TenderDekho Logo
Closed GEM

Procurement Opportunity: SPECTROPHOTOMETER

Bid Publish Date

25-Aug-2026, 5:45 pm

Bid End Date

04-Sep-2026, 6:00 pm

Progress

Issue25-Aug-2026, 5:45 pm
AwardPending

A tender has been published for Indian Institute Of Technology (iit) SPECTROPHOTOMETER (Q2) ( PAC Only). Quantity: 1 by. Submission Deadline: 04-09-2026 18: 00: 00. Check eligibility and apply.

Authority & Contact

Tender Data

Bid Details

Quantity

1

Bid Type

Two Packet Bid

Bid Validity

90 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

No

MII Purchase Preference

Yes

MII Preference Band

L1+20%

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

Yes

Startup Exemption/Relaxation

Yes

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

575

OEM Avg. Turnover

46

Past Performance

80 %

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

SPECTROPHOTOMETER (Q2) ( PAC Only )

Delivery Details

Max Delivery Days

28

Delivery Locations

1

Delivery Cities

Kanpur Nagar

Delivery Pincodes

208016

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Santosh Kumar Yadav208016,Central Store & Purchase Section, IIT Kanpur, GT Road, Kalyanpur 208016 (UP)Kanpur NagarUttar Pradesh208016128-

Authority Records

MINISTRY OF EDUCATIONHIGHER EDUCATION DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9806055.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Categories 18

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
LIGHT SOURCE Light Source Halogen Lamp, Deuterium Lamp, LED, Tungsten Halogen Lamp, Xenon Flash
LIGHT SOURCE Diffraction Grating (lines/mm) 600, 800, 1000, 1200, 1400, 1600, 1800
LIGHT SOURCE Switching of Light Source Automatic, Mannual, NA
LIGHT SOURCE Wavelength Setting And Scanning Automatic, Mannual
TYPE Type of Spectrophotometer UV - VISIBLE, VISIBLE, UV - VISIBLE - IR, NIR, UV-VIS, UV-Visible spectrophotometer, double beam/split beam, microprocessor controlled with dual source assembly
TYPE Type of Optical System Single Beam, Split Beam, Double Beam
TYPE Monochromator Type Reflexive Grating, Holographic Grating, Czerny-turner, NA, Scanning grating
TYPE Detector Type Photo Multiplier Tube (PMT), Photodiode, CMOS, Diode array, Silicon, Silicon & Lead Sulfide, Indium Gallium Arsenide (InGaAs)
TYPE Spectral Bandwidth Type Fixed Bandwidth, Variable Bandwidth
OPTICAL PERFORMANCE Source Wavelength - Minimum 175, 180, 185, 190, 195, 200, 320, 340, 400, 570, 850, 950, 460
OPTICAL PERFORMANCE Source Wavelength - Maximum 320, 340, 760, 780, 900, 960, 1000, 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650, 644 Or higher
OPTICAL PERFORMANCE Resolution 0.002, 0.3, 0.5, 1, 1.25, 1.5, 1.7, 2, 0.2, 0.01
OPTICAL PERFORMANCE Wavelength Accuracy (+/-) 0.1, 0.3, 0.5, 0.8, 1, 1.5, 2, 2.5, 0.05
OPTICAL PERFORMANCE Bandwidth (nm) 0.1, 0.2, 0.5, 1, 1.5, 1.8, 2.0, 4.0, 5.0, 0.1 to 5.0, 7, 8.5
OPTICAL PERFORMANCE Focal length (mm) 0 to 49, 50 to 99, 100 to 149, 150 to 199, 200 to 249, 250 to 299, 300 and above
OPTICAL PERFORMANCE Photometric measurement modes Transmittance, Absorbance, Concentration (Wavelength, time), Reflectance, Energy, Polarisation
OPTICAL PERFORMANCE Photometric Absorbance (Max) (Abs) (+/-) 0.2 - 8
OPTICAL PERFORMANCE Photometric Absorbance Accuracy (Max) (+/-) 0.001 - 0.5
OPTICAL PERFORMANCE Photometric Transmittance (Max) (+/-) 0 - 100
OPTICAL PERFORMANCE Photometric Transmittance Accuracy (Max) (+/-) 0 - 0.5
OPTICAL PERFORMANCE Photometric Reflectance (Max) (+/-) 0 - 100
GENERIC Display In-built display, Through PC
GENERIC Display type LCD with Backlight, LED, LCD touchscreen, TFT, NA
GENERIC Display Size 0 - 30
GENERIC Test result printing Through inbuilt Printer, Through external printer
GENERIC If inbuilt printer, Type of printer Thermal printer, Dot matrix, Laser b/w, Inkjet b/w, Color laser, Color inkjet, N/A
GENERIC Internal storage(GB) 0 - 80
GENERIC Mximum Path Length of sample 0 - 120
GENERIC Number of Cuvettes supplied-inclusive in the scope of supply 10, 25, 50, 100, 200, 300, 400, 500, 2, 4, 6, 8, 0
GENERIC Spares and Consumables inclusive in the scope of supply Yes, No
OPERATING CONDITIONS Minimum Operating Temperature -5, -10, 0, 5, 10
OPERATING CONDITIONS Maximum Operating Temperature 35, 40, 45, 50, 55, 60
OPERATING CONDITIONS Operating Humidity (RH) (%) at 40 degree C 80, 85, 90, 95
WARRANTY Onsite Warranty 1, 2, 3, 4, 5
WARRANTY Availability of Spares (at extra cost) 2, 3, 4, 5, 6, 7, 8, 10
Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements Yes, No
Certification Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use Yes, No
Certification Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification Yes, No