Supply of 4 TR vertical split type air conditioner of floor mounting,Supply of 2 TR Split DC Invert
Airports Authority Of India
Menu
Progress
Quantity
431
Category
Supply and fixing heavy duty copper pipe 12mm or 1 oblique 2 inch dia bore thickness not less than 0 point 70mm complete incl brazing welding nuts bolts and screws of required size complete
Bid Type
Two Packet Bid
Indian Army has released a public tender for Supply install testing and commissioning of Tower AC of cap 2TR Cap moisture removal 2 point 2 ltr per hr min air flow 630 CFM 230V 50Hz single phase Make LG Blue Star Hitachi Voltas Iyod equivalent, Supply and fixing heavy duty copper pipe 12mm or 1 oblique 2 inch dia bore thickness not less than 0 point 70mm complete incl brazing welding nuts bolts and screws of required size complete, Supply and fixing heavy duty copper pipe 6mm or 1 oblique 4 inch dia bore thickness not less than 0 point 70mm complete incl brazing welding nuts bolts and screws of required size complete, Supply and fixing new nityrile rubber insulation for copper pipe suitable dor split AC of capacity from 1 point 5 to 2 TR complete all as directed by engr in charge, Supply and fixing ceiling fans complete with blades down rods elect regulator and accessories 230V 1200mm sweep Min fan speed 370 RPM Make Crompton Orient Anchor or equivalent, Supply and fixing exhaust fan steel body AC single phase 230V size 300mm sweep with blades and frames and louvers Make Compton Orient Anchor or equivalent, S and F sheet metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB of 20 amp capacity complete all as specified and directed by Engr in charge, S and F for wiring from indoor to outdoor unit size 2 point 5Sqmm PVC insulated multistranded FRLS four core round cable incl fixing of thimbless for split type AC 1 point 5 or 2TR, M and L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6Sqmm 1100V grade incl 6Sqmm PVC insulated multi stranded, Supply fixing new PVC drain pipe 15mm dia with coupler joint for Split or Window AC complete all as specified and as directed, Providing and making one number hole of upto 20 inch length 2 diameter in existing wall or slab RCC bricks stone by means of core cutting machine incl proper fixing of machine, Supply and fixing weather protection cover for outdoor AC unit heavy gauge min 0 point 5mm GI sheet with antirust coating sloping triangular top front both sides covered supported on MS pipe, Supply and fixing outdoor unit stand for 1 point 5TR or 2TR type AC complete all as specified and as directed in JAISALMER, RAJASTHAN. Quantity: 431. Submission Deadline: 22-12-2025 15: 00: 00. Download documents and apply online.
Airports Authority Of India
Indian Army
VISAKHAPATNAM, ANDHRA PRADESH
All India Institute Of Speech And Hearing (aiish) Mysore
Indian Army
BARDHAMAN, WEST BENGAL
Prasar Bharati Broadcasting Corporation Of India
CENTRAL DELHI, DELHI
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Supply install testing and commissioning of Tower AC of cap 2TR Cap moisture removal 2 point 2 ltr per hr min air flow 630 CFM 230V 50Hz single phase Make LG Blue Star Hitachi Voltas Iyod equivalent | Supply install testing and commissioning of Tower AC of cap 2TR Cap moisture removal 2 point 2 ltr per hr min air flow 630 CFM 230V 50Hz single phase Make LG Blue Star Hitachi Voltas Iyod equivalent | 4 | each job | agebr_geafjsm | 30 |
| 2 | Supply and fixing heavy duty copper pipe 12mm or 1 oblique 2 inch dia bore thickness not less than 0 point 70mm complete incl brazing welding nuts bolts and screws of required size complete | Supply and fixing heavy duty copper pipe 12mm or 1 oblique 2 inch dia bore thickness not less than 0 point 70mm complete incl brazing welding nuts bolts and screws of required size complete | 12 | rm | agebr_geafjsm | 30 |
| 3 | Supply and fixing heavy duty copper pipe 6mm or 1 oblique 4 inch dia bore thickness not less than 0 point 70mm complete incl brazing welding nuts bolts and screws of required size complete | Supply and fixing heavy duty copper pipe 6mm or 1 oblique 4 inch dia bore thickness not less than 0 point 70mm complete incl brazing welding nuts bolts and screws of required size complete | 12 | rm | agebr_geafjsm | 30 |
| 4 | Supply and fixing new nityrile rubber insulation for copper pipe suitable dor split AC of capacity from 1 point 5 to 2 TR complete all as directed by engr in charge | Supply and fixing new nityrile rubber insulation for copper pipe suitable dor split AC of capacity from 1 point 5 to 2 TR complete all as directed by engr in charge | 24 | rm | agebr_geafjsm | 30 |
| 5 | Supply and fixing ceiling fans complete with blades down rods elect regulator and accessories 230V 1200mm sweep Min fan speed 370 RPM Make Crompton Orient Anchor or equivalent | Supply and fixing ceiling fans complete with blades down rods elect regulator and accessories 230V 1200mm sweep Min fan speed 370 RPM Make Crompton Orient Anchor or equivalent | 210 | each | agebr_geafjsm | 30 |
| 6 | Supply and fixing exhaust fan steel body AC single phase 230V size 300mm sweep with blades and frames and louvers Make Compton Orient Anchor or equivalent | Supply and fixing exhaust fan steel body AC single phase 230V size 300mm sweep with blades and frames and louvers Make Compton Orient Anchor or equivalent | 9 | each | agebr_geafjsm | 30 |
| 7 | S and F sheet metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB of 20 amp capacity complete all as specified and directed by Engr in charge | S and F sheet metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB of 20 amp capacity complete all as specified and directed by Engr in charge | 4 | each | agebr_geafjsm | 30 |
| 8 | S and F for wiring from indoor to outdoor unit size 2 point 5Sqmm PVC insulated multistranded FRLS four core round cable incl fixing of thimbless for split type AC 1 point 5 or 2TR | S and F for wiring from indoor to outdoor unit size 2 point 5Sqmm PVC insulated multistranded FRLS four core round cable incl fixing of thimbless for split type AC 1 point 5 or 2TR | 20 | rm | agebr_geafjsm | 30 |
| 9 | M and L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6Sqmm 1100V grade incl 6Sqmm PVC insulated multi stranded | M and L for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6Sqmm 1100V grade incl 6Sqmm PVC insulated multi stranded | 76 | rm | agebr_geafjsm | 30 |
| 10 | Supply fixing new PVC drain pipe 15mm dia with coupler joint for Split or Window AC complete all as specified and as directed | Supply fixing new PVC drain pipe 15mm dia with coupler joint for Split or Window AC complete all as specified and as directed | 48 | rm | agebr_geafjsm | 30 |
| 11 | Providing and making one number hole of upto 20 inch length 2 diameter in existing wall or slab RCC bricks stone by means of core cutting machine incl proper fixing of machine | Providing and making one number hole of upto 20 inch length 2 diameter in existing wall or slab RCC bricks stone by means of core cutting machine incl proper fixing of machine | 4 | each | agebr_geafjsm | 30 |
| 12 | Supply and fixing weather protection cover for outdoor AC unit heavy gauge min 0 point 5mm GI sheet with antirust coating sloping triangular top front both sides covered supported on MS pipe | Supply and fixing weather protection cover for outdoor AC unit heavy gauge min 0 point 5mm GI sheet with antirust coating sloping triangular top front both sides covered supported on MS pipe | 4 | each | agebr_geafjsm | 30 |
| 13 | Supply and fixing outdoor unit stand for 1 point 5TR or 2TR type AC complete all as specified and as directed | Supply and fixing outdoor unit stand for 1 point 5TR or 2TR type AC complete all as specified and as directed | 4 | each | agebr_geafjsm | 30 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Choose from flexible plans to access tender documents instantly
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS