All India Institute Of Medical Sciences (aiims) has released a public tender for Echo Cardiography Scanning Machine (V2) (Q2). Quantity: 1. Submission Deadline: 07-03-2026 15: 00: 00. Download documents and apply online.
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
VALSAD, GUJARAT
Indian Army
EAST SIKKIM, SIKKIM
Indian Army
CHAMPAWAT, UTTARAKHAND
Union Bank Of India (ubi)
WEST GODAVARI, ANDHRA PRADESH
N/a
KRISHNAGIRI, TAMIL NADU
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Types of Probes & Features | Cardiac and Vascular Probes Configuration | TTE Phased Array, TTE Matrix Array, TEE Phased Array, TEE Matrix Array, Linear Probe |
| Types of Probes & Features | TTE(Transthoracic) Probe Type | Adult, Pediatric, Neonatal |
| Types of Probes & Features | TEE Adult Probe biplane and Multiplane frequency, in MHz | 2 to 7.5 MHz (±2) |
| Types of Probes & Features | TEE Pediatric Probe Required | Yes |
| Types of Probes & Features | TEE Pediatric Probe frequency, in MHz | 3 to 8 MHz (±2) |
| Types of Probes & Features | Linear Probe for linear/ vascular applications required | Yes |
| Types of Probes & Features | Adult/Pediatric Linear probe frequency in MHz | 5 to 14 MHz (±2) |
| Types of Probes & Features | No of Adult TTE Probes Required | 1 |
| Types of Probes & Features | No of Pediatric TTE Probes Required | 1 |
| Types of Probes & Features | No of Neonatal TTE Probes Required | 1 |
| Types of Probes & Features | No of Adult TEE Probes Required | 1 |
| Types of Probes & Features | No of Pediatric TEE Probes Required | 1 |
| Types of Probes & Features | No of Pediatric 3D/4D TEE Probes Required | 1 |
| Types of Probes & Features | No of Neonatal TEE Probes Required | 1, NA |
| Types of Probes & Features | No of Adult/pediatric Linear Probes supplied | 1 |
| Types of Probes & Features | Dedicated 3D/4D volume imaging for cardiology TTE ad TEE | Yes |
| Types of Probes & Features | Live 3 D imaging in color doppler system | Yes |
| Types of Probes & Features | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes |
| Types of Probes & Features | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes |
| Types of Probes & Features | Application software | Adult, Pediatric, Neonatal, Vascular applications and Transesophagal applications |
| Types of Probes & Features | Cine Loop Features | Yes |
| Types of Probes & Features | Frame grabber facility for post analysis | Yes |
| Types of Probes & Features | Facility of Various maps for pre and post processing | Yes |
| Types of Probes & Features | ECG trigger facility | Yes |
| Types of Probes & Features | User defined Preset | Yes |
| Types of Probes & Features | Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography | Yes |
| Types of Probes & Features | Number of transducer/probe ports | 4 |
| Scan Modes and Performance Parameters | Cardiac 3-D freehand Option | Yes |
| Scan Modes and Performance Parameters | Cardiac 3D/4D automatic Option | Yes |
| Scan Modes and Performance Parameters | Contrast Harmonic/Agent Imaging with angio mode | Yes |
| Scan Modes and Performance Parameters | Provision of Harmonic imaging in TTE, TEE and Linear Probes | Yes |
| Scan Modes and Performance Parameters | Color Doppler 3-D/4-D option | Yes |
| Scan Modes and Performance Parameters | Power Dopple 3-D/4-D option | Yes |
| Scan Modes and Performance Parameters | Contrast-enhanced ultrasound (CEUS) option | Yes |
| Scan Modes and Performance Parameters | Tissue synchronization, tissue velocity | Yes |
| Scan Modes and Performance Parameters | Cardiac Shear wave elastography | Yes |
| Scan Modes and Performance Parameters | Cardiac compression elastography | Yes |
| Scan Modes and Performance Parameters | Probes supplied shall be in latest generation bandwidth | Yes |
| Scan Modes and Performance Parameters | Provision for higher sensitivity for low frequency doppler in all probes | Yes |
| Scan Modes and Performance Parameters | Latest generation Electronic Phased/sector array Colour Doppler system | Yes |
| Scan Modes and Performance Parameters | Number of Channels in color doppler system | 5000000 or more (if channels are being designated as digital channels) |
| Scan Modes and Performance Parameters | System should be capable of generating real time live 3- D images | Yes, Yes with MV No Analysis |
| Scan Modes and Performance Parameters | Provision of Echocardiographic strain and strain-rate imaging with 2 D imaging | Yes |
| Scan Modes and Performance Parameters | Provision of Echocardiographic strain and strain-rate imaging with 3 D imaging | Yes |
| Image display and processing | DICOM 3 Compliant | Yes |
| Image display and processing | Automated B-mode (2-D) image | Yes |
| Image display and processing | Automated CDI image optimization | Yes |
| Image display and processing | Automated PW Doppler image optimization | Yes |
| Image display and processing | Touch Screen | Yes |
| Image display and processing | Monitor display size, cm (in) | 21 Inch(±1) Or higher |
| Image display and processing | Split screen | Twin View and Live Quad Screen |
| Image display and processing | Single/dual monitors | Dual (image display on touch panel) |
| Image display and processing | DIGITAL IMAGE STORAGE | Yes |
| Image display and processing | Speckle-tracking strain and strain rate | Yes |
| Image display and processing | Analysis and calculation packages | 2-D wall motion tracking, 3-D wall motion tracking, Cardiac, Mitral valve analysis, User-programmable calculations, No |
| Image display and processing | Flash Memory | Yes |
| Image display and processing | USB connector | Yes |
| Image display and processing | Type of printer provided with the echo cardio machine | Themal Printer |
| Image display and processing | Provision of PC with echo cardio gram machine | Yes |
| Image display and processing | Type of processor in PC | i7 or Latest |
| Image display and processing | RAM capacity of PC in GB (hint: In caase PC not provided put zero) | >=4 |
| Image display and processing | Processor speed in GHZ | >=3 |
| Image display and processing | Conectivity between Echo cardiogram and PC | Through IMS/Equivalent Software |
| Image display and processing | PC with all software inclusive interfaced with echocardiograph machine | Yes |
| Image display and processing | Inkjet printer provided with computer for reporting | Yes |
| Image display and processing | Glossy Colour Print Paper supplied | 500 sheets |
| Image display and processing | ECG Cable | 2 |
| Image display and processing | Echo cardiography sytem to be DICOM Ready | Yes |
| Image display and processing | Dicom Interfacability to HIS | Yes |
| Image display and processing | Dicom Interfacability Dicom to PACS | Yes |
| Image display and processing | Interfacability Dicom to RIS | Yes |
| Image display and processing | Echo Cardiography sytem supplied should be upgradable to next generation system on site | Yes |
| Power Requriments | Resettable over current breaker shall be fitted for protection | Yes |
| Power Requriments | Power bakup | UPS |
| Power Requriments | Back up time in minutes | 30, 60, 90, 120 Or higher |
| MISCELLANEOUS PARAMETERS | Supplier to perform installation, safety and operation checks before handover | Yes |
| MISCELLANEOUS PARAMETERS | Training of users in operation and basic maintenance shall be provided | Yes |
| MISCELLANEOUS PARAMETERS | Contact details of manufacturer, supplier and local service agent to be provided | Yes |
| MISCELLANEOUS PARAMETERS | Certificate of calibration from the manufacturer | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Army
📍 UDHAMPUR, JAMMU & KASHMIR
Directorate Of Technical Education And Training
Directorate Of Employment & Training
📍 NAVSARI, GUJARAT
E-municipalities - Eservices To Citizens And Employees Of Urban Local Bodies Of Uttar Pradesh
Hll Infra Tech Services Limited
Sign up now to access all documents
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS