Lumpsum supply of Barriers,line 2 Removal Installation and Commissioning,Lumpsum supply of Panel wi
Hindustan Petroleum Corporation Ltd
VISAKHAPATNAM, ANDHRA PRADESH
Menu
Progress
Quantity
301
Category
Supply and Installation commissiong 1
Bid Type
Two Packet Bid
A tender has been published for Council Of Scientific And Industrial Research (csir) Supply and Installation commissiong 1, Supply and Installation commissiong 2, Supply and Installation commissiong 3, Supply and Installation commissiong 4, Supply and Installation commissiong 5, Supply and Installation commissiong 6, Supply and Installation commissiong 7, Supply and Installation commissiong 8, Supply and Installation commissiong 9, Supply and Installation commissiong 10, Supply and Installation commissiong 11, Supply and Installation commissiong 12, Supply and Installation commissiong 13, Supply and Installation commissiong 14, Supply and Installation commissiong 15, Supply and Installation commissiong 16 in BANGALORE, KARNATAKA. Quantity: 301 by. Submission Deadline: 30-12-2025 12: 00: 00. Check eligibility and apply.
Hindustan Petroleum Corporation Ltd
VISAKHAPATNAM, ANDHRA PRADESH
Power Grid Corporation Of India Limited
HYDERABAD, TELANGANA
Marketing Division
BANKA, BIHAR
Purba Bharati Gas Private Limited
KAMRUP, ASSAM
Cpwd
GANDHI NAGAR, GUJARAT
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Supply and Installation commissiong 1 | Supply Installation testing and commissioning of 2TR 24000 BTU per Hour minimum BEE 3 star rated confirming to IS 1392 Part 2 2018 Inverter type Cassette Split ceiling mount air conditioner having wireless remote controller LED display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features Inbuilt Drain pump rotary scroll hermetically sealed compressor and initial charge of Eco friendly refrigerant Condensor and Evaporator coils of copper material suitable for operation on 230V 10 single phase 50Hz AC power supply The indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required | 2 | set | [email protected] | 45 |
| 2 | Supply and Installation commissiong 2 | Supply and laying of soft drawn Copper refrigerant pipe of suitable size for 2TR Air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular Thermal Foam insulation including necessary brazing jointing etc as required for cassette Split Air Conditioner as required for item no 1 | 36 | metre | [email protected] | 45 |
| 3 | Supply and Installation commissiong 3 | Supply laying of 4C x 25 Sqmm FRLS PVC insulated 1 1 kV grade PVC sheathed multistrand flexible Copper Cable confirming to IS 7098 Pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units | 38 | nos | [email protected] | 45 |
| 4 | Supply and Installation commissiong 4 | Supply and fixing of 25 mm dia minimum thickness of 1 2mm PVC drain pipe along with accessories and necessary clamps with an U trap at the end as required | 41 | pairs | [email protected] | 45 |
| 5 | Supply and Installation commissiong 5 | Supply and fixing of 75mm Dia minimum 18mm thickness PVC covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. | 34 | pairs | [email protected] | 45 |
| 6 | Supply and Installation commissiong 6 | Supply and installation of Floor mounted powder coated MS 25 x 25x5mm L angle frame including clamps bolts nuts vibrating Dampers as required | 2 | nos | [email protected] | 45 |
| 7 | Supply and Installation commissiong 7 | Drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying | 2 | nos | [email protected] | 45 |
| 8 | Supply and Installation commissiong 8 | Dismantling shifting of old 2TR Cassette split Air Conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including Pump down of refrigerant. | 1 | pairs | [email protected] | 45 |
| 9 | Supply and Installation commissiong 9 | Making of necessary alteration of existing Gypsum False ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling | 1 | pairs | [email protected] | 45 |
| 10 | Supply and Installation commissiong 10 | Supply Installation testing and commissioning of 2TR 24000 BTU per Hour and ISEER value five star rated and compliance with IS 1391 Part 2 2018 wall mounted inverter type Hi wall split cooling inverter air conditioner having wireless remote controller with LED display hermetically sealed scroll rotary compressor and Eco friendly refrigerant initial charge of refrigerant Condensor and Evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230V single phase 50Hz AC power supply The indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor Laying and interconnection of standard length copper refrigerant piping as supplied by the OEM between indoor and outdoor units complete in all respects as required Necessary drilling of hole and finishing the same to match for the surrounding as required. | 3 | set | [email protected] | 45 |
| 11 | Supply and Installation commissiong 11 | Supply and laying of beyond the standard length supplied by the OEM Copper refrigerant pipe of size suitable for 2TR Air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular Thermal Foam insulation for Hi wall Split Air Conditioner as required for item no 1 | 30 | metre | [email protected] | 45 |
| 12 | Supply and Installation commissiong 12 | Supply laying of 4C x 25 Sqmm FRLS PVC insulated 1 1 kV grade PVC sheathed multistrand flexible Copper Cable confirming to IS 7098 Pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units | 30 | metre | [email protected] | 45 |
| 13 | Supply and Installation commissiong 13 | Supply and fixing of 75mm Dia minimum 1.8mm thickness PVC covering pipe using necessary bend collor clamps threded rod supports accessories etc for laying copper refrigernt line and electrical cable as required. | 30 | metre | [email protected] | 45 |
| 14 | Supply and Installation commissiong 14 | Supply and fixing of 25 mm dia minimum thickness of 1 2mm PVC drain pipe along with accessories and necessary clamps with an U trap at the end as required. | 45 | metre | [email protected] | 45 |
| 15 | Supply and Installation commissiong 15 | Supply and installation of Floor mounted powder coated MS L angle frame of minimum thickness 6mm including clamps bolts nuts vibration Dampers as required for mounting of outdoor unit. | 3 | each | [email protected] | 45 |
| 16 | Supply and Installation commissiong 16 | Drilling of hole using core cutting machine of size up to 100 mm dia in concrete brick wall for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required. | 3 | each | [email protected] | 45 |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Choose from flexible plans to access tender documents instantly
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS