TRUCK3TON13FEET,TRUCK3TON13FEET,TRUCK3TON13FEET,TRUCK3TON13FEET,TRUCK3TON13FEET,TRUCK3TON13FEET,TRU
Indian Air Force
GURGAON, HARYANA
Bid Publish Date
08-Aug-2025, 2:32 pm
Bid End Date
29-Aug-2025, 3:00 pm
EMD
₹20,000
Value
₹9,66,000
Location
Progress
Quantity
392
Category
Trainingcenter1
Bid Type
Two Packet Bid
Jawaharlal Nehru Port Trust announces a tender for Trainingcenter1, Trainingcenter2, Trainingcenter3, Trainingcenter4, Trainingcenter5, Trainingcenter6, Trainingcenter7, Trainingcenter8, Trainingcenter9, Trainingcenter10, Trainingcenter11, Trainingcenter12, Trainingcenter13, Trainingcenter14, Trainingcenter15, Trainingcenter16 in RAIGAD, MAHARASHTRA. Quantity: 392. Submission Deadline: 29-08-2025 15: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Trainingcenter1 , Trainingcenter2 , Trainingcenter3 , Trainingcenter4 , Trainingcenter5 , Trainingcenter6 , Trainingcenter7 , Trainingcenter8 , Trainingcenter9 , Trainingcenter10 , Trainingcenter11 , Trainingcenter12 , Trainingcenter13 , Trainingcenter14 , Trainingcenter15 , Trainingcenter16
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Air Force
GURGAON, HARYANA
Bharat Heavy Electricals Limited (bhel)
Uranium Corporation Of India Limited
CUDDAPAH, ANDHRA PRADESH
Bhilai Steel Plant
DURG, CHHATTISGARH
Indian Oil Corporation Limited
MATHURA, UTTAR PRADESH
Tender Results
Loading results...
Trainingcenter1
AIR HANDLING UNIT Supply installation testing and commissioning of Double skin air handling unit in comprising of fan section with direct driven plug fan cooling section with 8 rows deep cooling coil pre filter having efficiency 90 percent down to 10 micron filters the outdoor skin will be 0.6 mm PPGI and inner skin 0.6 mm PPGI sheet Unit shall be horizontal draw through type arranged for horizontal discharge Capacity 1500 cfm 50 mmwg
Trainingcenter2
Refrigerant pipe with insulation 8.5 TR suction line
Trainingcenter3
Refrigerant pipe with insulation 8.5 TR Discharge Line
Trainingcenter4
Miscellaneous items like controls for condensing units like expansion valves hand shut off valves catch all dryers thermostats complete with first charged of refrigerant gas
Trainingcenter5
AHU drain pipe line from AHU to drain area with insulation
Trainingcenter6
AIR DISTRIBUTION SYSTEM Ducts shall be made of GSS with curves and bends where indicated for easy flow of air an ensured to be air tight by applying silicon sealant after fabrication hangers shall be provided to GI ducts and shall be not more than 2.5 m apart 24 Gauge 0.63 mm
Trainingcenter7
Thermal insulation 25 mm thick with cross link polyethylene for supply air duct Thermal insulation with cross link polyethylene for return air duct
Trainingcenter8
Canvas connection for AHU
Trainingcenter9
ELECTRICAL PANEL SITC AHU Control Panel with MCB and starter with LED indicator as instructed and as directed by OIC-ES IP 55 Fuseless control Floor Mounted
Trainingcenter10
Single compression gland
Trainingcenter11
SITC of Power cable for Electrical Panel 4C by 2.5 Sqmm
Trainingcenter12
SITC Green Colour Earthing Cable 2.5 Sqmm for all 3 Phase Equipments
Trainingcenter13
Temperature Sensor 50 150 and 4 to 20 ma
Trainingcenter14
M S Fabrication for AHU and Condensing Unit
Trainingcenter15
Electrical control panel for Air curtain
Trainingcenter16
Existing AHU and system Dismantling and keeping in store
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Trainingcenter1 | AIR HANDLING UNIT Supply installation testing and commissioning of Double skin air handling unit in comprising of fan section with direct driven plug fan cooling section with 8 rows deep cooling coil pre filter having efficiency 90 percent down to 10 micron filters the outdoor skin will be 0.6 mm PPGI and inner skin 0.6 mm PPGI sheet Unit shall be horizontal draw through type arranged for horizontal discharge Capacity 1500 cfm 50 mmwg | 1 | nos | [email protected] | 90 | |
| 2 | Trainingcenter2 | Refrigerant pipe with insulation 8.5 TR suction line | 20 | rmt | [email protected] | 90 | |
| 3 | Trainingcenter3 | Refrigerant pipe with insulation 8.5 TR Discharge Line | 20 | rmt | [email protected] | 90 | |
| 4 | Trainingcenter4 | Miscellaneous items like controls for condensing units like expansion valves hand shut off valves catch all dryers thermostats complete with first charged of refrigerant gas | 2 | nos | [email protected] | 90 | |
| 5 | Trainingcenter5 | AHU drain pipe line from AHU to drain area with insulation | 10 | rmt | [email protected] | 90 | |
| 6 | Trainingcenter6 | AIR DISTRIBUTION SYSTEM Ducts shall be made of GSS with curves and bends where indicated for easy flow of air an ensured to be air tight by applying silicon sealant after fabrication hangers shall be provided to GI ducts and shall be not more than 2.5 m apart 24 Gauge 0.63 mm | 10 | sqmt | [email protected] | 90 | |
| 7 | Trainingcenter7 | Thermal insulation 25 mm thick with cross link polyethylene for supply air duct Thermal insulation with cross link polyethylene for return air duct | 30 | sqmt | [email protected] | 90 | |
| 8 | Trainingcenter8 | Canvas connection for AHU | 1 | nos | [email protected] | 90 | |
| 9 | Trainingcenter9 | ELECTRICAL PANEL SITC AHU Control Panel with MCB and starter with LED indicator as instructed and as directed by OIC-ES IP 55 Fuseless control Floor Mounted | 1 | nos | [email protected] | 90 | |
| 10 | Trainingcenter10 | Single compression gland | 4 | nos | [email protected] | 90 | |
| 11 | Trainingcenter11 | SITC of Power cable for Electrical Panel 4C by 2.5 Sqmm | 20 | rmt | [email protected] | 90 | |
| 12 | Trainingcenter12 | SITC Green Colour Earthing Cable 2.5 Sqmm for all 3 Phase Equipments | 20 | rmt | [email protected] | 90 | |
| 13 | Trainingcenter13 | Temperature Sensor 50 150 and 4 to 20 ma | 1 | nos | [email protected] | 90 | |
| 14 | Trainingcenter14 | M S Fabrication for AHU and Condensing Unit | 250 | kg | [email protected] | 90 | |
| 15 | Trainingcenter15 | Electrical control panel for Air curtain | 1 | nos | [email protected] | 90 | |
| 16 | Trainingcenter16 | Existing AHU and system Dismantling and keeping in store | 1 | lot | [email protected] | 90 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | AIRNIC INFRA PRIVATE LIMITED Under PMA | - | 23-08-2025 17:21:17 | |
| 2 | AQUA COOL CO PRIVATE LIMITED Under PMA | - | 26-08-2025 17:38:49 | |
| 3 | COOLAGE Under PMA | - | 29-08-2025 12:23:18 | |
| 4 | RAJ AIRCON PRIVATE LIMITED Under PMA | - | 26-08-2025 11:23:11 |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | RAJ AIRCON PRIVATE LIMITED(MSE,MII)( MSE Social Category:SC ) Under PMA | Item Categories : Trainingcenter1,Trainingcenter2,Trainingcenter3,Trainingcenter4,Trainingcenter5,Trainingcenter6,Tra |
Please sign in or create an account to view contract details and download result documents.
Indian Army
📍 DARJEELING, WEST BENGAL
Ntpc Limited
📍 BILASPUR, CHHATTISGARH
Ntpc Limited
📍 NALANDA, BIHAR
Hindustan Aeronautics Limited (hal)
📍 BANGALORE, KARNATAKA
Eastern Coalfields Limited
📍 BARDHAMAN, WEST BENGAL
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS