Supply of Surge Protection Device as per rquirements,Supply Copper plate as per rquirements,Supply
Airports Authority Of India
LAKHIMPUR, ASSAM
Progress
Quantity
1881
Category
Supply, Installation, Testing and Commissioning of Primary Protection CLASS B or Type 2 Supply and Installation of Surge Protection Device
Bid Type
Two Packet Bid
Airports Authority Of India has released a public tender for Supply, Installation, Testing and Commissioning of Primary Protection CLASS B or Type 2 Supply and in DHUBRI, ASSAM. Quantity: 1881. Submission Deadline: 22-04-2025 15: 00: 00. Download documents and apply online.
Main Document
BOQ
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Airports Authority Of India
LAKHIMPUR, ASSAM
North East Frontier Railway
KAMRUP, ASSAM
North East Frontier Railway
TINSUKIA, ASSAM
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of Primary Protection CLASS B or Type 2 Supply and Installation of Surge Protection Device | Supply, Installation, Testing and Commissioning of PRIMARY PROTECTION (CLASS B / Type 2) SUPPLY & INSTALLATION of SURGE PROTECTION DEVICE (SPD) having 100KA 10/350 micro seconds neutral to earth, 100 KA 10/350 micro sec line to neutral 25KA with limiting voltage less than 1.5 KV shall be provided on the mains power entry point at the incomers before UPS & shall be of modular type - as per Technical Specification given in Tender Document & BOQ. | 2 | nos | buycon395.aai.as | 120 |
| 2 | Supply, Installation, Testing and Commissioning of Second Stage Protection CLASS C or Type 3 Supply and Installation | Supply, Installation, Testing and Commissioning of SECOND STAGE PROTECTION (CLASS C/Type 3) SUPPLY & INSTALLATION of (63A Filter 3 phase, 415 V) NEUTRAL SURGE PROTECTION DEVICE - - as per Technical Specification given in Tender Document & BOQ. | 2 | nos | buycon395.aai.as | 120 |
| 3 | Supply, Installation, Testing and Commissioning of Supporting tube for HVI long Conductor | Supply, Installation, Testing and Commissioning of Supporting tube for HVI long Conductor with air-termination tip length 2000 mm, GRP/StSt GRP/StSt supporting tubes with internal sealing end and EB spring element for the HVI long Conductor for maintaining the separation distance to electrically conductive parts as per DIN EN 62305 (VDE 0185-305-3) - as per Technical Specification given in Tender Document & BOQ. | 7 | nos | buycon395.aai.as | 120 |
| 4 | Supply, Installation, Testing and Commissioning of Elevation pole made | Supply, Installation, Testing and Commissioning of Elevation pole made of GI- material having ISI-marking. Consists of the FRP 2 mtr following(for a typical 17 m mast)3mtr 50mm dia GI pipe Reducer, M20 thread Base plate(200x200x10mm), mounting bracket, clamps and all required fixing accessories supplied in compliance with IEC 62561 - 1 - as per Technical Specification given in Tender Document & BOQ. | 7 | nos | buycon395.aai.as | 120 |
| 5 | Supply, Installation, Testing and Commissioning of Fixing clamp with tensioning strap | Supply, Installation, Testing and Commissioning of Fixing clamp with tensioning strap for fixing Combi supporting tubes, e.g. to the antenna mast or other pipes. With spacer, length 30 mm, for adjusting, e.g. antenna holders - as per Technical Specification given in Tender Document & BOQ. | 21 | nos | buycon395.aai.as | 120 |
| 6 | Supply, Installation, Testing and Commissioning of High voltage resistant insulated down conductor | Supply, Installation, Testing and Commissioning of High-voltage-resistant insulated down conductor for keeping the separation distance of 75 cm to electrically conductive parts according to IEC/EN 62305-3 - as per Technical Specification given in Tender Document & BOQ. | 105 | mtr | buycon395.aai.as | 120 |
| 7 | Supply, Installation, Testing and Commissioning of Conductor holder for installation | Supply, Installation, Testing and Commissioning of Conductor holder for installation of the HVI Conductor in explosion hazardous areas Ex zone 1 (gases, vapours, mists) as well as Ex zone 21. Material of conductor holder- StSt, Conductor holder support Rd- 20-23 mm. | 105 | nos | buycon395.aai.as | 120 |
| 8 | Supply, Installation, Testing and Commissioning of Connection elements for sealing the HVI long Conductor at both ends, to implement the sealing end of the conductor outside the supporting tube | Supply, Installation, Testing and Commissioning of Connection elements for sealing the HVI long Conductor on both ends, for implementing the sealing end of the conductor in the supporting tube (head piece) and connection element for connection to other parts of the external lightning protection system or earth-termination system. | 7 | nos | buycon395.aai.as | 120 |
| 9 | Supply, Installation, Testing and Commissioning of Connection elements for sealing the HVI long Conductor at both ends, to implement the sealing end of the conductor outside the supporting tube | Supply, Installation, Testing and Commissioning of Connection elements for sealing the HVI long Conductor at both ends, to implement the sealing end of the conductor outside the supporting tube (head piece for connection plate) and connection element for connecting to other parts of the external lightning proteciton system or earthing system (incl. two heat-shrinkable sleeves and four cable ties). | 7 | nos | buycon395.aai.as | 120 |
| 10 | Supply, Installation, Testing and Commissioning of Fixing kit for HVI long Conductor | Supply, Installation, Testing and Commissioning of Fixing kit for HVI long Conductor black / grey. Material- StSt / Al, Connection plate support- square hole 13 mm. | 7 | nos | buycon395.aai.as | 120 |
| 11 | Supply, Installation, Testing and Commissioning of EB connection element for discharging the electric field | Supply, Installation, Testing and Commissioning of EB connection element for discharging the electric field of the HVI long Conductor in the sealing end range. | 7 | nos | buycon395.aai.as | 120 |
| 12 | Supply, Installation, Testing and Commissioning of Lightning strike counter | Supply, Installation, Testing and Commissioning of Lightning strike counter for digitally recording impulse currents The counter is preferably installed on the down conductors of the lightning protection system or between the equipotential bonding bar and the earth-termination system - as per Technical Specification given in Tender Document & BOQ. | 2 | nos | buycon395.aai.as | 120 |
| 13 | Supply, Installation, Testing and Commissioning of UNI Disconnecting Clamps | Supply, Installation, Testing and Commissioning of UNI Disconnecting Clamps with intermediate plate as test link for round and flat conductor of Material- StSt, Material thickness- 2.5 mm, with clamping range- Rd / Fl 10 / 30 mm, & Complied as per Standard EN 62561-1. | 7 | nos | buycon395.aai.as | 120 |
| 14 | Supply, Installation, Testing and Commissioning of Copper bonded rod with Low carbon steel | Supply, Installation, Testing and Commissioning of Copper bonded rod with Low carbon steel, high tensile strength copper bonded rod with min 254 microns of copper plating, UL listed with company name marked on rod - as per Technical Specification given in Tender Document & BOQ. | 7 | nos | buycon395.aai.as | 120 |
| 15 | Supply, Installation, Testing and Commissioning of POE surge arrester | Supply, Installation, Testing and Commissioning of POE surge arrester of class D M surge arrester, class D SPD class type 2 / P1 Tested to EN 61643-21 For universal use according to EN 50173 for all data services up to 57 V d.c. For protecting four pairs of data network interfaces via RJ45 sockets, for single-user application or application in distribution cabinets, space-saving, width of 19 mm. Type - DPA M CLD RJ45B 48. NABL/KEMA Certified Make - Dehn | 5 | nos | buycon395.aai.as | 120 |
| 16 | Supply, Installation, Testing and Commissioning of RJ45B 48 surge arrester | Supply, Installation, Testing and Commissioning of RJ45B 48 surge arrester of class D M surge arrester, class D SPD class type 2 / P1 Tested to EN 61643-21 For universal use according to EN 50173 for all data services up to 57 V d.c. For protecting four pairs of data network interfaces via RJ45 sockets, for single-user application or application in distribution cabinets, space-saving, width of 19 mm. Type DPA M CLD RJ45B 48. NABL/KEMA Certified Make - Dehn | 5 | nos | buycon395.aai.as | 120 |
| 17 | Supply, Installation, Testing and Commissioning of Earthing with copper earth plate | Supply, Installation, Testing and Commissioning of Earthing with copper earth plate 600 mm X 600 mm X 3.15 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.Conventional earthing using copper plates as per IS 3043 & as per RCDU-DVOR-EARTHING-LAYOUT-2024 | 17 | set | buycon395.aai.as | 120 |
| 18 | Supply, Installation, Testing and Commissioning of 25 mm X 5 mm copper strip | Supply, Installation, Testing and Commissioning of 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode in 40 mm dia G.I.pipe from earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) | 300 | mtr | buycon395.aai.as | 120 |
| 19 | Supply, Installation, Testing and Commissioning of 4mm dia copper wire | Supply, Installation, Testing and Commissioning of 4mm dia copper wire with clamps/tie with GI pipe of LA and connection/termination with copper body of LA and copper strip at bottom of LA through nut/bolt/spring washer etc. as required, for earthing etc. complete as required | 500 | mtr | buycon395.aai.as | 120 |
| 20 | Supply, Installation, Testing and Commissioning of Providing joints by using brazing technique | Supply, Installation, Testing and Commissioning of Providing joints by using brazing technique on 25 mm X 5 mm copper/GI strip on surface or in recess for connections to another copper/GI earth strip for interconnection to all earths of Lightening Arrestors, counterpoise , Equipment and Electrical power supply earthing etc. as required. | 50 | nos | buycon395.aai.as | 120 |
| 21 | Supply, Installation, Testing and Commissioning of Low Impedance Digital Grounding System | Supply, Installation, Testing and Commissioning of Low Impedance Digital Grounding System 240kA Three Phase four wire LIDGS 4th Generation equipment Grounding & bonding system with built in 100% Lightning and Surges, static charge, Noises, ESD, EPR and abnormal electrical characteristics eliminator which enter from power and other service lines and ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V, a digital 3 Digit LCD Impulse real Date time Counter with threshold of IKA, selfhealth visual status indicator, built Zero leakage Current based solution - as per Technical Specification given in Tender Document & BOQ. | 1 | nos | buycon395.aai.as | 120 |
| 22 | Design, Manufacturing, supply of FILK or NABL tested and Environmentally friendly aerosol based fire suppression system | Design, Manufacturing, supply of FILK/ NABL tested and Environmentally friendly aerosol-based fire suppression system with EPA For SNAP Listing and comprising an electrically operated aerosol generator with shelflife of atleast 10 years having aerosol mass based on KFPA approved design concentration applicable for Fire Class A, B & C with Volumetric Design Consideration. The generator shall be electrically actuated by the Fire Alarm cum Release Panel. The quantity of Aerosole generators shall be decided according to volume/dimension of existing Battery room above false flooring having Volume Approx. 140 Cubic mtr.along with KFPA approved concentration of 100 gm/cu.Mtr. aerosole duly approved by OEM and NFPA 2010 shall be approved from EIC prior to starting of the works. The aerosol generated shall be potassium-based, providing effective fire suppression while being environmentally friendly with zero ozone depletion potential and zero global warming potential. The system shall be supplied with necessary accessories complete as required. Dimension of Space- 139.285 Cubic Mtr 3 Rooms (Equipment Room, UPS Room & Electrical Room) | 140 | c mtr | buycon395.aai.as | 120 |
| 23 | Installation, testing, and commissioning of above aerosole generators | Installation, testing, and commissioning of above aerosole generators as per item no-23 in the room as per site requirement having Volume Approx.139.285 Cubic Mtr. | 3 | job | buycon395.aai.as | 120 |
| 24 | SITC OF 6 kg ABC powder type low pressure carytridge type fire extinguishers | SITC OF 6 kg ABC powder type low pressure carytridge type fire extinguishers. | 6 | nos | buycon395.aai.as | 120 |
| 25 | Supply, Installation, Testing and Commissioning of Conventional agent release control panel | Supply, Installation, Testing and Commissioning of Conventional agent release control panel with battery back up for 30 minutes in alarm condition. Panel shall be of 02 zones with necessary manual release switch, zone indication, fault indication, alarm display. Quoted rate shall include necessary battery & interconnections. Fire Detection Cum Release System with cross zoning of EN CERTIFIED heat & smoke detectors, EN CERTIFIED hooter cum strobe, EN CERTIFIED abort & release button. The EN listed Panel must have provision in addition for Health Monitoring system continuously stacking Agent Unit working on healhty condition. | 2 | nos | buycon395.aai.as | 120 |
| 26 | Supply, Installation, Testing and Commissioning Of Conventional type EN Listed Optical smoke detectors | Supply, Installation, Testing and Commissioning Of Conventional type EN Listed Optical smoke detectors complete with base, locking screw etc. both True ceiling & below FC, complies to EN Standardand as per Drawing. | 6 | nos | buycon395.aai.as | 120 |
| 27 | Supply, Installation, Testing and Commissioning Of Conventional type EN Listed Heat combination detectors | Supply, Installation, Testing and Commissioning Of Conventional type EN Listed Heat combination detectors (ROR and Fixed temperature) complete with base, locking screw etc. both True ceiling & below FC and as per drawing. | 6 | nos | buycon395.aai.as | 120 |
| 28 | Supply, Installation, Testing and Commissioning of EN Listed Manual release switch | Supply, Installation, Testing and Commissioning of EN Listed Manual release switch having body of polycarbonate alongwith backbox and necessary interconnection with the gas release panel. | 2 | nos | buycon395.aai.as | 120 |
| 29 | Supply, Installation, Testing and Commissioning of EN Listed Manual Abort switch | Supply, Installation, Testing and Commissioning of EN Listed Manual Abort switch having body of polycarbonate alongwith backbox with all necessary interconnection with the gas release panel. | 2 | nos | buycon395.aai.as | 120 |
| 30 | Supply, Installation, Testing and Commissioning of EN Listed Manual call point | Supply, Installation, Testing and Commissioning of EN Listed Manual call point, Break glass type and body of polycarbonate along with back box with necessary interconnection with the gas release panel. The manual call point must be connected in between any one selected zone. | 2 | nos | buycon395.aai.as | 120 |
| 31 | Supply, Installation, Testing and Commissioning of EN Listed Conventional Sounder cum strobe | Supply, Installation, Testing and Commissioning of EN Listed Conventional Sounder cum strobe with 24V DC, Audiable Sound 75 db at the rate of 1 mtr range (16 V DC). It is used for Fire, Burglar & Emergency Alarm System, Low current consume at the rate of 47 -73 mA Candela flashing every second, 4 candela settings 15/30/75/110cd output and 2 different tone audiable soundconventional Electronic Hooter cum sounder along with backbox, having body of polycarbonate - as per Technical Specification given in Tender Document & BOQ. | 2 | nos | buycon395.aai.as | 120 |
| 32 | Supply, Installation, Testing and Commissioning of Gas Discharge identification signage | Supply, Installation, Testing and Commissioning of GAS DISCHARGE identification signage. | 2 | nos | buycon395.aai.as | 120 |
| 33 | Supply, Installation, Testing and Commissioning of 2x1.5 sqmm fire alarm armoured cable | Supply, Installation, Testing and Commissioning of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. | 500 | mtr | buycon395.aai.as | 120 |
| 34 | Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable single loop fire alarm panel | Supply, Installation, Testing & Commissioning of micro processor based intelligent addressable single loop fire alarm panel, capable of supporting not less than 20 devices (including detectors), network communication card, LED / LCD display with touch screen or other keypad and events history log - as per Technical Specification given in Tender Document & BOQ. | 1 | nos | buycon395.aai.as | 120 |
| 35 | Supply, Installation, Testing and Commissioning of addressable Multi Photo Electric or Optical Smoke detector or Fire Sensor | Supply, Installation, Testing & Commissioning of addressable Multi Photo Electric / Optical Smoke detector/ Fire Sensor with mounting relay base as per specification and complete as required. | 16 | nos | buycon395.aai.as | 120 |
| 36 | Supply, Installation, Testing and Commissioning of addressable manual call point complete as required | Supply, Installation, Testing & Commissioning of addressable manual call point complete as required. | 1 | no | buycon395.aai.as | 120 |
| 37 | Supply, Installation, Testing and Commissioning of addressable horn cum strobe complete as required | Supply, Installation, Testing & Commissioning of addressable horn cum strobe complete as required. | 1 | no | buycon395.aai.as | 120 |
| 38 | Supply, Installation, Testing and Commissioning of response indicator | Supply, Installation, Testing & Commissioning of response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. | 16 | no | buycon395.aai.as | 120 |
| 39 | Supply, Installation, Testing and Commissioning of Auto dialer unit | Supply, Installation, Testing & Commissioning of Auto dialer unit with keypad having storage capacity of minimum 10 emergency numbers and one voice message and interconnection with Fire alarm control panel as per specification and complete as required. | 1 | no | buycon395.aai.as | 120 |
| 40 | Supply, Installation, Testing and Commissioning of 3 Phase or Type 1 plus 2 KEMA Certified Lightning current and Surge Protection Device | Supply, Installation, Testing and Commissioning of 3 Phase / Type1 plus 2 (KEMA Certified) Lightning current & Surge Protection Device at mains LT panel (3 phase, 415 V) for (L-N) Single-pole combined lightning current and surge arrester, Type 1 SPDThe device shall be non-exhausting metal encapsulated, spark gap based technology and tested as per latest and valid IEC 61643- 11 2011 or EN 61643-11 2012 standards - as per Technical Specification given in Tender Document & BOQ. | 1 | no | buycon395.aai.as | 120 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Key insights about ASSAM tender market
The eligibility requirements include being a registered legal entity with experience in the installation and commissioning of surge protection devices and related electrical systems. Bidders need to demonstrate prior similar project experience, technical capability, and financial stability to be considered for the evaluation process.
Bidders must provide relevant certificates for the products offered, ensuring compliance with safety and operational standards. This includes technical certifications for the surge protection devices and documentation of staff qualifications in related fields. Compliance with national electrical safety standards is also crucial.
The registration process can be completed through the designated government e-marketplace (GEM) platform. Prospective bidders should create an account, fill in necessary details, and upload required documents as per the tender submission guidelines to ensure a successful registration.
Bidders must submit all documents in the formats specified in the tender documentation. Typically, PDF and Excel formats are accepted for financial and technical documents, while technical specifications must be in line with the standards set out by the authorities.
Payment terms will be defined in the tender details, typically linked to project milestones. Bids will be evaluated based on a combination of technical specifications, financial proposals, and compliance with all requirements. Price evaluation will consider both quoted amounts and overall project viability for the best economic outcome.
Sign up now to access all documents
Main Document
BOQ
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS