Item-1,Item-2,Item-3,Item-4,Item-5,Item-6,Item-7,Item-8,Item-9,Item-10,Item-11,Item-12,Item-13,Item
Oil And Natural Gas Corporation Limited
Bid Publish Date
30-Jan-2025, 12:12 pm
Bid End Date
16-Oct-2025, 10:00 am
EMD
₹18,644
Location
Progress
Quantity
575
Category
item-1
Bid Type
Two Packet Bid
Nuclear Power Corporation Of India Limited has released a public tender for item-1, item-2, item-3, item-4, item-5, item-6, item-7, item-8, item-9, item-10, item-11, item-12, item-13, item- 14, item-15, item-16, item-17, item-18, item-19, item-20, item-21, item-22, item-23, item-24, item-25, item-26, item-27, item-28, item-29, item-30, item-31, item-32, item-33, item-34, item-35, item-36, item-37, item-38, item-39, item-40, item-41, item-42, item-43, item-44, item-45, item-46, item-47, item-48, item-49, item-50, item-51, item-52, item-53, item-54, item-55, item-56, item-57, item-58, item-59, item-60, item-61, item-62, item-63, item-64, item-65, item-66, item-67, item-68, item-69, item-70, item-71, item-72, item-73, item-74, item-75, item-76, item-77, item-78, item-79, item-80, item-81, item-82, item-83, item-84, item-85, item-86, item-87, item-88, item-89, item-90, item-91, item-92, item-93, item-94, item-95, item-96, item-97 in CHITTORGARH, RAJASTHAN. Quantity: 575. Submission Deadline: 16-10-2025 10: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
item-1 , item-2 , item-3 , item-4 , item-5 , item-6 , item-7 , item-8 , item-9 , item-10 , item-11 , item-12 , item-13 , item- 14 , item-15 , item-16 , item-17 , item-18 , item-19 , item-20 , item-21 , item-22 , item-23 , item-24 , item-25 , item-26 , item-27 , item-28 , item-29 , item-30 , item-31 , item-32 , item-33 , item-34 , item-35 , item-36 , item-37 , item-38 , item-39 , item-40 , item-41 , item-42 , item-43 , item-44 , item-45 , item-46 , item-47 , item-48 , item-49 , item-50 , item-51 , item-52 , item-53 , item-54 , item-55 , item-56 , item-57 , item-58 , item-59 , item-60 , item-61 , item-62 , item-63 , item-64 , item-65 , item-66 , item-67 , item-68 , item-69 , item-70 , item-71 , item-72 , item-73 , item-74 , item-75 , item-76 , item-77 , item-78 , item-79 , item-80 , item-81 , item-82 , item-83 , item-84 , item-85 , item-86 , item-87 , item-88 , item-89 , item-90 , item-91 , item-92 , item-93 , item-94 , item-95 , item-96 , item-97
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
OTHER
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Oil And Natural Gas Corporation Limited
Nuclear Power Corporation Of India Limited
CHITTORGARH, RAJASTHAN
Nuclear Power Corporation Of India Limited
CHITTORGARH, RAJASTHAN
Nuclear Power Corporation Of India Limited
CHITTORGARH, RAJASTHAN
N/a
CENTRAL DELHI, DELHI
Tender Results
Loading results...
item-1
Resistance Temperature Transmitter ( Resistance to Current Converter), Make -Elektra Precision .Input- RTD Pt-200. Temperature range 0-100 degree centigrade, Output- 04 to 20 mA DC (Two no of output) Zero & span adjustable. Power supply- 118 VAC with connector. other detail as Annexure-1.(Bidder should comply one to one in specification as attached)
item-2
Spare Elektra ( earlier Lektrolab ) make Resistance Temperature Transmitter. Input RTD Pt.200. Temp Range- 230 - 320 Degree Centigrade. O/P- 04 to 20 mA DC. Single output. Other common details as per attached annexure-1.
item-3
Spare Elektra ( earlier Lektrolab ) make Resistance Temperature Transmitter. Input RTD-Pt.200. Temp Range- 0-320 Degree Centigrade. Output- 04 to 20 mA DC with Double isolated outputs. Other common details as per attached annexure-1.
item-4
Resistance Temperature Transmitter ( Resistance to Current Converter), Make-Elektra Precision .Input- RTD Pt-100. Temperature range 0-100 degree centigrade, Output- 04 to 20 mA DC (Two no of output) Zero & span adjustable. Power supply- 118 VAC with connector. other detail as Annexure-2.(Bidder should comply one to one in specification as attached)
item-5
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-Flow indicating alarm meter,Range-0-400 ft/sec,Alarm -High ,Alarm relay-One for High alarm, Input -4-20mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-6
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-Temperature indicating alarm meter,Range-0-100 Degree C,Alarm -High ,Alarm relay-One for High alarm, Input -4-20mA,Mounting arrangement-1a,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-7
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Differential Pressure Indicating Alarm,Range- -15 to +25 gm/cm2,Alarm -High ,Alarm relay-One for High alarm, Input -4-20mA,Mounting arrangement-1a,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-8
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating Alarm,Range- 0-700 (Squre root scale flow) lpm, Alarm -Low ,Alarm relay-One for Low alarm, Input -10-50mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-9
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Temperature Indicating Alarm,Range- 0 to 70 degree C,Alarm -Low/High ,Alarm relay-One for High alarm and One for Low Alarm, Input -4-20mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-10
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating meter ,Range- 0-6 (Squre root scale) klpm,Alarm -No Alarm ,Alarm relay-No Alarm, Input -10-50 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-11
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Level Indicating meter ,Range- 0-10 Meter ,Alarm -No Alarm ,Alarm relay-No Alarm, Input -4-20 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-12
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating meter ,Range- 0-10.7 meter / sec & 0-30 Feet /sec ,Alarm -High ,Alarm relay-One for High alarm, Input -4-20 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-13
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating meter ,Range- 0-10.7 meter / sec & 0-30 Feet /sec ,Alarm -High ,Alarm relay-One for High alarm, Input -0-4 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-14
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating alarm meter ,Range- 0-0.7 Kg/cm2 ,Alarm -High/Low ,Alarm relay-One for High alarm & One for Low alarm, Input -4-20 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-15
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating alarm meter ,Range- 0-1.5 x 106 kg/hr ,Alarm -High ,Alarm relay-One for High alarm , Input -4-20 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-16
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Meter, Range- 0-5 kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20 mA, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-17
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Meter, Range- 35-85 Psig, Alarm -NA, Alarm relay- NA, Input -10-50 mA, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-18
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Volt Meter Indicating alarm, Range- 0-300 Volt, Alarm- Low, Alarm relay- One for Low alarm, Input -0-300 v dc, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-19
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Volt Meter Indicating alarm, Range- 0-75 Volt, Alarm- Low, Alarm relay- One for Low alarm, Input -0-75 v dc, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-20
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Volt Meter Indicating alarm, Range- 0-5 mA, Alarm- High, Alarm relay- One for High alarm, Input -0-5 ma, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-21
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Volt Meter Indicating alarm, Range- 0-750 mA, Alarm- High, Alarm relay- One for High alarm, Input -0-750 microA, Mounting arrangement-4b,Normal operating 118 V AC, 50
item-22
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating alarm meter, Range- 0-100 Psig, Alarm -High, Alarm relay- One for High alarm, Input -10-50 mA, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-23
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Light Indicating alarm meter, Range- 160-220 cm, Alarm -Low, Alarm relay- One for Low alarm, Input -10-50 mA, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-24
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-4.22 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-25
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Indicating Alarm meter, Range- 50-100 Percent, Alarm- Low, Alarm relay- One for Low alarm, Input -0-1 ma, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-26
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm Meter, Range- 0-60 Psig, Alarm -Low, Alarm relay- One for Low alarm, Input -4-20 ma, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-27
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm Meter, Range- 0-70 Kg/cm2, Alarm -Low, Alarm relay- One for Low alarm, Input -4-20 ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-28
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm Meter, Range- 0-7 Kg/cm2, Alarm -Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20 ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-29
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Light Indicating Meter, Range- 0-60 cm, Alarm -NA, Alarm relay- NA, Input -4-20 ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-30
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Light Indicating Meter, Range- 25-82 cm, Alarm -NA, Alarm relay- NA, Input -4-20 ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-31
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-15 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-32
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Light Indicating Meter, Range- 0-280 cm, Alarm -Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -10-50 mA, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-33
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- -2 to +3 Psig, Alarm -High/Low, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-34
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-5 Kg/cm2, Alarm -Low, Alarm relay- One for Low Alarm, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-35
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-750 Psig, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-36
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- -14.05 to +14.05 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-37
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-52.7 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-38
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-4.22 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-39
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-2.1 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-2b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-40
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-120 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent
item-41
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Temperature Indicating Alarm meter, Range- 0-320Deg.C, Alarm -Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-42
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating Alarm meter, Range- 0-2000 LPM, Alarm -Low, Alarm relay- One for Low Alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-43
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-14 KG/CM2, Alarm- High, Alarm relay- One for High alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-44
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-150 KG/CM2, Alarm- NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-2a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-45
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- -0.6 to +1.5 KG/CM2, Alarm- Low, Alarm relay- One for Low alarm, Input -4-20ma, Mounting arrangement-2b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-46
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating meter, Range- 0-1500 LPM, Alarm- NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-47
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-28 KG/CM2, Alarm- Low/High, Alarm relay- One for High alarm and One for Low alarm, Input -10-50 mA, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-48
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-150 KG/CM2, Alarm- High, Alarm relay- One for High alarm, Input -4-20ma, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-49
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating Alarm meter, Range- 0-48 LPM, Alarm- Low, Alarm relay- One for Low alarm, Input -4-20ma, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-50
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-120 KG/CM2, Alarm- Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-51
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Differential Pressure Indicating Alarm meter, Range- 0-70 KG/CM, Alarm- Low, Alarm relay- One for Low alarm, Input -4-20 mA (15-pin), Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-52
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-100 KG/CM2, Alarm- High/Low, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-53
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Level Indicating Alarm meter, Range- 0-70 CM, Alarm- Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-54
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Differential Pressure Indicating Alarm meter, Range- 0-1.5 PSIG, Alarm- High/Low, Alarm relay- One for High alarm and One for Low alarm, Input -4-20 mA, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-55
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Differential Temperature Indicating Meter, Range- 0-60Deg.C, Alarm- NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-56
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-7 KG/CM2, Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20ma, Mounting arrangement-2a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-57
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-10 KG/CM2, Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20ma, Mounting arrangement-2a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-58
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Temperature Indicating Alarm meter, Range- 200Deg.C , Alarm- High, Alarm relay- One for High Alarm, Input -4-20ma, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-59
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Temperature Indicating Alarm meter, Range- 0-120Deg.C , Alarm- High, Alarm relay- One for High Alarm, Input -4-20mA, Mounting arrangement-2b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-60
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0 - 0.5 -0- + 0.5 CmWc, Alarm- Low/High, Alarm relay- One for High Alarm and One for Low Alarm, Input -4-20mA, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-61
Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Level Indicating Alarm meter, Range- 1124 - 1172 INCH, Alarm- Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20mA, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-62
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Boiler level Indicating Alarm meter, Range- 0-125 Cm (Linear), Alarm- Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-63
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Steam Flow Indicating Alarm meter, Range- 0-0.75x106 kg/hr(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-64
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Speeder Direction Indicating meter, Range- (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-65
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Boiler pressure Indicating Alarm meter, Range- 0-55 kg/cm(Linear), Alarm- High/Low, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-66
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Cal Spray Flow Indicating meter, Range- 0-3 klpm(Sq Root), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-2b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-67
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod HX Flow Indicating Alarm meter, Range- 0-16 klpm(Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement-2b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-68
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Adj rod cooling Flow Indicating meter, Range- 0-400 lpm(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-69
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2O & HE storage Tk Pr Indicating alarm meter, Range- 0.7-2 kg/cm2 abs(Linear), Alarm- - Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-70
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2O RU Flow Indicating alarm meter, Range- 0-3 klpm(Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-71
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Pump suction Pr Indicating meter, Range- 0.7-2 kg/cm2 abs(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-72
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- GBV position Indicating meter, Range- (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-73
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump Port Weir level Indicating meter, Range- 0-25 Cm(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-74
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump tank pressure Indicating meter, Range- 1-2 kg/cm2 abs(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-75
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump tank level Indicating alarm meter, Range- 0-350 cm(Linear), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-76
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Purification Flow Indicating meter, Range- 0-300 lpm(Sq Root), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-77
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Liquid poison tank Lvl Indicating alarm meter, Range- 0-100 cm(Linear), Alarm- High/Low, Alarm relay- One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-78
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Outlet temp Indicating alarm meter, Range- 0-70 deg C(Linear), Alarm- High, Alarm relay- One for high Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-79
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Intlet temp Indicating alarm meter, Range- 0-70 deg C(Linear), Alarm- High/Low, Alarm relay- - One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-80
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Cal Support Rod Flow Indicating alarm meter, Range- 0-25 Lpm(Sq Root), Alarm-Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-81
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod level Indicating alarm meter, Range- 80-100Percent (Linear), Alarm- High/Low, Alarm relay- One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-82
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump tank sump level Indicating meter, Range- 0-100 Percent (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-83
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-Dump tank exp Joint Indicating alarm meter, Range- 0-1200 Lpm (Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-84
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Int stiff & Dump port Indicating alarm meter, Range- 0-350 Lpm (Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-85
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump Port trans spray Indicating alarm meter, Range- 0-250 Lpm (Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-86
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Stiffener ring Indicating alarm meter, Range- 0-80 Lpm(Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-87
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-He Circulating tank lvl Indicating meter, Range- 0-75 cm (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-88
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Cal Overall level Indicating alarm meter, Range- 0-100 Percent(Linear), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-89
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2O transfer tank Indicating alarm meter, Range- 0-75 cm(Linear), Alarm- High, Alarm relay- One for High Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-90
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Boiler pressure Indicating meter, Range- 0-55 kg/cm2(Linear), Alarm- NA, Alarm relay-NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-91
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-Mod level Indicating meter, Range- 0-100 Percent(Linear), Alarm- NA, Alarm relay-NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-92
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Temp Indicating meter, Range- 0-100 Deg C (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-93
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Liquid poison tank Lvl Indicating alarm meter, Range- 0-100 cm(Linear), Alarm- High/Low, Alarm relay- One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-94
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2o leakage Collection Lvl Indicating alarm meter, Range- 0-75 cm(Linear), Alarm- High, Alarm relay- One for high Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-95
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2O transfer tank Indicating alarm meter, Range- 0-75 cm(Linear), Alarm- High/Low, Alarm relay- One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-96
LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Speeder Direction Indicating meter, Range- (Linear), Alarm- NA, Alarm relay-NA, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent
item-97
Differential Resistance Temperature Transmitter, Make-Elektra Precision .Input- RTD Pt-200,2 wire,X-2.Serial no-16128, Differentila Temperature Transmitter range 0-60 degree centigrade, Output- 04 to 20 mA DC (Two no of output) Zero & span adjustable. Power supply- 118 VAC with connector.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | item-1 | Resistance Temperature Transmitter ( Resistance to Current Converter), Make -Elektra Precision .Input- RTD Pt-200. Temperature range 0-100 degree centigrade, Output- 04 to 20 mA DC (Two no of output) Zero & span adjustable. Power supply- 118 VAC with connector. other detail as Annexure-1.(Bidder should comply one to one in specification as attached) | 25 | number | consignee24.rj | 180 | |
| 2 | item-2 | Spare Elektra ( earlier Lektrolab ) make Resistance Temperature Transmitter. Input RTD Pt.200. Temp Range- 230 - 320 Degree Centigrade. O/P- 04 to 20 mA DC. Single output. Other common details as per attached annexure-1. | 100 | number | consignee24.rj | 180 | |
| 3 | item-3 | Spare Elektra ( earlier Lektrolab ) make Resistance Temperature Transmitter. Input RTD-Pt.200. Temp Range- 0-320 Degree Centigrade. Output- 04 to 20 mA DC with Double isolated outputs. Other common details as per attached annexure-1. | 10 | number | consignee24.rj | 180 | |
| 4 | item-4 | Resistance Temperature Transmitter ( Resistance to Current Converter), Make-Elektra Precision .Input- RTD Pt-100. Temperature range 0-100 degree centigrade, Output- 04 to 20 mA DC (Two no of output) Zero & span adjustable. Power supply- 118 VAC with connector. other detail as Annexure-2.(Bidder should comply one to one in specification as attached) | 20 | number | consignee24.rj | 180 | |
| 5 | item-5 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-Flow indicating alarm meter,Range-0-400 ft/sec,Alarm -High ,Alarm relay-One for High alarm, Input -4-20mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 18 | number | consignee24.rj | 180 | |
| 6 | item-6 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-Temperature indicating alarm meter,Range-0-100 Degree C,Alarm -High ,Alarm relay-One for High alarm, Input -4-20mA,Mounting arrangement-1a,Normal operating 118 V AC , 50 Hz +/-10 Percent | 30 | number | consignee24.rj | 180 | |
| 7 | item-7 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Differential Pressure Indicating Alarm,Range- -15 to +25 gm/cm2,Alarm -High ,Alarm relay-One for High alarm, Input -4-20mA,Mounting arrangement-1a,Normal operating 118 V AC , 50 Hz +/-10 Percent | 15 | number | consignee24.rj | 180 | |
| 8 | item-8 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating Alarm,Range- 0-700 (Squre root scale flow) lpm, Alarm -Low ,Alarm relay-One for Low alarm, Input -10-50mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 9 | item-9 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Temperature Indicating Alarm,Range- 0 to 70 degree C,Alarm -Low/High ,Alarm relay-One for High alarm and One for Low Alarm, Input -4-20mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 10 | number | consignee24.rj | 180 | |
| 10 | item-10 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating meter ,Range- 0-6 (Squre root scale) klpm,Alarm -No Alarm ,Alarm relay-No Alarm, Input -10-50 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 10 | number | consignee24.rj | 180 | |
| 11 | item-11 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Level Indicating meter ,Range- 0-10 Meter ,Alarm -No Alarm ,Alarm relay-No Alarm, Input -4-20 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 12 | item-12 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating meter ,Range- 0-10.7 meter / sec & 0-30 Feet /sec ,Alarm -High ,Alarm relay-One for High alarm, Input -4-20 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 10 | number | consignee24.rj | 180 | |
| 13 | item-13 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating meter ,Range- 0-10.7 meter / sec & 0-30 Feet /sec ,Alarm -High ,Alarm relay-One for High alarm, Input -0-4 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 10 | number | consignee24.rj | 180 | |
| 14 | item-14 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating alarm meter ,Range- 0-0.7 Kg/cm2 ,Alarm -High/Low ,Alarm relay-One for High alarm & One for Low alarm, Input -4-20 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 15 | item-15 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating alarm meter ,Range- 0-1.5 x 106 kg/hr ,Alarm -High ,Alarm relay-One for High alarm , Input -4-20 mA,Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 16 | item-16 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Meter, Range- 0-5 kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20 mA, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 17 | item-17 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Meter, Range- 35-85 Psig, Alarm -NA, Alarm relay- NA, Input -10-50 mA, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 18 | item-18 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Volt Meter Indicating alarm, Range- 0-300 Volt, Alarm- Low, Alarm relay- One for Low alarm, Input -0-300 v dc, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 5 | number | consignee24.rj | 180 | |
| 19 | item-19 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Volt Meter Indicating alarm, Range- 0-75 Volt, Alarm- Low, Alarm relay- One for Low alarm, Input -0-75 v dc, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 5 | number | consignee24.rj | 180 | |
| 20 | item-20 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Volt Meter Indicating alarm, Range- 0-5 mA, Alarm- High, Alarm relay- One for High alarm, Input -0-5 ma, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 5 | number | consignee24.rj | 180 | |
| 21 | item-21 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Volt Meter Indicating alarm, Range- 0-750 mA, Alarm- High, Alarm relay- One for High alarm, Input -0-750 microA, Mounting arrangement-4b,Normal operating 118 V AC, 50 | 5 | number | consignee24.rj | 180 | |
| 22 | item-22 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating alarm meter, Range- 0-100 Psig, Alarm -High, Alarm relay- One for High alarm, Input -10-50 mA, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 23 | item-23 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Light Indicating alarm meter, Range- 160-220 cm, Alarm -Low, Alarm relay- One for Low alarm, Input -10-50 mA, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 24 | item-24 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-4.22 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 25 | item-25 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Indicating Alarm meter, Range- 50-100 Percent, Alarm- Low, Alarm relay- One for Low alarm, Input -0-1 ma, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 26 | item-26 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm Meter, Range- 0-60 Psig, Alarm -Low, Alarm relay- One for Low alarm, Input -4-20 ma, Mounting arrangement-4b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 27 | item-27 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm Meter, Range- 0-70 Kg/cm2, Alarm -Low, Alarm relay- One for Low alarm, Input -4-20 ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 5 | number | consignee24.rj | 180 | |
| 28 | item-28 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm Meter, Range- 0-7 Kg/cm2, Alarm -Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20 ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 5 | number | consignee24.rj | 180 | |
| 29 | item-29 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Light Indicating Meter, Range- 0-60 cm, Alarm -NA, Alarm relay- NA, Input -4-20 ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 5 | number | consignee24.rj | 180 | |
| 30 | item-30 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Light Indicating Meter, Range- 25-82 cm, Alarm -NA, Alarm relay- NA, Input -4-20 ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 31 | item-31 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-15 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 32 | item-32 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Light Indicating Meter, Range- 0-280 cm, Alarm -Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -10-50 mA, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 33 | item-33 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- -2 to +3 Psig, Alarm -High/Low, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 34 | item-34 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-5 Kg/cm2, Alarm -Low, Alarm relay- One for Low Alarm, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 35 | item-35 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-750 Psig, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 36 | item-36 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- -14.05 to +14.05 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 37 | item-37 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-52.7 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 38 | item-38 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-4.22 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 5 | number | consignee24.rj | 180 | |
| 39 | item-39 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-2.1 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-2b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 40 | item-40 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-120 Kg/cm2, Alarm -NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b,Normal operating 118 V AC , 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 41 | item-41 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Temperature Indicating Alarm meter, Range- 0-320Deg.C, Alarm -Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 42 | item-42 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating Alarm meter, Range- 0-2000 LPM, Alarm -Low, Alarm relay- One for Low Alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 5 | number | consignee24.rj | 180 | |
| 43 | item-43 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-14 KG/CM2, Alarm- High, Alarm relay- One for High alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 44 | item-44 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating meter, Range- 0-150 KG/CM2, Alarm- NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-2a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 45 | item-45 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- -0.6 to +1.5 KG/CM2, Alarm- Low, Alarm relay- One for Low alarm, Input -4-20ma, Mounting arrangement-2b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 46 | item-46 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating meter, Range- 0-1500 LPM, Alarm- NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 47 | item-47 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-28 KG/CM2, Alarm- Low/High, Alarm relay- One for High alarm and One for Low alarm, Input -10-50 mA, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 48 | item-48 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-150 KG/CM2, Alarm- High, Alarm relay- One for High alarm, Input -4-20ma, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 49 | item-49 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Flow Indicating Alarm meter, Range- 0-48 LPM, Alarm- Low, Alarm relay- One for Low alarm, Input -4-20ma, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 50 | item-50 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-120 KG/CM2, Alarm- Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 51 | item-51 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Differential Pressure Indicating Alarm meter, Range- 0-70 KG/CM, Alarm- Low, Alarm relay- One for Low alarm, Input -4-20 mA (15-pin), Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 52 | item-52 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-100 KG/CM2, Alarm- High/Low, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 53 | item-53 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Level Indicating Alarm meter, Range- 0-70 CM, Alarm- Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20ma, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 54 | item-54 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Differential Pressure Indicating Alarm meter, Range- 0-1.5 PSIG, Alarm- High/Low, Alarm relay- One for High alarm and One for Low alarm, Input -4-20 mA, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 55 | item-55 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Differential Temperature Indicating Meter, Range- 0-60Deg.C, Alarm- NA, Alarm relay- NA, Input -4-20ma, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 56 | item-56 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-7 KG/CM2, Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20ma, Mounting arrangement-2a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 57 | item-57 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0-10 KG/CM2, Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20ma, Mounting arrangement-2a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 58 | item-58 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Temperature Indicating Alarm meter, Range- 200Deg.C , Alarm- High, Alarm relay- One for High Alarm, Input -4-20ma, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 59 | item-59 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Temperature Indicating Alarm meter, Range- 0-120Deg.C , Alarm- High, Alarm relay- One for High Alarm, Input -4-20mA, Mounting arrangement-2b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 60 | item-60 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Pressure Indicating Alarm meter, Range- 0 - 0.5 -0- + 0.5 CmWc, Alarm- Low/High, Alarm relay- One for High Alarm and One for Low Alarm, Input -4-20mA, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 61 | item-61 | Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Level Indicating Alarm meter, Range- 1124 - 1172 INCH, Alarm- Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20mA, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 62 | item-62 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Boiler level Indicating Alarm meter, Range- 0-125 Cm (Linear), Alarm- Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 24 | number | consignee24.rj | 180 | |
| 63 | item-63 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Steam Flow Indicating Alarm meter, Range- 0-0.75x106 kg/hr(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 64 | item-64 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Speeder Direction Indicating meter, Range- (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 65 | item-65 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Boiler pressure Indicating Alarm meter, Range- 0-55 kg/cm(Linear), Alarm- High/Low, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 66 | item-66 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Cal Spray Flow Indicating meter, Range- 0-3 klpm(Sq Root), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-2b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 4 | number | consignee24.rj | 180 | |
| 67 | item-67 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod HX Flow Indicating Alarm meter, Range- 0-16 klpm(Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement-2b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 4 | number | consignee24.rj | 180 | |
| 68 | item-68 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Adj rod cooling Flow Indicating meter, Range- 0-400 lpm(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 36 | number | consignee24.rj | 180 | |
| 69 | item-69 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2O & HE storage Tk Pr Indicating alarm meter, Range- 0.7-2 kg/cm2 abs(Linear), Alarm- - Low/High, Alarm relay- One for High alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 70 | item-70 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2O RU Flow Indicating alarm meter, Range- 0-3 klpm(Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement-4b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 71 | item-71 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Pump suction Pr Indicating meter, Range- 0.7-2 kg/cm2 abs(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 72 | item-72 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- GBV position Indicating meter, Range- (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement-1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 73 | item-73 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump Port Weir level Indicating meter, Range- 0-25 Cm(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 74 | item-74 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump tank pressure Indicating meter, Range- 1-2 kg/cm2 abs(Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 75 | item-75 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump tank level Indicating alarm meter, Range- 0-350 cm(Linear), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 4 | number | consignee24.rj | 180 | |
| 76 | item-76 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Purification Flow Indicating meter, Range- 0-300 lpm(Sq Root), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 4 | number | consignee24.rj | 180 | |
| 77 | item-77 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Liquid poison tank Lvl Indicating alarm meter, Range- 0-100 cm(Linear), Alarm- High/Low, Alarm relay- One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 78 | item-78 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Outlet temp Indicating alarm meter, Range- 0-70 deg C(Linear), Alarm- High, Alarm relay- One for high Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 79 | item-79 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Intlet temp Indicating alarm meter, Range- 0-70 deg C(Linear), Alarm- High/Low, Alarm relay- - One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 80 | item-80 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Cal Support Rod Flow Indicating alarm meter, Range- 0-25 Lpm(Sq Root), Alarm-Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 81 | item-81 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod level Indicating alarm meter, Range- 80-100Percent (Linear), Alarm- High/Low, Alarm relay- One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 82 | item-82 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump tank sump level Indicating meter, Range- 0-100 Percent (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 83 | item-83 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-Dump tank exp Joint Indicating alarm meter, Range- 0-1200 Lpm (Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 84 | item-84 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Int stiff & Dump port Indicating alarm meter, Range- 0-350 Lpm (Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 85 | item-85 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Dump Port trans spray Indicating alarm meter, Range- 0-250 Lpm (Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 86 | item-86 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Stiffener ring Indicating alarm meter, Range- 0-80 Lpm(Sq Root), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 87 | item-87 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-He Circulating tank lvl Indicating meter, Range- 0-75 cm (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 88 | item-88 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Cal Overall level Indicating alarm meter, Range- 0-100 Percent(Linear), Alarm- Low, Alarm relay- One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 3 | number | consignee24.rj | 180 | |
| 89 | item-89 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2O transfer tank Indicating alarm meter, Range- 0-75 cm(Linear), Alarm- High, Alarm relay- One for High Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 90 | item-90 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Boiler pressure Indicating meter, Range- 0-55 kg/cm2(Linear), Alarm- NA, Alarm relay-NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 91 | item-91 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag-Mod level Indicating meter, Range- 0-100 Percent(Linear), Alarm- NA, Alarm relay-NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 92 | item-92 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Mod Temp Indicating meter, Range- 0-100 Deg C (Linear), Alarm- NA, Alarm relay- NA, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 1 | number | consignee24.rj | 180 | |
| 93 | item-93 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Liquid poison tank Lvl Indicating alarm meter, Range- 0-100 cm(Linear), Alarm- High/Low, Alarm relay- One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 94 | item-94 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2o leakage Collection Lvl Indicating alarm meter, Range- 0-75 cm(Linear), Alarm- High, Alarm relay- One for high Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 95 | item-95 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- D2O transfer tank Indicating alarm meter, Range- 0-75 cm(Linear), Alarm- High/Low, Alarm relay- One for high Alarm and One for Low Alarm, Input -4-20madc, Mounting arrangement- 1b, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 96 | item-96 | LEKTROLAB Indicating Alarm Meter, make - M/S ELEKTRA PRECISION SYSTEMS, Tag- Speeder Direction Indicating meter, Range- (Linear), Alarm- NA, Alarm relay-NA, Input -4-20madc, Mounting arrangement- 1a, Normal operating 118 V AC, 50 Hz +/-10 Percent | 2 | number | consignee24.rj | 180 | |
| 97 | item-97 | Differential Resistance Temperature Transmitter, Make-Elektra Precision .Input- RTD Pt-200,2 wire,X-2.Serial no-16128, Differentila Temperature Transmitter range 0-60 degree centigrade, Output- 04 to 20 mA DC (Two no of output) Zero & span adjustable. Power supply- 118 VAC with connector. | 20 | number | consignee24.rj | 180 |
Discover companies most likely to bid on this tender
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
16-Oct-2025, 10:00 am
Opening Date
16-Oct-2025, 10:30 am
Extended Deadline
13-May-2025, 9:00 am
Opening Date
13-May-2025, 9:30 am
Extended Deadline
22-Apr-2025, 10:00 am
Opening Date
22-Apr-2025, 10:30 am
Extended Deadline
21-Mar-2025, 9:00 am
Opening Date
21-Mar-2025, 9:30 am
Extended Deadline
11-Mar-2025, 9:00 am
Opening Date
11-Mar-2025, 9:30 am
Key insights about RAJASTHAN tender market
The eligibility requirements include being a registered entity with valid business licenses. Vendors must comply with all technical and financial prerequisites stated in the tender documentation. Additionally, firms seeking exemptions from experience or turnover criteria must provide suitable supporting documents for verification.
Bid submissions must include OEM Authorization Certificates and any additional supporting documents requested in the ATC (Additional Technical Criteria). Compliance with the BoQ specifications is necessary, confirming adherence to all technical standards outlined in the tender.
Documents must be submitted electronically through the GEM platform. It is critical to ensure the submission adheres to accepted formats, preferably in PDF, and includes all required certificates and compliance documentation as specified in the tender guidelines.
The Earnest Money Deposit (EMD) for this tender is set at ₹18,644. Specific performance security requirements will be outlined in the tender documentation. Bidders need to maintain compliance with security and payment terms throughout the contract.
Yes, there are special provisions for Micro, Small, and Medium Enterprises (MSEs) and startups in alignment with government initiatives. These groups are given preferential treatment in the evaluation process, promoting inclusiveness in government procurement practices. Compliance with Make in India policies is also encouraged, and adherence to local content laws may be considered favorably.
National Test House
📍 CHENNAI, TAMIL NADU
Nuclear Power Corporation Of India Limited
📍 CHITTORGARH, RAJASTHAN
Nuclear Power Corporation Of India Limited
📍 CHITTORGARH, RAJASTHAN
Jammu And Kashmir Police
📍 SRINAGAR, JAMMU & KASHMIR
Nuclear Power Corporation Of India Limited
📍 CHITTORGARH, RAJASTHAN
Sign up now to access all documents
Main Document
BOQ
BOQ
OTHER
OTHER
ATC