SITC of 1.45-1.5 TR 5 Star Inverter AC,Supply of 1.45-1.5 TR 5 Star Inverter AC,SITC of 1.8-2.0 TR
N/a
BHAVNAGAR, GUJARAT
Bid Publish Date
28-Apr-2025, 1:59 pm
Bid End Date
19-May-2025, 1:00 pm
EMD
₹2,58,283
Location
Progress
Quantity
1410
Bid Type
Two Packet Bid
Bharat Sanchar Nigam Limited Portal(bsnl) invites bids for Supply of 7TR HPAC units, ITC package AC unit and condensers, Providing and fixing 40mm dia CPVS Pipe, SITC of 15. 86 mm dia OD refrigerant pipe, SITC of 22. 2 mm dia OD refrigerant pipe, SITC of GI 150x50 mm depth X 1. 6 mm thickness, SITC of GI 300x50 mm depth X 1. 6 mm thickness, Supplying and laying of 1. 1 KV Grade XLPE copper conductor, CM of 7TR HPAC PKG Units for a period of One Year in LUCKNOW, UTTAR PRADESH. Quantity: 1410. Submission Deadline: 19-05-2025 13: 00: 00. Submit your proposal before the deadline.
Main Document
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
BHAVNAGAR, GUJARAT
Indian Oil Corporation Limited
Bharat Sanchar Nigam Limited Portal(bsnl)
KHORDHA, ODISHA
Bharat Sanchar Nigam Limited Portal(bsnl)
KAMRUP, ASSAM
Bharat Sanchar Nigam Limited Portal(bsnl)
CUTTACK, ODISHA
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Supply of 7TR HPAC units | Sub Head I Supply of Precision PAC units, Supply of microprocessor based air cooled type super low noise 7 TR sensible cooling capacity Top or bottom discharge type as per requirement Precision Air conditioning unit working on R407C/R410A refrigerant and capable of delivering minimum 3850 CFM comprising of indoor and outdoor units as detailed below with all components i/c humidifier and heater, controls, provided with BMS connectivity and interlocking, electrical accessories, refrigerant piping within unit, initial charge of refrigrent and oil, Serrated rubber pads, filters having 95 percentage efficiency down to 5 microns including sequential control and Run hour equalization etc, as per detailed specifications attached. Note Rates of refrigerant pipe to be quoted separately in SH III | 15 | nos | consignee_sdeelucknow | 90 |
| 2 | ITC package AC unit and condensers | Sub Head II ITC of Precision PAC units, Installation, testing and commissioning of the above package AC unit and condensers including providing powder coated MS stand for Indoor unit and corrosion treated and painted frame for condensers, minor civil works like cutting / grouting, making good the damages, 25mmX5mm GI earth strip between indoor and outdoor unit, providing necessary scaffolding, pressure testing, vaccumising, gas charging etc. complete as required. | 15 | jobs | consignee_sdeelucknow | 90 |
| 3 | Providing and fixing 40mm dia CPVS Pipe | Sub Head III Miscellaneous items, Providing and fixing 40 mm dia. nominal bore FRLS, HMS High Mechanical Stress, CPVC pipe from outlet socket of HPAC unit complete with CPVC fittings and clamps including cutting and making good the walls etc. complete as required. | 150 | mtr | consignee_sdeelucknow | 90 |
| 4 | SITC of 15.86 mm dia OD refrigerant pipe | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of hard drawn copper refrigerant piping for PAC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class O tubular insulation/with Class O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications complete as required The item shall be measured from outside connection of indoor unit to outside of condensor unit. a. 15.86 mm dia. OD Hard drawn with tube thickness 1.2 mm with 19 mm thick insulation | 210 | mtr | consignee_sdeelucknow | 90 |
| 5 | SITC of 22.2 mm dia OD refrigerant pipe | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of hard drawn copper refrigerant piping for PAC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class O tubular insulation/with Class O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications complete as required The item shall be measured from outside connection of indoor unit to outside of condensor unit. b. 22.2 mm dia. OD Hard drawn with tube thickness 1.2 mm with 19 mm thick insulation | 210 | mtr | consignee_sdeelucknow | 90 |
| 6 | SITC of GI 150x50 mm depth X 1.6 mm thickness | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Galvanisation thickness not less than 50 microns with perforation not more than 17.5 percentage, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts and nuts, etc. as required. a. 150 mm width X 50 mm depth X 1.6 mm thickness | 210 | mtr | consignee_sdeelucknow | 90 |
| 7 | SITC of GI 300x50 mm depth X 1.6 mm thickness | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Galvanisation thickness not less than 50 microns with perforation not more than 17.5 percentage, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts and nuts, etc. as required. b. 300 mm width X 50 mm depth X 1.6 mm thickness | 210 | mtr | consignee_sdeelucknow | 90 |
| 8 | Supplying and laying of 1.1 KV Grade XLPE copper conductor | Supplying and laying of 1.1 KV grade, XLPE insulated, armoured and sheathed copper conductor cables confirming to IS 1554 Part I 1964 of 2 X 2.5 sq. mm size including providing and making cable termination by crimping joints as required, for interconnecting between the outdoor and indoor units as required at site. Suitable clamping arrangement shall be provided for cables to be fixed on walls / Cable trays / racks where necessary. Suitable cable glands shall also be provided for all cable terminations. | 375 | mtr | consignee_sdeelucknow | 90 |
| 9 | CM of 7TR HPAC PKG Units for a period of One Year | Sub Head IV MAINTENANCE ITEMS, Comprehensive maintenance of 7 TR HPAC PKG, units which include routine preventive and breakdown maintenance for a period of one years i/c supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. | 15 | each pkg per year | consignee_sdeelucknow | 365 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Key insights about UTTAR PRADESH tender market
The eligibility requirements include being a registered entity with the necessary licenses, experience in supplying and installing HVAC systems, and having successfully completed similar projects. Bidders should also comply with all technical specifications outlined in the tender instructions.
Bidders need to present various required certificates such as a valid GST registration, company incorporation certificate, and relevant quality compliance certifications for the HVAC equipment. These documents are essential to validate the bidder's capabilities and adherence to industry standards.
To register for the tender, you will need to create an account on the designated electronic procurement platform and submit all necessary documentation in the specified formats. Detailed guidance on the registration process is included in the tender documents.
Accepted document formats for the tender submission include PDF and Word files, among others specified in the tender guidelines. It is crucial to adhere to the submission formats to ensure the proposal is evaluated without issues.
The payment terms involve milestone payments based on the completion of specific project phases, as detailed in the tender documents. Bidders should ensure they understand these terms clearly and incorporate them into their financial planning for project execution.
Sign up now to access all documents
Main Document
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS