Motor Protection Circuit Breaker (MPCB)
Rail Wheel Factory Yelahanka
BANGALORE, KARNATAKA
Progress
Quantity
6
Bid Type
Two Packet Bid
Rail Wheel Factory Yelahanka (Indian Railways) seeks supply of an 80A Motor Protection Circuit Breaker (MPCB) meeting ISI marking and IEC 60947-4-1/IEC 60947-2 compliance for 3-pole, 415/690 V AC systems. The unit carries a rated breaking capacity of 100kA with AC-3 duty, and includes 1NO+1NC auxiliary contacts with 4 A @ 440 V AC auxiliary current. The product mounts on 35 mm DIN rail and features IP20 protection with screw/spring terminals. Bidders must quote against the option-clause delivery terms allowing ±25% quantity variation and adhere to the original/extended delivery timelines from the last delivery order. The tender specifies OEM or authorized dealer quoting, with ISI certification proof and test certificates on demand. Bangalore, Karnataka-based procurement emphasizes IEC and ISI compliance for railway electrical protection devices.
Product: 80A Motor Protection Circuit Breaker (MPCB)
Category: ISI marked, IEC 60947-4-1/60947-2 compliant
Ratings: 80 A, 3 poles, 415/690 V AC, 50 Hz
Breaking capacity: 100 kA
Duty: AC-3
Terminals: screw clamp or spring
Auxiliary: 1NO+1NC, 4 A @ 440 V AC, AC-15
Mounting: DIN rail 35 mm; IP20 protection
Warranty: 18 months from supply or 12 months from commissioning
Quantity may be increased/decreased by 25% at contract placement and during currency
Delivery period anchored to last original delivery order date with extension rules
Only OEMs or authorized dealers may quote; ISI and test certificates required on demand
GeM PO and GST-compliant invoicing; tested certificates; GSTIN, HSN, and place of supply must match
Delivery to commence as per order date; option-clauses may extend delivery with minimum 30 days' additional time
Applicable LD details not provided; ensure compliance with standard GeM procurement penalties
Authorized OEM or OEM-authorized dealer for MPCBs
Evidence of ISI marking and IEC conformity certificates
Experience in supplying railway-grade protection devices
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Motor Protection Circuit Breaker (MPCB) (Q3)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Rail Wheel Factory Yelahanka
BANGALORE, KARNATAKA
West Central Railway
JABALPUR, MADHYA PRADESH
N/a
BUDAUN, UTTAR PRADESH
North Western Railway
JODHPUR, RAJASTHAN
Rail Wheel Plant Bela
SARAN, BIHAR
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Certification and Standards | ISI marked | Yes |
| Certification and Standards | All Specification conforming to | IEC:60947 part-2:2003 *latest |
| Working Properties | Breaking Capacity, kA | 100 Or higher |
| Working Properties | Utilization Category (IEC947 - 4 - 1 / 947 - 2) | AC - 3 |
| Working Properties | Rated Current, A | 80, 85, 90, 95, 100 Or higher |
| Test Reports | Copies of test Reports/certificates and other certifications to be furnished to buyer on demand at time of supplies | Yes |
| Test Reports | Availability of test report from central Govt/ NABL/ILAC accredited lab covering all parameters | Yes |
Discover companies most likely to bid on this tender
GST registration certificate
PAN card details
Experience certificates for similar MPCB supply
Financial statements or turnover proof
EMD deposit proof (if applicable in GeM process)
Technical bid documents confirming ISI marking and IEC conformity
OEM authorization / authorized dealer certificate
Test certificates proving compliance with IEC standards
Key insights about KARNATAKA tender market
Bidders should submit OEM authorization or authorized dealer proof, ISI marking, and IEC conformity certificates, with a test report for 80 A, 3-pole MPCB. Include GSTIN, HSN, and place of supply in the invoice, plus completion of the GeM PO documentation and delivery terms.
Required documents include GST certificate, PAN, experience certificates for railway-grade MPCBs, financial statements, OEM authorization, ISI and IEC test certificates, and payment documentation consistent with GeM PO and invoicing rules.
MPCB must comply with IEC 60947-4-1 and IEC 60947-2 (latest revisions) and carry ISI marking. Test certificates proving conformity must be provided on demand during supply.
The MPCB must provide a rated breaking capacity of 100 kA for short-circuit conditions, suitable for AC-3 duty, and compatible with 415/690 V AC, 50 Hz systems.
Delivery can be extended under the option clause for ±25% quantity changes. Additional time is calculated as (increased quantity/original quantity) × original delivery period, with a minimum of 30 days.
Warranty is 18 months from the date of supply or 12 months from the date of commissioning, whichever is earlier, with coverage as per supplier terms and railway conditions.
The MPCB must include 1NO+1NC auxiliary contacts, rated at 4 A @ 440 V AC, with AC-15 duty, and be compatible with DIN rail mounting (35 mm) and IP20 protection.
Submit OEM authorization or proof of being an authorized dealer, along with original equipment manufacturer documentation showing ISI and IEC compliance, and provide test certificates proving conformity to the specified standards.
Rail Wheel Factory Yelahanka
📍 BANGALORE, KARNATAKA
Rail Wheel Factory Yelahanka
📍 BANGALORE, KARNATAKA
Rail Wheel Factory Yelahanka
📍 BANGALORE, KARNATAKA
Rail Wheel Factory Yelahanka
📍 BANGALORE, KARNATAKA
Rail Wheel Factory Yelahanka
📍 BANGALORE, KARNATAKA
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS