| Performance Parameters | Providing Required test load | No(Seller not providing and buyer to arrange same) |
| Performance Parameters | The test load requirements Provided | NA(in case seller not providing) |
| Performance Parameters | Type of Weigh Bridge | Surface Mounted |
| Performance Parameters | Maximum Capacity of weigh Bridge in Tonnes | 20 |
| Performance Parameters | Graduation of weigh bridge in KG | 5 |
| Performance Parameters | Warranty Period in Years | 1 |
| CONSTRUCTION FEATURES | The type of Construction of Weigh Bridge Plat form | Modular enabling easy Assembly ,Transportation and adjustment of Size |
| CONSTRUCTION FEATURES | Length of the Platform required for weighing in meters | 7.5 m |
| CONSTRUCTION FEATURES | Width of the Plat form in meters | 3m |
| CONSTRUCTION FEATURES | Ramp length in mm | NA ( For surface Mounted and Pit mounted) |
| load Cell | Capacity of Load Cell in Tonnes | 10 ton |
| load Cell | No of Load Cell in the weigh bridge system | 4 |
| load Cell | Type of Load Cell | Double ended Shear Beam Load Cell |
| load Cell | Load cell technology | Digital |
| load Cell | Material of Body of Load Cell | Nickel plated Alloy steel |
| load Cell | Protection class for load cell | IP 68 |
| load Cell | Certification required for for load cell | OIML |
| load Cell | Auto rotation lock | NA( For double endede shear beam load cell ) |
| load Cell | LENGTH of cable Provided for load cell in meters | 6 |
| load Cell | shall be provided with automatic diagnostics | Yes |
| load Cell | shall be unaffected by off center loads | Yes |
| load Cell | Rated ouput Repeatability in terms of FS | 0.01% |
| load Cell | Overload rating SAFE | 150% |
| Weigh Bridge Controller | Housing Protection for Digital Controller | IP 65 |
| Weigh Bridge Controller | Details of Printer type | laser printer |
| Weigh Bridge Controller | Printer Make | epson |
| Weigh Bridge Controller | USB port provided | Yes |
| Weigh Bridge Controller | No of digits of led display for weight | 6 |
| Weigh Bridge Controller | Minimum character size of LCD Display | 16x2 |
| Weigh Bridge Controller | Provision for remote Display port | Yes |
| Weigh Bridge Controller | Protection class for junction box for connection | IP 67 |
| Weigh Bridge Controller | Surge protection for junction box | Yes |
| Weigh Bridge Controller | Material of construction for junction box | ABS |
| Weigh Bridge Controller | Back up time in hours | 6 |
| Additional parameters | Number of additional load cell to be supplied | Not supplied |
| Additional parameters | UPS to be provided with the system | Yes |