Progress
Quantity
709
Category
Transportation of the existing fitted old dissmantled package A.C. units
Bid Type
Two Packet Bid
Bharat Sanchar Nigam Limited Portal(bsnl) has released a public tender for GSS sheet metal ducting, Double Layer canvas connection, Supply Air Grills with aluminium volume control damper, aluminum conductor armoured cable, copper conductor armoured cable, Plumbing work for drainage requirement, Powder coating M. S. cable trays, wall opening, Dismantling and removing the existing laid old power or control cables, Dismantling or removing the existing fitted old package A. C. units, Recovering the existing laid refrigerant piping of old Hot gas and cold gas, Dismantling the existing fitted old MS racks, Dismantling or removing the old condensate drain piping, Dismantling the existing old ducts of package units, Dismentalling of LT Panel from AC Plant room, Transportation of the existing fitted old dissmantled package A. C. units, ITC of 7TR HPAC Package, Supplying and Charging of the Refrigerant Gas, copper referigerant piping, Laying of recovered copper referigerant piping, Providing MS structure, ITC of following old recovered items, Providing and fixing 25 mm X 5 mm G. I. strip, 06 mm thick rubber matting, Liquid line filter drier, Installation Testing Commissioning of existing Electrical LT Panel, end termination with brass compression gland and aluminium lugs, Aluminium Conductor Power Cable of 1. 1 KV Grade in JAIPUR, RAJASTHAN. Quantity: 709. Submission Deadline: 08-07-2025 15: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
GSS sheet metal ducting , Double Layer canvas connection , Supply Air Grills with aluminium volume control damper , aluminum conductor armoured cable , copper conductor armoured cable , Plumbing work for drainage requirement , Powder coating M.S. cable trays , wall opening , Dismantling and removing the existing laid old power or control cables , Dismantling or removing the existing fitted old package A.C. units , Recovering the existing laid refrigerant piping of old Hot gas and cold gas , Dismantling the existing fitted old MS racks , Dismantling or removing the old condensate drain piping , Dismantling the existing old ducts of package units , Dismentalling of LT Panel from AC Plant room , Transportation of the existing fitted old dissmantled package A.C. units , ITC of 7TR HPAC Package , Supplying and Charging of the Refrigerant Gas , copper referigerant piping , Laying of recovered copper referigerant piping , Providing MS structure , ITC of following old recovered items , Providing and fixing 25 mm X 5 mm G.I. strip , 06 mm thick rubber matting , Liquid line filter drier , Installation Testing Commissioning of existing Electrical LT Panel , end termination with brass compression gland and aluminium lugs , Aluminium Conductor Power Cable of 1.1 KV Grade
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
GSS sheet metal ducting
Supplying, installing, balancing and commissioning of fabricated at site GSS sheet metal rectangular or round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, support as per approved drawing and specifications of following sheet (a) Thickness 0.80 mm sheet
Double Layer canvas connection
Providing, Making & Fixing of flexible Double Layer canvas connection complete as required.
Supply Air Grills with aluminium volume control damper
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
aluminum conductor armoured cable
SITC of PVC insulated PVC sheathed aluminum conductor armoured cable of following sizes on the existing MS tray or walls with saddles or PVC of cables with glands etc. as required (a) 4 x 10 Sqmm
copper conductor armoured cable
SITC of following PVC insulated PVC sheathed copper conductor armoured cable for control wiring on the existing MS tray / walls with saddles/PVC thread/cable tie, screws etc. I/c end termination of cables with glands etc as required. (a) 4 x 1.5 sqmm
Plumbing work for drainage requirement
SITC of Plumbing work for drainage requirement with following size pipes including reducer, elbows, tees, unions, bends, sockets, flanges etc. for making water line connection for various package Units of system etc. complete as required. (a) 40 mm UPVC Pipe
Plumbing work for drainage requirement
SITC of Plumbing work for drainage requirement with following size pipes including reducer, elbows, tees, unions, bends, sockets, flanges etc. for making water line connection for various package Units of system etc. complete as required. (b) 20 mm UPVC Pipe
Powder coating M.S. cable trays
Supplying and installing following size of perforated painted with Powder coating M.S. cable trays in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (a) 100 mm width x 50 mm x 1.6 mm thickness
Powder coating M.S. cable trays
Supplying and installing following size of perforated painted with Powder coating M.S. cable trays in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (b) 150 mm width x 50 mm x 1.6 mm thickness
wall opening
Pdg. Making wall opening to increase the return air area complete including with finishing the same and shifting the debris or malba etc. to ground floor as directed by E-IN-C
Dismantling and removing the existing laid old power or control cables
Dismantling and removing the existing laid old power or control cables of condenser fans, old package units, condenser units etc. complete by unscrewing or cutting from the related M.S. racks or tray as required, unloading the same from different floors to ground floor and shifting the same to the place inside the exchange premises
Dismantling or removing the existing fitted old package A.C. units
Dismantling or removing the existing fitted old package A.C. units with related condensers and accessories like canvas, damper and unloading the same from different floors and terrace to ground floor along with shifting the same to the place inside the exchange premises.
Recovering the existing laid refrigerant piping of old Hot gas and cold gas
Recovering the existing laid refrigerant piping of old Hot gas and cold gas of different sizes from different floors to ground floor and shifting the same to the place inside the exchange premises
Dismantling the existing fitted old MS racks
Dismantling the existing fitted old MS racks of cables or gas line pipes viz angle , square pipe, bar, hangers etc. along with shifting the same from different floors to ground floor
Dismantling or removing the old condensate drain piping
Dismantling or removing the existing laid old condensate drain piping, unloading the same from different floors to ground floor including shifting the same to place inside the exchange premise
Dismantling the existing old ducts of package units
Dismantling the existing old ducts of package units along with fine filters and plenum complete by unscrewing, opening the flanges, supports,hangers
Dismentalling of LT Panel from AC Plant room
Dismentalling of LT Panel from AC Plant room having 02 incommers and 06 outgoings under BA Jaipur including disconnection of all cable end terminations , loading , unloading and shifting the same to Tax Bldg., M.I.Road, Jaipur
Transportation of the existing fitted old dissmantled package A.C. units
Transportation of the existing fitted old dissmantled package A.C. units with related condensers & accessories like Cu-piping,Cu- cable, damper, ducts, Trays, LT panel etc under BA Jaipur. Approx Distance upto 100Km and shifting the same to Tax Bldg., M.I.Road, Jaipur
ITC of 7TR HPAC Package
Installation, testing and commissioning of above 7TR HPAC Package indoor and outdoor units on existing frame, pressure testing iincluding performance testing
Supplying and Charging of the Refrigerant Gas
Supplying and Charging of the Refrigerant Gas R-407 C or R-410 A or same as per Originally supplied with PKG Units including Pressure testing
copper referigerant piping
Supply and fixing of the following sizes 18 gauge copper referigerant piping on the MS perforated tray (a) size 1-1/8 single run
copper referigerant piping
Supply and fixing of the following sizes 18 gauge copper referigerant piping on the MS perforated tray (b) size 7/8 single run
Laying of recovered copper referigerant piping
Laying of following sizes of existing recovered copper referigerant piping on the MS perforated tray (a) size 1-1/8 single run
Laying of recovered copper referigerant piping
Laying of following sizes of existing recovered copper referigerant piping on the MS perforated tray (b) size 7/8 single run
Providing MS structure
Providing MS structure for outdoor or Indoor units made out of solid channels , angles, flat
ITC of following old recovered items
(a) 100 mm width x 50 mm x 1.6 mm thickness
ITC of following old recovered items
(b) 150 mm width x 50 mm x 1.6 mm thickness
ITC of following old recovered items
(c) 4 x 1.5 sqmm Cable
ITC of following old recovered items
(d) 4 x 10 sqmm Cable
ITC of following old recovered items
(e) Existing Duct or Fire dampers in supply air main ducts or branch ducts
ITC of following old recovered items
(f) 25 mm x 5 mm thick G.I. strip for loop earthing on cable tray or wall
Providing and fixing 25 mm X 5 mm G.I. strip
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections
06 mm thick rubber matting
SITC of 06 mm thick ISI marked rubber matting
Liquid line filter drier
Supply and Fixing the Liquid line filter drier suitable for R 407C or R410A Refrigerant Make Danfoss
Installation Testing Commissioning of existing Electrical LT Panel
Installation Testing Commissioning of above existing Electrical LT Panel including connection of cables
end termination with brass compression gland and aluminium lugs
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3.5 X 70 sqmm
Aluminium Conductor Power Cable of 1.1 KV Grade
Supplying and Laying or fixing of Aluminium Conductor Power Cable of 1.1 KV Grade of following size on wall surface or trench or on tray (a) 3.5 X 70 sq. mm
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | GSS sheet metal ducting | Supplying, installing, balancing and commissioning of fabricated at site GSS sheet metal rectangular or round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, support as per approved drawing and specifications of following sheet (a) Thickness 0.80 mm sheet | 25 | sq mtr | satcj75@bsnl | 30 | |
| 2 | Double Layer canvas connection | Providing, Making & Fixing of flexible Double Layer canvas connection complete as required. | 3 | job | satcj75@bsnl | 30 | |
| 3 | Supply Air Grills with aluminium volume control damper | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. | 1 | sq mtr | satcj75@bsnl | 30 | |
| 4 | aluminum conductor armoured cable | SITC of PVC insulated PVC sheathed aluminum conductor armoured cable of following sizes on the existing MS tray or walls with saddles or PVC of cables with glands etc. as required (a) 4 x 10 Sqmm | 18 | meter | satcj75@bsnl | 30 | |
| 5 | copper conductor armoured cable | SITC of following PVC insulated PVC sheathed copper conductor armoured cable for control wiring on the existing MS tray / walls with saddles/PVC thread/cable tie, screws etc. I/c end termination of cables with glands etc as required. (a) 4 x 1.5 sqmm | 20 | meter | satcj75@bsnl | 30 | |
| 6 | Plumbing work for drainage requirement | SITC of Plumbing work for drainage requirement with following size pipes including reducer, elbows, tees, unions, bends, sockets, flanges etc. for making water line connection for various package Units of system etc. complete as required. (a) 40 mm UPVC Pipe | 8 | meter | satcj75@bsnl | 30 | |
| 7 | Plumbing work for drainage requirement | SITC of Plumbing work for drainage requirement with following size pipes including reducer, elbows, tees, unions, bends, sockets, flanges etc. for making water line connection for various package Units of system etc. complete as required. (b) 20 mm UPVC Pipe | 3 | meter | satcj75@bsnl | 30 | |
| 8 | Powder coating M.S. cable trays | Supplying and installing following size of perforated painted with Powder coating M.S. cable trays in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (a) 100 mm width x 50 mm x 1.6 mm thickness | 5 | meter | satcj75@bsnl | 30 | |
| 9 | Powder coating M.S. cable trays | Supplying and installing following size of perforated painted with Powder coating M.S. cable trays in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (b) 150 mm width x 50 mm x 1.6 mm thickness | 5 | meter | satcj75@bsnl | 30 | |
| 10 | wall opening | Pdg. Making wall opening to increase the return air area complete including with finishing the same and shifting the debris or malba etc. to ground floor as directed by E-IN-C | 1 | sq mtr | satcj75@bsnl | 30 | |
| 11 | Dismantling and removing the existing laid old power or control cables | Dismantling and removing the existing laid old power or control cables of condenser fans, old package units, condenser units etc. complete by unscrewing or cutting from the related M.S. racks or tray as required, unloading the same from different floors to ground floor and shifting the same to the place inside the exchange premises | 90 | meter | satcj75@bsnl | 30 | |
| 12 | Dismantling or removing the existing fitted old package A.C. units | Dismantling or removing the existing fitted old package A.C. units with related condensers and accessories like canvas, damper and unloading the same from different floors and terrace to ground floor along with shifting the same to the place inside the exchange premises. | 3 | set | satcj75@bsnl | 30 | |
| 13 | Recovering the existing laid refrigerant piping of old Hot gas and cold gas | Recovering the existing laid refrigerant piping of old Hot gas and cold gas of different sizes from different floors to ground floor and shifting the same to the place inside the exchange premises | 90 | meter | satcj75@bsnl | 30 | |
| 14 | Dismantling the existing fitted old MS racks | Dismantling the existing fitted old MS racks of cables or gas line pipes viz angle , square pipe, bar, hangers etc. along with shifting the same from different floors to ground floor | 1 | job | satcj75@bsnl | 30 | |
| 15 | Dismantling or removing the old condensate drain piping | Dismantling or removing the existing laid old condensate drain piping, unloading the same from different floors to ground floor including shifting the same to place inside the exchange premise | 18 | meter | satcj75@bsnl | 30 | |
| 16 | Dismantling the existing old ducts of package units | Dismantling the existing old ducts of package units along with fine filters and plenum complete by unscrewing, opening the flanges, supports,hangers | 30 | sq mtr | satcj75@bsnl | 30 | |
| 17 | Dismentalling of LT Panel from AC Plant room | Dismentalling of LT Panel from AC Plant room having 02 incommers and 06 outgoings under BA Jaipur including disconnection of all cable end terminations , loading , unloading and shifting the same to Tax Bldg., M.I.Road, Jaipur | 1 | job | satcj75@bsnl | 30 | |
| 18 | Transportation of the existing fitted old dissmantled package A.C. units | Transportation of the existing fitted old dissmantled package A.C. units with related condensers & accessories like Cu-piping,Cu- cable, damper, ducts, Trays, LT panel etc under BA Jaipur. Approx Distance upto 100Km and shifting the same to Tax Bldg., M.I.Road, Jaipur | 3 | job | satcj75@bsnl | 30 | |
| 19 | ITC of 7TR HPAC Package | Installation, testing and commissioning of above 7TR HPAC Package indoor and outdoor units on existing frame, pressure testing iincluding performance testing | 3 | job | satcj75@bsnl | 30 | |
| 20 | Supplying and Charging of the Refrigerant Gas | Supplying and Charging of the Refrigerant Gas R-407 C or R-410 A or same as per Originally supplied with PKG Units including Pressure testing | 45 | kg | satcj75@bsnl | 30 | |
| 21 | copper referigerant piping | Supply and fixing of the following sizes 18 gauge copper referigerant piping on the MS perforated tray (a) size 1-1/8 single run | 5 | meter | satcj75@bsnl | 30 | |
| 22 | copper referigerant piping | Supply and fixing of the following sizes 18 gauge copper referigerant piping on the MS perforated tray (b) size 7/8 single run | 5 | meter | satcj75@bsnl | 30 | |
| 23 | Laying of recovered copper referigerant piping | Laying of following sizes of existing recovered copper referigerant piping on the MS perforated tray (a) size 1-1/8 single run | 45 | meter | satcj75@bsnl | 30 | |
| 24 | Laying of recovered copper referigerant piping | Laying of following sizes of existing recovered copper referigerant piping on the MS perforated tray (b) size 7/8 single run | 45 | meter | satcj75@bsnl | 30 | |
| 25 | Providing MS structure | Providing MS structure for outdoor or Indoor units made out of solid channels , angles, flat | 50 | kg | satcj75@bsnl | 30 | |
| 26 | ITC of following old recovered items | (a) 100 mm width x 50 mm x 1.6 mm thickness | 20 | meter | satcj75@bsnl | 30 | |
| 27 | ITC of following old recovered items | (b) 150 mm width x 50 mm x 1.6 mm thickness | 20 | meter | satcj75@bsnl | 30 | |
| 28 | ITC of following old recovered items | (c) 4 x 1.5 sqmm Cable | 45 | meter | satcj75@bsnl | 30 | |
| 29 | ITC of following old recovered items | (d) 4 x 10 sqmm Cable | 20 | meter | satcj75@bsnl | 30 | |
| 30 | ITC of following old recovered items | (e) Existing Duct or Fire dampers in supply air main ducts or branch ducts | 3 | number | satcj75@bsnl | 30 | |
| 31 | ITC of following old recovered items | (f) 25 mm x 5 mm thick G.I. strip for loop earthing on cable tray or wall | 30 | meter | satcj75@bsnl | 30 | |
| 32 | Providing and fixing 25 mm X 5 mm G.I. strip | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections | 15 | meter | satcj75@bsnl | 30 | |
| 33 | 06 mm thick rubber matting | SITC of 06 mm thick ISI marked rubber matting | 2 | sq mtr | satcj75@bsnl | 30 | |
| 34 | Liquid line filter drier | Supply and Fixing the Liquid line filter drier suitable for R 407C or R410A Refrigerant Make Danfoss | 3 | number | satcj75@bsnl | 30 | |
| 35 | Installation Testing Commissioning of existing Electrical LT Panel | Installation Testing Commissioning of above existing Electrical LT Panel including connection of cables | 1 | job | satcj75@bsnl | 30 | |
| 36 | end termination with brass compression gland and aluminium lugs | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3.5 X 70 sqmm | 2 | set | satcj75@bsnl | 30 | |
| 37 | Aluminium Conductor Power Cable of 1.1 KV Grade | Supplying and Laying or fixing of Aluminium Conductor Power Cable of 1.1 KV Grade of following size on wall surface or trench or on tray (a) 3.5 X 70 sq. mm | 25 | meter | satcj75@bsnl | 30 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Key insights about RAJASTHAN tender market
The eligibility requirements include being a registered entity, possessing relevant experience in HVAC system deployments, and demonstrating technical capability through previous successful implementations of similar projects. Bidders must also adhere to any legal stipulations set by the Department of Telecommunications.
Bidders must submit certificates confirming compliance with quality standards for all equipment offered, as well as any business licenses and registration documents that validate their capacity to carry out the intended work. Documentation reflecting adherence to local regulations is also essential.
The registration process involves creating an account on the designated tender portal and completing a registration form providing all necessary business details. Bidders must ensure that all information is accurate and complete to avoid disqualification during the evaluation phase.
Accepted document formats typically include PDF and JPEG for uploading reference materials. Bidders should ensure the documents are legible, properly formatted, and free from any alterations that could misrepresent their offer.
The payment terms are usually aligned with project milestones or deliverables. A performance security in the form of bank guarantees or other financial instruments may be required to ensure compliance with contract terms. Bidders should be prepared to discuss this aspect during evaluation.
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS