TenderDekho Logo
GEM

Bids are Invited For General Servicing of 1.5 or 2.0 TR WAC or SAC units,SITC of 1.5 TR Resiprocating Type Compressor,SI in JAIPUR, RAJASTHAN

Bid Publish Date

03-Feb-2026, 4:03 pm

Bid End Date

25-Feb-2026, 3:00 pm

EMD

₹35,645

Value

₹17,82,234

Progress

Issue03-Feb-2026, 4:03 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1866

Category

General Servicing of 1.5 or 2.0 TR WAC or SAC units

Bid Type

Two Packet Bid

Bharat Sanchar Nigam Limited Portal(bsnl) invites bids for General Servicing of 1. 5 or 2. 0 TR WAC or SAC units, SITC of 1. 5 TR Resiprocating Type Compressor, SITC of 2 TR Resiprocating Type Compressor, SITC of 1. 5 TR Rotary Type Compressor, Charging of Refrigerant Gas for 1. 5 TR WAC or Split AC, Charging of Refrigerant Gas for 2. 0 TR WAC or Split AC, Replacement and Reparing of Thermostate, Replacement and Reparing of Starting capacitor 80 to 100 or 120 mfd, Replacement and Reparing of Running capacitor 36 or 40 mfd, Replacement and Reparing of Relay for WAC or Split AC, Replacement and Reparing of Wiring kit for WAC unit, Replacement and Reparing of Selector Switch for WAC unit, Rewinding of Condensor or Blower Motor for AC unit incuding replacement of bush, Replacement and Reparing of Blower Fan Motor Capacitor 4 or 6 mfd, Repairing of PCB for WAC or Split Remote Control unit, Replacement of faulty or Irrepairable PCB for 1. 5TR Split AC Unit, SITC of Blower fan motor for 1. 5 or 2 TR window or split AC, Supplying, Installation of condensor or Blower fan blade, Top Up or Additional Charging of R-22 or 32 gas, Supplying and drawing of 3X2. 5 sq. mm FRLS PVC copper single core cable, Supplying and drawing of 6X2. 5 sq. mm FRLS PVC copper single core cable, Supplying and fixing of 20mm medium class PVC conduit, Supplying and fixing of 25mm medium class PVC conduit, Supplying and fixing DP sheet steel enclosure with 25 or 32amps 240 volts C curve DP MCB, Supplying and fixing of 5 A to 32 A rating, 240 or 415 V, 10 kA, C curve, SPN MCB, Supplying and fixing of 3X2. 5 sq. mm PVC FRLS Round sheathed Multi Core Bright Annealed Bare Copper cable, Dismentalling of existing 1. 5 or 2. 0 TR Capacity Window or Split AC Units, Transportation of existing 1. 5 or 2. 0 TR Capacity Window or Split AC Units, ITC of 1. 5 or 2. 0 TR Capacity Split AC Units, Pdg and fixing of 1 by 4 inch dia copper refrigerant piping, Pdg and fixing of 5 by 8 inch dia copper refrigerant piping, Providing and fixing 12 mm thick particle board, Supplying and fixing suitable size MS Stand for split type AC outdoor unit in JAIPUR, RAJASTHAN. Quantity: 1866. Submission Deadline: 25-02-2026 15: 00: 00. Submit your proposal before the deadline.

Documents 5

GeM-Bidding-8925810.pdf

Main Document

BOQ Document

BOQ

BOQ Document

BOQ

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

BSNL DOT AC & Cabling Procurement Tender Rajasthan? Bharat Sanchar Nigam Limited security and electrical equipment supply 2025

Bharat Sanchar Nigam Limited Portal(bsnl)

CHENNAI, TAMIL NADU

Posted: 29 December 2025
Closed: 9 January 2026
GEM

28 HP heat pump outdoor VRV OR VRF,26 HP heat pump outdoor VRV OR VRF,4 Way 3.0 Tr VRF Cassette Ind

State Bank Of India (sbi)

LUCKNOW, UTTAR PRADESH

Posted: 15 December 2025
Closed: 31 December 2025
GEM

Hi wall Split AC 2.0 Tr,Hi wall Split AC 1.5 Tr,Additional Copper pipe for Hi wall split AC,Cable f

State Bank Of India (sbi)

LUCKNOW, UTTAR PRADESH

Posted: 19 December 2025
Closed: 30 December 2025
GEM

State Bank of India Deoria SBI procurement: Hi-Wall Split AC 2.0/1.5/1.0 TR, Copper Piping, Stabiliser & Installation 2025

State Bank Of India (sbi)

DEORIA, UTTAR PRADESH

Posted: 18 December 2025
Closed: 29 December 2025
GEM

Supplying of 1.5 TR wall mounting, Non Inverter type Split Air Conditioner units as mentioned in BO

New Mangalore Port Authority

DAKSHINA KANNADA, KARNATAKA

Posted: 1 December 2025
Closed: 22 December 2025
GEM

Bill of Quantities (BOQ) 33 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 General Servicing of 1.5 or 2.0 TR WAC or SAC units General Servicing of 1.5/2.0 TR WAC/SAC units of different make i/c removing from existing position if reqd., dismentling of faulty parts, cleaning the air filter, cleaning the condesor and evaporator coil with help of chemical solution & Water, lubrication of moving parts, complete checking, testing and minor faults rectification i/c replacement of knobs, setting of thermostate etc complete as reqd. 255 job satcj75@bsnl 180
2 SITC of 1.5 TR Resiprocating Type Compressor Supply of the 1.5 TR capacity New Hermatically sealed Reciprocating type Compressor purchased from the authorised dealer i/c dismentalling of the faulty compressor from site, to and fro transportation charges for compressor and I/T/C of New compressor in place of faulty compressor of existing WAC/Split AC etc complete as required. 12 job satcj75@bsnl 180
3 SITC of 2 TR Resiprocating Type Compressor Supply of the 2.0 TR capacity New Hermatically sealed Reciprocating type Compressor purchased from the authorised dealer i/c dismentalling of the faulty compressor from site, to and fro transportation charges for compressor and I/T/C of New compressor in place of faulty compressor of existing WAC/Split AC etc complete as required. 6 job satcj75@bsnl 180
4 SITC of 1.5 TR Rotary Type Compressor Supply of the 1.5 TR capacity New Hermatically sealed Rotary type Compressor purchased from the authorised dealer i/c dismentalling of the faulty compressor from site, to and fro transportation charges for compressor and I/T/C of New compressor of existing WAC/Split AC etc complete as required. 31 job satcj75@bsnl 180
5 Charging of Refrigerant Gas for 1.5 TR WAC or Split AC Charging of Refrigerant Gas R-22/ 32 upto specified pressure in 1.5 TR capacity AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing, commissioning of the AC unit etc as reqd. 45 job satcj75@bsnl 180
6 Charging of Refrigerant Gas for 2.0 TR WAC or Split AC Charging of Refrigerant Gas R-22/ 32 upto specified pressure in 2.0 capacity AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing, commissioning of the AC unit etc as reqd. 10 job satcj75@bsnl 180
7 Replacement and Reparing of Thermostate Replacement and Reparing of the Thermostate in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 23 number satcj75@bsnl 180
8 Replacement and Reparing of Starting capacitor 80 to 100 or 120 mfd Replacement and Reparing of the Starting capacitor (80-100/120 mfd) in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 88 number satcj75@bsnl 180
9 Replacement and Reparing of Running capacitor 36 or 40 mfd Replacement and Reparing of the Running capacitor (36/40 mfd) in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 103 number satcj75@bsnl 180
10 Replacement and Reparing of Relay for WAC or Split AC Replacement and Reparing of the Relay for WAC / Split AC in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 27 number satcj75@bsnl 180
11 Replacement and Reparing of Wiring kit for WAC unit Replacement and Reparing of the Wiring kit for WAC unit in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 21 number satcj75@bsnl 180
12 Replacement and Reparing of Selector Switch for WAC unit Replacement and Reparing of the Selector Switch for WAC unit in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 22 number satcj75@bsnl 180
13 Rewinding of Condensor or Blower Motor for AC unit incuding replacement of bush Rewinding of Condensor/Blower Motor for AC unit i/c replacement of bush in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 87 number satcj75@bsnl 180
14 Replacement and Reparing of Blower Fan Motor Capacitor 4 or 6 mfd Replacement and Reparing of the Blower Fan Motor Capacitor 4/6 mfd in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 88 number satcj75@bsnl 180
15 Repairing of PCB for WAC or Split Remote Control unit Repairing of PCB for WAC/Split Remote Control unit in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 54 job satcj75@bsnl 180
16 Replacement of faulty or Irrepairable PCB for 1.5TR Split AC Unit Replacement of faulty / Irrepairable PCB for 1.5TR Split AC Unit in the existing AC units in place of fulty, fixing, the new item and testing, connection etc. complete as reqd. 29 job satcj75@bsnl 180
17 SITC of Blower fan motor for 1.5 or 2 TR window or split AC SITC of Blower fan motor for 1.5/2 TR window/split AC unit in lieu of damaged i/c connection etc as reqd. 42 number satcj75@bsnl 180
18 Supplying, Installation of condensor or Blower fan blade Supplying, Installation of condensor / Blower fan blade same as per existing PVC / Metal Blade in lieu of damaged i/c fixing the same etc as req. 61 number satcj75@bsnl 180
19 Top Up or Additional Charging of R-22 or 32 gas Provision of Top Up / Additional Charging of R-22/32 gas upto specified pressue in existing window AC / Split AC units i/c flushing, gas charging, testing etc complete as reqd. 124 kilogram satcj75@bsnl 180
20 Supplying and drawing of 3X2.5 sq. mm FRLS PVC copper single core cable Supplying and drawing 3X2.5 sq. mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 66 meter satcj75@bsnl 180
21 Supplying and drawing of 6X2.5 sq. mm FRLS PVC copper single core cable Supplying and drawing 6X2.5 sq. mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 36 meter satcj75@bsnl 180
22 Supplying and fixing of 20mm medium class PVC conduit Supplying and fixing of 20mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 61 meter satcj75@bsnl 180
23 Supplying and fixing of 25mm medium class PVC conduit Supplying and fixing of 25 mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 46 meter satcj75@bsnl 180
24 Supplying and fixing DP sheet steel enclosure with 25 or 32amps 240 volts C curve DP MCB Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts C curve DP MCB complete with connections, testing and commissioning etc. as required. 27 number satcj75@bsnl 180
25 Supplying and fixing of 5 A to 32 A rating, 240 or 415 V, 10 kA, C curve, SPN MCB Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of Single pole and neutral poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 45 number satcj75@bsnl 180
26 Supplying and fixing of 3X2.5 sq. mm PVC FRLS Round sheathed Multi Core Bright Annealed Bare Copper cable Supplying and fixing of 3X2.5 sq. mm PVC insulated and FRLS Round sheathed Multi Core Bright Annealed Bare Copper conductor Heavy duty industrial cable for voltage grade up to 1100 Volts as per IS 694-1990 i/c fixing on wall with suitable clamp/saddle etc. complete as reqd. 100 meter satcj75@bsnl 180
27 Dismentalling of existing 1.5 or 2.0 TR Capacity Window or Split AC Units Dismentalling of existing 1.5 / 2.0 TR Capacity Window / Split AC Units along with Indoor / Outdoor Units & all other existing accessories including disconnection of Electrical connection, Copper PIping, Drain Piping , Stand etc. from existing location of TE / BTS site under SSA concerned and reparing of any damage during dismentling by making good the same etc. complete as reqd. 36 job satcj75@bsnl 180
28 Transportation of existing 1.5 or 2.0 TR Capacity Window or Split AC Units Transportation of existing 1.5 / 2.0 TR Capacity Window / Split AC Units along with all accessories etc from TE / BTS Site of SSA under BA to Store / Any Place in same SSA as directed by Engg. in Charge by transport by truck / Loading Vehicle i/c loading, Unloading & Safe Handling etc.complete as reqd. 34 job satcj75@bsnl 180
29 ITC of 1.5 or 2.0 TR Capacity Split AC Units Installation of 1.5 / 2.0 TR Capacity Split AC Units with Indoor and outdoor unit I/c fixing the refrigerant piping with insulation, cutting, brazing, laying the cable along with the piping connections, repairing the minor leakages of the complete system i/c testing, commissioning of Split type AC unit etc. complete as reqd. 38 job satcj75@bsnl 180
30 Pdg and fixing of 1 by 4 inch dia copper refrigerant piping Pdg and fixing 1/4 inch dia copper refrigerant piping i/c covering of copper piping with polystyrene insulation i/c cutting, brazing, jointing, bends, sockets etc as reqd. 95 meter satcj75@bsnl 180
31 Pdg and fixing of 5 by 8 inch dia copper refrigerant piping Pdg and fixing 5/8 inch dia copper refrigerant piping i/c covering of copper piping with polystyrene insulation i/c cutting, brazing, jointing, bends, sockets etc as reqd. 95 meter satcj75@bsnl 180
32 Providing and fixing 12 mm thick particle board P/F 12 mm thick particle board on surface of wall for fixing the indoor unit of split type AC Unit or Fixing / Covering the Extra Space etc. with the help of screw complete etc. as reqd 25 sq meter satcj75@bsnl 180
33 Supplying and fixing suitable size MS Stand for split type AC outdoor unit S/F suitable size MS Stand for placement of split type AC outdoor unit made out of 16 gauge powder coated MS sheet i/c fixing with help of 4 Nos. fasteners for grouting on wall / floor, etc. complete as required. 34 number satcj75@bsnl 180

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

4 found

Supply 1.5 TR Inverter Metal body Ductable SAC,ITC 1.5 TR Inverter Metal body Ductable SAC,S fixing

Bharat Sanchar Nigam Limited Portal(bsnl)

📍 AHMEDABAD, GUJARAT

EMD: ₹80,886
Est: ₹40.4 L
⏰ Deadline: 4 weeks left
🛒 Type: Goods
View GEM

3 TR single circuit 1 OR 3 Phase,1.5TR single circuit 1 OR 3 Phase,ITC of 1.5 or 3.0 TR DAC unit,40

Bharat Sanchar Nigam Limited Portal(bsnl)

📍 ROHTAK, HARYANA

EMD: ₹1.7 L
Est: ₹86.2 L
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM
Urgent

Split Type Ac 1.5,Split Type Ac 2.0,Supply and Installation,Supply of outdoor stand,SITC

Sports Authority Of India (sai)

📍 ROHTAK, HARYANA

EMD: ₹30,000
Est: ₹15.0 L
⏰ Deadline: 2 days left
🛒 Type: Goods
View GEM
Urgent

point wiring group c,wiring with 2c 1.5sq mm cu wire in PVC conduit with earthing,wiring with 2c 6s

Bharat Sanchar Nigam Limited Portal(bsnl)

📍 AHMEDABAD, GUJARAT

Est: ₹2.5 L
⏰ Deadline: 1 day left
🛒 Type: Goods
View GEM