Centrifuge machine RPM 10000 with accuracy plus and minus 5 percent
Bid Type
Two Packet Bid
A tender has been published for N/a Centrifuge machine RPM 10000 with accuracy plus and minus 5 percent, Title2, Title3, Title4, Title5 in JAIPUR, RAJASTHAN. Quantity: 5 by. Submission Deadline: 03-10-2025 17: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Centrifuge machine RPM 10000 with accuracy plus and minus 5 percent , Title2 , Title3 , Title4 , Title5
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
Centrifuge machine RPM 10000 with accuracy plus and minus 5 percent
Centrifuge Design-Bench top RPM-10000 with load or better RPM setting Accuracy plus and minus 5 percent Ambient operating temperature range in Degree Centigrade Celsius and humidity range 0 to 50 Degree Centigrade Relative Humidity 15 to 90percent, Number of acceleration and de-acceleration profile in built for rotor speed while automatic breaking Programmable from 50 to 200 seconds in interval of 5 seconds, Maximum timer set point-60 minutes, Display type- LCD Speed controller- Microprocessor controlled preprogrammed speed controller which can control RPM as well as RCF Rotor feature with reference to Autoclavability- Autoclave Rotor at the rate 121 Degree Centigrade Power supply-230 volts 50Hz AC plus and minus 10 percent ,Rotor head- Rotor head with holding capacity 2 mL 10-15mL and 50 mL centrifuge tubes Rotor imbalance diagnostics and automative stop if required- Yes Size of Rotor supplied with centrifuge-60x50mL (for angle rotor) RPM 10000 or better Accessories- Spanner to tight or loose nut of rotor on motor shaft head puller spare rotor nuts fuse-2instruction manual book Installation CD Auto cut off- Yes Timer provided-Yes.
Title2
Description1
Title3
Description1
Title4
Description1
Title5
Description1
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Centrifuge machine RPM 10000 with accuracy plus and minus 5 percent | Centrifuge Design-Bench top RPM-10000 with load or better RPM setting Accuracy plus and minus 5 percent Ambient operating temperature range in Degree Centigrade Celsius and humidity range 0 to 50 Degree Centigrade Relative Humidity 15 to 90percent, Number of acceleration and de-acceleration profile in built for rotor speed while automatic breaking Programmable from 50 to 200 seconds in interval of 5 seconds, Maximum timer set point-60 minutes, Display type- LCD Speed controller- Microprocessor controlled preprogrammed speed controller which can control RPM as well as RCF Rotor feature with reference to Autoclavability- Autoclave Rotor at the rate 121 Degree Centigrade Power supply-230 volts 50Hz AC plus and minus 10 percent ,Rotor head- Rotor head with holding capacity 2 mL 10-15mL and 50 mL centrifuge tubes Rotor imbalance diagnostics and automative stop if required- Yes Size of Rotor supplied with centrifuge-60x50mL (for angle rotor) RPM 10000 or better Accessories- Spanner to tight or loose nut of rotor on motor shaft head puller spare rotor nuts fuse-2instruction manual book Installation CD Auto cut off- Yes Timer provided-Yes. | 1 | pieces | [email protected] | 15 | |
| 2 | Title2 | Description1 | 1 | pieces | [email protected] | 15 | |
| 3 | Title3 | Description1 | 1 | pieces | [email protected] | 15 | |
| 4 | Title4 | Description1 | 1 | pieces | [email protected] | 15 | |
| 5 | Title5 | Description1 | 1 | pieces | [email protected] | 15 |
Discover companies most likely to bid on this tender
Experience Criteria
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS