Bid Publish Date
16-May-2025, 4:56 pm
Bid End Date
26-May-2025, 5:00 pm
Location
Progress
RAQuantity
398
Category
Servicing of 1.5,2.0 TR Split A.C. Units
Bid Type
Two Packet Bid
Bharat Sanchar Nigam Limited Portal(bsnl) announces a tender for Servicing of 1. 5, 2. 0 TR Window A. C. Units, Installation of 1. 5, 2TR window type A. C. in the existing window, Repairing and Testing of 1. 5, 2. 0 TR Capacity Window AC Units removal of leakage, Replacement of 1 8 HP Double Shaft Fan, Blower Motor, Providing and fixing of 3mm thick ply wood in the existing window, Supplying Fixing of Running capacitor 45 mfd 50mfd, Supplying Fixing of PCB repairing for remote control, Supplying Fixing of SITC of new PCB for remote control, Supplying Fixing of Thermostat, Supplying Fixing of Condenser Fan Blade, Supplying Fixing of 15, 16 Amp. Pin Plug Top, Supplying Fixing of Starting Capacitor 120 150 mfd, Supplying Fixing of Copper Wiring kit, Supplying Fixing of Synthetic Filter, Supplying Fixing of Blower for Window AC, Supplying Fixing of Selector Switches, Supplying Fixing of Starting Relay, S Fixing of 3 Core 2. 5 Sqmm Grade PVC insulated copper flexible cable, Replacement of cooling coil 1. 5, 2. 0 TR Window AC unit, Replacement of condesnsing coil of existing 1. 5, 2. 0 TR Window AC unit, Supply Fixing of Remote Hand Set, Replacement of 1. 5 TR Capacity Rotary Sealed Compressor, Replacement of 2. 0 TR Capacity Rotary Sealed Compressor, Replacement of 1. 5 TR Capacity Reciprocating Hermetically Compressor, Replacement of 2. 0 TR Capacity Reciprocating Hermetically Compressor, Dismantling 1. 5TR, 2TR Window AC unit, Dismantling 1. 5TR, 2TR Split AC unit, ITC of 1. 5, 2. 0 TR Split AC units at desired location, Servicing of 1. 5, 2. 0 TR Split A. C. Units, Repairing and Testing of 1. 5, 2. 0 TR Capacity Split AC Unit, Replacement of 1 by 8 HP Condenser Fan Motor, Replacement of 1 by 4 HP Condenser Fan Motor, Replacement of 1 by 35 HP Indoor Blower Motor, Replacement, Fixing of Copper wiring kit, Replacement, Fixing of Condensor Fan Blade, Replacement Fixing of PCB repairing for remote control, Replacement, Fixing of SITC of new PCB for remote control, Replacement, Supply, Fixing of Remote Hand Set, S, Fixing 20 mm dia PVC drain pipe in recess, SFixing PVC flexible pipe to cover the refrigerant pipes, Pdg. and installing size 22 Gauge of 1 4 inch size nominal dia, Pdg. and installing size 22 Gauge of 5 8 inch size nominal dia, Replacement of condesnser coil 1. 5, 2. 0 TR split AC unit, Replacement of cooling coil 1. 5, 2. 0 TR split AC unit, Replacement of existing faulty, unseriviceable 1. 5 TR Indoor Units, S fixing of MS frame a 40mmx40mmx5 mm MS angle iron, b 40mmx5mm MS flat, Sfixing of powder coated prefabricated wall floor mounting stand, Repairing of inveter type split AC a 1. 5 TR Inverter SAC PCB card, b 1. 5 TR Inverter SAC Outdoor motor, c 1. 5 TR Inverter SAC Indoor motor, Shifting and reinstallation of 3 phase tower type Split AC unit, SITC of vaccumization and Nitrogen testing a 12. 7 mm dia. , b 19. 10 mm dia. , Sfixing of control cum transmission wiring a 4c x 4 sqmm, SFixing of PVC insulated PVC sheathed copper conductor, Sfixing FP sheet steel 25 32 A 415 V C curve FP MCB, Minor civil existing Brick Stone RCC wall having approx. thickness of 1 Metre for fixing, Providing and filling of Refrigerant R 410 R 32 as required gas, Pfixing of GI frame tray of 24 guage of size 3feetx1. 5 feet, Supply and fixing of AC changeover Sequence in CENTRAL DELHI, DELHI. Quantity: 398. Submission Deadline: 26-05-2025 17: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Servicing of 1.5, 2.0 TR Window A.C. Units , Installation of 1.5, 2TR window type A.C. in the existing window , Repairing and Testing of 1.5, 2.0 TR Capacity Window AC Units removal of leakage , Replacement of 1 8 HP Double Shaft Fan, Blower Motor , Providing and fixing of 3mm thick ply wood in the existing window , Supplying Fixing of Running capacitor 45 mfd 50mfd , Supplying Fixing of PCB repairing for remote control , Supplying Fixing of SITC of new PCB for remote control , Supplying Fixing of Thermostat , Supplying Fixing of Condenser Fan Blade , Supplying Fixing of 15,16 Amp. Pin Plug Top , Supplying Fixing of Starting Capacitor 120 150 mfd , Supplying Fixing of Copper Wiring kit , Supplying Fixing of Synthetic Filter , Supplying Fixing of Blower for Window AC , Supplying Fixing of Selector Switches , Supplying Fixing of Starting Relay , S Fixing of 3 Core 2.5 Sqmm Grade PVC insulated copper flexible cable , Replacement of cooling coil 1.5, 2.0 TR Window AC unit , Replacement of condesnsing coil of existing 1.5,2.0 TR Window AC unit , Supply Fixing of Remote Hand Set , Replacement of 1.5 TR Capacity Rotary Sealed Compressor , Replacement of 2.0 TR Capacity Rotary Sealed Compressor , Replacement of 1.5 TR Capacity Reciprocating Hermetically Compressor , Replacement of 2.0 TR Capacity Reciprocating Hermetically Compressor , Dismantling 1.5TR,2TR Window AC unit , Dismantling 1.5TR,2TR Split AC unit , ITC of 1.5, 2.0 TR Split AC units at desired location , Servicing of 1.5,2.0 TR Split A.C. Units , Repairing and Testing of 1.5,2.0 TR Capacity Split AC Unit , Replacement of 1 by 8 HP Condenser Fan Motor , Replacement of 1 by 4 HP Condenser Fan Motor , Replacement of 1 by 35 HP Indoor Blower Motor , Replacement, Fixing of Copper wiring kit , Replacement , Fixing of Condensor Fan Blade , Replacement Fixing of PCB repairing for remote control , Replacement,Fixing of SITC of new PCB for remote control , Replacement, Supply, Fixing of Remote Hand Set , S, Fixing 20 mm dia PVC drain pipe in recess , SFixing PVC flexible pipe to cover the refrigerant pipes , Pdg. and installing size 22 Gauge of 1 4 inch size nominal dia , Pdg. and installing size 22 Gauge of 5 8 inch size nominal dia , Replacement of condesnser coil 1.5, 2.0 TR split AC unit , Replacement of cooling coil 1.5, 2.0 TR split AC unit , Replacement of existing faulty, unseriviceable 1.5 TR Indoor Units , S fixing of MS frame a 40mmx40mmx5 mm MS angle iron , b 40mmx5mm MS flat , Sfixing of powder coated prefabricated wall floor mounting stand , Repairing of inveter type split AC a 1.5 TR Inverter SAC PCB card , b 1.5 TR Inverter SAC Outdoor motor , c 1.5 TR Inverter SAC Indoor motor , Shifting and reinstallation of 3 phase tower type Split AC unit , SITC of vaccumization and Nitrogen testing a 12.7 mm dia. , b 19.10 mm dia. , Sfixing of control cum transmission wiring a 4c x 4 sqmm , SFixing of PVC insulated PVC sheathed copper conductor , Sfixing FP sheet steel 25 32 A 415 V C curve FP MCB , Minor civil existing Brick Stone RCC wall having approx. thickness of 1 Metre for fixing , Providing and filling of Refrigerant R 410 R 32 as required gas , Pfixing of GI frame tray of 24 guage of size 3feetx1.5 feet , Supply and fixing of AC changeover Sequence
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Servicing of 1.5, 2.0 TR Window A.C. Units
Servicing of following capacity Window AC Units including washing and cleaning of filters, complete unit i.e. evaporator unit, condenser unit i c oiling, greasing of motors, loading unloading testing commissioning etc. complete as reqd. a 1.5 2.0 TR Window A.C. Units
Installation of 1.5, 2TR window type A.C. in the existing window
Installation of 1.5 2TR window type A.C. in the existing window i c modification and fixing suitable wooden frame, loading unloading etc complete as reqd.
Repairing and Testing of 1.5, 2.0 TR Capacity Window AC Units removal of leakage
Repairing and Testing of 1.5 2.0 TR Capacity Window AC Units, flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vaccumising, removal of leakage in Indoor unit and out door unit including supply and charging of refrigerant gas R 22 R 32 R 410 and oiling, greasing of motors, testing commissioning etc. complete as reqd.
Replacement of 1 8 HP Double Shaft Fan, Blower Motor
Replacement of following faulty motor with new copper wounded motor suitable for operation on single phase 230 V, A C supply in the existing Split Window AC unit i c removal of faulty motor, making electrical connections, testing, commissioning etc. complete as reqd. M s Crompton, Ashu or as per manufacturer recommendation NOTE The motor shall be guaranteed for One Year. M s Hitachi Blue star LG make a 1 8 HP Double Shaft Fan Blower Motor Copper Wounded M s Crompton Ashu or as per manufacturer recommendation
Providing and fixing of 3mm thick ply wood in the existing window
Providing and fixing of 3mm thick ply wood in the existing window i c cutting and fixing with the help of screws etc. complete as required.
Supplying Fixing of Running capacitor 45 mfd 50mfd
Supplying Fixing of following items in existing 1.5 2.0 TR capacity Window Split AC unit suitable for operation on Single phase, 240 Volt, AC Supply, testing, commissioning etc. complete as reqd. a Running capacitor 45 mfd 50 plus 5 mfd
Supplying Fixing of PCB repairing for remote control
b PCB repairing for remote control of A C unit
Supplying Fixing of SITC of new PCB for remote control
c SITC of new PCB for remote control of AC unit
Supplying Fixing of Thermostat
d Thermostat Danfoss or Renutrol
Supplying Fixing of Condenser Fan Blade
e Condenser Fan Blade Transparent PVC Metallic
Supplying Fixing of 15,16 Amp. Pin Plug Top
f 15 16 Amp. Pin Plug Top
Supplying Fixing of Starting Capacitor 120 150 mfd
g Starting Capacitor 120 150 mfd
Supplying Fixing of Copper Wiring kit
h Copper Wiring kit
Supplying Fixing of Synthetic Filter
i Synthetic Filter
Supplying Fixing of Blower for Window AC
j Blower for Window A c
Supplying Fixing of Selector Switches
k Selector Switches
Supplying Fixing of Starting Relay
l Starting Relay M s Ranutrol or SS make
S Fixing of 3 Core 2.5 Sqmm Grade PVC insulated copper flexible cable
S Fixing of following size 1.1 KV Grade PVC insulated copper conductor flexible cable in the existing M.S. Tray Surface Wall including S F saddles, screws, thimbles i c making connections, testing etc. complete as required. Make Polycab Havells a 3 Core 2.5 Sqmm
Replacement of cooling coil 1.5, 2.0 TR Window AC unit
Replacement of cooling coil 1.5 2.0 TR Window AC unit i c removong the old coil nut bolt fixing the new coil refrigerant piping brzing connetion testing commissioning etc as reqd.
Replacement of condesnsing coil of existing 1.5,2.0 TR Window AC unit
Replacement of condesnsing coil of existing 1.5 2.0 TR Window AC unit with new copper coil i c removing the old coil nut bolt installing the new coil brazing testing commissioning etc complete as reqd.
Supply Fixing of Remote Hand Set
Supply Fixing of Remote Hand Set with enclosure comlete asreqd. i Hitachi LG Voltas or Blue star.
Replacement of 1.5 TR Capacity Rotary Sealed Compressor
Replacement of following defective unserviceable compressor in the existing Window Split AC units with following new compressor suitable for operation on single phase, 50 Hz A C Supply i c removal and re installation of defective compressor, refrigerant piping and nut bolts of foundation, electrical connection and making connection with existing refrigerant pipe lines, brazing, electrical wire cable terminations, making joints wherever required , testing, commissioning etc. complete as reqd. NOTE Original Invoice and Test Certificate of the compressor shall be submitted. a 1.5 TR Capacity Rotary Sealed Compressor M s Hitachi LG Voltas
Replacement of 2.0 TR Capacity Rotary Sealed Compressor
b 2.0 TR Capacity Rotary Sealed Compressor M s Hitachi LG Voltas
Replacement of 1.5 TR Capacity Reciprocating Hermetically Compressor
c 1.5 TR Capacity Reciprocating Hermetically Sealed Compressor M s Hitachi Daikin LG Voltas Emerson
Replacement of 2.0 TR Capacity Reciprocating Hermetically Compressor
d 2.0 TR Capacity Reciprocating Hermitically Sealed Compressor M s Hitachi Voltas LG Emerson
Dismantling 1.5TR,2TR Window AC unit
Dismantling 1.5TR 2TR Window AC unit and keeping all the dismantled items at desired location as per the directions of engineer in charge etc as required.
Dismantling 1.5TR,2TR Split AC unit
Dismantling 1.5TR 2TR Split AC unit along with refrigerant pipe lines, power cable and other accessories and keeping all the dismantled items at desired location as per the directions of engineer in charge etc as required.
ITC of 1.5, 2.0 TR Split AC units at desired location
ITC of 1.5 2.0 TR Split AC units at desired location, i c fixing of refrigerant piping with insulation, drain pipe, flexible covering, power connections, testing, commissioning etc. complete as reqd. a 1.5 2.0 TR Split A.C. Units
Servicing of 1.5,2.0 TR Split A.C. Units
Servicing of following capacity Split AC Units including washing and cleaning of filters, complete unit i.e evaporator unit, condensor unit i c oiling, greasing of motors, testing, commissioning etc. complete as reqd. a 1.5 2.0 TR Split A.C. Units
Repairing and Testing of 1.5,2.0 TR Capacity Split AC Unit
Repairing and Testing of 1.5 2.0 TR Capacity Split AC Units, flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vaccumising, removal of leakage in Indoor unit and out door unit including supply and charging of refrigerant gas R 22 R 32 R 410 and oiling, greasing of motors, testing commissioning etc. complete as reqd.
Replacement of 1 by 8 HP Condenser Fan Motor
Replacement of following faulty motor with new copper wounded motor suitable for operation on single phase 230 V, A C supply in the existing Split AC unit i c removal of faulty motor, making electrical connections, testing, commissioning etc. complete as reqd. M s Crompton, Ashu or as per manufacturer recommendation NOTE The motor shall be guaranteed for One Year. M s Hitachi Blue star LG make a 1 8 HP Condenser Fan Motor
Replacement of 1 by 4 HP Condenser Fan Motor
b 1 4 HP Condenser Fan Motor condensing fan motor
Replacement of 1 by 35 HP Indoor Blower Motor
c 1 35 HP Indoor Blower Motor
Replacement, Fixing of Copper wiring kit
Replacement Fixing of following items in existing 1.5 2.0 TR capacity Split AC unit suitable for operation on Single phase, 240 Volt, AC Supply, testing, commissioning etc. complete as reqd. a Copper wiring kit
Replacement , Fixing of Condensor Fan Blade
b Condensor Fan Blade Transparent PVC Metallic
Replacement Fixing of PCB repairing for remote control
c PCB repairing for remote control of A C unit
Replacement,Fixing of SITC of new PCB for remote control
d SITC of new PCB for remote control of AC unit
Replacement, Supply, Fixing of Remote Hand Set
e Supply Fixing of Remote Hand Set with enclosure Hitchi LG Voltas gujral
S, Fixing 20 mm dia PVC drain pipe in recess
S Fixing 20 mm dia PVC drain pipe in recess or on surface for drainage of split AC units i c connections etc complete as reqd.
SFixing PVC flexible pipe to cover the refrigerant pipes
S Fixing PVC flexible pipe to cover the refrigerant pipes and power cables in the existing wall on surface M S Tray with saddles, screws including S F clamps etc. as required. a 50 mm Dia
Pdg. and installing size 22 Gauge of 1 4 inch size nominal dia
Pdg. and installing following size 22 Gauge of copper refrigerant pipe along with insulation including cutting bending, jointing, brazing , testing and commissioning etc as required. a 1 4 inch size nominal dia
Pdg. and installing size 22 Gauge of 5 8 inch size nominal dia
b 5 8 inch size nominal dia
Replacement of condesnser coil 1.5, 2.0 TR split AC unit
Replacement of condesnser coil of existing outdoor units of 1.5 2.0 TR split AC unit with new copper coil i c removing the old coil nut bolt installing the new coil brazing testing commissioning etc complete as reqd.
Replacement of cooling coil 1.5, 2.0 TR split AC unit
Replacement of cooling coil 1.5 2.0 TR split AC unit i c removong the old coil nut bolt fixing the new coil refrigerant piping brazing connetion testing commissioning etc as reqd.
Replacement of existing faulty, unseriviceable 1.5 TR Indoor Units
Replacement of existing faulty unseriviceable 1.5 TR Indoor Units of Split AC Units by supplying new 1.5 TR Indoor Unit, suitable for operation on 230 V AC supply, complete with blower, cooling coil, filters, controls and all accessories and remote control, etc. complete as reqd. Make M S Hitachi Blue Star Carrier Voltas make
S fixing of MS frame a 40mmx40mmx5 mm MS angle iron
Supplying, fabricating and fixing of MS frame made out of following members i c cutting, welding, grouting and painting the MS members etc. complete as reqd. a 40mmx40mmx5 mm MS angle iron.
b 40mmx5mm MS flat
b 40mmx5mm MS flat.
Sfixing of powder coated prefabricated wall floor mounting stand
Supply and fixing of powder coated prefabricated wall floor mounting stand for out door unit made out of M.S.sheet M.S. angle iron of suitable size i c cutting, welding, painting and grouting etc. complete as required.
Repairing of inveter type split AC a 1.5 TR Inverter SAC PCB card
Repairing of faulty 1.5 TR inveter type split AC with repairing of following item i c dismantling, repairing and refixing , testing commissioning etc complete as reqd. a 1.5 TR Inverter SAC PCB card
b 1.5 TR Inverter SAC Outdoor motor
b 1.5 TR Inverter SAC Outdoor motor
c 1.5 TR Inverter SAC Indoor motor
c 1.5 TR Inverter SAC Indoor motor
Shifting and reinstallation of 3 phase tower type Split AC unit
Shifting and reinstallation of existing 3.0 TR , 3 phase tower type Split AC unit including shifting charges for shifting of indoor and outdoor unit from one place to another in the same bldg., mounting fitting of indoor and outdoor units at proper locations, suitable electrical connection wiring etc. complete as required.
SITC of vaccumization and Nitrogen testing a 12.7 mm dia.
Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft hard drawn copper refrigerant piping for AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing brazing including accessories, insulated with XPLE Class O tubular insulation with Class O closed cell elastomeric nitrite rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required. a 12.7 mm dia. OD with tube thickness 1.2 mm with 19 mm thick insulation
b 19.10 mm dia.
b 19.10 mm dia. OD with tube thickness 1.2 mm with 19 mm thick insulation
Sfixing of control cum transmission wiring a 4c x 4 sqmm
Supply and fixing of control cum transmission wiring and AC power supply cable of shielded Copper conductor for looping between indoor and outdoor units complete as manufacturers standard compete as required. A 4c X 4 sqmm PVC insulated copper conductor cable
SFixing of PVC insulated PVC sheathed copper conductor
Supply Fixing of PVC insulated PVC sheathed copper conductor armoured cable of 5c X4 sqmm size of 1.1Kv grade on surface recess of wall with MS saddle complete as required.
Sfixing FP sheet steel 25 32 A 415 V C curve FP MCB
Supplying and fixing FP sheet steel enclosure on surface recess along with 25 32 A 415 V C curve FP MCB complete with connections, testing and commissioning etc. as required. Havells Legrand or SS Makes
Minor civil existing Brick Stone RCC wall having approx. thickness of 1 Metre for fixing
Minor civil i.e. making hole in the existing Brick Stone RCC wall having approx. thickness of 1 Metre for fixing the pipe repairing the same with sand cement as per direction of Engineer in charge etc., complete as required with same type of material.
Providing and filling of Refrigerant R 410 R 32 as required gas
Providing and filling of Refrigerant R 410 R 32 as required gas approx 4.5kg in the circuit of 3.0TR tower type AC as , up to the required pressure, and holding N2 pressure in circuit for 24 hours for lekage check and vacumm in circuit including testing commissioning etc complete as required.
Pfixing of GI frame tray of 24 guage of size 3feetx1.5 feet
Providing and fixing of GI frame tray of 24 guage of size 3feetx1.5 feet with hight of 1inch on edges with PVC collection nipple in tray for window AC drain collection and provision of fixing below window AC frame with GI wire etc complete as reqd.
Supply and fixing of AC changeover Sequence
Supply and fixing of AC changeover Sequence Timer for cyclic operation of two any type of Air Conditioners, automatic switch over, 2 Channels Power Voltage 220V i c 4 sqmm cable connection etc complete as reqd.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Servicing of 1.5, 2.0 TR Window A.C. Units | Servicing of following capacity Window AC Units including washing and cleaning of filters, complete unit i.e. evaporator unit, condenser unit i c oiling, greasing of motors, loading unloading testing commissioning etc. complete as reqd. a 1.5 2.0 TR Window A.C. Units | 12 | job | [email protected] | 270 | |
| 2 | Installation of 1.5, 2TR window type A.C. in the existing window | Installation of 1.5 2TR window type A.C. in the existing window i c modification and fixing suitable wooden frame, loading unloading etc complete as reqd. | 8 | job | [email protected] | 270 | |
| 3 | Repairing and Testing of 1.5, 2.0 TR Capacity Window AC Units removal of leakage | Repairing and Testing of 1.5 2.0 TR Capacity Window AC Units, flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vaccumising, removal of leakage in Indoor unit and out door unit including supply and charging of refrigerant gas R 22 R 32 R 410 and oiling, greasing of motors, testing commissioning etc. complete as reqd. | 14 | job | [email protected] | 270 | |
| 4 | Replacement of 1 8 HP Double Shaft Fan, Blower Motor | Replacement of following faulty motor with new copper wounded motor suitable for operation on single phase 230 V, A C supply in the existing Split Window AC unit i c removal of faulty motor, making electrical connections, testing, commissioning etc. complete as reqd. M s Crompton, Ashu or as per manufacturer recommendation NOTE The motor shall be guaranteed for One Year. M s Hitachi Blue star LG make a 1 8 HP Double Shaft Fan Blower Motor Copper Wounded M s Crompton Ashu or as per manufacturer recommendation | 10 | nos | [email protected] | 270 | |
| 5 | Providing and fixing of 3mm thick ply wood in the existing window | Providing and fixing of 3mm thick ply wood in the existing window i c cutting and fixing with the help of screws etc. complete as required. | 5 | job | [email protected] | 270 | |
| 6 | Supplying Fixing of Running capacitor 45 mfd 50mfd | Supplying Fixing of following items in existing 1.5 2.0 TR capacity Window Split AC unit suitable for operation on Single phase, 240 Volt, AC Supply, testing, commissioning etc. complete as reqd. a Running capacitor 45 mfd 50 plus 5 mfd | 10 | nos | [email protected] | 270 | |
| 7 | Supplying Fixing of PCB repairing for remote control | b PCB repairing for remote control of A C unit | 10 | nos | [email protected] | 270 | |
| 8 | Supplying Fixing of SITC of new PCB for remote control | c SITC of new PCB for remote control of AC unit | 5 | nos | [email protected] | 270 | |
| 9 | Supplying Fixing of Thermostat | d Thermostat Danfoss or Renutrol | 5 | nos | [email protected] | 270 | |
| 10 | Supplying Fixing of Condenser Fan Blade | e Condenser Fan Blade Transparent PVC Metallic | 5 | nos | [email protected] | 270 | |
| 11 | Supplying Fixing of 15,16 Amp. Pin Plug Top | f 15 16 Amp. Pin Plug Top | 5 | nos | [email protected] | 270 | |
| 12 | Supplying Fixing of Starting Capacitor 120 150 mfd | g Starting Capacitor 120 150 mfd | 5 | nos | [email protected] | 270 | |
| 13 | Supplying Fixing of Copper Wiring kit | h Copper Wiring kit | 5 | nos | [email protected] | 270 | |
| 14 | Supplying Fixing of Synthetic Filter | i Synthetic Filter | 5 | nos | [email protected] | 270 | |
| 15 | Supplying Fixing of Blower for Window AC | j Blower for Window A c | 5 | nos | [email protected] | 270 | |
| 16 | Supplying Fixing of Selector Switches | k Selector Switches | 5 | nos | [email protected] | 270 | |
| 17 | Supplying Fixing of Starting Relay | l Starting Relay M s Ranutrol or SS make | 5 | nos | [email protected] | 270 | |
| 18 | S Fixing of 3 Core 2.5 Sqmm Grade PVC insulated copper flexible cable | S Fixing of following size 1.1 KV Grade PVC insulated copper conductor flexible cable in the existing M.S. Tray Surface Wall including S F saddles, screws, thimbles i c making connections, testing etc. complete as required. Make Polycab Havells a 3 Core 2.5 Sqmm | 25 | mtr | [email protected] | 270 | |
| 19 | Replacement of cooling coil 1.5, 2.0 TR Window AC unit | Replacement of cooling coil 1.5 2.0 TR Window AC unit i c removong the old coil nut bolt fixing the new coil refrigerant piping brzing connetion testing commissioning etc as reqd. | 4 | nos | [email protected] | 270 | |
| 20 | Replacement of condesnsing coil of existing 1.5,2.0 TR Window AC unit | Replacement of condesnsing coil of existing 1.5 2.0 TR Window AC unit with new copper coil i c removing the old coil nut bolt installing the new coil brazing testing commissioning etc complete as reqd. | 4 | nos | [email protected] | 270 | |
| 21 | Supply Fixing of Remote Hand Set | Supply Fixing of Remote Hand Set with enclosure comlete asreqd. i Hitachi LG Voltas or Blue star. | 6 | nos | [email protected] | 270 | |
| 22 | Replacement of 1.5 TR Capacity Rotary Sealed Compressor | Replacement of following defective unserviceable compressor in the existing Window Split AC units with following new compressor suitable for operation on single phase, 50 Hz A C Supply i c removal and re installation of defective compressor, refrigerant piping and nut bolts of foundation, electrical connection and making connection with existing refrigerant pipe lines, brazing, electrical wire cable terminations, making joints wherever required , testing, commissioning etc. complete as reqd. NOTE Original Invoice and Test Certificate of the compressor shall be submitted. a 1.5 TR Capacity Rotary Sealed Compressor M s Hitachi LG Voltas | 2 | nos | [email protected] | 270 | |
| 23 | Replacement of 2.0 TR Capacity Rotary Sealed Compressor | b 2.0 TR Capacity Rotary Sealed Compressor M s Hitachi LG Voltas | 2 | nos | [email protected] | 270 | |
| 24 | Replacement of 1.5 TR Capacity Reciprocating Hermetically Compressor | c 1.5 TR Capacity Reciprocating Hermetically Sealed Compressor M s Hitachi Daikin LG Voltas Emerson | 2 | nos | [email protected] | 270 | |
| 25 | Replacement of 2.0 TR Capacity Reciprocating Hermetically Compressor | d 2.0 TR Capacity Reciprocating Hermitically Sealed Compressor M s Hitachi Voltas LG Emerson | 2 | nos | [email protected] | 270 | |
| 26 | Dismantling 1.5TR,2TR Window AC unit | Dismantling 1.5TR 2TR Window AC unit and keeping all the dismantled items at desired location as per the directions of engineer in charge etc as required. | 8 | job | [email protected] | 270 | |
| 27 | Dismantling 1.5TR,2TR Split AC unit | Dismantling 1.5TR 2TR Split AC unit along with refrigerant pipe lines, power cable and other accessories and keeping all the dismantled items at desired location as per the directions of engineer in charge etc as required. | 5 | job | [email protected] | 270 | |
| 28 | ITC of 1.5, 2.0 TR Split AC units at desired location | ITC of 1.5 2.0 TR Split AC units at desired location, i c fixing of refrigerant piping with insulation, drain pipe, flexible covering, power connections, testing, commissioning etc. complete as reqd. a 1.5 2.0 TR Split A.C. Units | 6 | job | [email protected] | 270 | |
| 29 | Servicing of 1.5,2.0 TR Split A.C. Units | Servicing of following capacity Split AC Units including washing and cleaning of filters, complete unit i.e evaporator unit, condensor unit i c oiling, greasing of motors, testing, commissioning etc. complete as reqd. a 1.5 2.0 TR Split A.C. Units | 20 | job | [email protected] | 270 | |
| 30 | Repairing and Testing of 1.5,2.0 TR Capacity Split AC Unit | Repairing and Testing of 1.5 2.0 TR Capacity Split AC Units, flushing the system, pressure testing with Nitrogen gas holding the pressure for 24 hours, vaccumising, removal of leakage in Indoor unit and out door unit including supply and charging of refrigerant gas R 22 R 32 R 410 and oiling, greasing of motors, testing commissioning etc. complete as reqd. | 10 | job | [email protected] | 270 | |
| 31 | Replacement of 1 by 8 HP Condenser Fan Motor | Replacement of following faulty motor with new copper wounded motor suitable for operation on single phase 230 V, A C supply in the existing Split AC unit i c removal of faulty motor, making electrical connections, testing, commissioning etc. complete as reqd. M s Crompton, Ashu or as per manufacturer recommendation NOTE The motor shall be guaranteed for One Year. M s Hitachi Blue star LG make a 1 8 HP Condenser Fan Motor | 5 | nos | [email protected] | 270 | |
| 32 | Replacement of 1 by 4 HP Condenser Fan Motor | b 1 4 HP Condenser Fan Motor condensing fan motor | 5 | nos | [email protected] | 270 | |
| 33 | Replacement of 1 by 35 HP Indoor Blower Motor | c 1 35 HP Indoor Blower Motor | 5 | nos | [email protected] | 270 | |
| 34 | Replacement, Fixing of Copper wiring kit | Replacement Fixing of following items in existing 1.5 2.0 TR capacity Split AC unit suitable for operation on Single phase, 240 Volt, AC Supply, testing, commissioning etc. complete as reqd. a Copper wiring kit | 5 | nos | [email protected] | 270 | |
| 35 | Replacement , Fixing of Condensor Fan Blade | b Condensor Fan Blade Transparent PVC Metallic | 8 | nos | [email protected] | 270 | |
| 36 | Replacement Fixing of PCB repairing for remote control | c PCB repairing for remote control of A C unit | 5 | nos | [email protected] | 270 | |
| 37 | Replacement,Fixing of SITC of new PCB for remote control | d SITC of new PCB for remote control of AC unit | 5 | nos | [email protected] | 270 | |
| 38 | Replacement, Supply, Fixing of Remote Hand Set | e Supply Fixing of Remote Hand Set with enclosure Hitchi LG Voltas gujral | 5 | nos | [email protected] | 270 | |
| 39 | S, Fixing 20 mm dia PVC drain pipe in recess | S Fixing 20 mm dia PVC drain pipe in recess or on surface for drainage of split AC units i c connections etc complete as reqd. | 30 | mtr | [email protected] | 270 | |
| 40 | SFixing PVC flexible pipe to cover the refrigerant pipes | S Fixing PVC flexible pipe to cover the refrigerant pipes and power cables in the existing wall on surface M S Tray with saddles, screws including S F clamps etc. as required. a 50 mm Dia | 15 | mtr | [email protected] | 270 | |
| 41 | Pdg. and installing size 22 Gauge of 1 4 inch size nominal dia | Pdg. and installing following size 22 Gauge of copper refrigerant pipe along with insulation including cutting bending, jointing, brazing , testing and commissioning etc as required. a 1 4 inch size nominal dia | 10 | mtr | [email protected] | 270 | |
| 42 | Pdg. and installing size 22 Gauge of 5 8 inch size nominal dia | b 5 8 inch size nominal dia | 10 | mtr | [email protected] | 270 | |
| 43 | Replacement of condesnser coil 1.5, 2.0 TR split AC unit | Replacement of condesnser coil of existing outdoor units of 1.5 2.0 TR split AC unit with new copper coil i c removing the old coil nut bolt installing the new coil brazing testing commissioning etc complete as reqd. | 2 | nos | [email protected] | 270 | |
| 44 | Replacement of cooling coil 1.5, 2.0 TR split AC unit | Replacement of cooling coil 1.5 2.0 TR split AC unit i c removong the old coil nut bolt fixing the new coil refrigerant piping brazing connetion testing commissioning etc as reqd. | 2 | nos | [email protected] | 270 | |
| 45 | Replacement of existing faulty, unseriviceable 1.5 TR Indoor Units | Replacement of existing faulty unseriviceable 1.5 TR Indoor Units of Split AC Units by supplying new 1.5 TR Indoor Unit, suitable for operation on 230 V AC supply, complete with blower, cooling coil, filters, controls and all accessories and remote control, etc. complete as reqd. Make M S Hitachi Blue Star Carrier Voltas make | 2 | nos | [email protected] | 270 | |
| 46 | S fixing of MS frame a 40mmx40mmx5 mm MS angle iron | Supplying, fabricating and fixing of MS frame made out of following members i c cutting, welding, grouting and painting the MS members etc. complete as reqd. a 40mmx40mmx5 mm MS angle iron. | 12 | mtr | [email protected] | 270 | |
| 47 | b 40mmx5mm MS flat | b 40mmx5mm MS flat. | 7 | mtr | [email protected] | 270 | |
| 48 | Sfixing of powder coated prefabricated wall floor mounting stand | Supply and fixing of powder coated prefabricated wall floor mounting stand for out door unit made out of M.S.sheet M.S. angle iron of suitable size i c cutting, welding, painting and grouting etc. complete as required. | 2 | job | [email protected] | 270 | |
| 49 | Repairing of inveter type split AC a 1.5 TR Inverter SAC PCB card | Repairing of faulty 1.5 TR inveter type split AC with repairing of following item i c dismantling, repairing and refixing , testing commissioning etc complete as reqd. a 1.5 TR Inverter SAC PCB card | 3 | job | [email protected] | 270 | |
| 50 | b 1.5 TR Inverter SAC Outdoor motor | b 1.5 TR Inverter SAC Outdoor motor | 2 | job | [email protected] | 270 | |
| 51 | c 1.5 TR Inverter SAC Indoor motor | c 1.5 TR Inverter SAC Indoor motor | 2 | job | [email protected] | 270 | |
| 52 | Shifting and reinstallation of 3 phase tower type Split AC unit | Shifting and reinstallation of existing 3.0 TR , 3 phase tower type Split AC unit including shifting charges for shifting of indoor and outdoor unit from one place to another in the same bldg., mounting fitting of indoor and outdoor units at proper locations, suitable electrical connection wiring etc. complete as required. | 2 | job | [email protected] | 270 | |
| 53 | SITC of vaccumization and Nitrogen testing a 12.7 mm dia. | Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft hard drawn copper refrigerant piping for AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing brazing including accessories, insulated with XPLE Class O tubular insulation with Class O closed cell elastomeric nitrite rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required. a 12.7 mm dia. OD with tube thickness 1.2 mm with 19 mm thick insulation | 6 | mtr | [email protected] | 270 | |
| 54 | b 19.10 mm dia. | b 19.10 mm dia. OD with tube thickness 1.2 mm with 19 mm thick insulation | 6 | mtr | [email protected] | 270 | |
| 55 | Sfixing of control cum transmission wiring a 4c x 4 sqmm | Supply and fixing of control cum transmission wiring and AC power supply cable of shielded Copper conductor for looping between indoor and outdoor units complete as manufacturers standard compete as required. A 4c X 4 sqmm PVC insulated copper conductor cable | 6 | mtr | [email protected] | 270 | |
| 56 | SFixing of PVC insulated PVC sheathed copper conductor | Supply Fixing of PVC insulated PVC sheathed copper conductor armoured cable of 5c X4 sqmm size of 1.1Kv grade on surface recess of wall with MS saddle complete as required. | 5 | mtr | [email protected] | 270 | |
| 57 | Sfixing FP sheet steel 25 32 A 415 V C curve FP MCB | Supplying and fixing FP sheet steel enclosure on surface recess along with 25 32 A 415 V C curve FP MCB complete with connections, testing and commissioning etc. as required. Havells Legrand or SS Makes | 2 | job | [email protected] | 270 | |
| 58 | Minor civil existing Brick Stone RCC wall having approx. thickness of 1 Metre for fixing | Minor civil i.e. making hole in the existing Brick Stone RCC wall having approx. thickness of 1 Metre for fixing the pipe repairing the same with sand cement as per direction of Engineer in charge etc., complete as required with same type of material. | 2 | job | [email protected] | 270 | |
| 59 | Providing and filling of Refrigerant R 410 R 32 as required gas | Providing and filling of Refrigerant R 410 R 32 as required gas approx 4.5kg in the circuit of 3.0TR tower type AC as , up to the required pressure, and holding N2 pressure in circuit for 24 hours for lekage check and vacumm in circuit including testing commissioning etc complete as required. | 2 | job | [email protected] | 270 | |
| 60 | Pfixing of GI frame tray of 24 guage of size 3feetx1.5 feet | Providing and fixing of GI frame tray of 24 guage of size 3feetx1.5 feet with hight of 1inch on edges with PVC collection nipple in tray for window AC drain collection and provision of fixing below window AC frame with GI wire etc complete as reqd. | 8 | job | [email protected] | 270 | |
| 61 | Supply and fixing of AC changeover Sequence | Supply and fixing of AC changeover Sequence Timer for cyclic operation of two any type of Air Conditioners, automatic switch over, 2 Channels Power Voltage 220V i c 4 sqmm cable connection etc complete as reqd. | 2 | job | [email protected] | 270 |
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Start
30-May-2025, 4:00 pm
End
31-May-2025, 4:00 pm
Duration: 24 hours
Reverse Auction Document
✅ RA concluded. Check financial results for final rankings.
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | BRIGHT REFRIGERATION WORKS Under PMA | - | 22-05-2025 22:31:44 | |
| 2 | PUSHPAK COMMODEAL PRIVATE LIMITED Under PMA | - | 26-05-2025 14:43:43 | |
| 3 | star electric works Under PMA | - | 26-05-2025 16:52:53 |
These are the final prices after the reverse auction event. Prices may be lower than initial bids.
| Rank | Seller | Final Price | Item |
|---|---|---|---|
| L1 | BRIGHT REFRIGERATION WORKS(MSE,MII) Under PMA Winner | ₹3,53,700 | Item Categories : Servicing of 1.5, 2.0 TR Window A.C. Units,Installation of 1.5, 2TR window type A.C. in the existin |
| L2 | star electric works (MSE,MII) Under PMA | ₹3,55,182 | Item Categories : Servicing of 1.5, 2.0 TR Window A.C. Units,Installation of 1.5, 2TR window type A.C. in the existin |
🎉 L1 Winner
BRIGHT REFRIGERATION WORKS(MSE,MII) Under PMA
Final Price: ₹3,53,700
Key insights about DELHI tender market
The eligibility requirements include being a registered entity with the relevant authority, demonstrating experience in servicing and installing air conditioning systems, and holding all necessary certifications and licenses. Bidders must possess the ability to manage the servicing and repairing of a total of 398 A.C. units as specified in the tender.
The technical specifications include proficiency in servicing components of 1.5 and 2.0 TR window A.C. units. Bidders should ensure they can perform tasks such as leak detection and repair, replacement of parts like fans and coils, and other system upgrades. Adherence to quality standards set by the industry is essential for successful bidding.
The Earnest Money Deposit (EMD) details are included in the financial requirements of the tender. All bidders must provide a specified amount as EMD to confirm their serious intent in the bidding process. This amount is held to ensure compliance with the contract terms and is typically refundable upon satisfactory conclusion of the contract obligations.
Documents should be submitted electronically through the designated portal as outlined in the tender documentation. Bidders must ensure adherence to submission guidelines, including file format and completeness, to avoid disqualification.
MSEs and startups can avail themselves of special provisions within this tender to foster inclusive participation. These benefits can include preferential treatment in the evaluation process, extended payment terms, and assistance in meeting the documentation requirements that support their bidding efforts under the tender.
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS