| Category | Specification | Requirement |
|---|---|---|
| PERFORMANCE (INFRARED / NON-CONTACT) | Lowest Measurable Temperature (Infrared Non-contact) | -70, -60, -50, -40, -35, -33, -32, -30 Or lower |
| PERFORMANCE (INFRARED / NON-CONTACT) | Highest Measurable Temperature (Infrared Non-contact) | 350, 360, 380, 400, 450, 500, 535, 550, 600, 650, 700, 750, 760, 800, 900, 950, 1000, 1050, 1100, 1200, 1300, 1370, 1400, 1470, 1500, 1600, 1700, 1800, 1850, 1900, 2000, 2100, 2200, 2300, 2400, 2500, 2600, 2700, 2800, 2900, 3000 Or higher |
| PERFORMANCE (INFRARED / NON-CONTACT) | Display Resolution | 0.1 Or lower |
| PERFORMANCE (INFRARED / NON-CONTACT) | Basic Accuracy (±) | 0.5, 0.75, 1 Or lower |
| PERFORMANCE (INFRARED / NON-CONTACT) | Spectral Range (in micrometer) | 5 TO 14 |
| PERFORMANCE (INFRARED / NON-CONTACT) | Optical Resolution-Far field (Distance to spot ratio) (calculated at 90% energy) | 8:1, 10:1, 12:1, 13:1, 20:1, 25:1, 30:1, 50:1, 60:1, 70:1, 75:1, 100:1, 150:1, 200:1, 250:1 Or higher |
| PERFORMANCE (INFRARED / NON-CONTACT) | Emissivity (W/m2) | Continuously Adjustable from 0.1 to 1.00 |
| DISPLAY / DATA OUTPUT | Type of Display | LCD |
| DISPLAY / DATA OUTPUT | Back-light display | No |
| DISPLAY / DATA OUTPUT | Display Size(in inch) | 2.0 to 2.4, 2.5 to 2.9, 3.0 to 3.4, 3.5 to 3.9, 4.0 to 4.4, 4.5 to 4.9, 5.0 to 5.4, 5.5 to 5.9, 6.0 to 6.4, 6.5 to 6.9 Or higher |
| DISPLAY / DATA OUTPUT | Data Output to other devices | No |
| DISPLAY / DATA OUTPUT | Connectivity / interface | NA |
| DISPLAY / DATA OUTPUT | Data point logging capability (on board memory) | 0, 10, 12, 20, 30, 40, 50, 100, 200, 500, 1000, 2000, 3000, 4000, 4999 Or higher |
| BATTERY | Power Source | Alkaline Batteries (Non-Rechargeable) |
| BATTERY | Battery Size, if Non Rechargeable Battery | AA |
| BATTERY | Battery Chemistry | Alkaline |
| BATTERY | Battery Chargers for Rechargeable Batteries - inclusive in the scope of supply | Yes |
| BATTERY | Number of Batteries required for operation | 2 |
| BATTERY | Number of Batteries supplied (Inclusive in the Scope of Supply) | 1 |
| BATTERY | Battery back-up time under continuous use | 8, 10, 12, 16, 20, 24, 30, 36, 48 Or higher |
| SALIENT FEATURES / FUNCTIONS | Salient Features / Functions | Low Battery indication |
| ACCESSORIES | Standard accessories inclusive in the scope of supply | Carrying Case |
| GENERIC | Built-in laser for precisely aiming the target | Yes |
| GENERIC | Laser Class | Class II |
| GENERIC | Laser sighting | Single-point laser |
| GENERIC | Optional/User Guide/Manual | Yes |
| OPERATING CONDITIONS / INGRESS PROTECTION | Minimum Operating Temperature | -10, -15, -20, -25, -30 Or lower |
| OPERATING CONDITIONS / INGRESS PROTECTION | Maximum Operating Temperature | 50, 55, 60, 65, 70 Or higher |
| OPERATING CONDITIONS / INGRESS PROTECTION | Maximum Operating Humidity at 40 deg C - Non-condensing (Rh) | 90, 95 Or higher |
| OPERATING CONDITIONS / INGRESS PROTECTION | Maximum Operating Altitude (meters above MSL) | Upto 500, 501 to 2000, 2001 to 3000 Or higher |
| OPERATING CONDITIONS / INGRESS PROTECTION | Ingress Protection | IP 40, IP 54, IP 65, IP 66, IP 67 Or higher |
| WARRANTY | Warranty | 1.0 |
| CERTIFICATION / TEST REPORTS | Compliance to Standards | EN 61326-1, EN 61326-2 Electromagnetic Compatibility, EN/IEC 61010-1 General Safety |
| CERTIFICATION / TEST REPORTS | Hazardous location (Intrinsically Safe / non-incendive) approval | No |
| CERTIFICATION / TEST REPORTS | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | No |
| CALIBRATION | Calibration Certificate issuing authority | OEM Certificate |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS