TenderDekho Logo
GEM

Invitation to Bid - Power Generator - DG Set (up to 900 KVA) in SOUTH ANDAMAN, ANDAMAN & NICOBAR

Bid Publish Date

12-Feb-2026, 3:10 pm

Bid End Date

28-Feb-2026, 3:00 pm

EMD

₹22,000

Latest Corrigendum Available

Progress

Issue12-Feb-2026, 3:10 pm
Corrigendum23-Feb-2026
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 4

A tender has been published for N/a Power Generator - DG Set (up to 900 KVA) (Q2) in SOUTH ANDAMAN, ANDAMAN & NICOBAR. Quantity: 1 by. Submission Deadline: 28-02-2026 15: 00: 00. Check eligibility and apply.

Documents 3

GeM-Bidding-8974892.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Gujarat Forests And Environment Department DG Set Tender Bhavnagar 900 KVA 2025

N/a

BHAVNAGAR, GUJARAT

Posted: 18 December 2025
Closed: 29 December 2025
GEM

Directorate Of Collegiate Education Kerala 900 KVA DG Set Tender ISO Certified 2025

Directorate Of Collegiate Education

KOTTAYAM, KERALA

Posted: 23 December 2025
Closed: 3 January 2026
GEM

Power Generator - DG Set (up to 900 KVA)

N/a

AMRAVATI, MAHARASHTRA

Posted: 2 December 2025
Closed: 12 December 2025
GEM

Power Generator - DG Set (up to 900 KVA)

Central Water Commission (cwc)

KAMRUP, ASSAM

Posted: 11 November 2025
Closed: 26 November 2025
GEM

Power Generator - DG Set (up to 900 KVA)

Nhpc Limited

EAST SIANG, ARUNACHAL PRADESH

Posted: 15 February 2025
Closed: 15 March 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Power Generator INSTALLATION CONFIGURATIONS Power Generator installation configurations as defined in CPWD General Specifications for Electrical works - Part VII (DG Set) Fixed (Power Generators are permanently installed)"
OUTPUT CAPACITY RATING/ PHASE Nominal Rated Capacity (kVA) 30
OUTPUT CAPACITY RATING/ PHASE No of Phase (Single Phase-3-5kVA) (Single Phase or Three Phase-5 & 7-5, 10,15, 20, 25, 30 & 40 kVA) (Three Phase-50 to 900 kVA) Three Phase
ENGINE Rated Engine Power (kWm) 100 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator + Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience, 110 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience Or higher
ENGINE Type of Engine cooling Liquid Cooled
ENGINE Type of governer Electronic Or higher
ENGINE Number of cylinders (nos) 3
ENGINE Rated RPM of Engine (RPM) 1500
ENGINE Fuel High Speed Diesel (HSD)
ALTERNATOR Alternator Voltage Rating 415.0
ALTERNATOR Voltage Regulation Grade VG 3 Or higher
ALTERNATOR Alternator IP Rating IP 21, IP 22, IP 23 Or higher
CONTROL PANEL Control Panel Manual Control Panel
CONTROL PANEL Control Panel Location Inside the canopy
CONTROL PANEL IP Rating of Control Panel IP 53, IP 54, IP 55 Or higher
CONTROL PANEL Display meters in the control panel (with appropriate rating and accuracy class ) - inclusive in the scope of supply Multifunctional Digital display meter (displaying Voltage, Current, Frequency, Power Factor)
Fuel Tank Fuel Tank Features Fuel Tank capacity is sufficient for 8 hrs of running at full load
TRAILER Trailer NA for Fixed/Skid Mounted Power Generator
TRAILER Pay load of the Trailer 0, 500, 1000, 2000 Or higher
SCOPE OF INSTALLATION Installation with installation - inclusive in the scope of supply Or higher
SCOPE OF INSTALLATION Scope of installation for Diesel Generating Set when offered by the vendor - inclusive in the scope of supply(Part-1) a) Installation of Power Generator when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Power Generator and its constituent parts shall be generally conforming to CPWD General Specification for Electrical Works, Part - VII - latest. b) Foundation shall be constructed by the seller. Foundation shall be of PCC type with the ratio of 4:2:1. The length and breadth of the foundation shall be 300 mm more from the respective length and breadth of the Power Generator. The height of the foundation shall be 400 mm, i.e., 200 mm below and 200 mm above the ground level. All the materials / labour required for foundation work shall be supplied by the seller.
SCOPE OF INSTALLATION Scope of installation for Diesel Generating Set when offered by the vendor - inclusive in the scope of supply(Part-2) c) Supply, laying and termination of interconnecting power and control cable shall be done by the seller. The cable supplied shall be ISI marked heavy duty PVC insulated, armoured cable, with PVC outer Sheath of Type ST-2 (FR Grade, Category C1), with aluminium conductor having insulation of PVC compound type -C, suitable for rated voltage upto and including 1100 volts and conforming to IS: 1554 (Part-1) latest. For 3-Phase Power Generators, 3.5 core or higher core cables shall be used. Total length of the cable supplied by the seller shall be within 30 meters for each Power Generator with manual control panel and within 60 metres for each Power Generator with AMF control panel. The current rating of the cables shall be as indicated below: 2C, 6 Sq mm for Single Phase, 3.5 & 5.0 KVA 2C, 10 Sq mm for Single Phase, 7.5 & 10 KVA 2C, 25 Sq mm for Single Phase, 15 KVA 2C, 35 Sq mm for Single Phase, 20 KVA 2C, 70Sq mm for Single Phase, 25 KVA 2C, 95Sq mm for Single Phase, 30 KVA 2C, 120Sq mm for Single Phase, 40 KVA 4C, 4 Sq mm for Three Phase,
SCOPE OF INSTALLATION Scope of installation for Diesel Generating Set when offered by the vendor - inclusive in the scope of supply(Part-3) d) 10 KVA 4C, 6 Sq mm for Three Phase, 15 KVA 4C, 10 Sq mm for Three Phase, 20 & 25 KVA 4C, 16 Sq mm for Three Phase, 30 KVA 3.5C, 25 Sq mm for Three Phase, 40 KVA 3.5C, 35 Sq mm for Three Phase, 50 KVA 3.5C, 70 Sq mm for Three Phase, 62.5 & 75 KVA 3.5C, 95 Sq mm for Three Phase, 82.5 KVA 3.5C, 120 Sq mm for Three Phase, 100 KVA 3.5C, 185 Sq mm for Three Phase, 125 KVA 3.5C, 300 Sq mm for Three Phase, 160 KVA 3.5C, 2 Run of 120 Sq mm for Three Phase, 180 KVA 3.5C, 2 Run of 150 Sq mm for Three Phase, 200 KVA 3.5C, 2 Run of 185 Sq mm for Three Phase, 225 KVA 3.5C, 2 Run of 240 Sq mm for Three Phase, 250 & 275 KVA 3.5C, 3 Run of 185 Sq mm for Three Phase, 320 KVA 3.5C, 3 Run of 240 Sq mm for Three Phase, 380 & 400 KVA 3.5C, 4 Run of 240 Sq mm for Three Phase, 500, 600 & 750 KVA 3.5C, 6 Run of 240 Sq mm for Three Phase, 900 KVA
SCOPE OF INSTALLATION Scope of installation for Diesel Generating Set when offered by the vendor - inclusive in the scope of supply(Part-4) e) Construction of suitable earthing station and necessary connections shall be done by the seller. All the materials / labour required for construction of earthing station shall be supplied by the seller. The total number of earthing pits/stations shall be 4, i.e., 2 for neutral and 2 for body-earthing. Netutral earthing shall be done with copper Plate and Body earthing shall be done with G.I. plate / Copper. The consignee should choose installation site in such a way that the earthing stations can be made within 10 metres of the Power Generator. Earthing station shall be typically constructed as per prevalent standard practices and shall be generally conforming to CPWD General specification for Electrical Works, Part - VII & Part - I - latest. e) Installation of Fuel Tank including foundation / stand shall be done by the seller. f)The warranty is applicable upto specified value of month/hours whichever occurs first's.
WARRANTY/SERVICES Warranty on Complete power genertor/DG Set 12, 24, 36 Or higher
WARRANTY/SERVICES Number of preventive maintenance visits offered in an year during warranty period (Supply of all consumables is the buyer's responsibilty)* 1, 2
TEST REPORTS Type of lab which carried out Test of Complete Product to prove the conformity of product as per specification Certificates required as per CPCB, Govt Lab, NABL accredited lab, NA
TEST REPORTS Test report Available for (Test/approval) Type Approval Certificate for the specified rating of the Power Generator from any of the designated agency authorized by CPCB, COP Certificate for engine, Type test report and Endurance test report for Engine as per IS: 10001 latest / IS: 10002 latest, Type test report for Alternator as per IS:13364 (Part-1) latest / IS:13364 (Part-2) latest to prove conformity to the specifications

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Certificate (Requested in ATC)

4

OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria

5

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

1 Update
#1

Update

23-Feb-2026

Extended Deadline

28-Feb-2026, 3:00 pm

Opening Date

28-Feb-2026, 3:30 pm