Bid Publish Date
19-Aug-2026, 12:39 pm
Bid End Date
07-Sep-2026, 11:00 am
EMD
₹18,951
Location
Progress
Nuclear Power Corporation Of India Limited has released a public tender for Transformer Winding Resistance Meter (Q3) in UTTARA KANNADA, KARNATAKA. Quantity: 1. Submission Deadline: 07-09-2026 11: 00: 00. Download documents and apply online.
Quantity
1
Bid Type
Two Packet Bid
Bid Validity
120 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
7 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Transformer Winding Resistance Meter (Q3)
Advisory Bank
State Bank of India
Payment Timelines
Payments shall be made to the Seller within 10 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
90
Delivery Locations
1
Delivery Cities
Uttara Kannada
Delivery Pincodes
581400
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Santosh Kulkarni | 581400,Plant Site, Kaiga Generating Station, PO: Kaiga | Uttara Kannada | Karnataka | 581400 | 1 | 90 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
07-Sep-2026, 5:30 am
Opening Date
07-Sep-2026, 6:00 am
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| General Parameter | No lead compensation shall be required for the measurement | Yes |
| General Parameter | Number of measuring channel | 6 |
| Technical Specification | Resolution(0,02%FS),U? | 1 μΩ up to 1000 μΩ range, 0.02% of FS above 500 μΩ range |
| Technical Specification | Open circuit voltage | >/=50 |
| Technical Specification | Accuracy,+/-5 count | 0.5 |
| Technical Specification | Test Current,ampere(DC) | 25 amp DC Continuous |
| Technical Specification | Display with backlight viewable in bright sunlight | Digital LCD display |
| Technical Specification | Range(ohms) | 0 to 2000ohm auto reading |
| Performance parameter | The equipement shall have demagnetization circuitry | Yes |
| Performance parameter | The test kit shall be able to withstand inductive kicks from transformer winding and shall be capable of working in inductive atmosphere of 765/400kV Substation | Yes |
| Electrical Parameter | Power supply,+/-10% | 230.0 |
| Electrical Parameter | Frequency,+/-5% | 50.0 |
| Additional Parameter | The kit shall be compatible EMI/EMC safety standard as per IEC | Yes |
| Additional Parameter | Accessories | Complete set of test lid leads (min 20 m, Combination plugs clamps, Connectors, Power supply cables, Original hard carrying case, Manuals(both soft and hard copy), Other |
| Additional Parameter | Calibraton Certificate not older than 2 months from date of supply | Yes |
| Additional Parameter | The complete equipment along with the complete accessories must be designed/engineer by OEM | Yes |
| Additional Parameter | Services after Sale Bidder will have to submit the documentary evidences of having established mechanism for prompt services in India as and when required by Powergrid. Bidder need to submit their organization service chart along with bid | Yes |
| Shelf life | Warranty | 1.0 |
| Test Report | Test Report To Be Submitted To The Buyer On Demand | Yes |
| Test Report | Availability of Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification | Yes |