Open Tender for Automated HPLC System for Separation of complex mixtures in SRINAGAR, JAMMU & KASHMIR

Bid Publish Date

21-Jul-2026, 11:50 am

Bid End Date

20-Aug-2026, 7:00 pm

EMD

₹1,00,000

Generate Docs

Progress

Issue21-Jul-2026, 11:50 am
Corrigendum13-Aug-2026
AwardPending

A tender has been published for University Of Kashmir Automated HPLC System for Separation of complex mixtures (Q3) in SRINAGAR, JAMMU & KASHMIR. Quantity: 1 by. Submission Deadline: 20-08-2026 19: 00: 00. Check eligibility and apply.

Authority & Contact

Office Name

University Of Kashmir Hazratbal Srinagar

Grievance Contact

[email protected]

Tender Data

Bid Details

Quantity

1

Bid Type

Two Packet Bid

Bid Validity

90 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

RA Qualification Rule

H1-Highest Priced Bid Elimination

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

Yes

MII Purchase Preference

No

MSE Purchase Preference

No

Startup Exemption/Relaxation

No

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

10

OEM Avg. Turnover

20

Past Performance

50 %

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Automated HPLC System for Separation of complex mixtures (Q3)

Advisory Bank

HDFC Bank

Payment Timelines

Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)

Delivery Details

Max Delivery Days

45

Delivery Locations

1

Delivery Cities

Srinagar

Delivery Pincodes

190006

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Gulzar Ahmad Bhat190006,University of Kashmir,Hazratbal,SrinagarSrinagarJammu And Kashmir190006145-

Authority Records

HIGHER EDUCATION DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9637153.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Categories 14

Corrigendum Updates

1 Update
#1

Update

13-Aug-2026

Extended Deadline

18-Aug-2026, 12:30 pm

Opening Date

18-Aug-2026, 1:00 pm

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Standard parameter Instrument calibration standards IEC 17025, NA
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Components of unit Quaternary Low-Pressure Gradient pump& Parallel Double Plunger, Quaternary Low Pressure Gradient pump & Serial Double Plunger
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Number of solvents delivery 4
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Flow rate setting range in ml/min 0.001 to 10
Quaternary Gradient Solvent Delivery Unit with Degassing Unit Flow rate accuracy ± 1 %, ± 0.1%, ± 1 % or better
UV-Vis Detector UV-Vis Detector provided Yes, No Or higher
UV-Vis Detector Light source Deuterium lamp, NA if not provided, Tungsten Lamp
UV-Vis Detector Spectrum Band width in nm 4, 5, 6, 8, NA if not provided
UV-Vis Detector Wavelength range in nm 190 - 700, NA if not provided
UV-Vis Detector Sampling Rate in Hz 80, 90, 100, NA if not provided
UV-Vis Detector The flow cell must be temperature Controlled Yes, NA if not provided
UV-Vis Detector Wavelength accuracy in nm ± 1, NA if not provided
UV-Vis Detector Wavelength reproducibility in nm ± 0.1, NA if not provided
UV-Vis Detector Drift in AU/Hour less than 1 x 10-4, NA if not provided
UV-Vis Detector Noise level in AU ± 2.5 x 10-6, NA if not provided, ±5 x 10-6
UV-Vis Detector Ability to monitor and quantitative 2 wavelengths simultaneously Yes, NA if not provided
UV-Vis Detector Linearity in AU 2.5 or more, NA if not provided
UV-Vis Detector Temperature control provided for Flow cell Yes, NA if not provided
UV-Vis Detector Temperature control range for flow cell in Degree Celsius 5 degree above room temp to 50 degree, NA if not provided
UV-Vis Detector flow cell path length in mm 10, NA if not provided
UV-Vis Detector Flow cell volume in ?l 10 - 15, NA if not provided, 16 - 20
Auto Sample Injector with cooler Injection Method Total volume sample injection
Auto Sample Injector with cooler Carry over of sample 0.005% or lower, 0.025% or lower
Auto Sample Injector with cooler Injection precision in RSD less than 0.20 % RSD, less than 0.50 % RSD
Software Operating Windows Win 7 or latest, Win 10 or latest
Photo Diode Array (PDA) Detector Provision of Photo diode array Yes, No Or higher
Photo Diode Array (PDA) Detector PDA detector Wavelength range in nm 190- 800 or better, NA if not provided
Photo Diode Array (PDA) Detector Number of Diodes 512, 1024, NA if not provided
Photo Diode Array (PDA) Detector PDA detector light source Deuterium lamp and Tungsten lamp, NA if not provided, Deuterium lamp, Tungsten Lamp
Photo Diode Array (PDA) Detector PDA detector Wavelength accuracy in nm ± 1, NA if not provided
Photo Diode Array (PDA) Detector Data Rate in Hz 100, NA if not provided, <100
Photo Diode Array (PDA) Detector Noise in AU less than ± 0.6 x 10-5 or lower, NA if not provided, less than ± 1 x 10-5 or lower
Photo Diode Array (PDA) Detector PDA detector Drift in AU/Hour less than 1 x 10-4, NA if not provided, less than 1 x 10-3
Photo Diode Array (PDA) Detector Temperature controlled flow cell in C 5 degree above room temp to 50 degree, NA if not provided
Photo Diode Array (PDA) Detector Flow cell Flow cell, NA if not provided
Warranty & Reports Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 2, 3, 4, 5, 1 Or higher
Warranty & Reports Number of installations in Central /State/PSU Govt Hospitals 0, <3, >3
Warranty & Reports Availability of toll free facility for technical support maintained by OEM or authorized agencies Yes, No Or higher