TITLE 1,TITLE 2,TITLE 3,TITLE 4,TITLE 5,TITLE 6,TITLE 7,TITLE 8,TITLE 9,TITLE 10,TITLE 11,TITLE 12,
Electronics Corporation Of India Limited
HYDERABAD, TELANGANA
Progress
Quantity
156
Category
Title 10
Bid Type
Two Packet Bid
Indian Army invites bids for Title 1, Title 2, Title 3, Title 4, Title 5, Title 6, Title 7, Title 8, Title 9, Title 10, Title 11, Title 12, Title 13, Title 14, Title 15, Title 16, Title 17 in WEST DELHI, DELHI. Quantity: 156. Submission Deadline: 24-02-2026 18: 00: 00. Submit your proposal before the deadline.
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
Electronics Corporation Of India Limited
HYDERABAD, TELANGANA
N/a
Bhopal Municipal Corporation, Madhya Pradesh
Indian Army
NEW DELHI, DELHI
Joint Venture Of Cil, Ntpc, Iocl, Fcil & Hfcl
GORAKHPUR, UTTAR PRADESH
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Title 1 | M and L for searching fault location of HT UG cable 11000 Volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse ECHO fault locator with frequency distance calculator etc incl transportation of machinery Excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of Engineer in charge Note a Charges of cable fault locator and DG set including transportation charges deemed to be included in the quoted rate b Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item | 3 | each job | sumitkumar@132 | 30 |
| 2 | Title 2 | Supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core X 120 minus 185 Sqmm XLPE cable of 11000 volts E grade complete all as specified and directed Note Cost of cutting of existing end termination joint deemed to be included in unit rate | 2 | each | sumitkumar@132 | 30 |
| 3 | Title 3 | M and L for cable jointing kit for 11 KV Earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core XLPE armored aluminum conductor cable complete all as specified and directed | 3 | each | sumitkumar@132 | 30 |
| 4 | Title 4 | Supplying and laying in repair XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 Sqmm x 3 core complete all as specified and directed | 16 | rm | sumitkumar@132 | 30 |
| 5 | Title 5 | Supply and fixing in repair MCCB 400 Amps 3 pole 415 Volt 36 KA including under voltage over voltage relay with adjutable thermal setting 80% Minuse 100% all as specified and directed | 1 | each | sumitkumar@132 | 30 |
| 6 | Title 6 | M and L for complete repairing Serviceing of HT 11 KV Vaccum circuit breaker VCB after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with HT insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal AC DC circuit wiring repair servicing of breaker trolly including motorized operating mechanism CT PT power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow Over Current Earth Fault Differential in sequence from down streem to receiving Sub stn for accuracy and effective functioning of VCB complete all as specified and as directed Note Nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective HT 11 KV 2 Amp fuse carrier oiling greasing to charging spring replacement of HRC fuse 110 220 volt 5 Amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate Replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items | 1 | each job | sumitkumar@132 | 30 |
| 7 | Title 7 | Supply and fixing Heater 230 volts AC 60 watt for 11 KV HT VCB panel complete all as specifed and as directed Make Heatco Vileco Electrical | 2 | each | sumitkumar@132 | 30 |
| 8 | Title 8 | Supply and fixing in replecement of Spring charging Gear for 11KV VCB panel suitable for 630 400 Amp complete all as specified and directed | 2 | each | sumitkumar@132 | 30 |
| 9 | Title 9 | Supply and fixing vacuum interputer for HT11 KV VCBs 630 400 Amps brakding capacity 13point 1 KA suitable for Alstom make VCB complete all as specified and as directed | 1 | each | sumitkumar@132 | 30 |
| 10 | Title 10 | Taking down and repairing overhauling of air break gang operated switch with DO fuse unit 200 Amp 400 Amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after repair including proper allienment complete all as directed Note Warn out component insulators shall be measured and paid separately | 1 | each job | sumitkumar@132 | 30 |
| 11 | Title 11 | Supply and fixing replacement of Female contact or fixed contact heavy duty and high conductive metal complete capacity 200A 400 Amp11 KV complete all as specified and directed | 2 | set of three | sumitkumar@132 | 30 |
| 12 | Title 12 | Supply and fixing in replacement of Male contact or Moving contact heavy duty and high conductive metal complete capacity 200A 400Amp 11 KV complete all as specified and directed | 2 | set of three | sumitkumar@132 | 30 |
| 13 | Title 13 | Excavation in trenches not exceeding 1 point 5 m wide and and not exceeding 1 point 5 m depth in soft soil and getting out all as specified and directed | 6 | cum | sumitkumar@132 | 30 |
| 14 | Title 14 | Returning, filling in with excavated soil including spreading levelling watering and well ramming in layers not exceeding 25 cm all as specified and directed | 5 | cum | sumitkumar@132 | 30 |
| 15 | Title 15 | Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1 point 5 m above the starting point as specified and directed | 2 | cum | sumitkumar@132 | 30 |
| 16 | Title 16 | Supply and laying sand cushioning for cable protection 8cm for bedding and 15 cm after laying the cable in trench and compaction upto 18 cm 18cm shall be catered for measurement purpose in trenches all as specified and directed | 1 | cum | sumitkumar@132 | 30 |
| 17 | Title 17 | Supply and laying un reinforced precast concrete LV cable cover class Type I with 250 X 150 X 40 mm as specified and directed | 106 | each | sumitkumar@132 | 30 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS