TenderDekho Logo
GEM

Open Tender for Surgical Operating ENT Microscope in BILASPUR, CHHATTISGARH

Bid Publish Date

20-Feb-2026, 6:27 pm

Bid End Date

13-Mar-2026, 2:00 pm

EMD

₹70,000

Progress

Issue20-Feb-2026, 6:27 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 5

Chhattisgarh Medical Services Corporation Limited has released a public tender for Surgical Operating ENT Microscope (Q2) in BILASPUR, CHHATTISGARH. Quantity: 1. Submission Deadline: 13-03-2026 14: 00: 00. Download documents and apply online.

Documents 4

GeM-Bidding-9015511.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Surgical Operating ENT Microscope

East Coast Railway

VISAKHAPATNAM, ANDHRA PRADESH

Posted: 19 December 2025
Closed: 29 December 2025
GEM

Surgical Operating ENT Microscope

Durgapur Steel Plant

Posted: 18 November 2024
Closed: 2 December 2024
GEM

Surgical Operating ENT Microscope

Nmdc Limited

BELLARY, KARNATAKA

Posted: 9 August 2025
Closed: 6 September 2025
GEM

Surgical Operating ENT Microscope

Pdu Civil Hospital Rajkot

RAJKOT, GUJARAT

Posted: 12 March 2025
Closed: 22 March 2025
GEM

Surgical Operating ENT Microscope

Directorate Of Medical Education And Training

SIDDHARTHNAGAR, UTTAR PRADESH

Posted: 24 June 2025
Closed: 17 July 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Standards Confirmity to Manufactures Certification ISO 9001 & ISO 13485, ICMED 9001 & 13485
Performance Parameters Magnification (5 Step) 0.4 X, 0.6 X, 1.0 X, 1.2 X or 1.6 X, 2.5 X, >2.5 X
Performance Parameters Manually adjustable magnification changer 1.6 X, 2.0 X, 2.5 X, 1.0 X,1.6 X, 2.5 X, > 2.5 X
Performance Parameters Resolution of camera in pixels 700 x 450 px, 1920 x 1080 px, 3840 x 2160 px
Performance Parameters Wide field push in eye pieces 10 X, 12.5 X, 16 X
Performance Parameters Provision of integrated eye cups Yes, No
Performance Parameters Type of Binocular tube Straight, Tilt, Inclinable 45 degree viewing, Inclinable 60 degree viewing, 0 degree to 240 degree Inclinable, 0 degree to 180 degree inclinable
Performance Parameters Provision of built in IR Filter Yes, No
Performance Parameters Provision of built in UR Filter Yes, No
Performance Parameters Adjustable friction of all joints Yes, No
Performance Parameters Provision of integerated handles for positioning of microscope Yes, No
Performance Parameters Focal length of Binocular tube in mm 170 mm, 200 mm, 300 mm, 400 mm, 500 mm
Performance Parameters Type of monitor (medical grade) LED, LCD
Performance Parameters Monitor resolution 700 x 450 px, 1920 x 1080 px, 3840 x 2160 px
Performance Parameters Size of monitor screen in inch 17, 21, 27
Performance Parameters Availability of CCD digital camera attachment Yes, No
Performance Parameters Facility of video recording facility with video trolley with isolating transformer Yes (capacity 1 TB with 4.5 inch or more touch screen), Yes (capacity 500 GB with 4.5 inch or more touch screen), No
Performance Parameters Availability of dust cover for microscope Yes, No
Dimensional Parameters Objective lens in mm 200 mm, 250 mm, 300 mm, 400 mm, 415 mm
Dimensional Parameters Field of view in mm 52 mm to 8 mm, 112 mm to 11 mm, 15mm to 150 mm
Dimensional Parameters Illumination Halogen (with similar back up integrated within the module), Xenon (with similar back up integrated within the module), LED (with no backup)
Power Requirements Light source LED, xenon lamp integrated, co axial illumination by a light source having halogen bulb (12V/100W)
Power Requirements Facility of stand for bulb change Yes, No
Power Requirements Power Back Up Provided Online UPS System, 2 KVA, Not provided
Power Requirements Back up time 15 Minutes, NA if back up not provided
Power Requirements Facility of spike protection for 30 minutes Yes, No
Additional Parameters On screen display to be provided Yes, No
Additional Parameters ON Screen display showing total magnification, scale projection, working distance etc Yes, NA if no screen display is provided
Additional Parameters Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 3, 5, 1, 2, 4
Reports Number of installations in Central /State/PSU Govt Hospitals 0, <3, >3

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC)

9

Additional Doc 3 (Requested in ATC)

10

Additional Doc 4 (Requested in ATC)

11

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

12

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer