Bid Publish Date
21-Aug-2026, 5:41 pm
Bid End Date
03-Sep-2026, 6:00 pm
EMD
₹30,000
Location
Progress
Tamil Nadu Cooperative Milk Producers Federation L has released a public tender for Bulk Milk Cooler Unit (Q2) in CUDDALORE, TAMIL NADU. Quantity: 2. Submission Deadline: 03-09-2026 18: 00: 00. Download documents and apply online.
Quantity
2
Bid Type
Two Packet Bid
Bid Validity
30 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
No
MSE Purchase Preference
No
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
15
OEM Avg. Turnover
50
Past Performance
80 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Bulk Milk Cooler Unit (Q2)
Advisory Bank
State Bank of India
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
160
Delivery Locations
1
Delivery Cities
Cuddalore
Delivery Pincodes
608702
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Anitha Arockiyajose | 608702,Virudhachalam Main ROad, Sethiatope & Post, Bhuvanagiri Taluk, CUddalore | Cuddalore | Tamil Nadu | 608702 | 2 | 160 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
03-Sep-2026, 12:30 pm
Opening Date
03-Sep-2026, 1:00 pm
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| Bulk Milk Cooler Tank | CIP Piping | For Closed type tank facilities for cleaning in place shall be provided which include CIP spray balls & SS piping from balance tank through milk pump to BMC and back to balance tank |
| Bulk Milk Cooler Tank | Number of Agitators | 1 |
| Bulk Milk Cooler Tank | Thickness of Inner shell of tank | 2.0 |
| Bulk Milk Cooler Tank | Certificaton | As Per ISO 5708 Type 2A II (Latest Version) Stndard |
| Bulk Milk Cooler Tank | Thickness of Outer shell of tank | 2.0 |
| Bulk Milk Cooler Tank | Bulk Milk Cooler Tank Rated Capacity | 5000, 10000 Or higher |
| Bulk Milk Cooler Tank | Number of SS 304 Hooks for Hose Pipe | 6 |
| Bulk Milk Cooler Tank | Tank Type | Closed Type |
| Bulk Milk Cooler Tank | CIP Facility | CIP Cleaning by spray balls using pump and balance tank for closed type tanks |
| Bulk Milk Cooler Tank | Milk Inlet System | Pump Feed System |
| Bulk Milk Cooler Tank | Bulk Milk Cooler Tank Gross Capacity | 5500, 11000 Or higher |
| Bulk Milk Cooler Tank | Auto CIP System for Bulk Milk Cooling Tank | Pre-Programed Automatic CIP system for claening of Milk Cooling Tank |
| Bulk Milk Cooler Tank | Top cover opening limit switch for open type tank | NA |
| Milk Tank Control Panel | Display Type | LED |
| Main Contol Panel with Servo Voltage Stabilizer | Phase | Three Phase |
| Main Contol Panel with Servo Voltage Stabilizer | Voltage range | 300 to 500 V |
| Refrigeration Unit | Type of Refrigerant | R22 or CFC free refrigerant |
| Refrigeration Unit | Number of Compressor | 2 |
| Milk Pump | Pump inlet/outlet | 38 x 38mm with SMS unions |
| Milk Pump | Head in mwc | 15 MWC |
| Milk Pump | Flow Rate | 5000 LPH |
| Food grade tanker loading/unloading hose pipe | Size | 38.0 |
| Water Handling System for Bulk Milk Cooler | Piping Material (ISI Marked) | UPVC |
| Water Handling System for Bulk Milk Cooler | Capacity | 0.5 HP, 10 mwc |
| Hot Water Generator - Heat Recovery Unit | Quantity | 1, 2 Or higher |
| Fire Extinguisher | ABC stored pressure type fire extinguisher 1kg each | 3 |
| Diesel Generator (DG) Set | DG Set Capacity, kVA | 25 |
| Diesel Generator (DG) Set | No of Phase | Three Phase |
| Diesel Generator (DG) Set | Alternator IP Rating | IP 23 |
| Diesel Generator (DG) Set | IP Rating of Control Panel | IP 53 |
| Data Logging System | UPS | 7AH Battery with 8 Hours Backup |
| Data Logging System | GRID Sensor | LDR based and isolated to protect the reverse current flow. |
| Data Logging System | Volume Sensor | Pressure Based, EHEDG compliant, Food Grade |
| Data Logging System | Display | 7 Segment LED |
| Data Logging System | DG Sensor | LDR based |
| Data Logging System | Temperature Sensor | 0-70 Degree Celciuos, Housing SS 304 |
| Data Logging System | Compressor Sensor | Current transmitting sensors |
| Data Logging System | Panel Board | Metal Powder Coated/Height 50CM and Width 50 CM and Inner width 12.5 CM |
| Installation, commissioning, trial runs and putting the BMCU in operation | Interconnecting piping for the entire plant | SS 304 piping 38 mm diameter, 1.6 mm thick |