Supply of 420kV, 3150A, 63kA SF6 Circuit Breakers(3-Ph),Supply of Mandatory Spares for above suppli
Power Grid Corporation Of India Limited
MAYURBHANJ, ODISHA
Bid Publish Date
02-Jul-2026, 9:48 am
Bid End Date
23-Jul-2026, 11:00 am
Progress
Quantity
103
Category
420 kV Circuit Breaker
Bid Type
Two Packet Bid
A tender has been published for Power Grid Corporation Of India Limited 420 kV Circuit Breaker, 420kV CSD Supply, 420 kV CB Spares, 420 KV CIRCUIT BREAKER- RETROFITTING, 420kV CSD Installation and Commissioning. Quantity: 103 by. Submission Deadline: 23-07-2026 11: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
420 kV Circuit Breaker , 420kV CSD Supply , 420 kV CB Spares , 420 KV CIRCUIT BREAKER- RETROFITTING , 420kV CSD Installation and Commissioning
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
35
Payment Timelines
Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Pre-Bid Date
09-07-2026 15:00:00
Pre-Bid Venue
Online mode
Max Delivery Days
638
Delivery Locations
1
Delivery Cities
Sonitpur
Delivery Pincodes
784103
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Dhruba Narayan Sarmah | 784103,Power Grid Corporation Of India Limited,APCOMP. SCHEME, 400/220/132 KV BALIPARA SUBSTATION, POWERGRID, PO/PS: CHARDUAR, DIST:SONITPUR, ASSAM-784103 | Sonitpur | Assam | 784103 | 5 | 638 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
BOQ
BOQ
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Power Grid Corporation Of India Limited
MAYURBHANJ, ODISHA
Nuclear Power Corporation Of India Limited
UTTARA KANNADA, KARNATAKA
Power Grid Corporation Of India Limited
Nuclear Power Corporation Of India Limited
CHITTORGARH, RAJASTHAN
Indian Army
AGRA, UTTAR PRADESH
Tender Results
Loading results...
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420kV CSD Supply
Controlled switching device for 420 kV, 3 phase circuit breaker
420kV CSD Supply
Controlled switching device for 420 kV, 3 phase circuit breaker
420kV CSD Supply
Controlled switching device for 420 kV, 3 phase circuit breaker
420 kV CB Spares
Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW
420 kV CB Spares
Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW
420 kV CB Spares
Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420kV CSD Installation and Commissioning
Service Charge for Retrofitment of the supplied CSD
420kV CSD Installation and Commissioning
Service Charge for Retrofitment of the supplied CSD
420kV CSD Installation and Commissioning
Service Charge for Retrofitment of the supplied CSD
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV CB Spares
Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW
420 kV CB Spares
Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW
420 kV CB Spares
Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW
420 kV CB Spares
Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV Circuit Breaker
Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW
420 kV CB Spares
Supply of mandatory spares for 420KV CB without PIR as per the Annexure-I attached at SoW
420 kV CB Spares
Supply of mandatory spares for 420KV CB without PIR as per the Annexure-I attached at SoW
420 kV CB Spares
Supply of mandatory spares for 420KV CB without PIR as per the Annexure-I attached at SoW
420 kV CB Spares
Supply of mandatory spares for 420KV CB without PIR as per the Annexure-I attached at SoW
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
420 KV CIRCUIT BREAKER- RETROFITTING
Retrofitment of supplied CB as per TS and SoW complete in all respect
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 5 | set | buyerbalipara2 | 638 | |
| 2 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 2 | set | buyerbalipara2 | 638 | |
| 3 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 1 | set | consigneebongaigaon4 | 638 | |
| 4 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 6 | set | buyermisa6 | 638 | |
| 5 | 420kV CSD Supply | Controlled switching device for 420 kV, 3 phase circuit breaker | 1 | set | buyerbalipara2 | 638 | |
| 6 | 420kV CSD Supply | Controlled switching device for 420 kV, 3 phase circuit breaker | 1 | set | consigneebongaigaon4 | 638 | |
| 7 | 420kV CSD Supply | Controlled switching device for 420 kV, 3 phase circuit breaker | 2 | set | buyermisa6 | 638 | |
| 8 | 420 kV CB Spares | Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW | 1 | set | buyerbalipara2 | 638 | |
| 9 | 420 kV CB Spares | Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW | 1 | set | consigneebongaigaon4 | 638 | |
| 10 | 420 kV CB Spares | Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW | 1 | set | buyermisa6 | 638 | |
| 11 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 5 | set | buyerbalipara2 | 638 | |
| 12 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 2 | set | buyerbalipara2 | 638 | |
| 13 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 1 | set | consigneebongaigaon4 | 638 | |
| 14 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 6 | set | buyermisa6 | 638 | |
| 15 | 420kV CSD Installation and Commissioning | Service Charge for Retrofitment of the supplied CSD | 1 | set | buyerbalipara2 | 638 | |
| 16 | 420kV CSD Installation and Commissioning | Service Charge for Retrofitment of the supplied CSD | 1 | set | consigneebongaigaon4 | 638 | |
| 17 | 420kV CSD Installation and Commissioning | Service Charge for Retrofitment of the supplied CSD | 2 | set | buyermisa6 | 638 | |
| 18 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 2 | set | consigneenellore2 | 638 | |
| 19 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 2 | set | consigneevizag1 | 638 | |
| 20 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 3 | set | consigneeramagundam1 | 638 | |
| 21 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 1 | set | consigneeguntur1 | 638 | |
| 22 | 420 kV CB Spares | Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW | 1 | set | consigneenellore2 | 638 | |
| 23 | 420 kV CB Spares | Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW | 1 | set | consigneevizag1 | 638 | |
| 24 | 420 kV CB Spares | Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW | 1 | set | consigneeramagundam1 | 638 | |
| 25 | 420 kV CB Spares | Supply of Complete Pole (Phase) of 420kV, 3150A, 63kA Circuit Breaker without Closing Resistor including grading capacitor (if applicable),and with Pole Column, Interrupter, Operating Mechanism, Marshling Box and Terminal Connector but without Support Structure as per TS and SoW | 1 | set | consigneeguntur1 | 638 | |
| 26 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 2 | set | consigneenellore2 | 638 | |
| 27 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 2 | set | consigneevizag1 | 638 | |
| 28 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 3 | set | consigneeramagundam1 | 638 | |
| 29 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 1 | set | consigneeguntur1 | 638 | |
| 30 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 1 | set | consigneesriperumbudur1 | 638 | |
| 31 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 6 | set | buyerhosur5 | 638 | |
| 32 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 2 | set | buyerbangalore13 | 638 | |
| 33 | 420 kV Circuit Breaker | Supply of 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without Closing Resistor and with Support Structure, Marshalling Box and Terminal Connector as per TS and SoW | 11 | set | buyerkolar2 | 638 | |
| 34 | 420 kV CB Spares | Supply of mandatory spares for 420KV CB without PIR as per the Annexure-I attached at SoW | 1 | set | consigneesriperumbudur1 | 638 | |
| 35 | 420 kV CB Spares | Supply of mandatory spares for 420KV CB without PIR as per the Annexure-I attached at SoW | 1 | set | buyerhosur5 | 638 | |
| 36 | 420 kV CB Spares | Supply of mandatory spares for 420KV CB without PIR as per the Annexure-I attached at SoW | 1 | set | buyerbangalore13 | 638 | |
| 37 | 420 kV CB Spares | Supply of mandatory spares for 420KV CB without PIR as per the Annexure-I attached at SoW | 1 | set | buyerkolar2 | 638 | |
| 38 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 1 | set | consigneesriperumbudur1 | 638 | |
| 39 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 6 | set | buyerhosur5 | 638 | |
| 40 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 2 | set | buyerbangalore13 | 638 | |
| 41 | 420 KV CIRCUIT BREAKER- RETROFITTING | Retrofitment of supplied CB as per TS and SoW complete in all respect | 11 | set | buyerkolar2 | 638 |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Power Grid Corporation Of India Limited
Uttar Pradesh Power Corporation Limited (uppcl)
📍 MATHURA, UTTAR PRADESH
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited (uprvunl) Lucknow
📍 ETAH, UTTAR PRADESH
N/a
📍 CHAMPAWAT, UTTARAKHAND
📍 COIMBATORE, TAMIL NADU
Sign up now to access all documents
Main Document
OTHER
BOQ
BOQ
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS