Bid Publish Date
14-May-2025, 6:21 pm
Bid End Date
10-Jun-2025, 11:00 am
EMD
₹1,79,847
Value
₹89,92,350
Location
Progress
RAQuantity
4432
Category
Attending complaint of EA set located between 100 KM to 200 KM
Bid Type
Two Packet Bid
Bharat Sanchar Nigam Limited Portal(bsnl) has released a public tender for Attending complaint of EA set located upto 25 KM, Attending complaint of EA set located between 25 K in NAGPUR, MAHARASHTRA. Quantity: 4432. Submission Deadline: 10-06-2025 11: 00: 00. Download documents and apply online.
Main Document
OTHER
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Attending complaint of EA set located upto 25 KM | Attending EA set located upto 25KM from dist HQ incl rectification of minor fault in wiring, lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit | 120 | job | vijay@krishna | 30 |
| 2 | Attending complaint of EA set located between 25 KM to 50 KM | Attending EA set located between 25KM to 50KM from dist HQ incl rectification of minor fault in wiring, lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit | 120 | job | vijay@krishna | 30 |
| 3 | Attending complaint of EA set located between 50 KM to 100 KM | Attending EA set located between 50KM to 100KM from dist HQ incl rectification of minor fault in wiring, lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit | 100 | job | vijay@krishna | 30 |
| 4 | Attending complaint of EA set located between 100 KM to 200 KM | Attending EA set located between 100KM to 200KM from dist HQ incl rectification of minor fault in wiring, lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit | 80 | job | vijay@krishna | 30 |
| 5 | Carry out B check servicing of 7.5 KVA to 15 KVA EA set of various make | Carry out B check servicing of 7.5KVA to 15KVA EA set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd | 80 | job | vijay@krishna | 30 |
| 6 | Carry out B check servicing of above 15 KVA to 32.5 KVA EA set of various make | Carry out B check servicing of above 15KVA to 32.5KVA EA set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd | 80 | job | vijay@krishna | 30 |
| 7 | Carry out B check servicing of above 32.5 KVA to 62.5 KVA EA set of various make | Carry out B check servicing of above 32.5KVA to 62.5KVA EA set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd | 20 | job | vijay@krishna | 30 |
| 8 | Carry out B check servicing of above 62.5 KVA to 125 KVA EA set of various make | Carry out B check servicing of above 62.5KVA to 125KVA EA set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd | 20 | job | vijay@krishna | 30 |
| 9 | Carry out B check servicing of 160KVA EA set of various make | Carry out B check servicing of 160 KVA EA set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd | 4 | job | vijay@krishna | 30 |
| 10 | Carry out B check servicing of 200KVA EA set of various make | Carry out B check servicing of 200 KVA EA set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd | 4 | job | vijay@krishna | 30 |
| 11 | Carry out B check servicing of 250KVA EA set of various make | Carry out B check servicing of 250 KVA EA set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd | 4 | job | vijay@krishna | 30 |
| 12 | Providing and fixing of 12mm dia wire braided PVC diesel pipe | Providing and fixing of 12mm dia wire braided PVC pipe for diesel supply and return lines in existing EA set incl. testing, commissioning etc as reqd | 100 | meter | vijay@krishna | 30 |
| 13 | Providing and fixing of Benjo and Benjo bolt with washer and scew on pipe clamps at both ends | Providing and fixing of Benjo and Benjo bolt with washer and scew on pipe clamps at both ends for existing EA set incl. testing, commissioning etc as reqd | 100 | set | vijay@krishna | 30 |
| 14 | Providing and topping up of corrosion Inhibitor coolant for topping up in radiator | Providing and topping up of corrosion Inhibitor coolant in radiator of existing EA set incl. testing, commissioning etc. as reqd. | 100 | litre | vijay@krishna | 30 |
| 15 | Providing and topping up of 15W40 grade lubricating oil of recommended make | Providing and topping up of 15W40 grade lubricating oil of recommended make in existing EA set incl. testing, commissioning etc. as reqd. | 200 | litre | vijay@krishna | 30 |
| 16 | Providing and fixing of 2No. 50sqmm copper flexible cable leads each of 1 Mtr length incl. lugs and battery terminals at both ends | Providing and fixing of 2 No. 50 sqmm copper conductor flexible cable leads each of 1 Mtr length incl. lugs and battery terminals at both ends for starting battery of existing EA set as reqd. | 40 | job | vijay@krishna | 30 |
| 17 | Providing and fixing of battery terminal socket set for DG starting battery | Providing and fixing of battery terminal socket set for DG starting battery incl. testing, commissioning etc. as reqd. | 120 | set | vijay@krishna | 30 |
| 18 | Providing and fixing of stop solenoid valve suitable for 7.5 kVA to 32.5 kVA EA set | Providing and fixing of stop solenoid valve suitable for 7.5 kVA to 32.5 kVA EA set incl. testing, commissioning etc. as reqd. | 20 | job | vijay@krishna | 30 |
| 19 | Providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kVA to 125 kVA EA set | Providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kVA to 125 kVA EA set incl. testing, commissioning etc. as reqd. | 20 | job | vijay@krishna | 30 |
| 20 | Providing and fixing of radiator fan V belt set suitable for 7.5 kVA to 62.5 kVA EA set | Providing and fixing of radiator fan V belt set suitable for 7.5 kVA to 62.5 kVA EA set incl. testing, commissioning etc. as reqd. | 80 | job | vijay@krishna | 30 |
| 21 | Providing and fixing of radiator fan V belt set suitable for 75 kVA to 250 kVA EA set | Providing and fixing of radiator fan V belt set suitable for 75 kVA to 250 kVA EA set incl. testing, commissioning etc. as reqd. | 80 | job | vijay@krishna | 30 |
| 22 | Providing and fixing of Ignition switch or push button for EA set | Providing and fixing of Ignition switch or push button for EA set incl. testing, commissioning etc. as reqd. | 40 | job | vijay@krishna | 30 |
| 23 | Providing and fixing of engine start key switch | Providing and fixing of engine start key switch incl. testing, commissioning etc. as reqd. | 40 | no | vijay@krishna | 30 |
| 24 | Providing and fixing of oil pressure guage for EA set | Providing and fixing of oil pressure guage for EA set incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 25 | Providing and fixing of water temperature guage for EA set | Providing and fixing of water temperature guage for EA set incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 26 | Providing and fixing of oil temperature guage for EA set | Providing and fixing of oil temperature guage for EA set incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 27 | Providing and fixing of oil pressure guage pipe for EA set | Providing and fixing of oil pressure guage pipe for EA set incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 28 | Providing and fixing of LLOP switch for EA set | Providing and fixing of LLOP switch for EA set incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 29 | Providing and fixing of water temperature switch for EA set | Providing and fixing of water temperature switch for EA set incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 30 | Providing and fixing of relay card for start and stop of EA set | Providing and fixing of relay card for start and stop of EA set incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 31 | Providing and fixing of static AVR suitable for alternator of EA set upto 125 kVA | Providing and fixing of static AVR suitable for alternator of EA set upto 125 kVA incl. testing, commissioning etc. as reqd. | 40 | no | vijay@krishna | 30 |
| 32 | Providing and fixing of 12 Volt 10 Amp SMPS battery charger unit with necessary wires cable and accessories | Providing and fixing of 12 Volt 10 Amp SMPS battery charger unit with necessary wires cable and accessories incl. testing, commissioning etc. as reqd. | 40 | no | vijay@krishna | 30 |
| 33 | Providing and fixing of 24 Volt 10 Amp SMPS battery charger unit with necessary wires cable and accessories | Providing and fixing of 24 Volt 10 Amp SMPS battery charger unit with necessary wires cable and accessories incl. testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 34 | Providing and fixing of 2Way centre OFF 40A DP MCB type change over switch | Providing and fixing of 2 Way centre OFF 40A DP MCB type change over switch incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 35 | Providing and fixing of Digital RPM cum Hour meter | Providing and fixing of Digital RPM cum Hour meter incl. testing, commissioning etc. as reqd. | 40 | no | vijay@krishna | 30 |
| 36 | Providing and fixing of 8 or 11 pin, 12V or 24V DC Pla relay with base | Providing and fixing of 8 or 11 pin, 12V or 24V DC Pla relay with base incl. testing, commissioning etc. as reqd. | 40 | no | vijay@krishna | 30 |
| 37 | Providing and fixing of 8 or 11 pin, 240V AC Pla relay with base | Providing and fixing of 8 or 11 pin, 240V AC Pla relay with base incl. testing, commissioning etc. as reqd. | 40 | no | vijay@krishna | 30 |
| 38 | Providing and fixing of AC Ammeter 96 Sq.mm size and 0 to 200A or 400A range | Providing and fixing of AC Ammeter 96 Sq.mm size and 0 to 200A or 400A range incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 39 | Providing and fixing of DC Ammeter 72 Sq.mm size and 0 to 50A range | Providing and fixing of DC Ammeter 72 Sq.mm size and 0 to 50A range incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 40 | Providing and fixing of AC Voltmeter 96 Sq.mm size and 0 to 500V range | Providing and fixing of AC Voltmeter 96 Sq.mm size and 0 to 500V range incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 41 | Providing and fixing of DC Voltmeter 72 Sq.mm size and 0 to 50V range | Providing and fixing of DC Voltmeter 72 Sq.mm size and 0 to 50V range incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 42 | Providing and fixing of 32 Amp 4 pole contactor of AC23 duty | Providing and fixing of 32 Amp 4 pole contactor of AC23 duty incl. connections, testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 43 | Providing and fixing of 32 Amp contactor coil | Providing and fixing of 32 Amp contactor coil incl. testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 44 | Providing and fixing of 63 Amp 4 pole contactor of AC23 duty | Providing and fixing of 63 Amp 4 pole contactor of AC23 duty incl. connections, testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 45 | Providing and fixing of 63 Amp contactor coil | Providing and fixing of 63 Amp contactor coil incl. testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 46 | Providing and fixing of 6 to 32A 10KA C series SP MCB | Providing and fixing of 6 to 32A 10KA C series SP MCB incl. testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 47 | Providing and fixing of 6 to 32A 10KA C series SPN MCB | Providing and fixing of 6 to 32A C 10KA series SPN MCB incl. testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 48 | Providing and fixing of 32A 10KA C series TPN MCB | Providing and fixing of 32A 10KA C series TPN MCB incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 49 | Providing and fixing of Ammeter selector switch | Providing and fixing of Ammeter selector switch incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 50 | Providing and fixing of Voltmeter selector switch | Providing and fixing of Voltmeter selector switch incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 51 | Providing and fixing of Auto manual selector switch | Providing and fixing of Auto manual selector switch incl. testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 52 | Providing and fixing of VAF plus PF meter with 3No. CTs and its wiring | Providing and fixing of Multifunction VAF plus PF meter incl. CTs and its complete wiring, testing, commissioning etc. as reqd. | 12 | no | vijay@krishna | 30 |
| 53 | Repairing, servicing of radiator of EA set of 10KVA to 20KVA capacity | Repairing, servicing of radiator of EA set of 10KVA to 20KVA capacity incl. dismantling, shifting to workshop, cleaning, attending leakage, reinstallation, testing commissioning etc as reqd. | 20 | job | vijay@krishna | 30 |
| 54 | Repairing, servicing of radiator of EA set above 20KVA to 62.5KVA capacity | Repairing, servicing of radiator of EA set above 20 KVA to 62.5KVA capacity incl. dismantling, shifting to workshop, cleaning, attending leakage, reinstallation, testing commissioning etc as reqd. | 20 | job | vijay@krishna | 30 |
| 55 | Repairing, servicing of radiator of EA set of 75KVA to 125KVA capacity | Repairing, servicing of radiator of EA set of 75KVA to 125KVA capacity incl. dismantling, shifting to workshop, cleaning, attending leakage, reinstallation, testing commissioning etc as reqd. | 12 | job | vijay@krishna | 30 |
| 56 | Fuel Pump and Injectors caliberation | Servicing and caliberation of Fuel Pump and Injectors only from authorised dealer with test report etc as reqd | 24 | job | vijay@krishna | 30 |
| 57 | Repairing of self starter of EA set of 7.5KVA to 32.5KVA capacity | Repairing and servicing of self starter of EA set of 7.5KVA to 32.5KVA capacity incl. replacement of spares, winding, testing commissioning etc as reqd. | 24 | job | vijay@krishna | 30 |
| 58 | Repairing of self starter of EA set of 45KVA to 125KVA capacity | Repairing and servicing of self starter of EA set of 45KVA to 125KVA capacity incl. replacement of spares, winding, testing commissioning etc as reqd. | 24 | job | vijay@krishna | 30 |
| 59 | Repairing of charging alternator | Repairing and servicing of charging alternator incl. replacement of spares, winding, testing commissioning etc as reqd. | 20 | job | vijay@krishna | 30 |
| 60 | Repairing of high speed exhaust fan upto 450mm dia of EA set canopy | Repairing of high speed exhaust fan upto 450mm dia of EA set canopy incl. dismantling, shifting to workshop, rewinding, oiling, greasing, reinstallation, testing commissioning etc as reqd. | 24 | job | vijay@krishna | 30 |
| 61 | Repairing of EA set canopy door | Repairing of EA set canopy door incl. replacement of hinges, arranging welding or drilling machine, hardwares, manpower etc. complete as reqd. | 60 | job | vijay@krishna | 30 |
| 62 | Repairing of fuel tank of EA set | Repairing of fuel tank of EA set incl. dismantling, cleaning, attending leakage, reinstallation, testing commissioning etc as reqd. | 20 | job | vijay@krishna | 30 |
| 63 | Replacement of piston with guzzen pin, set of piston ring of 7.5 kVA to 20 kVA EA set | Replacement of piston with guzzen pin, set of piston ring of 7.5 kVA to 20 kVA EA set of various makes and model incl. manpower tools tackles, credit for old dismantelled material etc as reqd | 40 | job | vijay@krishna | 30 |
| 64 | Replacement of piston with guzzen pin, set of piston ring of 25 kVA to 63 kVA EA set | Replacement of piston with guzzen pin, set of piston ring of 25 kVA to 63 kVA EA set of various makes and model incl. manpower tools tackles, credit for old dismantelled material etc as reqd | 40 | job | vijay@krishna | 30 |
| 65 | Providing locking arrangement to canopy door | Providing locking arrangement to canopy door with fixing of MS sections or steel aldrop supply of pad lock with key set incl arranging welding or drilling machine, hardwares etc complete as reqd | 60 | job | vijay@krishna | 30 |
| 66 | Supplying and fixing of fully charged 1No. New 12V, 88AH lead acid semi maintenance free battery | Providing and fixing of fully charged 1No. New 12V, 88AH lead acid semi maintenance free battery having minimum warranty of 2 years incl. connection, testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 67 | Supplying and fixing of fully charged 1No. New 12V, 120AH lead acid semi maintenance free battery | Providing and fixing of fully charged 1No. New 12V, 120AH lead acid semi maintenance free battery having minimum warranty of 2 years incl. connection, testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 68 | Supplying and fixing of fully charged 1No. New 12V, 150AH lead acid semi maintenance free battery | Providing and fixing of fully charged 1No. New 12V, 150AH lead acid semi maintenance free battery having minimum warranty of 2 years incl. connection, testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 69 | Supplying and fixing of fully charged 1No. New 12V, 180AH lead acid semi maintenance free battery | Providing and fixing of fully charged 1No. New 12V, 180AH lead acid semi maintenance free battery having minimum warranty of 2 years incl. connection, testing, commissioning etc. as reqd. | 8 | no | vijay@krishna | 30 |
| 70 | Supplying and fixing of fully charged 1No. 12V, 88AH lead acid semi maintenance free battery against replacement | Providing and fixing of fully charged 1No. 12V, 88AH lead acid semi mtce free battery having minimum warranty of 2 years against replacement incl. connection, testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 71 | Supplying and fixing of fully charged 1No. New 12V, 120AH lead acid semi maintenance free battery against replacement | Providing and fixing of fully charged 1No. 12V, 120AH lead acid semi mtce free battery having minimum warranty of 2 years against replacement incl. connection, testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 72 | Supplying and fixing of fully charged 1No. New 12V, 150AH lead acid semi maintenance free battery against replacement | Providing and fixing of fully charged 1No. 12V, 150AH lead acid semi mtce free battery having minimum warranty of 2 years against replacement incl. connection, testing, commissioning etc. as reqd. | 20 | no | vijay@krishna | 30 |
| 73 | Supplying and fixing of fully charged 1No. New 12V, 180AH lead acid semi maintenance free battery against replacement | Providing and fixing of fully charged 1No. 12V, 180AH lead acid semi mtce free battery having minimum warranty of 2 years against replacement incl. connection, testing, commissioning etc. as reqd. | 8 | no | vijay@krishna | 30 |
| 74 | P and F of 32A, 240V, 2 Pole ON Load change over switch | P and F of 32A, 240V, 2 Pole, AC23 Heavy duty ON Load change over switch complete with sheet steel enclosure incl. operating mechanism, making connection etc. complete as reqd. | 20 | no | vijay@krishna | 30 |
| 75 | P and F of 63A, 415V, 4 Pole front handle operated ON Load change over switch | P and F of 63A, 415V, 4 Pole front handle operated AC23 Heavy duty ON Load change over switch complete with sheet steel enclosure incl. operating mechanism, making connection etc. complete as reqd. | 20 | no | vijay@krishna | 30 |
| 76 | P and F of 125A, 415V, 4 Pole front handle operated ON Load change over switch | P and F of 125A, 415V, 4 Pole front handle operated AC23 Heavy duty ON Load change over switch complete with sheet steel enclosure incl. operating mechanism, making connection etc. complete as reqd. | 8 | no | vijay@krishna | 30 |
| 77 | Dismantling of 7.5KVA to 15KVA canopy or room mounted EA set | Dismantling of old existing 7.5KVA to 15KVA canopy or room mounted EA set incl. disconnecting all cables, pipes, patties, arranging specialised manpower, tool plant etc complete as reqd. | 12 | job | vijay@krishna | 30 |
| 78 | Dismantling of 20KVA to 32.5KVA canopy or room mounted EA set | Dismantling of old existing 20KVA to 32.5KVA canopy or room mounted EA set incl. disconnecting all cables, pipes, patties, arranging specialised manpower, tool plant etc complete as reqd. | 12 | job | vijay@krishna | 30 |
| 79 | Dismantling of 45KVA to 62.5KVA canopy or room mounted EA set | Dismantling of old existing 45KVA to 62.5KVA canopy or room mounted EA set incl. disconnecting all cables, pipes, patties, arranging specialised manpower, tool plant etc complete as reqd. | 12 | job | vijay@krishna | 30 |
| 80 | Dismantling of 100KVA to 320KVA canopy or room mounted EA set | Dismantling of old existing 100KVA to 320KVA canopy or room mounted EA set incl. disconnecting all cables, pipes, patties, arranging specialised manpower, tool plant etc complete as reqd. | 8 | job | vijay@krishna | 30 |
| 81 | Transportation of old dismantled 7.5KVA to 32.5KVA EA set from 1KM to 30KM | Transportation of old dismantled 7.5KVA to 32.5KVA canopy or room mounted EA set from 1KM to 30KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 8 | job | vijay@krishna | 30 |
| 82 | Transportation of old dismantled 7.5KVA to 32.5KVA EA set from 31KM to 60KM | Transportation of old dismantled 7.5KVA to 32.5KVA canopy or room mounted EA set from 31KM to 60KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 8 | job | vijay@krishna | 30 |
| 83 | Transportation of old dismantled 7.5KVA to 32.5KVA EA set from 61KM to 120KM | Transportation of old dismantled 7.5KVA to 32.5KVA canopy or room mounted EA set from 61KM to 120KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 4 | job | vijay@krishna | 30 |
| 84 | Transportation of old dismantled 45KVA to 62.5KVA EA set from 1KM to 30KM | Transportation of old dismantled 45KVA to 62.5KVA canopy or room mounted EA set from 1KM to 30KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 4 | job | vijay@krishna | 30 |
| 85 | Transportation of old dismantled 45KVA to 62.5KVA EA set from 31KM to 60KM | Transportation of old dismantled 45KVA to 62.5KVA canopy or room mounted EA set from 31KM to 60KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 4 | job | vijay@krishna | 30 |
| 86 | Transportation of old dismantled 45KVA to 62.5KVA EA set from 61KM to 120KM | Transportation of old dismantled 45KVA to 62.5KVA canopy or room mounted EA set from 61KM to 120KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 4 | job | vijay@krishna | 30 |
| 87 | Transportation of old dismantled 100KVA to 320KVA EA set from 1KM to 30KM | Transportation of old dismantled 100KVA to 320KVA canopy or room mounted EA set from 1KM to 30KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 4 | job | vijay@krishna | 30 |
| 88 | Transportation of old dismantled 100KVA to 320KVA EA set from 31KM to 60KM | Transportation of old dismantled 100KVA to 320KVA canopy or room mounted EA set from 31KM to 60KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 4 | job | vijay@krishna | 30 |
| 89 | Transportation of old dismantled 100KVA to 320KVA EA set from 61KM to 120KM | Transportation of old dismantled 100KVA to 320KVA canopy or room mounted EA set from 61KM to 120KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 4 | job | vijay@krishna | 30 |
| 90 | Transportation of old dismantled 100KVA to 320KVA EA set from 121KM to 200KM | Transportation of old dismantled 100KVA to 320KVA canopy or room mounted EA set from 121KM to 200KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 4 | job | vijay@krishna | 30 |
| 91 | Transportation of old dismantled 100KVA to 320KVA EA set from 201KM to 350KM | Transportation of old dismantled 100KVA to 320KVA canopy or room mounted EA set from 201KM to 350KM aw all acc. incl. hiring vehicle, specialised manpower, loading, unloading etc. as required. | 4 | job | vijay@krishna | 30 |
| 92 | Providing arranging hydra or crane service for lifting of EA sets | Providing arranging hydra or crane service for lifting of EA sets incl. all acc. and placing at directed site location etc. as reqd. This item is for other than Item No. 81 to 91 above, if reqd | 20 | job | vijay@krishna | 30 |
| 93 | ITC of 7.5KVA to 20KVA EA set | ITC of 7.5KVA to 20KVA EA set, on existing foundation incl. connection of all cables, earthing, fuel and exhaust pipe, silencer, testing on load for 1HRs incl. diesel supply etc. complete as reqd | 12 | job | vijay@krishna | 30 |
| 94 | ITC of 25KVA to 32.5KVA EA set | ITC of 25KVA to 32.5KVA EA set, on existing foundation incl. connection of all cables, earthing, fuel and exhaust pipe, silencer, testing on load for 1HRs incl. diesel supply etc. complete as reqd | 12 | job | vijay@krishna | 30 |
| 95 | ITC of 45KVA to 62.5KVA EA set | ITC of 45KVA to 62.5KVA EA set, on existing foundation incl. connection of all cables, earthing, fuel and exhaust pipe, silencer, testing on load for 1HRs incl. diesel supply etc. complete as reqd | 12 | job | vijay@krishna | 30 |
| 96 | ITC of 100KVA to 320KVA EA set | ITC of 100KVA to 320KVA EA set, on existing foundation incl. connection of all cables, earthing, fuel and exhaust pipe, silencer, testing on load for 1HRs incl. diesel supply etc. complete as reqd | 8 | job | vijay@krishna | 30 |
| 97 | Providing and fixing of 50MM dia C Class M.S. exhaust pipe | Providing and fixing of 50MM dia C Class M.S. exhaust pipe to existing EA set exhaust line incl. flanges, nut bolts, tool plant, alignment, tightening of all connection etc. as reqd. | 20 | meter | vijay@krishna | 30 |
| 98 | Providing and fixing of 75MM dia C Class M.S. exhaust pipe | Providing and fixing of 75MM dia C Class M.S. exhaust pipe to existing EA set exhaust line incl. flanges, nut bolts, tool plant, alignment, tightening of all connection etc. as reqd. | 12 | meter | vijay@krishna | 30 |
| 99 | Providing and fixing of 100MM dia C Class M.S. exhaust pipe | Providing and fixing of 100MM dia C Class M.S. exhaust pipe to existing EA set exhaust line incl. flanges, nut bolts, tool plant, alignment, tightening of all connection etc. as reqd. | 12 | meter | vijay@krishna | 30 |
| 100 | P and L PCC foundation in ratio 1 as 2 as 4, i.e. 1 Cement, 2 coarse sand and 4 graded stone metal of 20mm NS | Providing and laying PCC foundation in ratio 1 as 2 as 4, i.e. 1 Cement, 2 coarse sand and 4 graded stone metal of 20mm NS incl. reqd civil work like shuttering, plastering, curing etc. as reqd. | 12 | cubic meter | vijay@krishna | 30 |
| 101 | Earthing with G.I. earth plate 600mm X 600mm X 6mm thick | Earthing with G.I. earth plate 600mm X 600mm X 6mm thick incl. acc. and providing masonry encl. with cover plate having locking, watering pipe of 2.7mtr long etc. with charcoal, salt etc. as reqd. | 12 | set | vijay@krishna | 30 |
| 102 | P and L earth connection with 6SWG dia G.I. Wire in 15mm dia G.I. pipe | Providing and laying earth connection from earth electrode with 6SWG dia G.I. Wire in 15mm dia G.I. pipe from earth electrode incl. connection with G.I. thimble excavation and refilling etc. as reqd. | 60 | meter | vijay@krishna | 30 |
| 103 | P and F 25mm X 5mm G.I. strip on surface or in recess | Providing and fixing 25mm X 5mm G.I. strip on surface or in recess for connections etc. as required. | 60 | meter | vijay@krishna | 30 |
| 104 | Supplying of 3.5 core 150 Sq.mm. size ISI mark aluminium conductor armoured cable | Supplying of 3.5 core 150 Sq.mm. size PVC insulated and PVC sheathed or XLPE power cable of 1.1KV grade, ISI mark aluminium conductor armoured cable etc. as reqd. | 40 | meter | vijay@krishna | 30 |
| 105 | Supplying of 3.5 core 120 Sq.mm. size ISI mark aluminium conductor armoured cable | Supplying of 3.5 core 120 Sq.mm. size PVC insulated and PVC sheathed or XLPE power cable of 1.1KV grade, ISI mark aluminium conductor armoured cable etc. as reqd. | 40 | meter | vijay@krishna | 30 |
| 106 | Supplying of 3.5 core 95 Sq.mm. size ISI mark aluminium conductor armoured cable | Supplying of 3.5 core 95 Sq.mm. size PVC insulated and PVC sheathed or XLPE power cable of 1.1KV grade, ISI mark aluminium conductor armoured cable etc. as reqd. | 40 | meter | vijay@krishna | 30 |
| 107 | Supplying of 3.5 core 70 Sq.mm. size ISI mark aluminium conductor armoured cable | Supplying of 3.5 core 70 Sq.mm. size PVC insulated and PVC sheathed or XLPE power cable of 1.1KV grade, ISI mark aluminium conductor armoured cable etc. as reqd. | 40 | meter | vijay@krishna | 30 |
| 108 | Supplying of 3.5 core 50 Sq.mm. size ISI mark aluminium conductor armoured cable | Supplying of 3.5 core 50 Sq.mm. size PVC insulated and PVC sheathed or XLPE power cable of 1.1KV grade, ISI mark aluminium conductor armoured cable etc. as reqd. | 40 | meter | vijay@krishna | 30 |
| 109 | Supplying of 3.5 core 35 Sq.mm. size ISI mark aluminium conductor armoured cable | Supplying of 3.5 core 35 Sq.mm. size PVC insulated and PVC sheathed or XLPE power cable of 1.1KV grade, ISI mark aluminium conductor armoured cable etc. as reqd. | 40 | meter | vijay@krishna | 30 |
| 110 | Supplying of 3.5 core 25 Sq.mm. size ISI mark aluminium conductor armoured cable | Supplying of 3.5 core 25 Sq.mm. size PVC insulated and PVC sheathed or XLPE power cable of 1.1KV grade, ISI mark aluminium conductor armoured cable etc. as reqd. | 40 | meter | vijay@krishna | 30 |
| 111 | Supplying of 2 core 25 Sq.mm. size ISI mark aluminium conductor armoured cable | Supplying of 2 core 25 Sq.mm. size PVC insulated and PVC sheathed or XLPE power cable of 1.1KV grade, ISI mark aluminium conductor armoured cable etc. as reqd. | 40 | meter | vijay@krishna | 30 |
| 112 | Laying of cable upto 35Sqmm size direct in ground incl. excavation and refill trench | Laying of PVC insu and sheathed or XLPE cable of 1.1KV grade upto 35Sqmm size direct in ground incl excavation and refill trench etc as reqd but without sand cushion and protective cover | 40 | meter | vijay@krishna | 30 |
| 113 | Laying of cable above 35Sqmm to 95 Sqmm size direct in ground incl. excavation and refill trench | Laying of PVC insu and sheathed or XLPE cable of 1.1KV grade above 35Sqmm to 95Sqmm size direct in ground incl excavation and refill trench etc as reqd but without sand cushion and protective cover | 20 | meter | vijay@krishna | 30 |
| 114 | Laying of cable above 95Sqmm to 185 Sqmm size direct in ground incl. excavation and refill trench | Laying of PVC insu and sheathed or XLPE cable of 1.1KV grade above 95Sqmm to 185Sqmm size direct in ground incl excavation and refill trench etc as reqd but without sand cushion and protective cover | 20 | meter | vijay@krishna | 30 |
| 115 | Laying of cable upto 35Sqmm size in existing RCC or HUME or METAL pipe | Laying of PVC insu and sheathed or XLPE cable of 1.1KV grade upto 35Sqmm size in existing RCC or HUME or METAL pipe etc as reqd | 20 | meter | vijay@krishna | 30 |
| 116 | Laying of cable above 35Sqmm to 95Sqmm size in existing RCC or HUME or METAL pipe | Laying of PVC insu and sheathed or XLPE cable of 1.1KV grade above 35Sqmm to 95Sqmm size in existing RCC or HUME or METAL pipe etc as reqd | 20 | meter | vijay@krishna | 30 |
| 117 | Laying of cable above 95Sqmm to 185Sqmm size in existing RCC or HUME or METAL pipe | Laying of PVC insu and sheathed or XLPE cable of 1.1KV grade above 95Sqmm to 185Sqmm size in existing RCC or HUME or METAL pipe etc as reqd | 20 | meter | vijay@krishna | 30 |
| 118 | Laying of cable upto 35Sqmm size in existing masonry open duct | Laying of PVC insu and sheathed or XLPE cable of 1.1KV grade upto 35Sqmm size in existing masonry open duct etc as reqd | 20 | meter | vijay@krishna | 30 |
| 119 | Laying of cable above 35Sqmm to 95Sqmm size in existing masonry open duct | Laying of PVC insu and sheathed or XLPE cable of 1.1KV grade above 35Sqmm to 95Sqmm size in existing masonry open duct etc as reqd | 20 | meter | vijay@krishna | 30 |
| 120 | Laying of cable above 95Sqmm to 185Sqmm size in existing masonry open duct | Laying of PVC insu and sheathed or XLPE cable of 1.1KV grade above 95Sqmm to 185Sqmm size in existing masonry open duct etc as reqd | 20 | meter | vijay@krishna | 30 |
| 121 | Laying and fixing of cable upto 35sqmm size on wall surface | Laying and fixing of PVC insu and sheathed or XLPE cable of 1.1KV grade upto 35sqmm size on wall surface clamped with 1mm thick saddle etc as reqd | 60 | meter | vijay@krishna | 30 |
| 122 | Laying and fixing of cable above 35Sqmm to 95Sqmm size on wall surface | Laying and fixing of PVC insu and sheathed or XLPE cable of 1.1KV grade above 35Sqmm to 95Sqmm size on wall surface clamped with 25x3mm MS flat clamp etc as reqd | 40 | meter | vijay@krishna | 30 |
| 123 | Laying and fixing of cable above 95Sqmm to 185Sqmm size on wall surface | Laying and fixing of PVC insu and sheathed or XLPE cable of 1.1KV grade above 95Sqmm to 185Sqmm size on wall surface clamped with 25 or 40x3mm MS flat clamp etc as reqd | 20 | meter | vijay@krishna | 30 |
| 124 | S and M end termination of 2 X 25sqmm aluminium conductor cable | S and M end termination with brass compression gland and aluminium lugs for 2 X 25sqmm size of PVC insu and sheathed or XLPE aluminium conductor cable of 1.1KV grade etc as reqd | 8 | no | vijay@krishna | 30 |
| 125 | S and M end termination of 3.5 X 25sqmm aluminium conductor cable | S and M end termination with brass compression gland and aluminium lugs for 3.5 X 25sqmm size of PVC insu and sheathed or XLPE aluminium conductor cable of 1.1KV grade etc as reqd | 8 | no | vijay@krishna | 30 |
| 126 | S and M end termination of 3.5 X 35sqmm aluminium conductor cable | S and M end termination with brass compression gland and aluminium lugs for 3.5 X 35sqmm size of PVC insu and sheathed or XLPE aluminium conductor cable of 1.1KV grade etc as reqd | 8 | no | vijay@krishna | 30 |
| 127 | S and M end termination of 3.5 X 50sqmm aluminium conductor cable | S and M end termination with brass compression gland and aluminium lugs for 3.5 X 50sqmm size of PVC insu and sheathed or XLPE aluminium conductor cable of 1.1KV grade etc as reqd | 8 | no | vijay@krishna | 30 |
| 128 | S and M end termination of 3.5 X 70sqmm aluminium conductor cable | S and M end termination with brass compression gland and aluminium lugs for 3.5 X 70sqmm size of PVC insu and sheathed or XLPE aluminium conductor cable of 1.1KV grade etc as reqd | 8 | no | vijay@krishna | 30 |
| 129 | S and M end termination of 3.5 X 95sqmm aluminium conductor cable | S and M end termination with brass compression gland and aluminium lugs for 3.5 X 95sqmm size of PVC insu and sheathed or XLPE aluminium conductor cable of 1.1KV grade etc as reqd | 8 | no | vijay@krishna | 30 |
| 130 | S and M end termination of 3.5 X 120sqmm aluminium conductor cable | S and M end termination with brass compression gland and aluminium lugs for 3.5 X 120sqmm size of PVC insu and sheathed or XLPE aluminium conductor cable of 1.1KV grade etc as reqd | 8 | no | vijay@krishna | 30 |
| 131 | S and M end termination of 3.5 X 150sqmm aluminium conductor cable | S and M end termination with brass compression gland and aluminium lugs for 3.5 X 150sqmm size of PVC insu and sheathed or XLPE aluminium conductor cable of 1.1KV grade etc as reqd | 8 | no | vijay@krishna | 30 |
| 132 | S and L of 6sqmm. multistrand copper conductor flexible cable incl. copper lugs | Supplying and laying of 6sqmm. multistrand copper conductor flexible ISI mark cable for neutral earth connection incl. providing and fixing copper lugs etc as reqd | 60 | meter | vijay@krishna | 30 |
| 133 | P and L of 8SWG dia G.I. wire on surface or in recess | Providing and laying of 8SWG dia G.I. wire on surface or in recess for loop earthing etc as reqd | 600 | meter | vijay@krishna | 30 |
| 134 | P and L of 40mm dia medium class G.I. pipe in ground | Providing and laying of 40mm dia medium class G.I. pipe in ground complete with G.I. fittings incl trenching and refilling etc as reqd | 20 | meter | vijay@krishna | 30 |
| 135 | P and L of 100mm dia medium class G.I. pipe in ground | Providing and laying 100mm dia medium class G.I. pipe in ground complete with G.I. fittings incl trenching and refilling etc as reqd | 12 | meter | vijay@krishna | 30 |
Extended Deadline
10-Jun-2025, 11:00 am
Opening Date
10-Jun-2025, 11:30 am
Start
26-Jun-2025, 5:00 pm
End
28-Jun-2025, 11:00 am
Duration: 42 hours
Reverse Auction Document
✅ RA concluded. Check financial results for final rankings.
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | Arfa Electricals & Engineering Works Under PMA | - | 27-05-2025 15:11:40 | Qualified |
| 2 | POWER CONTROL Under PMA | - | 04-06-2025 12:03:31 | Qualified |
| 3 | POWERTECH ENGINEERS Under PMA | - | 31-05-2025 17:31:02 | Qualified |
| 4 | UNITED GENSETS PRIVATE LIMITED Under PMA | - | 07-06-2025 15:14:23 | Qualified |
| 5 | Vishal Contract works Under PMA | - | 04-06-2025 18:11:15 | Qualified |
Key insights about MAHARASHTRA tender market
The eligibility requirements include being a registered entity with verifiable experience in servicing Diesel Generator sets. Additionally, bidders must comply with all guidelines provided by the Department of Telecommunications.
Bidders must present relevant operational certificates that demonstrate compliance with industry standards. This includes certifications related to quality management, technical capabilities, and any mandatory regulatory certifications that apply to the servicing of DG sets.
The registration process involves signing up on the designated tender platform. Bidders must provide their organizational details, including registration number, relevant certifications, and previous work experience related to similar projects.
All tenders must be submitted in specified document formats such as PDF and Word documents. Bidders should ensure that all documents are clearly labeled and meet the formatting requirements outlined in the tender specifications.
Payment terms include details on the schedule of payments, percentage of upfront payments, and payment upon completion of specific milestones throughout the project duration. Bidders must provide a comprehensive financial proposal reflecting these payment terms.
Sign up now to access all documents
Main Document
OTHER
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS