19 , MTPSSWAS20 , MTPSSWAS21 , MTPSSWAS22 , MTPSSWAS23 , MTPSSWAS24 , MTPSSWAS25 , MTPSSWAS26 , MTPSSWAS27 , MTPSSWAS28 , MTPSSWAS29 , MTPSSWAS30 , MTPSSWAS31 , MTPSSWAS32 , MTPSSWAS33
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
MTPSSWAS1
Conductivity Transmitter (1056-03-20- 38-AN) for Conductivity Analyser, Make - Emerson
MTPSSWAS2
Specific Conductivity Sensor Model No.- 400-12 + 99CB100FT,Make - Emerson
MTPSSWAS3
Conductivity Sensor, Part no-400-11+99CB67FT, MAKE- ROSEMOUNT/EMERSON
MTPSSWAS4
Cation Column of SWAS System, Part no-CTN1
MTPSSWAS5
Dissolved Oxygen Membrane Kit (23502-04) for DO Analyser,Make-E merson
MTPSSWAS6
Dissolved Oxygen Sensor Fill Solution, 4 OZ, 120 ml (9210264) for DO Analyser
MTPSSWAS7
pH Sensor Model No.3900-01-10 + 99CB100FT make- M/s Emerson
MTPSSWAS8
pH Transmitter (1056-03-22- 38-AN) for pH Analyser,Make-Emerson
MTPSSWAS9
DISSOLVED OXYGEN SENSOR,Part no-499ATrDO-54-70 +99CB67FT, MAKE- ROSEMOUNT
MTPSSWAS10
Low Flow Cell, Process connection 1/4 OD tubing ( PN 24091-00) for DO analyser ,MATERIAL-SS,Make-Emerson
MTPSSWAS11
Variable pressure reducing element,Part No-VREL
MTPSSWAS12
Sample Cooler Model No.TLR 4225 Make- M/s Emerson
MTPSSWAS13
Back Pressure Regulator / Relief Valve for Sampling System,1/4 inch NPT(F), Viton diaphragm
MTPSSWAS14
Flow Indicator, Ref No. -FIW4 ( for branch sample in SWAS)
MTPSSWAS15
Flow Indicator without needle valve, Ref no. - FIW11 (main line)
MTPSSWAS16
Flow Indicator, Ref no. - FIW3
MTPSSWAS17
Sight Flow Indicator, Ref no-SFI2
MTPSSWAS18
Needle valve, Ref no. - NV11
MTPSSWAS19
Three Way Valve Model No. BV34N Make- M/s Emerson
MTPSSWAS20
Strainer Model No. STR10 Make- M/s Emerson
MTPSSWAS21
Isolation valve, Two way, Ref. no.- IV 31
MTPSSWAS22
NON RETURN VALVEINLET/O UTLET- 3/8inch NPT(F),Part No. NRV3
MTPSSWAS23
Relief Valve for Sampling System, Model - RV11 size-1/4inch NPT(F)
MTPSSWAS24
Relief Valve for Sampling System, Model - RV12, size-3/8inch NPT(F)
MTPSSWAS25
Relief Valve for Sampling System, Model - RV16, size-1/2inch NPT(F)
MTPSSWAS26
ISOLATION VALVE, TWO WAY (IBR APPROVED), Part No- IV51-IBR
MTPSSWAS27
Needle valve with drain, Ref no. - NVD1
MTPSSWAS28
QUICK CONNECTOR,Part no-QCI
MTPSSWAS29
DO Transmitter Model No.- 1056-03-25-38-AN Make- M/s Emerson
MTPSSWAS30
Sample Cooler for Sampling System ,Model - FLF 6225
MTPSSWAS31
Fine filter for Sox NOx analyser FFM1
MTPSSWAS32
Guard Filter for SOxNOx Analyser , Part No- FGD1, Make- Emerson
MTPSSWAS33
Sample cooler for Sox Nox Part np. CGR2
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | MTPSSWAS1 | Conductivity Transmitter (1056-03-20- 38-AN) for Conductivity Analyser, Make - Emerson | 3 | no | [email protected] | 140 | |
| 2 | MTPSSWAS2 | Specific Conductivity Sensor Model No.- 400-12 + 99CB100FT,Make - Emerson | 1 | no | [email protected] | 140 | |
| 3 | MTPSSWAS3 | Conductivity Sensor, Part no-400-11+99CB67FT, MAKE- ROSEMOUNT/EMERSON | 10 | no | [email protected] | 140 | |
| 4 | MTPSSWAS4 | Cation Column of SWAS System, Part no-CTN1 | 8 | no | [email protected] | 140 | |
| 5 | MTPSSWAS5 | Dissolved Oxygen Membrane Kit (23502-04) for DO Analyser,Make-E merson | 2 | set | [email protected] | 140 | |
| 6 | MTPSSWAS6 | Dissolved Oxygen Sensor Fill Solution, 4 OZ, 120 ml (9210264) for DO Analyser | 2 | no | [email protected] | 140 | |
| 7 | MTPSSWAS7 | pH Sensor Model No.3900-01-10 + 99CB100FT make- M/s Emerson | 22 | no | [email protected] | 140 | |
| 8 | MTPSSWAS8 | pH Transmitter (1056-03-22- 38-AN) for pH Analyser,Make-Emerson | 5 | no | [email protected] | 140 | |
| 9 | MTPSSWAS9 | DISSOLVED OXYGEN SENSOR,Part no-499ATrDO-54-70 +99CB67FT, MAKE- ROSEMOUNT | 1 | no | [email protected] | 140 | |
| 10 | MTPSSWAS10 | Low Flow Cell, Process connection 1/4 OD tubing ( PN 24091-00) for DO analyser ,MATERIAL-SS,Make-Emerson | 3 | no | [email protected] | 140 | |
| 11 | MTPSSWAS11 | Variable pressure reducing element,Part No-VREL | 3 | no | [email protected] | 140 | |
| 12 | MTPSSWAS12 | Sample Cooler Model No.TLR 4225 Make- M/s Emerson | 3 | no | [email protected] | 140 | |
| 13 | MTPSSWAS13 | Back Pressure Regulator / Relief Valve for Sampling System,1/4 inch NPT(F), Viton diaphragm | 6 | no | [email protected] | 140 | |
| 14 | MTPSSWAS14 | Flow Indicator, Ref No. -FIW4 ( for branch sample in SWAS) | 16 | no | [email protected] | 140 | |
| 15 | MTPSSWAS15 | Flow Indicator without needle valve, Ref no. - FIW11 (main line) | 8 | no | [email protected] | 140 | |
| 16 | MTPSSWAS16 | Flow Indicator, Ref no. - FIW3 | 13 | no | [email protected] | 140 | |
| 17 | MTPSSWAS17 | Sight Flow Indicator, Ref no-SFI2 | 7 | no | [email protected] | 140 | |
| 18 | MTPSSWAS18 | Needle valve, Ref no. - NV11 | 9 | no | [email protected] | 140 | |
| 19 | MTPSSWAS19 | Three Way Valve Model No. BV34N Make- M/s Emerson | 7 | no | [email protected] | 140 | |
| 20 | MTPSSWAS20 | Strainer Model No. STR10 Make- M/s Emerson | 24 | no | [email protected] | 140 | |
| 21 | MTPSSWAS21 | Isolation valve, Two way, Ref. no.- IV 31 | 8 | no | [email protected] | 140 | |
| 22 | MTPSSWAS22 | NON RETURN VALVEINLET/O UTLET- 3/8inch NPT(F),Part No. NRV3 | 8 | no | [email protected] | 140 | |
| 23 | MTPSSWAS23 | Relief Valve for Sampling System, Model - RV11 size-1/4inch NPT(F) | 8 | no | [email protected] | 140 | |
| 24 | MTPSSWAS24 | Relief Valve for Sampling System, Model - RV12, size-3/8inch NPT(F) | 5 | no | [email protected] | 140 | |
| 25 | MTPSSWAS25 | Relief Valve for Sampling System, Model - RV16, size-1/2inch NPT(F) | 4 | no | [email protected] | 140 | |
| 26 | MTPSSWAS26 | ISOLATION VALVE, TWO WAY (IBR APPROVED), Part No- IV51-IBR | 14 | no | [email protected] | 140 | |
| 27 | MTPSSWAS27 | Needle valve with drain, Ref no. - NVD1 | 14 | no | [email protected] | 140 | |
| 28 | MTPSSWAS28 | QUICK CONNECTOR,Part no-QCI | 5 | no | [email protected] | 140 | |
| 29 | MTPSSWAS29 | DO Transmitter Model No.- 1056-03-25-38-AN Make- M/s Emerson | 1 | no | [email protected] | 140 | |
| 30 | MTPSSWAS30 | Sample Cooler for Sampling System ,Model - FLF 6225 | 3 | no | [email protected] | 140 | |
| 31 | MTPSSWAS31 | Fine filter for Sox NOx analyser FFM1 | 2 | no | [email protected] | 140 | |
| 32 | MTPSSWAS32 | Guard Filter for SOxNOx Analyser , Part No- FGD1, Make- Emerson | 2 | no | [email protected] | 140 | |
| 33 | MTPSSWAS33 | Sample cooler for Sox Nox Part np. CGR2 | 1 | no | [email protected] | 140 |
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | TORQUE LABS ENGINEERING Under PMA | - | 21-04-2025 13:24:40 |
Please sign in or create an account to view contract details and download result documents.
Key insights about WEST BENGAL tender market
The eligibility requirements include being a registered entity that complies with relevant industry standards. Furthermore, bidders must demonstrate prior experience in supplying similar spare parts or systems, while adhering to local regulatory guidelines.
Bidders must include all necessary certificates such as a valid business license, technical specifications, and any relevant quality certifications that affirm compliance with industry standards. This documentation is crucial for the evaluation process.
To register for the submission of tenders, potential bidders should visit the official government procurement portal and complete the required registration form. Ensure that all necessary documentation is attached to facilitate a seamless registration process.
For a successful submission, bidders are required to provide documentation in commonly accepted formats, such as PDF and Word documents. It is essential that all files are clear and legible to ensure proper evaluation.
The evaluation process is conducted through a systematic examination of the submitted proposals, focusing on technical compliance, cost-effectiveness, and the bidders' previous performances. Each proposal is scored based on the established criteria, ensuring transparency and fairness in the selection of the winning bidder.
Sign up now to access all documents
Main Document
BOQ
BOQ
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS