Bid Publish Date
25-Aug-2026, 10:01 pm
Bid End Date
05-Sep-2026, 11:00 am
EMD
₹44,220
Location
Progress
Public procurement opportunity for Indian Army FRP Shelters - Barrel Type Cabin (Five Men) (Q3) in WEST DELHI, DELHI. Quantity: 2 issued by. Submission Deadline: 05-09-2026 11: 00: 00. View full details and respond.
Quantity
2
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
50% Lowest Priced Technically Qualified Bidders
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
7
OEM Avg. Turnover
10
Past Performance
30 %
Warranty Period
1 years
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
FRP Shelters - Barrel Type Cabin (Five Men) (Q3)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
14
Max Delivery Days
120
Delivery Locations
1
Delivery Cities
South West delhi
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| - | South West delhi | South West delhi | - | - | 2 | 120 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | Configuration | Curved panel type FRP shelter of size 4880 mm x 4880 mm to be from side entry chamber of size 2387 mm x 1220 mm and height of 2440 mm - As per Drawing |
| GENERIC | Scope of supply | Erection of the shelters to be done by consignee himself - Supplier to furnish comprehensive erection manual including material list giving detailed instruction to erect the shelters at site - All panels to be assigned a serial number and to be referred to by a serial number in the erection manual, Erection of the shelters to be done by supplier - For which supplier will include erection charges in offer price. |
| GENERIC | Time period for copletion of Erection work (If opted erection by supplier) | Within 20 days of the date of receipt of consignee's confirmation regarding completion of ground and foundation work, Within 30 days of the date of receipt of consignee's confirmation regarding completion of ground and foundation work, Within 40 days of the date of receipt of consignee's confirmation regarding completion of ground and foundation work, N.A Since Erection is by consignee himself. |
| GENERIC | Suitability / structural stability / completness of structures, the structure is intended for use in | Designed for - In wind condition of 150 km/Hr - Having 2 meters standing snow - With external temperature of Minus 50 Degree C and Internal temperature 20 degree C - and 200 kg/square meter uniformaly distributed load on floor - Shelter should be structurally stable and suitable to meet severity of these climatic condition., In wind condition of 55m/s - in Seismic zone V and ambient temprature range 0 degree C to (+) 50 degree C - Shelter should be structurally stable and suitable to meet severity of these climatic condition. |
| PANELS | Size of each panel | 1220 mm x 1220 mm |
| PANELS | Weight of panel | To be about 20 kg. |
| PANELS | Thickness of each panel | To be 50 mm Rigid Phenolic in between, To be 50 mm PU Foam in between |
| PANELS | Roof and Wall panels to be made of | FRP laminates with rigid phenolic, FRP laminates with PU Foam |
| PANELS | Floor panels to be made of | FRP laminates with PU Foam. |
| PANELS | Laying sequence of Moulding panels | (a)Gel coat - (b)First layer of CSM (chopped strand mat) - (c)Woven Roving - (d)Second layer of CSM - (e)Insulation material as specified - (f)Repeat sequence as per (d) to (a) |
| PANELS | Specification of Flanges thickness built up | Two layer CSM of 450 gm/sq. mtr each - One layer woven roving of 600 gm/sq. mtr - Two layer CSM of 450 gm/sq. mtr each - One layer woven roving of 600 gm/sq. mtr |
| PROPERTIES OF MATERIAL | Polyester Resin | Polyester used for shelter to be of class I - Water absorption of cast resin to be 25 mg maximum and to be pass requirement of Type-E/Type in respect of Inflammability of cast resin as per BS : 3532-90 / IS : 6746-latest |
| PROPERTIES OF MATERIAL | For bonding and insulation between FRP laminates | Rigid Phenolic slabs to be used, Rigid PU Foam slabs to be used |
| PROPERTIES OF MATERIAL | Compressive strength of Rigid phenolic/PU Foam (as per BS : 3987/86 | To be 2.5 kg/sq. cm to 6.7 kg/sq.cm |
| PROPERTIES OF MATERIAL | Thermal conductivity of Rigid phenolic/PU Foam at 10 deg C (as per BS : 4370 (Pt 2)/93 | To be 0.017 Kcal/h/m to 0.022Kcal/h/m |
| PROPERTIES OF MATERIAL | Flammability of Rigid Phenolic/PU Foam (as per ASTM 1692) | To be Non-flammable |
| PROPERTIES OF MATERIAL | Ignitability of Rigid Phenolic/PU Foam (asper BS : 476 Pt 5/87) | To be of class P |
| WARRANTY | Warranty period | 1-Year, 2-years, 3-Years |