Satara District Panchayats Off-Grid Solar PV Power Plant Tender 2025 – PV Module & PCU Standards
Satara District Panchayats
SATARA, MAHARASHTRA
Bid Publish Date
07-Jan-2026, 2:45 pm
Bid End Date
07-Feb-2026, 3:00 pm
EMD
₹10,200
Location
Progress
Quantity
2
Bid Type
Two Packet Bid
A tender has been published for Uranium Corporation Of India Limited Wind Solar PV Hybrid System - Off grid (Q2) in CUDDAPAH, ANDHRA PRADESH. Quantity: 2 by. Submission Deadline: 07-02-2026 15: 00: 00. Check eligibility and apply.
Satara District Panchayats
SATARA, MAHARASHTRA
Satara District Panchayats
SATARA, MAHARASHTRA
Satara District Panchayats
SATARA, MAHARASHTRA
Indian Army
EAST SIKKIM, SIKKIM
Panchayat Samiti Daund
PUNE, MAHARASHTRA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | Installation, Commissioning and testing for complete system | Yes including Civil Work, Designing, Fabrication, Cabling Work with suitable Bolts, Nuts, Clamps, Connectors and testing etc. |
| GENERIC | Wind-Solar PV Hybrid system consisting of | Wind Turbine, Solar PV Array Modules, Solar Charge Controller, Wind Charge Controller, Inverter, Batteries, Cables Protections, interconnect cables, switches, connectors etc. |
| GENERIC | Minimum Capacity of Wind-solar PV Hybrid system (in KW) | 1 |
| GENERIC | Minimum warrnty period for the entire powr plant system | 2, 4, 5 Or higher |
| SOLAR PV MODULE - STANDARDS | PV Module conforming to | IEC 61215/IS:14286 latest for Crystalline silicon terrestrial |
| SOLAR PV MODULE - STANDARDS | PV Module rating , Each (in Wp) - Must declare | 400 |
| SOLAR PV MODULE - CONSTRUCTION | PV Module efficiency | > 19% |
| PV MODULE - ARRAY STRUCTURE | Material grade of mounting structure | Structural Steel, Grade: E 300 |
| WIND MILL | Rated power output (in W) | 143 |
| WIND MILL | Wind speed for Rated power out put (in m/s) | 11 |
| WIND MILL | Maximum power output (in W) | > 500 |
| WIND MILL | Wind speed for maximum power output (in m/s) | 17 |
| WIND MILL | Cut in wind speed (in m/s) | 2.5 |
| WIND MILL | Cut out wind speed (in m/s) - Must declare | 18 |
| WIND MILL | Security / Survival wind speed (in m/s) | 40 |
| WIND MILL | Out put voltage, Maximum (In Volts) | 48 |
| WIND MILL | Turbine Material | Glass fiber reinforced plastic |
| WIND MILL | Frame structure Material | Galvanized G-90 Steel |
| WIND MILL | Wind mill suitable for charging the battery of | 24 V |
| WIND MILL | Provision of suitable charge controllers | 24 V |
| BATTERY BANK | Battery voltage (in Volts) | 24 |
| BATTERY BANK | Battery Capacity (in Ah) at C/10 disharge rate | 150 |
| INVERTER - INPUT - DC | Maximum input current for each MPPT (in A) | 28 |
| INVERTER - INPUT - DC | Max. Number of MPPT | 1 |
| INVERTER - INPUT - DC | Max. No. of string at input side of inverter ( input port +ve and -ve) ( hint: 1 sets contains 1 +ve and 1 -ve port) | 4 |
| INVERTER - INPUT - DC | MPPT Voltage range (in Volts) | 85 |
| INVERTER - INPUT - DC | Number of phase, input (in Nos.) | 1 |
| INVERTER - OUTPUT - AC | Rated output power (in KW) | 1 |
| INVERTER - OUTPUT - AC | Rated out put current per phase - Must declare (in A) | 4 |
| INVERTER - OUTPUT - AC | No. of Phase (in Nos.) | 1 |
| INVERTER - OUTPUT - AC | Rated out put voltage (in Volts) | 230 |
| INVERTER - OUTPUT - AC | Protections | Over current, Over Voltage, Over load 110%, Short circuit |
| INVERTER - CONSTRUCTION | Manual switch for disconnecting DC supply | Yes |
| INVERTER - CONSTRUCTION | THD (in %) | < 3% |
| INVERTER - CONSTRUCTION | Power factor at rated out put power | > 0.9 |
| INVERTER - ENCLOSURE | Material of enclosure | M.S. Plate |
| INVERTER - ENCLOSURE | Ingress protection for enclosures (In IP Rating) | 20, 23, 65 Or higher |
| INVERTER - ENCLOSURE | Inverter mounting type | Floor Mounted |
| INVERTER - ENVIRONMENTAL | Operating temperature, Minimum (in deg. C) | -25 Or lower |
| INVERTER - ENVIRONMENTAL | Operating temperature, Maximum(in deg. C) | 65 Or higher |
| INVERTER - ENVIRONMENTAL | Cooling medium | Intelligent fan cooling |
| INVERTER - ENVIRONMENTAL | Temperature rise protection | Shut down at 65 deg. C |
| INVERTER - DISPLAY | Type of display | LCD |
| INVERTER - DISPLAY | Display parameters | DC Voltage, DC Current, AC Voltage, AC Current, Out put frequency, Power Factor |
| ACCESSORIES | Standard accessories for eacch unit | MC4 DC Connectors, AC connectors, Mounting barakets, Botls and nuts |
| ACCESSORIES | Lightning arrestor for each unit | Yes |
| ACCESSORIES | Earthing for each inverter | G.I. Pipe, G.I. Wires and earthing as per IS:3043-1987. |
| ACCESSORIES | Danger boards and signages (in Nos.) | 1 |
| DC DISTRIBUTION | DC Distribution panel / box consists (for each system to receive the DC output from the PV array field) | DC Distribution box, Fuse, DC MCB, Surge arrestors |
| DC DISTRIBUTION | Enclosure Material | GRP( Glass reinforced plastic) |
| DC DISTRIBUTION | Enclosure protection for DC Distribution Box (in IP Rating) | 65 Or higher |
| DC DISTRIBUTION | Provision of bus bar and size | Copper bust bar, size as per inverter rating |
| DC DISTRIBUTION | Provision of circuit Breaker at input side (DC side) for each system | MCB 15 A |
| DC DISTRIBUTION | Provision of cables for input of each system | Copper cable as per IS:694 |
| DC DISTRIBUTION | Cable size for input | 2C x 6 Sq.mm |
| DC DISTRIBUTION | Cable length requirement for DC distribution (in m) | 25 |
| DC DISTRIBUTION | Cabling work at input side of each system | With PVC Conduit pipe with necessary clamps and screws |
| AC DISTRIBUTION | AC Distribution Panel Board for controlling the AC power from PCU/inverter | 1 Ph. 230 V, 50 Hz |
| AC DISTRIBUTION | Panel construction | Metal clad, totally enclosed, floor mounted, air insulated, cubical type with change over switch |
| AC DISTRIBUTION | Enclosure protection for AC Distribution Box (in IP Rating) | 54, 65 Or higher |
| AC DISTRIBUTION | Provision of circuit Breaker at output side (AC side) for each system | 10A-MCB |
| AC DISTRIBUTION | Provision of cables for output of each system | Copper cable as per IS:694 |
| AC DISTRIBUTION | Cable size for output | 2C x 6 Sq.mm |
| AC DISTRIBUTION | Cable length requirement for AC distribution (in m) | 20 |
| AC DISTRIBUTION | Cabling work at Output side for each system | With G.I. Cable Tray with fitment accessories |
| WIND LOAD | Regional wind withstand capacity which the PV Module mounting structure and Wind mill structure support is suitable to withstand (in Km/Hour) | 150 |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Maritime University
N/a
📍 LUCKNOW, UTTAR PRADESH
Solar Energy Corporation of India Limited
📍 NEW DELHI, DELHI
Indian Army
📍 MEERUT, UTTAR PRADESH
Bharat Petroleum Corporation Ltd
📍 GULBARGA, KARNATAKA
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS