Airports Authority Of India invites bids for Copper plate, Copper strip, Copper Rod lighning arrestor, Insulated copper wire, Ring fit Push Fit GI Perforated Pipe, Heavy duty PVC pipe, Extension Board with indiviudal switch, Ladder, Copper clad rod, 3 Core Electrical cable, Steel guide wire, Weather Proof CPVC Box, Braided copper wire, FRP Poles, SS pulley with hook, Strain insulator Glass or Ceramic, Strainig scews, steel guy wire, Bulldog Grips, GI ground fixing arragment, Earth distribution plates, SS full thread stud, GI perforated Cable Tray, PVC Plastic Tray with Cover, Epoxy DMC Electrical insulator in ERNAKULAM, KERALA. Quantity: 3256. Submission Deadline: 03-11-2025 17: 00: 00. Submit your proposal before the deadline.
Invitation to Bid – Copper plate,Copper strip,Copper Rod lighning arrestor,Insulated copper wire,Ring fit Push Fit GI P in ERNAKULAM, KERALA
Progress
Quantity
3256
Category
FRP Poles
Bid Type
Two Packet Bid
   
Categories
 21  
     
Bill of Quantities (BOQ)
 25 Items  
 | Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | 
|---|---|---|---|---|---|---|
| 1 | Copper plate | At lest 600mm X 600mm X 3.15mm(thickness) purity not less than 90% | 11 | pieces | vipinpdas | 45 | 
| 2 | Copper strip | At least 25 mm X 3 mm(thickness).Purity atleast not less than 90% | 800 | meters | vipinpdas | 45 | 
| 3 | Copper Rod lighning arrestor | ( 1 Inch diameter of 5 feet length) Purity at least not less than 90% | 3 | pieces | vipinpdas | 45 | 
| 4 | Insulated copper wire | PVC insulated Copper cable,Green Colour of 75 sq.mm. | 600 | meters | vipinpdas | 45 | 
| 5 | Ring fit Push Fit GI Perforated Pipe | 40mm OD X 3 Meter Long X 5 mm Thickness | 11 | pieces | vipinpdas | 45 | 
| 6 | Heavy duty PVC pipe | Plastic corrugated Hose 2 inch diameter. | 30 | pieces | vipinpdas | 45 | 
| 7 | Extension Board with indiviudal switch | 4 X 5/15 Amps, 30 Meter long cable using 3 X 1.5 sq.mm copper conductor and armoured PVC sheathed. | 2 | pieces | vipinpdas | 45 | 
| 8 | Ladder | Self supporting Heavy duty Folding Ladder.2 cross leg Minimum 4- 6 feet | 2 | pieces | vipinpdas | 45 | 
| 9 | Copper clad rod | 10 Feet Length X 3/4 inch diameter. 3 mm copper coated steel rod. | 12 | pieces | vipinpdas | 45 | 
| 10 | 3 Core Electrical cable | 3 X 2.5 sq. mm multi strand copper conductor PVC sheathed. | 600 | meters | vipinpdas | 45 | 
| 11 | Steel guide wire | Single/multi strand for laying inside GI pipe. 4 mm dia. | 600 | meters | vipinpdas | 45 | 
| 12 | Weather Proof CPVC Box | 1 feet X 1 Feet X 6 inch | 10 | pieces | vipinpdas | 45 | 
| 13 | Braided copper wire | Multi strand Copper rope 70 sq. mm cross section | 100 | meters | vipinpdas | 45 | 
| 14 | FRP Poles | with 4 bolt mounting pedestals( 100 mm dia,5 mm thickness length 4 M) | 8 | pieces | vipinpdas | 45 | 
| 15 | SS pulley with hook | Diameter 3 inch(For running at least 10 mm multistrand copper braided wire) | 8 | pieces | vipinpdas | 45 | 
| 16 | Strain insulator Glass or Ceramic | 6 inches(Holes in insulator should be as such to pass the item at No.15) | 3 | pieces | vipinpdas | 45 | 
| 17 | Strainig scews | With anchor bolts at least 1 foot | 8 | pieces | vipinpdas | 45 | 
| 18 | steel guy wire | 8 mm dia(Multistrand) | 100 | meters | vipinpdas | 45 | 
| 19 | Bulldog Grips | For 8 mm steel/copper rope.Shall be able to hold 8mm dia steel/copper rope. | 100 | pieces | vipinpdas | 45 | 
| 20 | GI ground fixing arragment | For 8 No. of FRP poles | 8 | sets | vipinpdas | 45 | 
| 21 | Earth distribution plates | Copper bus bar at least 50mm X 6 mm(Width X Thickness) | 10 | pieces | vipinpdas | 45 | 
| 22 | SS full thread stud | 12mm OD with 60 pcs of Nut and 120 washers. | 10 | pieces | vipinpdas | 45 | 
| 23 | GI perforated Cable Tray | ( 4 inch width ) With Cover | 50 | feet | vipinpdas | 45 | 
| 24 | PVC Plastic Tray with Cover | 4 inch width X 2 inch depth | 150 | feet | vipinpdas | 45 | 
| 25 | Epoxy DMC Electrical insulator | Round shape (red) with bolt. | 20 | pieces | vipinpdas | 45 | 
AI-Powered Bidder Prediction
Companies most likely to bid
Unlock Bidder Insights
AI predictions on likely bidders
Required Documents
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
   
Similar Tenders
 Tube light,MCCB,Cable,Tube light,MCCB,Street light,Flood light,Flood light,Cable,Copper Cable,Coppe
Department of Military Affairs
JAMNAGAR, GUJARAT
CGI Sheet 8 feet,Aggregate 20mm,Sand,Cement,Stone Bolder,Stone Bolder,PVC Cable,Bed Switch,Socket 5
Department of Military Affairs
JAMMU, JAMMU & KASHMIR
Download FREE!
Access all tender documents at no cost
    Documents  5  
 GeM-Bidding-8471395.pdf
Main Document
BOQ Document
BOQ
BOQ Document
BOQ
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS
GeM-Bidding-8471395.pdf
Main Document
BOQ Document
BOQ
BOQ Document
BOQ
Buyer uploaded ATC document
ATC
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS