Progress
RAIndian Army invites bids for Detectors complying with and type certified to EN 45 addressable type multisensory detector with heat and smoke combination with self built intelligence as per IS 11360, Remote response indicator and provision for cable or wire entry from top, Manual call box ass up control module made from 18 SWG CRCA sheet having single LED indicator and release type push bottom with incase of fire break glass printed on front cover as per ATC, Fire alarm sounders or sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65db to 12db measured at 1 point 5M with sound as per ATC, Fire alarm control panel 4 zone as per IS15908 2011 standard certified IEC 623681 2018 upto 600 cable connectivity per zone 20 Detectors per zone plus 5 MCPs LCD Display standby as per ATC, Fire Alarm control panel 2 zone as per IS15908 2011 standard certified for safety standard IEC 62368 1 2018 upto 600 cable connectivity per zone 20 detectors per zone plus 5 MCP as per ATC, Polyvinyl Chloride FRSL cable 2 core 1 point 5 sqmm, Mild Steel ERW conduit 20mm bore dia, Bat tery 7AH 12 Volt in BARMER, RAJASTHAN. Quantity: 1015. Submission Deadline: 12-10-2026 13: 00: 00. Submit your proposal before the deadline.
Start
16-Oct-2026, 3:00 pm
End
17-Oct-2026, 3:00 pm
Duration: 24 hours
Reverse Auction Document
🔴 RA is live! Log in to the portal to participate.
Quantity
1015
Category
Manual call box ass up control module made from 18 SWG CRCA sheet having single LED indicator and release type push bottom with incase of fire break glass printed on front cover as per ATC
Bid Type
Two Packet Bid
Bid Validity
60 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
Bid Splitting Applied
No
Min. Avg. Annual Turnover
4
OEM Avg. Turnover
4
Past Performance
80 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Detectors complying with and type certified to EN 45 addressable type multisensory detector with heat and smoke combination with self built intelligence as per IS 11360 , Remote response indicator and provision for cable or wire entry from top , Manual call box ass up control module made from 18 SWG CRCA sheet having single LED indicator and release type push bottom with incase of fire break glass printed on front cover as per ATC , Fire alarm sounders or sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65db to 12db measured at 1 point 5M with sound as per ATC , Fire alarm control panel 4 zone as per IS15908 2011 standard certified IEC 623681 2018 upto 600 cable connectivity per zone 20 Detectors per zone plus 5 MCPs LCD Display standby as per ATC , Fire Alarm control panel 2 zone as per IS15908 2011 standard certified for safety standard IEC 62368 1 2018 upto 600 cable connectivity per zone 20 detectors per zone plus 5 MCP as per ATC , Polyvinyl Chloride FRSL cable 2 core 1 point 5 sqmm , Mild Steel ERW conduit 20mm bore dia , Bat tery 7AH 12 Volt
Advisory Bank
State Bank of India
ePBG Percentage
3%
ePBG Duration (Months)
14
Max Delivery Days
60
Delivery Locations
1
Delivery Cities
Barmer
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| - | Barmer | Barmer | - | - | 50 | 60 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Detectors complying with and type certified to EN 45 addressable type multisensory detector with heat and smoke combination with self built intelligence as per IS 11360
Detectors complying with and type certified to EN 45 addressable type multisensory detector with heat and smoke combination with self built intelligence as per IS 11360
Remote response indicator and provision for cable or wire entry from top
Remote response indicator and provision for cable or wire entry from top
Manual call box ass up control module made from 18 SWG CRCA sheet having single LED indicator and release type push bottom with incase of fire break glass printed on front cover as per ATC
Manual call box ass up control module made from 18 SWG CRCA sheet having single LED indicator and release type push bottom with incase of fire break glass printed on front cover as per ATC
Fire alarm sounders or sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65db to 12db measured at 1 point 5M with sound as per ATC
Fire alarm sounders or sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65db to 12db measured at 1 point 5M with sound as per ATC
Fire alarm control panel 4 zone as per IS15908 2011 standard certified IEC 623681 2018 upto 600 cable connectivity per zone 20 Detectors per zone plus 5 MCPs LCD Display standby as per ATC
Fire alarm control panel 4 zone as per IS15908 2011 standard certified IEC 623681 2018 upto 600 cable connectivity per zone 20 Detectors per zone plus 5 MCPs LCD Display standby as per ATC
Fire Alarm control panel 2 zone as per IS15908 2011 standard certified for safety standard IEC 62368 1 2018 upto 600 cable connectivity per zone 20 detectors per zone plus 5 MCP as per ATC
Fire Alarm control panel 2 zone as per IS15908 2011 standard certified for safety standard IEC 62368 1 2018 upto 600 cable connectivity per zone 20 detectors per zone plus 5 MCP as per ATC
Polyvinyl Chloride FRSL cable 2 core 1 point 5 sqmm
Polyvinyl Chloride FRSL cable 2 core 1 point 5 sqmm
Mild Steel ERW conduit 20mm bore dia
Mild Steel ERW conduit 20mm bore dia
Bat tery 7AH 12 Volt
Bat tery 7AH 12 Volt
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Detectors complying with and type certified to EN 45 addressable type multisensory detector with heat and smoke combination with self built intelligence as per IS 11360 | Detectors complying with and type certified to EN 45 addressable type multisensory detector with heat and smoke combination with self built intelligence as per IS 11360 | 50 | each | offgbsoutarlai | 60 | |
| 2 | Remote response indicator and provision for cable or wire entry from top | Remote response indicator and provision for cable or wire entry from top | 10 | each | offgbsoutarlai | 60 | |
| 3 | Manual call box ass up control module made from 18 SWG CRCA sheet having single LED indicator and release type push bottom with incase of fire break glass printed on front cover as per ATC | Manual call box ass up control module made from 18 SWG CRCA sheet having single LED indicator and release type push bottom with incase of fire break glass printed on front cover as per ATC | 15 | each | offgbsoutarlai | 60 | |
| 4 | Fire alarm sounders or sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65db to 12db measured at 1 point 5M with sound as per ATC | Fire alarm sounders or sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65db to 12db measured at 1 point 5M with sound as per ATC | 11 | each | offgbsoutarlai | 60 | |
| 5 | Fire alarm control panel 4 zone as per IS15908 2011 standard certified IEC 623681 2018 upto 600 cable connectivity per zone 20 Detectors per zone plus 5 MCPs LCD Display standby as per ATC | Fire alarm control panel 4 zone as per IS15908 2011 standard certified IEC 623681 2018 upto 600 cable connectivity per zone 20 Detectors per zone plus 5 MCPs LCD Display standby as per ATC | 5 | each | offgbsoutarlai | 60 | |
| 6 | Fire Alarm control panel 2 zone as per IS15908 2011 standard certified for safety standard IEC 62368 1 2018 upto 600 cable connectivity per zone 20 detectors per zone plus 5 MCP as per ATC | Fire Alarm control panel 2 zone as per IS15908 2011 standard certified for safety standard IEC 62368 1 2018 upto 600 cable connectivity per zone 20 detectors per zone plus 5 MCP as per ATC | 4 | each | offgbsoutarlai | 60 | |
| 7 | Polyvinyl Chloride FRSL cable 2 core 1 point 5 sqmm | Polyvinyl Chloride FRSL cable 2 core 1 point 5 sqmm | 450 | rm | offgbsoutarlai | 60 | |
| 8 | Mild Steel ERW conduit 20mm bore dia | Mild Steel ERW conduit 20mm bore dia | 450 | rm | offgbsoutarlai | 60 | |
| 9 | Bat tery 7AH 12 Volt | Bat tery 7AH 12 Volt | 20 | each | offgbsoutarlai | 60 |
Extended Deadline
12-Oct-2026, 7:30 am
Opening Date
13-Oct-2026, 7:30 am
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer